September 24, 1999 -
Mr. J. P. O'Hanlon Senior Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060
SUBJECT:
SURRY POWER STATION, UNIT 2 RE: INSERVICE INSPECTION RELIEF REQUEST NO. SR-026 {TAC NO. MA4967)
Dear Mr. O'Hanlon:
The purpose of this letter is to grant the relief you requested for Surry Power Station, Unit 2, in relief request SR-026 related to your inservice inspection (ISi) programs.
In a letter dated February 16, 1999, you requested relief from certain inspection requirements related to your ISi program. Our evaluation and conclusions are contained in Enclosures 1 and 2. The Code requirements for the weld configurations addressed in Relief Request SR-026 are impractical because the weld configurations prevent full examination coverage. Without relief, design modifications would be necessary, which would cause a considerable burden.
The subject relief request is granted, pursuant to 1 O CFR Part 50.55a(g)(6)(i), as the Code requirements are impractical, and your proposed alternatives provide reasonable assurance of operational readiness for the affected systems.
The staff has completed its evaluation of this matter; therefore, we are closing TAC No. MA4967.
Docket No. 50-281
Enclosures:
- 1. Safety Evaluation
- 2. Technical Letter Report cc w/encls: See next page Distribution:
- ~~.Docket File_:.
E. Dunnington PUBLIC G. Edison (2)
PDll-1 R/F R. Scholl (e-mail SE)
J. Zwolinski/S.Black OGC H. Berkow GHill (4)
DOCUMENT NAME: G:\\PDll-1\\SURRY\\MA4967.WPD Sincerely, ORIGINAL SIGNED BY:
Richard L. Emch, Jr., Chief, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation To receive a copy of this document, indicate in the box C=Copy w/o attachment/enclosure E=Co y witlil a:~achment/enclosure N = No 00 OFFICE PDll-1/PM 990927009~--.990924 - ----- --- -~Ql:~~A~L RECORD tOPY PDR ADOCK 05000281 i
~
p PDR
~~---
r e
e UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555--0001 September 24, 1999
SUBJECT:
SURRY POWER STATION, UNIT 2 RE: INSERVICE INSPECTION RELIEF REQUEST NO. SR-026 (TAC NO. MA4967)
Dear Mr. O'Hanlon:
The purpose of this letter is to grant the relief you requested for Surry Power Station, Unit 2, in relief request SR-026 related to your inservice inspection (ISi) programs.
In a letter dated February 16, 1999, you requested relief from certain inspection requirements related to your ISi program.
- Our evaluation and conclusions are contained in Enclosures 1 and 2. The Code requirements for the weld configuration addressed in Relief Request SR-026 are impractical because the weld configurations prevent full examination coverage, and without relief design modifications would be necessary, which would cause a considerable burden. The subject relief request is granted, pursuant to 1 O CFR Part 50.55a(g)(6)(i), as the Code requirements are impractical, and your proposed alternatives provide reasonable assurance of operational readiness for the affected systems.
The staff has completed its evaluation of this matter; therefore, we are closing TAC No. MA4967.
Docket No. 50-281
Enclosures:
- 1. Safety Evaluation
- 2. Technical Letter Report cc w/encls: See next page Sincerely, Richard L. Emch, Jr., Chief, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation
I W
I
-v.
e Virginia Electric and Power Company cc:
Mr. Donald P. Irwin, Esq.
Hunton and Williams Riverfront Plaza, East Tower 951 E. Byrd Street Richmond, Virginia 23219 Mr. E. S. Grecheck Site Vice President Surry Power Station Virginia Electric and Power Company 5570 Hog Island Road Surry, Virginia 23883 Senior Resident Inspector Surry Power Station U. S. Nuclear Regulatory Commission 5850 Hog Island Road Surry, Virginia 23883 Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 Dr. W. T. Lough Virginia State Corporation Commission Division of Energy Regulation P. 0. Box 1197 Richmond, Virginia 23209 Robert B. Strobe, M.D., M.P.H.