ML18153A886

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-280/94-02 & 50-281/94-02 on on 940102-0205.Violation Noted.Nrc Concerned About Reliability of Reactor Vessel Standpipe Level Indication
ML18153A886
Person / Time
Site: Surry  
Issue date: 03/07/1994
From: Merschoff E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
Shared Package
ML18153A887 List:
References
NUDOCS 9403150277
Download: ML18153A886 (3)


See also: IR 05000280/1994002

Text

' ,

MAR - 7 1994

Docket Nos. 50~280, 50-281

License Nos. DPR-32, DPR-37

Virginia Electric and Power Company

ATTN: Mr. W. L. Stewart

Senior Vice President - Nuclear

5000 Dominion Boulevard

Glen Allen, .VA

23060

. Gentlemen:

SUBJECT:

NRC INSPECTION REPORT NOS. 50-280/94-02 AND 50-281/94-02

4

. This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by

. Mr. M. Branch of this office on January 2 through February 5, 1994.

The

inspection included a review of activities authorized for your Surry facility.

At the conclusion of the inspection, the findin~s.were discussed with those

members of your staff identified in the enclosed report.

Areas examined during the inspectiqn are identified in the report. Within

. these areas, the inspection consisted ~f selective examinations of procedures

and representative records, inter~iews with personnel, and observation of

activities in progress.

The enclosed inspection report identifies activities that violated NRC

requirements that will not be subject to enforcement action because the

licensee's efforts in correcting the violation meet the criteria specified in

Section VII.B of the Enforcement Policy.

During the inspection period, two Unresolved Items were identified.

One

  • involved an unexpected de~rease in the Unit I.reactor vessel indicated water

level while the unit was shutdown and depressurized, paragraph 3.i. A similar

ev~nt ~lso occurred during the previous Unit 1 refueling outage.

We

  • understand that your evaluation concluded the most probable cause of the

events to be restrictions in the reactor head vent piping; however, testing

  • performed to date has been unable to verify this conclusion.

We are concerned

about the reliability of the reactor vessel standpipe level indication because

this instrumentation would be relied upon during mid~loop operations to

prevent a loss of shutdown cooling.

The second Unresolved Item involved a hydrogen gas burn inside the pressurizer

on February 3, 1994, for which the root cause evaluation has *not been

complet~d, paragraph 3.j.

We are concerned about this event because of the

potential damage to safety-related equipment.

In order to resolve these two issues, please forward to this offi~e, within 30

davs of the receipt of this letter; what additional actions ybu plan to take

9403150277 940307

DR

ADOCK 05000280

PDR

. .! 4 Q 1. 0 1:i

I I

IE-01

. **

' .

Virginia Electric & Power Company

2

~. ' " .

to preverit future reactor vessel water level indication probl~ms and the

results and any corrective actions you plan to take as a result of your

hydrogen burn root cause evaluation.

In accordance with 10 CFR 2.790 of the NRC's "Rules bf Practice", a copy of

  • this letter and its enclosure will be placed.in the NRC Public Document Room.

The response directed by this letter is not subject to the clearance

procedures of the Office of Management and Budget as required by the Paperwork

Reduction Act of 1980, Pub. L. No.96-511.

Should you have any q~estions concerning this letter, please cont~ct us .

Enclosure:

NRC Inspection Report

cc w/encl:

M~ L. Bowling, Jr., Manager

Nuclear Licensing

  • Virginia Electric & Power Company

5000 Dominion Boulevard

Glen Allen, VA

23060

M. R. Kansler.

Station Manager

Surry Power Station

P. 0. Box 315

Surry, VA

23883

Ray D. Peace; Chairman

Surry County Board of Supervisors

P.O. Box 130

Dendron, VA

23839

Dr. W. T. Lough

. Sincerely,

Original Signed by

Jon R. Johnson (for)

Ellis W. Merschriff, Director

.Di~ision of Reactor Projects

Virginia State Corporation Commissiori

Division of Energy Regulation

P. 0. Box 1197

Richmond, .VA

23209

cc w/encl cont'd:

(See page 3)

Virginia Electric & Power Company

cc w/encl cont'd:

Michael W. Maupin

Hunton and Williams

Riv~rfront Plaza, East Tower

951 E. Byrd Street

Richmond, VA

23219

Robert B. Strobe, M.D., M.P.H. *

State Health Commissioner

Office of the Commissioner

Virginia Department of Health

P. 0. Box 2448

Richmorid, VA* 23218

. Attorney General

Supreme Court Building

101 North 8th Street

Richmond, VA

23219

bee w/encl:

G. Belisle, RII

L. Garner, RI I .

B-. -Bue kl ey, NRR

Document Control Desk

U.S. Nuclear Regulatory Commission

Resident Inspector Office

Surry Nuclear Powe~ Station

5850 Hog Island Road

Surry, VA

23883,

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

R6~te 2, Box 78-A

Mineral, VA

23117

DRP: RII

1-vVrr-

LGarner

03/Cl7 /94

DRµr

GBlffi sl e

03fb *i/94

I

DRP:R!:I

JJU'J

MSinkule

03/01 /94

3

MAR - 7 1994