r' Mr. 'J.P. O'Hanlon Senior Vice President - Nu ar

.)

April 20, 1998 e Virginia Electric and Power Company 5000 Dominion Blvd.

Glen Allen, Virginia 23060

SUBJECT:

SURRY NUCLEAR POWER STATION UNITS 1 AND 2, REQUEST FOR ADDITIONAL INFORMATION RELATED TO REACTOR VESSEL STRUCTURAL INTEGRITY (GENERIC LETTER 92-01, REVISION 1, SUPPLEMENT 1) (TAC NOS. MA0576 AND MA0577)

Dear Mr. O'Hanlon:

In your letter dated September 25, 1997, you responded to a May 22, 1997, NRC request for additional information (RAI). The RAI requested an assessment of the application of the ratio procedure, as described in Position 2.1 of Regulatory Guide 1.99, Revision 2, to the pressure/temperature (PT) limits curves and the low temperature overpressure (L TOP) limits for Surry 1 and 2.

The NRC staff has reviewed your response to the RAI and determined that the assessment of reactor pressure vessel integrity did not properly account for chemical composition and irradiation environment differences. Our evaluation is enclosed. As a result, we request you resubmit your evaluation to account for irradiation environment and chemical composition differences. Your response is requested within 90 days of receipt of this letter.

  • Docket Nos. 50-280 and 50-281

Enclosure:

As stated cc w/enclosure: See next page Distribution

, :.s:Dockef"F°il~

PUBLIC PDll-1 RF J. Zwolinski T. Harris (e-mail _only SE, TLH3)

OGC ACRS L. Plisco, RII

,***1v

,:.. '" \\...,,_,,.j "

FILENAME - G:\\SUR OFFICE PM:PDll-1 NAME DATE COPY 9804230071 980420 PDR ADOCK 05000280 P

?DR LA:PDll-1 Dunninft~

t/-Jlt /98 Sincerely, (81iMi~H~. ~~fs1ben~ s3Jriior Project Manager Project Directorate 11-1 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation AD:PDll-1 P.T. Kuo Yes/No

e Mr. J. P. O'Hanlon Virginia Electric and Power Company cc:

Mr. Michael W. Maupin, Esq.

Hunton and Williams Riverfront Plaza, East Tower 951 E. Byrd Street Richmond, Virginia 23219 Mr. David Christian, Manager Surry Power Station Virginia Electric and Power Company 5570 Hog Island Road Surry, Virginia 23883 Senior Resident Inspector Surry Power Station U. S. Nuclear Regulatory Commission 5850 Hog Island Road Surry, Virginia 23883 Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 Dr. W. T. Lough Virginia State Corporation Commission Division of Energy Regulation P. 0. Box 1197 Richmond, Virginia 23209 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, Georgia 30303 Robert B. Strobe, M.D., M.P.H.

State Health Commissioner Office of the Commissioner Virginia Department of Health P.O. Box 2448 Richmond, Virginia 23218 Surry Power Station Office of the Attorney General Commonwealth of Virginia 900 East Main Street Richmond, Virginia 23219 Mr. J. H. McCarthy, Manager Nuclear Licensing & Operations

- - Support

  • Innsbrook Technical Center Virginia Electric and Power Company 5000 Dominion Blvd.

Glen Allen, Virginia 23060 Mr. R. C. Haag U.S. Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303 Mr. W. R. Matthews, Manager North Anna Power Station P. 0. Box 402 Mineral, Virginia 23117