REVISION 25 1/96 SPS UFSAR VIRGINIA ELECTRIC AND POWER COMPANY OPERATIONAL QUALITY ASSURANCE PROGRAM TOPICAL REPORT 9601260065 960117 PDR ADOCK 05000280 K

PDR _

,~

VEP-1-SA (UPDATED)

Amendment Five June, 1986 (Updated 1/96) 1 *.

REVISION 25 1/96 SPS UFSAR TABLE OF CONTENTS Section No.

Title Page Table of Contents 17.2-i List of Figures 17-2-iii

  • List of Tables 17.2-iii List of Amendments 17.2-iv Abstract 17.2-v 17.2 Quality Assurance During the Operations Phase 17.2-1
  • 17.2.0 General 17.2-1

,, 1 Topical Report 17.2-1

.2 Quality Assurance Standards and Guides 17.2-1 17.2.1 Organization 17.2-3 17.2.1.1 General Description 17.2-3

.2 Nuclear Management 17.2-4

.3 Organization 17.2-11 17.2.2 Quality Assurance Program 17.2-12 17.2.2.1 General Description 17.2-12

.2 Quality Assurance Program 17.2-13

.3 Identification of Structures, Systems, and Components 17.2-14

.4 Periodic Review of the Operational Quality Assurance 17.2-14 Program

.5 Qualification of Nuclear Oversight Personnel 17.2-14

.6 Qualification of Other Support Personnel 17.2-15

.7 Certification of Quality Assurance Department 17.2-15 Personnel

.8 Certification of Other Support Personnel 17.2-15 17.2-i June, 1986

REVISION 25 Section No.

17.2.3 17.2.4 17.2.5 17.2.6 17.2.7 17.2.8 17.2.9 17.2.10 17.2.11 17.2.12 17.2.13 17.2.14 17.2.15 17.2.16

.1

.2 17.2.17 17.2.18 1/96 SPS UFSAR Title Design Control Procurement Document Control Instructions, Procedures, and Drawings Document Control Control of Purchased Material, Equipment, and Services Identification and Control of Material~, Parts, and Components Control of Special Process Inspection Test Control Control of Measuring and Test Equipment Handling, Storage, and Shipping Inspection, Test, and Operating Status Nonconforming Materials, Parts, and Components Corrective Action Authority to Stop Work Imposition of "Stop Work" Quality Assurance Records Audits 17.2-ii June, 1986 Page 17.2-16 17.2-18 17.2-19 17.2-20 17.2-21 17.2-23 17.2-24 17.2-25 17.2-27 17.2-28 I.

17.2-29 I

17.2-30 17.2-31 17.2-33 17.2-34 17.2-34 17.2-36 17.2-37

REVISION 25 1/96 SPS UFSAR Figure No.

17.2.1-1 17.2.1-2 Table No.

17.2.0 17.2.1 LIST OF FIGURES (APPENDIX A)

Title Nuclear Organization Nuclear Station Organization LIST OF TABLES (APPENDIX 8)

Conformance of the Company's Operational Quality Assurance Program to NRC Regulatory Guides and ANSI Standards Relationship of the Company's Operational Quality Assurance Program to Appendix B, 10 CFR 50 17.2-iii June, 1986 Page 17.2-40 17.2-41 Page.*

17.2-42 17.2-92 I

REVISION 25 1/96 Amendment No.

Original One Two Three Four Four (Updated)

Five Five (Updated)

Five (Updated)

Five (Updated)

Five (Updated)

Five (Updated)

Five (Updated)

Five (Updated)

I SPS UFSAR LIST OF AMENDMENTS 17.2-iv June, 1986 Amendment Date 07-01-75 12-30-75 09-27-76 03-01-77 10-01-82 08-30-85 06-30-86 03-23-87 06-21-88, 06-21-89 06-21-90 05-28-91 06/16/92 02-28-94

REVISION 25 1 /96 SPS UFSAR ABSTRACT This topical report describes Virginia Electric and Power Company's, hereafter referred to as the Company, quality assurance program for the operational phase of its nuclear power stations. The report is organized as, distributed, and used for Chapter 17, part 2 - Quality Assurance (Operations) - of the Company's Updated Final Safety Analysis Reports. The Company quality assurance program conforms to applicable regulatory requirements such as 10 CFR 50, Appendix B and to approved industry standards endorsed therein as clarified within this. topical report. Included is a point-by-point comparison of the program with the 18 criteria of 10 CFR 50, Appendix B.

This topical report is intended to be a comprehensive up-to-date description of the Company's Operational Quality Assurance Program for nuclear power generating stations.

The Operational Quality Assurance Program is defined as those managerial and administrative policies and controls used to assure the safe and reliable operation of the nuclear facilities. These include all those planned and systematic actions necessary to provide adequate confidence to management and regulatory agencies

  • that structures, systems, and components will perform satisfactorily in service. The Operational Quality Assurance Program.* encompasses policies, directives, instructions, training, and procedures which ensure compliance with reguations, Codes, standards, licenses, and other Company commitments. As such, this topical report, in conjunction with the applicable operating license, provides the foundation for operating the nuclear facilities in a manner which ensures the safety of the public, employees, and plant equipment. The policies are further defined through the Nuclear Operating Department Standards (NODS), the applicable Safety Analysis Report (SAR), Nuclear Design Control Manual (NDCM), and each facility's emergency plan, physical security plan, radiological protection plan, and fire protection plan.

Administrative and implementing procedures govern the various aspects of day-to-day operation of the nuclear facilities.

The Company's Operational Quality Assurance Program Topical Report is referred to by several generic titles both within this document and within other administrative controls for each nuclear facility. These include Chapter 17.2 of the UFSAR. the [Company's] quality assurance program, the Operational Quality Assurance Program (upper and lower cased letters), the QA Topical Report, VEP 1-5A, Quality Assurance Program - Operational Phase, etc. These are used interchangeably to refer to this document which represents Management's philosophy and methodologies for complying with the 18 criteria of 10 CFR 50, Appendix B.

17.2-v June, 1986

)

REVISION 25 1/96 SPS UFSAR 17.2 17.2.0 QUALITY ASSURANCE DURING THE OPERATIONS PHASE General It is the policy of the Company to establish and maintain a formal quality assurance program for the operational phase of nuclear power generating statiqns.

This program is described by written policies, standards, and procedures.

The application of this program accomplishes two important objectives: (1) to provide orderly, uniform administrative and managerial procedures to assure safe., reliable,

  • .. and economic operation of nuclear power stations and (2) to assure compliance with regulations promulgated by the U;S. Nuclear Regulatory Commission.

17.2.0.1 Topical Report This topical report is written in the format of a Safety Analysis Report {SAR)

Chapter 17, part 2, "Quality Assurance During the Operations Phase", in accordance with the NRC's "Standard Format and Content of Safety Analysis Reports for Nuclear Power Plants" (Nov. 1975) and subsequent NRC guidelines. The quality assµrance program described herein is applicable to all Company nuclear power stations as referenced by Chapter 17 of the stations' UFSARs.

Subsequent changes to the Company's Operational Quality Assurance Program will be incorporated as applicable in this topical report. The topical report is intended to be a comprehensive description of the Company's Operational Quality Assurance Program for nuclear power stations.

. 17.2.0.2 Quality Assurance Standards and Guides The Company Operational Quality Assurance Program conforms to Appendix B

  • of 1 O CFR 50 as amended and complies with the regulatory positions of the Reg'iilatory Guides indicated in table 17.2.0, as modified or clarified in that table.

17.2-1 June, 1986

REVISION 25 1/96 SPS UFSAR TABLE 17.2.0 Conformance of the Company's Operational Quality Assurance Program To NRG Regulatory Guides and ANSI Standards The ANSI standards, and other documents (i.e., other standards, codes, regulations, or appendices) that are required to be included as a part of this quality assurance program are either identified in Table 17.2.0 or they are described her~in.

Although this table includes references to ANSI Standards and Regulatory Guides that are required to be a part of this quality assurance program, the table is not intended to be a complete list of all NRG Regulatory Guides (etc.) to which the Company is committed. The specific applicability or acceptability of these listed standards, codes, regulations, or appendices is either covered in this* program or such documents are not considered as quality assurance program requirements; although they may be used as guidance. When sections of ANSI Standards and other documents are referenced within this program, it is understood that the Company will comply with the referenced sections as clarified in Table 17.2.0.

GENERIC-STATEMENTS WITH REGARDS TO TABLE 17.2.0 AND THE OPERATIONAL QUALITY ASSURANCE PROGRAM For operations phase maintenance and modification activities which are comparable in nature and extent to similar activities conducted during the construction phase, the Company shall control these activities under this Operational Quality Assurance Program: Designated modifications may be controlled under a contractor's

. Quality Assurance Program which has been.. approved by the Company's Quality Assurance Program.

When this Operational Quality Assurance Program or an approved contractor's Quality Assurance Program is used, the Company shall comply with the Regulatory Position established in the guides listed herein in that quality

  • assurance programmatic/administrative requirements included therein (subject to the clarification in this table) shall apply to these maintenance and modification activities even though such *requirements may not have been in effect originally. Maintenance or modifications which may affect the function of safety-related structures, systems, or components shall be performed in a manner at least equivalent to that specified in original design bases and requirements, materials specifications, and inspection requirements. A suitable level of confidence in structures, systems, or components on which maintenance or modifications have been performed shall be attained by appropriate inspection and performance testing.

Definitions in the referenced standards in this table which are not included in ANSI N45.2.10 will be used as clarified in the Company's commitment to Regulatory Guide 1.74.

17.2-2 June, 1986

,*r*~..

REVISION 25 1/96 SPS UFSAR 17.2.1 ORGANIZATION 17.2.1.1 General Description A.

Nuclear Organization Nuclear is divided into four distinct groups; Nuclear Operations, Nuclear Engineering and Services, Nuclear Security and Administrative Services, and Nuclear Oversight.

Nuclear Operations, Nuclear Engineering and Services, and Nuclear Security and Administrative Services are responsible for licensing, operation, and support of the nuclear power stations. Nuclear Oversight has the responsibility to assure compliance with the. Operational Quality Assurance Program.

8.

Nuclear Operations Nuclear Operations is a line organization responsible for operation and maintenance of the Surry and North Anna Nuclear Power Stations. This organization is comprised of various departments, including Operations,

.Maintenance, Outage & Planning, Nuclear Licensing and Operations

  • 'Sup-port, Station Nuclear Safety, Station Emergency Planning, Station Licensing, Station Procedures, Radiological Protection, Chemistry, Safety

& Loss Prevention, Station Records Management, and Nuclear Site Services (maintenance support, modifications, and plant improvement projects).

C.

Nuclear Engineering and Services D.

Nuclear Engineering and Services is responsible for support of the nuclear organization through providing engineering services, financial and business services, personnel training, and emergency planning. The engineering departments are the design authorities for the Nuclear Organization and provide design and operational engineering support to then uclear stations., The Financial and Business Services Department provides s1.ipport through procurement, materials management, document control, and records management activities.

The Nuclear Training Department develops and administers training to Nuclear Operations, Nuclear Engineering and Services, Nuclear Security and Administrative Services, and Nuclear Oversight personnel. Nuclear Emergency Planning schedules and coordinates emergency training exercises with federal, state, and local agencies and works with internal groups to ensure that emergency plans meet regulatory requirements and commitments.

Nuclear Security and Administrative Services The Nuclear Security and Administrative Services Group is responsible for support functions associated with Nuclear.Plant Security, Personnel Administration, Fitness For Duty, and Nuclear Projects.

17.2-3

REVISION 25 1/96 SPS UFSAR E.

Nuclear Oversight Nuclear Oversight is responsible for independently planning and performing activities to

  • verify the development and effective implementation of nuclear management's quality assurance programs for engineering, procurement, construction, modification, maintenance, and operation activities associated with the Nuclear Stations.

17.2.1.2 Nuclear Management A.

Senior Vice President - Nuclear The Senior Vice President - Nuclear has corporate responsibility for and directs the planning and development of the Nuclear Organization staff, organization resources, and nuclear power generation.

1. Management Safety Review Committee (MSRC)

  • The-*)\\IISRC is the body which performs the offsite safety review function. It reports to the Senior Vice President - Nuclear and provides an independent review in the areas of station operations, maintenance, reactivity management, engineering, chemistry & radiochemistry, radiological safety, quality assurance practices, and emergency preparedness. The Technical Specifications of each station further

,.,, define the function, composition, alternates, consultants, meeting

,frequency, quorum, reviews, audits, authority and records of this committee.

One of the functions of the MSRC is to oversee the Safety Evaluation Program to ensure that it is effective in identifying unreviewed safety questions. The MSRC accomplishes this function by reviewing a sample of_ ~pproved safety evaluations* to ensure that unreviewed safety

  • . questions are being properly identified and by conducting periodic assessments of the Safety Evaluation Program.

The review of a sample of safety evaluations uses a graded and safety significant approach to select safety evaluations for review. All safety evaluations are screened upon receipt, and the following criteria are used to select a sample for MSRC review:

Safety evaluations for certain types of activities will receive a 100% review by the MSRC. These include, for example, safety

. evaluations for Technical Specification changes, justifications for continued operation and special tests.

All safety evaluations for changes that have a high potential for impacting nuclear safety or regulatory requirements will be reviewed by the MSRC.

17.2-4

REVISION 25 1/96 SPS UFSAR B.

. J}::.

A representative sample of safety evaluations will be reviewed from the remaining safety evaluations prepared. These safety evaluations will be selected to ensure a representative sample of safety evaluations of each type of activity has been reviewed in an amount consistent with program objectives. Provisions are also in place to adjust the sample sizes of the safety evaluations based on MSRC and assessment findings.

2. Nuclear Oversight Board (NOB)

The NOB functions to provide independent review and oversight of nuclear activitie$ at the senior management level and in an advisory

. capacity to the Senior Vice President - Nuclear. The NOB reviews nuclear management practices, policy issues, regulatory and performance trends and organizational factors relating to nuclear activities, and provides program oversight through management reports, document reviews, group discussions, and individual experience. Membership consists of senior nuclear utility executives and other members appointed on the basis of industry knowledge and/or expertise.

Vice President-Nuclear Operations The Vice President - Nuclear Operations is the Corporate individual responsible to the Senior Vice President - Nuclear for the operation of the nuclear power stations. He has overall responsibility for implementing the quality assurance program for the operational phase of the nuclear power stations.

1. Station Manager
  • Responsible to the Vice President - Nuclear Operations for the* overall safe and efficient operation of the station, and for the implementation of quality assurance requirements in the areas specified by the operational quality assurance program. The Station Manager has supervisory control over all Virginia Electric and Power Company personnel within the station organization and administrative control over all other Company and non-Company individuals within the nuclear site's boundary.

The Station Manager is the local representative of Company management and is empowered to implement all Company policy with regard to operations of the facility, support of Company public relations policy, and employee relations

. policies. The Station Manager is also responsible for coordinating station functions with offsite (Company and non-Company) agencies and services.

In the absence of the Station Manager, these duties will be assumed by the Assistant Station Manager (Operations & Maintenance) unless otherwise designated in writing.

17.2-5

  • 1,

-_,'1 I

REVISION 25 1/96 SPS UFSAR a.* station Nuclear Safety and Operating Committee Serves in an advisory capacity to the Station Manager.

The technical specifications of each station define the responsibilities of this committee.

The Station Nuclear Safety and Operating Committee is separate from operational quality assurance activities in that its authority and responsibilities are not established by the Operational Quality Assurance Program. However, since the prime responsibility of this committee is to provide a continuing review* of the operational and safety aspects of the station, it does perform a quality assurance function.

b. Assistant Station Manager (Operations and Maintenance)

Responsible to the Station Manager for directing and coordinating all aspects of day-to-day station operations and maintenance. The Assistant Station Manager Operations and Maintenance (O&M) is the Vice Chairman of the Station Nuclear Safety and Operating

.. Committee (SNSOC) and is responsible for planning and coordination of unit outages.

In the absence of the Assistant Station Manager (O&M), the Station Manager assumes the duties of the Assistant Station Manager (O&M). In the absence of both the Station Manager and the Assistant Station Manager (O&M),

these duties will be assumed by the Superintendent - Operations unless otherwise designated in writing.

b.1 Superintendent-Operations The Superintendent - Operations reports directly to the Assistant Station Manager (O&M) and is responsible for diiecting and coordinating station operations and fuel handling activities in accordance with approved plans, programs, licenses, Technical Specmcations, and good operating practices. He is responsible for identifying deviations from the Technical Specifications and Facility Operating License (FOL) and for reporting any unusual occurrences in connection with station operations to the Assistant Station Manager (O&M or NS&L).

The Superintendent - Operations is also responsible for: 1) development and implementation of uniform operating policies and procedures, 2) implementation of on-the-job training for Operations personnel, 3) ensuring that each shift is adequately staffed and sufficient back-up personnel are available, 4) ensuring that all required operating data is properly recorded and retained as appropriate, and* 5) being a participating member of the SNSOC.

17.2-6

REVISION 25 1/96

... ~~.,

.,~ "**.l SPS UFSAR b.1.1 Supervisor Shift Operations

. The Supervisor Shift Operations reports to the Superintendent - Operations and provides direct supervision to the.Shift Supervisors, operational input to the SNSOC, and identifies any deviations from the Technical Specifications or any unusual events.

The Supervisor Shift Operations must p*ossess a valid Senior Reactor Operator (SRO) license, and may only be relieved by an individual who possesses a valid SRO lic~nse.

This position fulfills the function* of the "operations manager" as described in ANS 3.1 (12/79 Draft).

b.2 Superintendent Maintenance The Superintendent Maintenance reports directly to the Assistant Station Manager (O&M) and is responsible for directing and coordinating the maintenance activities at the station. He is responsible for. 1) ensuring that station facilities and equipment are maintained in accordance with regulatory requirements and station procedures, 2) the development and implementation of uniform policies and procedures for installation, maintenance, and repair of station equipment and systems, 3) ensuring maintenance tasks will be performed in a timely and efficient manner, and 4) participating as a member of the SNSOC.

b.3 Superintendent Outage & Planning The Superintendent Outage & Planning reports directly to the Assistant Station Manager (O&M). He is responsible for the overall planning and scheduling of maintenance and maintenance-related work activities such that safe and reliable plant operation is optimized. The Superintendent Outage &

Planning is responsible for detailed maintenance planning to support scheduled outages being completed as needed.

He is also responsible for the execution of outages, maintenance of plant equipment history, and monitoring of station performance.

17.2-7

REVISION 25 1/96 SPS UFSAR

,, c. Assistant Station Manager (Nuclear Safety and Licensing)

Responsible to the Station Manager for directing and coordinating nuclear safety issues at the station. The Assistant Station Manager (NS&L) is the Chairman of the Station Nuclear Safety and Operating Committee (SNSOC) and conducts periodic meetings to ensure compliance with station technical specifications, manage licensing activities within the station, interface with Corporate management on operating experience and licensing issues, manage station procedures, administer the station environmental compliance program, and manage station emergency plan activities. Tile Assistant Station-Manager (NS&L) is independent of cost and scheduling concerns associated with operations, maintenance, and modification activities.

  • He is is responsible for maintaining information on industry operating experience, being cognizant. of licensing and regulatory issues, administering the Commitment Tracking System (CTS), administering the nuclear safety assessment and Shift Technical Advisor (STA) programs, administering the Station Emergency 'Plan, ensuring adequate training for station employees regarding emergency preparedness, and coordinates the station quality inspection program.
d. Superintendent Site Services Responsible to the Station Manager for directing all aspects of

( *.r-._..

assigned projects including coordination of activities with station management, engineering, and construction. Support activities such as accounting, procurement planning, scheduling and cost control are also included in these responsibilities.

e. Supeiintendent Radiologicai Protection

~e.sponsible to the Station Manager for administering the Radiological Protection Program at the station. Responsibilities include:

1) monitor the radiological effluent programs and personnel radiation protection programs, 2) maintain records of radiological exposures for all persons working or visiting within the station's restricted area, 3) ensure regular surveys *of the station, 4) maintain records of background radiation levels, and 5) check all radioactive. material releases and shipments from station and maintain appropriate records. The Radiological Protection group is responsible for determining the radiation levels of all work areas, and posting, as needed, areas where sources of radiation exist.

Additionally, the Superintendent Radiological Protection is also responsible for managing the primary and secondary plant chemistry programs and for coordinating activities related to non-radiological environmental protection.

17.2-8

REVISION 25 1/96 SPS UFSAR.

    • The Superintendent Radiological Protection directs the activities of his group to minimize the exposure of station personnel to excessive doses of radiation and to prevent the spread of
  • radioactive contamination.

All activities in these areas are coordinated with other station groups to ensure full awareness of

. problems through implementation of the station ALARA program.

The Superintendent Radiological Protection also participates* as a member of the SNSOC.

f.. Supervisor Administrative Services The Supervisor Administrative Services. reports to the Station Manager and is responsible for managing the activities related to administrative tasks for smooth station operation. These tasks include: planning and budget, station records management, station safety and loss prevention, fire protection, and medical assistance.

,.9* Station Supervisory Personnel Responsible directly to the Station Manager through their respective superintendent$, for implementing the operational quality assurance program requirements applicable to their specific areas of responsibility.

h. Station Staff

. It is the responsibility of each member of the station staff to adhere to the provisions contained in the operational quality assurance program when performing their work tasks to assure quality workmanship.

Personnel with unescorted access statlis shall receive training (Nuclear Employee Training) in the use of and

  • adherence to the operational quality assurance program.
  • C.. Vice President - Nuclear Engineering and Services Responsible to the Senior Vice President - Nuclear and has corporate responsibility for long-term nuclear operations support activities related to engineering, finance and business, personnel training, and emergency planning.

As such, he has responsibility for the system level implementation of the requirements established by the Operational Quality Assurance Program for the nuclear power stations.

17.2-9 I.

REVISION 25 1/96 SPS UFSAR D. *.-Manager-Nuclear Security and Administrative,services The Manager - Nuclear Security and Administrative Services is

. responsible to the Senior Vice President - Nuclear for Nuclear Plant Security, Personnel/Human Resources, Nuclear Plant Access Programs, and Fitness for Duty.

Other responsibilities include: providing staff support to the Senior Vice President - Nuclear and coordinating international information exchange activities.

E.

Manager-Nuclear Oversight The Manager-Nudear Oversight is responsible to the Senior Vice President - Nuclear for assuring compliance with the Operational Quality Assurance Program for nuclear operations and associated support activities. The Manager - Nuclear Oversight may make recommendations to the Nuclear Organization's management. If he disagrees with any action. taken by the Nuclear Organization and is unable to obtain resolution, the Manager - Nuclear Oversight shall bring the matter to the attention of the Senior Vice President - Nuclear who will determine the final disposition.

1. Director-Nuclear Oversight (one at each site)

The Director - Nuclear Oversight is responsible to the Manager -

Nuclear Oversight for assuring compliance with the operational quality assurance program for the nuclear power stations through internal audits.

The Director - Nuclear Oversight may make recommendations to the station management. If he disagrees with any actions taken by the station management and is unable to obtain resolution, the Director* Nuclear Oversight shall notify the Manager -

Nuclear Oversight and the Vice President - Nuclear Operations.

2.
  • Supervisor - Quality (Vendor Programs)

The Supervisor - Quality {Vendor Programs) is responsible to the Manager -

Nuclear Oversight for assuring compliance with established vendor Quality Assurance Programs.

This is accomplished through scheduling and conducting triennial external audits, annual vendor Quality Assurance Program evaluations, reviewing audits conducted by external organizations {e.g., other utilities and NUPIC), and maintenance of the Safety - Related Vandorn List and the Commercial Grade Vendors List.

17.2-10

}',,,.

,.3.

  • Staff Quality Specialist (Audit Coordinator)

The Staff Quality Specialist (Audit Coordinator) is responsible to the Manager - Nuclear Oversight tor assuring compliance with the Operational Quality Assurance Program, administration of the internal audit program, and interfacing with station Nuclear Oversight personnel.

17.2.1.3 Organization Each nuclear pow.er station's Technical Specifications contain the company's organizational requirements for facility operation and corporate management. Additionally, duties and responsibilities of key positions within the nuclear organization are further defined in the appropriate administrative controls.

17.2-11

-REVISION 25 1/96 SPS UFSAR

'17.2.2 QUALIT¥ ASSURANCE PROGRAM 17.2.2.1 General Description Jhe objective of the Company Quality Assurance Program for operating nuclear power stations is. to comply with the criteria as expressed in 1 O CFR 50, Appendix B, ~s amended, and with the quality assurance program requirements for nuclear power plants as referenced in the Regulatory Guides and ANSI Standards as listed in table 17.2.0. This program, its policies and procedures are described herein: the Topical Report {VEP-1-SA) (entitled Operational Quality Assurance Program);

the Nuclear Operations Department Standards (NODS); and the corporate and station procedures.

. This program applies to those quality-related activities that involve the functions of

        • safety-related structures, systems, and components associated with the operation,
  • .. *maintenance and modification of nuclear power stations and those non safety-related

. components described in the UFSAR. Designated modifications may be performed

  • .:.under a contractor's Quality Assurance Program approved by the Company's Quality
Assurance Program. The contractor's Quality Assurance Program when used for modifications will comply with the criteria expressed in 1 O CFR 50, Appendix B, as

,.amended,. and with,the Regulatory Guides and ANSI Standards as listed in Table

, 17.2.0.

The goal of this program is to assure the safe, reliable and efficient operation of the nuclear power station in accordance with sound engineering principles.

The program provides written.. policies, standards, procedures, and instructions covering engineering,,design,. procurement, modifications, periodic surveillance, testing, and maintenance after the systems have been installed, checked and turned over to the Company for operation. Nuclear Operations Department (NOD) policies and standards establish commitments to the Operational Quality Assurance Program.

Detailed procedures and instructions are issued by the station in accordance with and to meet the requirements of their Technical Specifications for administrative, normal operation, periodic testing, abnormal and emergency conditions.

Audit and inspection programs have been implemented to assure that these procedures are being correctly applied.

Nuclear Oversight personnel, both station and corporate, report through a line of management completely separate from operational and production management and influences, and fulfill the following three-part role:

1. Audit to ensure that the overall operation of the nuclear power station is carried out in accordance with Technical Specifications, applicable codes and standards, NRC guides and regulations, company. policies and commitments.
2. Serve as a management tool for station and system management personnel, illuminating problem
areas, detecting
trends, and providing recommendations regarding solution of problem areas when applicable.

17.2-12

REVISION 25 1/96 SPS UFSAR

3. Provide all levels of management with an independent source of information regarding the quality aspect of station operations, maintenance and modification activities.

Differences of opinion between Nuclear Oversight personnel and other departments are resolved by the cognizant Manager and the Director - Nuclear Oversight or are

,

  • forwarded through normal administrative chains of both individuals for resolution at

\\ the executive level.

Final decision-making authority rests with the. Senior Vice

~ President-Nuclear.

  • Nuclear Oversight conducts audits in accordance with the Operational Quality
Assurance Program and performs other duties as directed by the Manager - Nuclear

\\Oversight. Nuclear Oversight representatives have access to all areas of the station at

  • any time deemed necessary for audits and activities related to quality.* They have access to station records required for in-depth auditing of station operations, including
  • ,* confidential personnel records (but only to the extent necessary to verify personnel qualifications or other information related to quality).

. *<;,Station personnel.assigned.to conduct assessments and inspections in accordance

  • .,*with the Operational Quality Assurance Program have access to all areas of the station necessary to accomplish those activities.

. 17.2.2.2 Quality Assurance Program

.The Company Operational Quality Assurance Program is displayed in a point-by-point

.::'comparison to Appendix B, 10 CFR-50 in Table 17.2.1, which follows.

17.2-13

REVISION 25 1/96 SPS UFSAR 17.2.2.3 Identification of Structures, Systems, and Components Safety related structures, systems, and components are identified i_n the UFSAR. The portions of these structures, systems, and components that are within the scope of the -Operational Quality Assurance Program are* further identified in the respective Q-List for North Anna and Surry Power Station.

17.2.2.4 Periodic Review of the Operational Quality Assurance Program Audits of activities required by the Operational Quality Assurance Program will be conducted at least once per 24 months. These audits are performed under the cognizance of the Management Safety Review Committee.

  • -1..7.2.2.5 Qualification of Nuclear Oversight Personnel The Manager - Nuclear Oversight shall have a four-year accredited engineering or science degree or equivalent with a minimum of ten years experience

'. _ related to electric power generating facilities. At least five years of overall experience

' shall have been,in"a supervisory capacity, two years of which should have involved
  • quality assurance related matters.

The Director - Nuclear Oversight shall have a four-year accredited engineering or science degree or equivalent with a minimum of eight years experience related to electric power generation facilities, two years of which involve experience in nuclear power stations. At least four years of overall experience shall have been in a supervisory capacity, two years of which should ha:Ve involved quality assurance related matters.

The Supervisor - Quality (Vendor Programs) shall have a four-year accredited engineering or science degree, or equivalent with a minimum of two years overall experience or equivalent training.in power plant operations is a prerequisite with at least one year of this experience involved in nuclear power station quality assurance program implementation.

The Staff Quality Specialist (Audit Coordinator) shall have a four - year accredited engineering or science degree, or equivalent with a minimum of two years overall experience or equivalent training in power plant operations is a prerequisite with at least one year of this experience involved in nuclear* power station quality assurance program implementation.

Replacement personnel in the key positions listed will meet or exceed the

  • applicable requirements of ANSI/ANS 3.1 {Draft 12/79) as clarified in Table 17.2.0.

17.2-14

REVISION 25 1/96 SPS UFSAR 17.2.2.6 Qualification of Other Support Personnel The Quality Inspection Coordinator shall have a four-year accredited

. ' engineering or science degree, or equivalent with a minimum of two years overall experience or equivalent training in power plant operations. At least one year of this experience shall be involved in nuclear power station quality assurance program implementation.

The Nuclear Training representative responsible for certifying maintenance and modification inspection personnel shall have a four-year accredited engineering or

'. science degree, or equivalent wUh a minimum of two years overall experience or

  • equivalent training in power plant operations. At least one year of this experience shall be involved in nuclear power station quality assurance program implementation.

The Supervisor - Quality (Vendor Surveillance) shall have a four-year accredited engineering or science degree, or equivalent with a minimum of two years overall experience or equivalent training in power plant operations. At least one year

}of.. this. experience,.shall be involved.in nuclear power station quality assurance
  • program implementation.

Replacement personnel in the key positions listed will meet or exceed the applicable requirements of ANSI/ANS 3.1 {Draft 12/79) as clarified in Table 17.2.0.

17.2.2.7 Certification of Nuclear Oversight Personnel The certification of Nuclear Oversight personnel is accomplished in accordance with the Quality Assurance Certification Program. This program provides for the certification and recertification of auditors and lead auditors.

The program outlines the qualification and certification requirements for personnel and requires.the individual to be certified prior to performing specified

':.audit functions. Nuclear Oversight management has the responsibility to certify audit "personnel.

17.2.2.8 Certification of Other Support Personnel The certification of maintenance and modification inspection personnel [i.e.,

Quality Maintenance Team {QMT) and station Quality Control inspectors)], Material Verification personnel, Vendor Surveillance personnel, Fuel Accountability and Inspection personnel, and lnservice Testing [Visual Test * {VT)] personnel is accomplished in accordance with the approved certification programs.

These programs outline the qualification and certification requirements of personnel and require the individual to be certified prior to performing specified functions.

Nuclear Training has the responsibility to tr:ain, qualify, and certify maintenance and modification inspection personnel.

17.2-15

REVISION 25 1/96 SPS UFSAR 17.2.3 DESIGN CONTROL Nuclear Standards describe.the design control program.

Measures are

    • ***"established to assure that applicable regulatory requirements and the nuclear power station design bases are correctly translated into the Company specifications, drawings, procedures, and instructions applicable to design changes and/or modifications for the operating nuclear power ~tation.

All design changes and/or modifications to safety-related structures, equipment, systems and components described in the UFSAR are reviewed, approved, and acted upon by the Station Nuclear Safety and Operating Committee in accordance with their responsibilities and functions as referenced in the Technical Specifications. The Management Safety Review Committee is responsible for ensuring that independent

  • reviews are performed for safety evaluations associated with design changes

. approved by the Station Nuclear Safety and Operating Committee. The responsibility for the development, identification of requirements, monitoring, and implementation of an effective design control program is delegated to the Vice President - Nuclear Engineering and Services with input as appropriate from the Station Manager and

., operations. personnel..

The Nuclear Design Control Program (NDCP), delineates procedures that assure design changes, including field changes, are subject to design control measures commensurate with those applied to the original design and the applicable specified design requirements. These procedures assure that design basis, regulatory requirements, codes and standards are correctly translated into specifications, drawings, procedures, or instructions for those structures, systems and components classified as safety-related in the UFSAR and Q-List. The NDCP provides for verifying or checking the adequacy of design, such as by the performance of design reviews, by the use of alternate or simplified calculational methods, or by the performance of a suitable testing program. When a testing program is solely used to test the adequacy of a design, the test wiil be conducted under adverse design conditions.

The provisions of this section assure that the verifying or checking process is performed by individuals other than those who performed the original design. These individuals are identified and their authority and responsibility is described. The NDCP also identifies the design documents that are required to be reviewed and the personnel responsible for their review and revisions, to assure that design characteristics can be controlled, inspected and tested, and that inspection and test criteria are identified. Design change documents and revisions thereto are distributed to responsible supervi&-ors to determine whether revisions to controlled design and operating documents are necessary.

Design documents and reviews, records and changes thereto are collected, stored and maintained in a systematic and controlled manner.

The NDCP establishes measures for the selection and review for suitability of application of materials, parts, equipment and processes that are essential to the safety-related functions of the systems, structures and components. These measures include the use of valid and applicable industry standards and specifications, materials and prototype hardware testing programs, and design reviews. In the event of a design modification to a system which is safety related, engineering studies 17.2-16

REVISION 25 1/96 SPS UFSAR-are initiated to evaluate parts, equipment, processes, and material suitability for repair of such equipment or components; previously approved items are used without further

  • review.
  • Previously approved materials, parts or components used for a different
  • application are reviewed for suitability prior to approval for their new application.

Quality measures are assured through all levels of the design control program by the design control organization, station and Corporate support organizations, and the Station Nuclear Safety and Operating Committee. Any errors or deficiencies noted

. in the design process are documented on the design change forms and subsequently

.

  • corrected.

Procedures for design controls,* analysis, and reviews have as their basis the

    • applicable portions of documents referenced in the Nuclear Design Control Manual, and include ANSI N45.2.11 - 1974 as modified in Table 17.2.0.

The Nuclear Design Control Program Instruction Manual for Architect/Engineers establishes procedures to describe the design interface between the Cornpany.and contractors for the review, approval, release, distribution, arid revision of documents involving design interfaces.

Suitable design controls are applied to such disciplines as reactor physics; seismic stress, thermal, hydraulic, radiation and accident analysis, compatibility of materials; and accessibility for inservice inspection, maintenance and repair. Designs are reviewed to assure that (1) design characteristics can be controlled, inspected,

>:and tested, and (2) inspection and test criteria are identified.

Changes to non safety-related structures, systems, and components will be controlled in accordance with applicable procedures and to meet the requirements, where applicable, of 10 CFR 50.59.

17.2-17

REVISION 25 1/96 SPS UFSAR 17.2.4 PROCUREMENT DOCUMENT CONTROL Nuclear Operations Department Standards and their sup*porting procedures

  • describe the program for completing procurement documents including review, approval, document control, and change control. In addition, references to procedures that govern the actions of Nuclear Oversight and Vendor Surveillance are made which include provisions for access to the suppliers' facilities and records, for source inspection or audit, and qualification of vendors prior to the initiation of quality relaled actions when the need for such inspection and/or audit has been determined. This program also provides for records to be prepared, maintained, made available for review, or delivered to the Company prior to use or installation of the hardware, such as drawings, specifications, procedures, procurement documents, inspection and test records, personnel and procedure qualifications, material, chemical and physical tests
  • results, an the identification of quality assurance requirements applicable to the items or services purchased, including sub-tier procurement requirements when required.

Policies and standards are established in the Nuclear Department Standards Manual to ensure that procurement documents reference all actions required by a

. supplier in accordance.with the applicable codes, specifications, and drawings.

. -~.

Procurement documents incorporate the design basis technical and quality requirements including the applicable regulatory requirements, component and material identification requirements, drawings, specifications, codes and industrial

  • ***standards, test and inspection requirements, and special instructions for special procedures such as welding, heating treating, nondestructive testing and cleaning as

. applicable.

Procurement documents for spare or replacement parts of safety-related structures, systems and components are subject to technical and quality controls at least equivalent to those used on the original equipment.

Procurement documents are prepared, reviewed, and approved as delineated in administrative controls.

Copies of procurement documents, or equivalent documents such as Receiving Reports or Requisitioner 1s Purchase Orders, are retained and are available for review.

17.2-18

REVISION 25 1/96 SPS UFSAR 17.2.5 INSTRtJCTION

S. PROCEDURE

S, AND DRAWINGS As required by the individual unit's Technical Specifications, detailed written procedures are established, approved, implemented, and maintained.

Other activities affecting quality of structures, systems, and components within the scope of 1 O CFR 50 Appendix B are prescribed by documented instructions, procedures, or drawings of a type appropriate to the circumstances. These activities are accomplished in accordance with these instructions, procedures, or drawings.

Applicable instructions, procedures, or drawings include tor reference appropriate

.. qualitative and/or quantitative acceptance criteria for determining that important

/' activities have been satisfactorily accomplished.

Administrative procedures describe the requirements for developing, reviewing, approving, and controlling procedures used for testing as well as corrective maintenance, operating, design change implementation, administrative, and other activities performed at the power station. These requirements include references, prerequisites, precautions, limitations, manufacturers specifications, check-off lists,

.. and.acceptance crite,ria (as appropriate). When applicable *the acceptance limits and

-~ requirements contained in the design and procurement documents constitute a portion of the acceptance criteria referenced and contained in written testing procedures.

Changes to procedures require an Activity Screening to be performed before a change can be implemented. The Activity Screening includes criteria the preparer must consider to determine if a safety evaluation is required for a proposed change.

  • . Procedure changes that require a safety evaluation are reviewed by the Station Nuclear Safety and Operating Committee (SNSOC) which serves as the onsite review

. group. Procedure changes that do not require a safety evaluation as determined by

  • the* Activity Screening are not required to be reviewed by SN SOC, but still require
  • independent review and approval by a Senior Reactor Operator and cognizant

.:management prior to implementation. The above requirements are applicable to both

.*. intent and non-intent procedure changes.

At its discretion, SNSOC may review

.;:'procedure changes that do not require a safety evaluation in lieu of a Senior Reactor

,.,Operator.

New procedures and procedure revisions are also reviewed using an Activity Screening to determine if a safety evaluation is required. If the procedure is new or if a revision requires a safety evaluation, the procedure is reviewed by SNSOC.

Revisions that do not require a safety evaluation are reviewed by cognizant management prior to implementation. Due to the numerous programmatic reviews that are entailed in the preparation of new and revised procedures changes, a Senior Reactor Operator review is not mandatory. At its discretion, SNSOC may review

.procedure revisions that do not require a safety evaluation.

17.2-19

REVISION 25 1/96 SPS UFSAR 17.2.6 DOCUMENT CONTROL

~ Measures are established and documented within the operating nuclear power stations and at Innsbrook Technical Center describing the control of documents, such as procedures, instructions, and drawings, to provide for their review, approval, and issue, and changes thereto, prior to release and to assure they are adequate and the quality requirements are stated. Provisions call for, among other things, (1) the review and approval of all new station procedures and design changes prior to release, *the review and approval of all changes/revisions to station procedures and all proposed changes or modifications to plant systems or equipment that affect nuclear safety by the Station Nuclear Safety and Operating Committee, (2) policy and procedures for issuance of and changes to station drawings and approval of changes, and *(3) the maintenance and distribution of these procedures. Normally changes to documents are reviewed and approved by the same organizations that performed the original review and approval; however, this responsibility may be delegated to other qualified responsible organizations. Approved changes are incorporated into procedures and drawings and other appropriate documents associated with the change. Procedures and drawings and changes thereto are processed, distributed and controlled. The

~- station maintains a record of all holders of procedures and *drawings and an index of

  • all procedures and drawings, listing the current revision date. Instructions require that a copy of the appropriate procedure be available at the activity location prior to the commencement of that activity. These measures are addressed in the Technical Specifications and Administrative Procedures for each station.

Administrative procedures list certain documents that require strict administrative control for distribution, revision, and routing. These documents are categorized as "Controlled Documents."

Examples of controlled documents are:

Station Procedures, Station Drawings, and the Precautions, Limitations, and Setpoint Document. Also set forth are the distribution and controlling procedures for design and procurement documents.

Maintenance and modification inspection activities ensure that current procedures are used to accomplish work.

17.2-20

REVISION 25 1/96 SPS UFSAR

  • 17.2.7 *coNTROL o*F PURCHASED MATERIAL EQUIPMENT, AND SERVICES An evaluation of suppliers is performed prior to contract award, except in 1,,
    • 'emergency situations where an item or service is needed to preclude development or

' deterioration of an unsafe condition at the plant, by one or more of the following: (1} A review of the suppliers capability to comply with the elements of 10 CFR 50, Appendix B that are applicable to the type of material, equipment, or service being procured, (2)

A review or previous records and performances of suppliers who have proviaed similar articles of the type being procured, (3) A survey of the supplier's facilities and quality. assurance program to determine his capability to supply a product or service

.. which meets the design, manufacturing, and quality requirements, or (4) A review of

., *qualification information supplied by anothef utility or outside organization.

Surveillance of suppliers during fabrication, inspection, testing, and shipment of materials, equipment, and components is planned and performed in accordance with written procedures to assure conformance to the purchase order requirements as

"".applicable. These procedures provide for:

a. Instructions that specify the characteristics or processes to be witnessed, inspected.. or, verified, and accepted; the method-*of surveillance and the extent of documentation required; and those responsible for implementing these instructions. Surveillance shall be performed on those items where verification of procurement requirements cannot be determined on receipt.
b. Audits and/or inspections which assure that the supplier complies with all quality requirements.

Administrative procedures describe the requirements for controlling purchased material, equipment, and services including commercial grade items for use on safety-

. related structures, systems, equipment, and components. The requirements applied to

. spare and replacement parts* are at least equivalent to those applied to the original parts.

Inspections and surveillance of suppliers of nuclear *safety - related items is performed under the direction of the Vice President - Nuclear Engineering and Services. The results of these actions are documented and filed.

The periodic inspections assure that applicable material and equipment received at the station meet the requirements of the specifications, purchase orders, code, drawings, or other purchasing documents.

This assurance includes the,review of documentation

received, physical inspection, cleanliness, packaging, marking or functional testing, as required. Purchased items are normally under the control of the "on-site" organization.

Th is organization is authorized to.contact system organizations and NSSS, A/E contractors and subcontractors through the auspices of system representatives for assistance as required. Verification of these activities is accomplished under the direction of the Manager - Nuclear Oversight.

Periodic evaluations of procurement history of the suppliers are performed by Nuclear Oversight to verify continued supplier capability.

17.2-21 I

J

REVISION 25 1/96 SPS UFSAR Documentation concerning the quality of material, components,

  • and equipment

. received is reviewed by the Nuclear Engineering and Services representative for

  • conformance with the Purchase Requisition and Purchase Order.

The procurement of nuclear fuel is controlled in accordance with procedures that have been developed by the Nuclear Engineering and Services Organization to address the requisite quality attributes of this function. Verification of this activity is performed under the supervision of the Director - Nuclear Oversight.

17.2-22

REVISION 25 1/96 SPS UFSAR 17.2.8 IDENTfFICATION AND CONTROL OF MATERIALS, PARTS, AND COMPONENTS

  • ". Installed components at the nuclear power station are adequately identifi~d and
  • .,. substantiated with documented records* by the Architect - Engineer and the NSSS Vendor during the construction phase of the station. These identifications and records are maintained in the station files.

Replacement materials, parts, and components including partially fabricated subassemblies are adequately and properly identified to allow control and traceability to pertinent quality assurance records such as drawings, specifications, purchase orders, manufacturing and inspection documents, deviation reports, and physical and

chemical mill test reports. The identification system is consistent, as practical, with that

- used during the construction of the station, with similar identification used during design change activities. The location and method of identification do not affect the

- function or quality of the item being identified. Verification of correct identification of safety-related materials, parts, and components is required and documented prior to the release for fabrication, assembling, shipping, or installation.

Maintenance and modification inspection activities ensure, on a random basis,

  • that materials, parts, and components utilized at the nuclear station are appropriately identified and controlled.

17.2-23

REVISION 25 1/96 SPS UFSAR 17.2:9. CONTROL OF SPECIAL PROCESSES The control of special processes is maintained and implemented through the use of procedures, technique sheetsi'travelers and inspection verification reports, and personnel qualified in accordance with the applicable codes, specifications, and standards for the specific work. In instances where the Company assigns such work to contractors, the contractor must submit their procedures and personnel qualifications to the Company for approval prior to the start of work.

Special processes include, for example, those involving welding, heat treating, nondestructive testing, cadwelding, removal of undesirable substances during shop and site cleaning, degreasing and flushing, and verification of wall thickness of valves and other cast components important to nuclear safety.

The Company conducts inspections of work involving special processes to assure that procedures and personnel are properly qualified and their workmanship is in compliance with applicable specifications, codes, and standards.

Records otprocedures, equipment, and personnel qualification are maintained

  • and kept current in accordance with the provisions of Section 17.2.17 herein.

17.2-24

REVISION 25 1/96 SPS UFSAR 17.2.10 INSPECTION Inspection procedures for those activities affecting quality have been established. These procedures govern the inspection and documentation of activities

  • . relating to repairs, modifications, and changes made to.safety related systems, structures, and components. Written maintenance procedures are provided which include inspection hold points.

Examinations, measurements, or tests of materials or components associated with safety-related equipment and systems are performed for each work operation,

. where necessary, to assure quality.

If inspection is impossible or inappropriate,

.*,. indirect control by monitoring methods, equipment, and personnel is provided;* Both

  • methods are provided when control is inadequate without both.

The station maintenance procedures are reviewed under the cognizance of the

  • .. Assistant Station Manager (Nuclear Safety and Licensing) or designee to determine the need for an independent inspection and the degree and method if such an inspection is required. Modification procedures are reviewed by the design authority

_Jo determine the "need for an independent inspection consistent with administrative

'.*::procedures and engineering specification requirements.

Examinations,

  • measurements, or tests that require witnessing are identified as "inspection hold" points in procedures. The inspection performed at a hold point is specific in nature; quality characteristics and acceptance/rejection criteria are included or qualitative criteria such as operability checks, compliance with procedural steps, or cleanliness instructions are specified. The inspection is documented by signature or initials on the written procedure form.

Maintenance and modification inspection personnel perform physical inspections at random intervals to ensure quality requirements are met. These checks are performed as the conditions of the maintenance warrant. These personnel and other inspectors are qualified in accordance with codes and standards as applicable to the function they are performing.

The inspection program requires that inspectors be assigned as appropriate for the activity being inspected. An inspector may be a member of the organization performing the activity. However, they must be qualified and shall not be the person performing the activity or the supervisor directly responsible for the activity.

Maintenance and modification inspection personnel are under the administrative direction of the Quality Inspection Coordinator when performing Quality Control inspections. Personnel so assigned shall become familiar with the procedure being used and other pertinent documents such as technical manuals and drawings prior to performing the inspection.

17.2-25

REVISION 25 1/96 SPS UFSAR Personnel responsible solely for the conduct of nondestructive examination are qualified to SNT-TC-1A as referenced by Table IWA-1600-1 of the applicable Code. In

. addition, personnel who conduct.inservice or preservice examinations mee.t the

**- additional and/or alternative qualification requirements specified by IWA-2300 for the applicable examination method and qualification level. Maintenance and modification inspection personnel, Material Verification personnel; Fuel Accountability. and Inspection personnel, and Vendor Surveillance personnel meet the qualification requirements of ANSI N45.2.6-1978, as clarified in Table 17.2.0 under NRC Regulatory Guide 1.58. The inspectors' qualifications are periodically reviewed for recertification.

Generally, all physical inspections are under the control of the on-site organization. However, the Station Manager is authorized to request assistance as required from Corporate support organizations.

The inspection of nuclear fuel and related items is controlled in accordance with procedures that have been developed by Nuclear Engineering and Services to address the requisite quality attributes of this function.

Additionally, inspection activities pertaining to Design Control (Section 17.2.3);

Procurement Document Control (Section 17.2.4); Test Control (Section 17.2.11);

Nonconforming Materials, Parts, or Components (Section 17.2.15); and Corrective Action (Section 17.2.16) shall be controlled in* accordance with provisions established for this function in the referenced sections contained herein.

17.2-26

'*-./

REVISION 25 1/96 SPS UFSAR

  • 17.2.11 TEST,CONTROL The test program described in the Technical Specifications assures that safety-

.* related structures, systems, and components will perform satisfactorily when required.

. Written "Periodic Test" procedures for this program are reviewed and approved as specified in the individual unit's Technical Specifications. These test procedures include or reference:

(1) The requirements and acceptance limits contained in applicable design and procurement documents.

(2) Test prerequisites such as the availability of adequate and appropriate equipment and calibrated instrumentation; trained, qualified, and licensed or certified personnel; the completeness of the item to be tested; suitable and controlled environmental conditions; provisions for data collection and storage.

(3) Instructions for performing the test.

(4) Inspection points as appropriate.

(5) Acceptance and rejection criteria.

(6) Methods of documenting or recording test data and results.

The Periodic Test Program provides for testing of instrumentation and electrical equipment in the categories of (1) instruments installed as listed in the Technical Specifications, (2) installed instrumentation used to verify Technical Specification parameters, and (3) installed safety-related instruments and electrical equipment that provide an active function during operation, shutdown, or abnormal conditions (i.e.,

vice being designated safety-related solely because the instrument is an integral *part of a pressure retaining boundary).

This instrumentation shall be in a calibration program. This program provides, by the use of equipment history data, status, records, and performance schedules, for the date that calibration is due and indicates the status of calibration. The identity of person(s) performing calibration is provided on the calibration documents.

Testing of modifications is done in accordance with procedures developed within the Design Change Program described in Section 17.2.3 of this report.

Testing upon completion of maintenance is done in accordance with Maintenance Procedures developed as described in Section 17.2.5 of this report.

17.2-27 I*

REVISION 25 1/96 SPS UFSAR 17.2.12 CONTROL OF MEASURING AND TEST EQUIPMENT _____ _

A program has been established and documented in administrative proce~ures

'"that describes the calibration technique and frequency, maintenance, and control of all

  • **-- "Measuring and Test Equipment" (portable instruments, tools, gauges, fixtures, reference and transfer standards, and nondestructive test equipment) which are used in the measurement, inspection, maintenance, and monitoring of safety-related components, systems, and structures.

Measuring and test equipment does.. not

__ include: measuring equipment used for preliminary checks or utility troubleshooting

  • where accuracy is not required. There is also no intention to imply a need for special calibration and control measures of rulers, tape measures, levels, and other basic.

tools if normal commercial practices provide adequate accuracy.

Controls for

. measuring and test equipment include the transportation, storage, and protection of 1

__ the equipment; the handling of associated documents giving the status of all items

    • under the calibration system such as maintenance history, calibration test data, and
  • individual log sheets assigned to each device; and the permanent marking of each device by a unique number.

The maintenance, calibration technique, and frequency of calibration of measuring and test equipment utilized in activities affecting quality at the power station are normally performed as specified in the manufacturer's instruction manual or in approved written procedures. In some cases the calibration interval may be assigned or changed based on accumulated experience by trained technicians. The recall system may include provisions for the temporary extension of the calibration due date under certain conditions specified in approved procedures.

If standards are not

,available or there is some special reason that procedures cannot be followed, the modified procedures and/or interval are documented, including justification. In other cases, rather than require calibration at specified intervals, procedures may specify the device be calibrated prior to use, as in the case of torque wrenches or micrometers.

Where permitted by commercially available state of the art equipment, reference standards are no.more than 1/4 the error allowed in the measuring and test equipment calibrated by that standard.

Measuring and test equipment used on safety-related systems or equipment are calibrated utilizing reference standards whose calibration has a known valid relationship to nationally recognized standards, such as the National Institute of Standards and Technology (NIST), or accepted values of natural physical constants.

If no national standard exists, the basis for calibration is documented. Whether the device is calibrated at the power station or at an NIST traceable outside laboratory, one or more stickers are affixed on a conspicuous surface identifying, but not limited to, date of calibration and next calibration due date.

When measuring and test equipment utilized in activities affecting quality are found to be out of calibration an evaluation will be performed and documented concerning the validity of previous tests and the acceptability of devices previously tested.

All previous tests and measurements performed during the current or proceeding calibration cycle shall be redone if the evaluation _so indicates.

Implementation of the measuring and test equipment programs is assured*

_.,through Nuclear Oversight audits and through inspections by the appropriate line

-. organizations during performance of work.

17.2-28

~

REVISION 25 1/96 SPS UFSAR 17.2.13 HANGLING. STORAGE. AND SHIPPING

- Measures have been established in administrative procedures to provide

  • adequate methods by qualified personnel for.the classification. packaging, cleaning, preservation, shipping, storage, and handling of material and equipment received at the station.

These measures, prepared in accordance with design and specification

. requirements, define responsibility, levels of essentiality, degree of receipt inspection, tagging, categories of inspection and their definition, and storage levels for

__ categorized items.

The procedures also control cleaning, handling, storage, packaging, shipping, and preser:.vation of materials, components, and systems to preclude damage, loss, or deterioration by environmental conditions such as temperature or humidity.

Implementation of these measures is verified through inspections by Materials Verification and Vendor Surveillance inspectors.

.:':I,.

17.2-29 *

.i,,

REVISION 25 1/96 SPS UFSAR 17.2.14 INSPEC:::TION, TEST, AND OPERATING STATUS Measures for the identification and documentation of the inspection and test

  • status for items to prevent inadvertent'bypassing of specified inspections and tests are established in administrative procedures and in station operating procedures. These measures define the three general categories *of inspection and test status for items:

Accept, Reject, or Hold. They provide for status identification through the use of stickers, tags, record cards, test records, check-off lists, or logs. The operating status of items and/or equipment is identified through records, checklists, or operational tagging systems that are maintained to indicate the status and authority to operate the item and/or equipment. Operating status is additionally controlled through the normal station operating procedures. The-.application and.. removal of the various status tags, stickers, and other indicators is controlled by Station Procedures.

17.2-30

.--*\\

~ -- "-

REVISION 25 1/96 SPS UFSAR

  • 17.2.15 NONGONFORMING MATERIALS, PARTS, AND COMPONENTS A documented system for -controlling nonconformances observed during receipt

--,. inspection, storage, fabrication and erection, installation, initial and/or acceptance

. testing, or initial operation is established and provides for the preparation, issuing, and distribution of Station Deviation Reports and Discrepant Shipment Reports in accordance with prescribed procedures. These procedures apply to new or reworked

  • materials, parts, or components which possess manufacturer/supplier caused
  • nonconformances.

The identification, documentation, segregation, review, disposition, and

notification to affected organizations of nonconforming material, parts, or components

'are described or referenced in station Technical Specifications, Administrative

. procedures, and/or station operating procedures.

Nonconformance of purchased services are controlled under Section 17.2. 7 Control of Purchased Material, Equipment, and Services; Section 17.2.1 O Inspection; and administrative procedures.

Specifically, instructions require that the individual discovering a nonconformance.identifies, describes, and documents the nonconformance on a Station Deviation Report or a Discrepant Shipment Report in accordance with

  • administrative procedures.

When a nonconforming item is identified, it is placed in the hold area established in the storeroom or other segregated location, if practical, and identified with a hold tag to prevent its inadvertent use. If material is dispositioned as 'reject' the hold tag shall remain attached to the material/component until loaded for departure from site and shall only be removed in accordance with approved procedures by

. authorized personnel at that time.

Hold items may be released on a risk basis following the documented approval

  • of such iisk release by the Station Manager on a Release on a Risk Basis Form: Each risk release is handled on a case basis and depends on the nature of the hold status.

The basis and conditions of.the release are described on the form, including the criteria for clearing the original hold status. Rejected material is not risk released.

A Station Deviation Report or a Discrepant Shipment Report for a nonconfc;>rming material, part, or component dispositioned "accept as is" requires an engineering analysis and approval.

The results of this review and approval are

.documented and become a part of station records.

Should the disposition of a nonconformance require the rework or repair of materials, parts, components, systems, or structures, such rework or repair is reinspected or retested by a method which is at least equal to the original inspection or test method.

The. inspection requirements and the inspection, rework, or repair procedures are documented and become a part of station records.

17.2-31

REVISION 25 1/96 SPS UFSAR The disposition and approval of nonconformances are the* responsibility of the on-site organization. However, the Station Manager has the authority to request assistance as appropriate from Corporate support organizations or from Nuclear I *-

  • - Oversight.

The Station Deviation Reports trends are periodically reviewed for conditions adverse to quality by station management.

In service failures of materials, parts, and components are dispositioned by the use of Deviation Reports and/or Work Orders as described in Section 17.2.16 of this report.

Implementation and verification of the procedures for the control of

  • nonconformances are assured through audits and inspections.

The nonconformances observed during the inspection of nuclear fuel and related items and the disposition of those nonconformances is controlled in

. accordance with procedures that have been developed by Nuclear Engineering and

_ \\Services to address-the requisite quality attributes of this function.

17.2-32

REVISION 25 1/96 SPS UFSAR

  • 17.2.16 CORHECT.IVE ACTION Corrective action measures are established as an integral part ~f the "processing and resolving of nonconformances and failures in service. Through these measures, assurance is confirmed that significant adverse quality conditions are

,, identified, documented, their cause determined, and the corrective actions have been taken that preclude repetition of the adverse quality conditions. Verification of the proper implementation of corrective action measures and close-out of corrective action documentation is assured through the monitoring effort of the station staff and the

.** audits conducted by Nuclear Oversight.

Adverse conditions significant to quality, the cause of the conditions, and the initiation of corrective action are reported to appropriate levels of both offsite and onsite manage*ment by use of Deviation Reports

, and audit findings. If further corrective action is required the appropriate management

  • program for performing, tracking and closing the issue will be used.

Nuclear Engineering and Services maintains a program to evaluate complex design concerns that may lead to adverse quality conditions at the nuclear stations.

The Potential Problem Reporting (PPR) system allows for detailed, multidiscipline

,;;;reviews-oLcomplex,.design concerns that may yield station;deviation reports.

  • Many
  • .. design concerns cannot be determined to be adverse to quality until a detailed design review is performed. The PPR process controls this activity as part of the Nuclear Design Control Program.

The procedures for processing a Deviation Report require that each adverse condition significant to quality be categorized as either requiring a Licensee Event Report, Special Report or NRC Notification or as a nonreportable deviation.

  • Non reportable deviation refers to deviations not reportable to the Nuclear Regulatory Commission. The reporting requirements differ for each of the categories of deviation but require the appropriate levels of management be notified in each case.

Procedures require that corrective maintenance of nuclear safety related material, parts, or components be documented on a Work Order. Maintenance and

. modification inspection personnel are notified prior to the commencement of safety

>related maintenance. Maintenance and modification inspection personnel may then initiate a surveillance program as necessary.

Examples of areas subject to surveillance are (1) the use of approved maintenance procedures, (2) the existence of Radiation Work Permits and proper tagout, if applicable, (3) the existence of required plant conditions, and (4) documentation of Technical Specification requirements. If the

maintenance and modification inspection personnel elect to inspect the work, the surveillance does not have to be performed prior to commencement of work. Also, Nuclear Oversight audits completed Work Orders to *assure maintenance performed was properly documented, maintenance procedures were properly signed off and check lists were completed if applicable, Technical Specification limits were met if applicable, materials used were documented, and Work Orders were being adequately reviewed by appropriate supervisory personnel.

17.2.-33

REVISION 25 1/96 SPS UFSAR Station Technical Specifications require that rework or repair of nuclear safety-related materials, parts, components, systems, and structures be accomplished in accordance with approved written procedures. The procedures for rework or repair of safety-related equipment are approved by the Station Nuclear Safety and Operating Committee to ensure provisions for an adequate inspection of the completed rework or repair. The cognizant supervisor reviews the completed procedures to insure _the I

  • acceptance criteria have been satisfied and for the completeness. of the post-maintenance check-out.

The Quality Inspection Coordinator determines the scope of the required inspection effort on the basis of tne extent of modifications or repair to safety-related

... equipment, systems, or components. For some repairs and modification activities, pre-

.. job briefings held by station personnel in accordance with applicable administrative procedures may be attended by maintenance and modification inspection personnel at the discretion of the Quality Inspection Coordinator. For major evolutions, such as refueling, steam generator modifications, etc., inspection activities will be planned and coordinated as directed by the Quality Inspection Coordinator.

17.2.16.1 Authority to Stop Work Nuclear Oversight and the Quality Inspection Coordinator have the authority, and the responsibility, to stop work in progress which is not being done in accordance with approved procedures or where safety or equipment integrity may be jeopardized. This extends to off-site work performed by vendors furnishing safety-related materials and services to the Company.

17.2.16.2 Imposition of "Stop Work" A.

Nuclear Oversight and the Quality Inspection Coordinator -

The Nuclear Oversight representative or maintenance or modification inspector advises the cognizant supervisor or supervisory personnel to stop work in progress whenever he determines that it is not being conducted in accordance with applicable procedures, instructions, guides, or standards or may jeopardize

  • the safe operation of the station. Nuclear Oversight representatives inform the Director - Nuclear Oversight of the stop work order.

The maintenance or modification inspector informs the Quality Inspection Coordinator and the Director

- Nuclear Oversight of the decisicn to stop work. The Director - Nuclear Oversfght or the Quality Inspection Coordinator then notifies the Station Manager of the decision to stop work because of adverse quality conditions. He shall also notify

  • the Manager - Nuclear Oversight.

17.2-34

REVISION 25 1/96 SPS UFSAR

8.

Station Manager - The Station Manager evaluates the determination to stop work.

j:

  • 1. If he concurs with the decision to stop work, he initiates the necessary corrective action. Only after the discrepancy has been corrected and the corrective action approved by the initiating organization does work resume.
2. In the event the Station Manager does not concur with the decision to stop work, he may order work to resume by notifying the Director -

Nuclear Oversight (who shall.notify the Manager - Nuclear Oversight) and the appropriate *station supervisory personnel in his organization of his decision. He shall also refer the issue to the Vice President - Nuclear Operations for review and approval..

C.

Vice President - Nuclear Operations - The Vice President-Nuclear Operations is responsible for approving or disapproving the Station Manager's decision in those cases where the Station Manager does not concur with the stop work and orders work to resume.

D.

Manager - Nuclear Oversight - The Manager - Nuclear Oversight may refer any concerns he may have concerning the* handling of "stop work" to the Vice President-Nuclear Operations. He may direct imposition of "stop work" whenever he deems such action to be appropriate.

E.

Imposition of offsite "stop work" performed by vendors shall be controlled by appropriate administrative procedures.

17.2-35

REVISION 25 1/96 SPS UFSAR..

17.2.17 QUALITY ASSURANCE RECORDS The requirements and responsibilities for quality assurance records transmittal,

'retention, and maintenance subsequent to completion of work at the power station have been established and are documented in administrative procedures.

Quality Assurance records relating to the operating status of the station and documentary evidence of the quality of items and activities affecting quality *are maintained in accordance with the Technical Specifications and administrative

  • procedures.

These records include plant history; operating logs; principal maintenance and modification activities; Licensee. Event Reports; results of reviews, inspections, tests, audits, and material analysis; monitoring of work performance, qualification of personnel, procedures, and equipment; and other documentation such as drawings, specifications, procurement documents, calibration procedures and reports, deviation reports, and corrective action requests.

Identification and retrievability of these records is facilitated through proper indices and an established basic filing system.

Record storage facilities are constructed, located,.. and secured to prevent the destruction of records by fire, flooding, theft, and deterioration through environmental conditions such as temperature and humidity.

17.2-36

REVISION 25 1/96 SPS UFSAR 17.2.18 AUDITS

.** The system of audits devised to verify compliance with quality related aspects of the power station is described in the station Technical Specifications. Internal audits of selected aspects of operational phase activities are performed with a frequency commensurate with safety significance and in a manner which assures that biennial (2 years) audits of safety related activities are completed. The audits are regul~rly scheduled on a formal preplanned audit schedule. The audit system is reviewed periodically and revised as necessary to assure coverage commensurate with current

. and planned activities. Additional audits may be performed as deemed necessary by

.. management. The scope of the audit is determined by the quality status and safety

      • . importance of the activities being**performed. These audits are conducted by trained personnel not having direct responsibilities in the area being audited and in
  • accordance with preplanned and approved audit plans or checklists.

Nuclear Oversight is delegated the responsibility for conducting periodic internal and external audits. Internal audits are conducted to determine the adequacy of the station's programs and procedures, that they are meaningful, and comply with the overall Quality Assurance Program. External audits determine the adequacy of

An audit includes an objective evaluation of quality related practices, procedures, and instructions; the effectiveness of implementation; and the conformance with policy and directives. An audit also includes the evaluation of work area, activities, processes, and items and the review of documents and records. Provisions are established requiring that audits be performed in those areas where the requirements of Appendix B to 1 O CFR 50 are being implemented. These areas include as a minimum, but are not limited to, those activities associated with operation, maintenance, modification, and repair controls; the preparation, review, approval, and control of design changes, procurement documents, instructions, procedures, and drawings; receiving and plant inspections; indoctrination and training programs; the implementation of the operating and test

  • procedures; and the remaining criteria in Appendix B to 10 CFR 50.

The results of each audit are reported in writing to the distribution delineated in accordance with station Technical Specifications. Additional internal distribution is made to other concerned management levels in accordance with approved procedures.

Management responds to all audits and initiates corrective action where indicated. Where corrective action measures are indicated, documented follow-up of applicable areas through inspections, review, re-audits, or other appropriate means is conducted to verify implementation of assigned corrective action.

17.2-37

REVISION 25 1/96 SPS UFSAR If the Manager - Nuclear Oversight determines the response to an internal audit finding is unacceptable or if a finding response is not received in the time allotted or if corrective action for a finding is not accomplished as indicated on the response, the matter is brought to the attention of the Station Manager or appropriate Corporate Manager for resolution. If the Manager - Nuclear Oversight does not agree with the resolution proposed, he notifies appropriate levels of management in accordance with established escalation procedures. The escalation of external audit issues identified by Nuclear Oversight is controlled by administrative procedures.

The responsibility for analyzing audit reports for trends and effectiveness lies with the Manager - Nuclear Oversight. As trends are discovered or if the effectiveness of the program is in question, the analysis of the Manager - Nuclear Oversight is forwarded to the management level consistent with the seriousness of the problem.

17.2-38

../

REVISION 25 1/96 SPS UFSAR APPENDIX A FIGURES NUCLEAR ORGANIZATION 17.2-39

I I

Vice President Nuclear Operations 17.2.1.2.B MSRC I

I 17.2.1.2.A.1 APPENDIX A NUCLEAR ORGANIZATION FIGURE 17.2.1-1 Senior Vice President Nuclear 17.2.1.2.A I

NOB I

17.2.1.2.A.2 recretary to Senior I

I Regulatory Affairs I Executive I

Advisor I

I Vice President Manager Nuclear Security Nuclear Engineering and Administrative and Services Services 17.2.1.2.C 17.2.1.2.D I

I Manager Nuclear Oversight 17.2.1.2.E

D m

en

~-

1\\)

01 co m

en

""O en C

'Tl en

)>

D

I Assistant Station Manager (O&M) 17.2.1.2.B.1.b Superintendent Operations 17.2.1.2.B.1.b.1 lJ Supervisor Shift j

Open;1tlons 17.2.1.2.B.1.b.1.1 Superintendent Maintenance 17.2. 1.2.B.1.b.2.

Superintendent

._ Outage & Planning 17.2.1.2.B.1.b.3 APPENDIX A NUCLl;AR STATION ORGANIZATION FIGURE 17.2.1-2 i--------- - -- -

Station Manager I

SNSOC I I.._ _ _.

..._1_7-.2-.1-.2-.B-.1-.a-'


.-17-.-2.-1.-2-.B...... 1 I

Secretary L__

'-----'-----'r---

I Assistant Station Manager (NS&L) 17.2.1.2.B.1.c Superintendent Site Services 17.2.1.2.B.1.d 17.2-41 I

Superintendent Radiological Protection 17.2.1.2.B.1.e Director Nuclear Oversight 17.2.1.2.E.1 I

Supervisor Administrative Services 17.2.1.2.B.1.f JJ m

5 (J) 0 z I\\)

01 (J)

"'ti (J)

C "Tl

~

JJ

L

. TABLE 17.2.0 Standard, Requirement or Guide

-;:R~e-g-u71a7to-ry--;G~u-=-id"7e----:-1-::.B:--_--:,:-::,P::-e-rs_o_n_n_e7""1 ::::Q_u_a;-::1 if~ic-a--=ti_o_n _a_n-:d-=T,...ra--=i-n,...in-g.,,..".,,(S,,...e-.c-o-n--=d"""'P,...r-op-o-s-e....,d,...,R,,...e-v""'"is"""io-n-2-, 9~t,,_B.....

O,...) ""E,_n-do_r_s_e-s ""'A..... N""S,...,.l/...,A,....N-S,,...--3-.1-("""D-r-af-t-1-2-/7-9-)--------- ~

The applicability of this guide/standard to other personnel in the Company organization is addressed in other sections of the UFSAR and the U>

Technical Specifications of the individual nuclear facility.

0

____..._-'-..;;_;;."'"=':-"-'"=""_;;_=~~~~=...:.;;:=~--------.,,----,----.,,-------------------------z The Company's Position Conformance Status Justification

_______ __;,..;..;..;;;;.....;;;..;:..;.;..;.c~;.,...;;;_;._;;:..::.;.;~~------------==:.:.:.::=:.=...;==:..-----------__::;::.:::.::.:.:.::::::.::.:::.:.:.. ______ I\\)

The Operational Quality Assurance Program complies with thi~,.guide and standard, with one (1) exception, one (1) clarification and three (3) alternatives. They are:

(1) Exception: With regard to Section 4.2.2 of ANS 3.1 (Draft 12/79) titled Operations Manager. Paragraph C.

Training: The Operations Manager will have or have held a senior operator license.

(2) Clarification: With regard to the term "Bachelor's Degreea as used in the draft the following qualifications may be considered equivalent to a Bachelor's Degree:

A. 6 years of applied engineering experience at a nuclear facility In the area for which qualification is sought, B. 6 years of operational or technical experience/training related to engineering in nuclear power, and C. In addition, experience and training requirements shall be met as delineated.

Clarification and Alternative meet or exceed applicable guides and standards.

For Exception: NRC License Amendrn.ent Nos. 142 and 125 dated December 4, 1990 for North Anna and NRC License Amendment Nos. 151 and 148 dated December 31, 1990 for Surry approved revisions to the Technical Specifications granting relief from Section 4.2.2 of ANS 3.1 (Draft 12/79). The exception allows the Superintendent - Operations to hold or have previqusly held a Senior Reactor Operator License for the facility or a similar designed Pressurized Water Reactor plant. The Supervisor Shift Operations will fulfill the Operations Manager requirements of ANS 3.1 (Draft 12/79). This change allows the Superintendent Operations to perform management functions and examine training programs.

For Clarification: ANSI/ANS - 3.1 (Draft 12/79) does not provide a clear alternative to formal educational requirements, but does provide guidance. This guidance was utilized to develop clarification to qualify non-degree holding personnel.

1~2 J~-1986 01 U>

"U U>

C Tl U>

)>

n

\\ **

TABl..E 17.2.0 Standard, Requirement or Guide


:;:.::-:~-::-=------.-~~-;------'----------:::---:-----::::~----------....;._-,---,.,,,--.,..-.a.....------lJ The Company's Position Conformance Status Justification m

(3) Alternative: With regard to Section 4.4.5 of ANS 3.1 (Draft 12/79) titled Quality Assurance.

The Company's* Nuclear Oversight organization will comply with Paragraph 4.4.5 as originally stated in ANSI/ANS 3.1 -

19Property "ANSI code" (as page type) with input value "ANSI/ANS 3.1 -</br></br>19" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process.?8.

(4) Alternative: With regard to Section 4.3.2, Supervisors Not Requiring NRC Ucense, Paragraph b; Experience: At the time of appointment to the position; the supervisor shall have 4 years experience in the craft or discipline he supervises or an equivalent number of years nuclear plant experience in a supervisory position with a Senior Reac:tor Operator's License.

~-

(5) AHernatjve: With regard to Section 5.3.3 of ANSI/ANS 3.1 (Draft 12/79) titled Training for Shift Technical Advisor with Bachelor Degree without an NBC Senior Operator License, Section 3).

The Shift Technical Advisors will observe control manipulations on the simulator as appropriate.

For Alternative: ANSI/ANS 3.1 1978.

Paragraph 4.4.5 is considered to be consistent with the Company experience requirements which are delineated in other areas of this report. Further, the 1978.*

requirement is considered more conservative than the Draft 12/79 ANS Requirement.

For alternative: ANSI Section 4.3.2; Individuals having the specified alternate experience possess a working knowledge of plant activities (e.g., operations, maintenance, I & C, health physics, etc.)

sufficient to perform a broad range of supervisory functions. The individual's day-to-day interaction with the various plant activities has provided him with an understanding of how each activity is integrated into safe and effective plant operations. His combination of SRO training and plant experience is adequate to assure that actions performed by individuals under his supervision are both technically correct and consistent with approved programs and procedures.

For alternative: ANSI section 4.3.2 (Draft 12/79): The performing of control manipulations is riot considered a Shift Technical Advisor task. The primary objective of Shift Technical Advisor simulator instruction is to d~monstrate plant and operator respons*e to given conditions or events, not to develop expertise in control manipulations.

17.2-43 June, 1986 en 0 z I\\)

01 en "t]..

en C

"Tl

~

lJ

I TABLE 17.2.0 Standard, Requirement or Guide JJ


* ~

Regulatory Guide 1.26 - "Quality Group Classification and Standards for Water, Steam, and Radioactive Waste Containing Components of Nuclear Power 00 Plants." (Rev. 3, 2fi6).

o


z T_he_C_o_m_.p_a_n_.y_'s_P_o_s_it_io_n ____________

C_o_n_f_o_rm_a_n_c_e_S_t_a_tu_s ____________

Ju_s_t_ifi_c_at_io_n _______ ~

The Operational Quality Assurance Program complies with thi~,guide with the following clarification:

The Company does not use the specific A, B, C, and D level classification system set forth in this guide. However, the Company followed the requirements of this guide in developing the list of structures, systems, and components for which the program is applicable. The specific listing of items to which the Operational Quality Assurance Program applies Is described in detail in the Q-list for Surry and North Anna Power Stations.

The Company also followed the requirements of this guide in developing the ASME Section XI Class 1, 2 and 3 boundaries for the inservice inspection and testing program.

These claSSfi!S and boundaries are updated for each 1 O year inspection interval.

Clarification meets or exceeds applicable guides and standards.

\\ ';

/)

The Nuclear Design Control Program standards provides the methodology and procedures for determining the quality classification of components. A specific listing of these components is maintained in a document called the Q-list.

11..,-44

.~.1986 f/)..

-0 f/)

C "Tl f/)

)>

D

TABLE 17.2.0

~--r,,

. Standard, Requirement or Guide

_________________________________________________________ jJ Regulatory Guide 1.29 - "Seismic Design Classification" (Rev. 3, 9/78)

.m U>


0 z,

T_he ___ C_o_m_.p __ a_n"""y-s_P_o.;...s_it_io_n ____________ C on

..... f_o_rm

__ a_n __ c_e_S_t __ a __ tu_s ___________

--"-Ju_s_t_ifi;..;;.c_at-io_n.;...._ ______ rn The Operational Quality Assurance Program complies with this guide with the following clarification:

See Generic Statement which prefaces this table with regard to construction related guides, standards and instructions.

Clarification meets or exceeds applicable guides and standards.

Regulatory Guide 1.29 is primarily concerned with the design and construction phase of nuclear power plants. The Company's clarification has been formulated to provide a means of translating design and construction criteria into guidance applicable to operating nuclear power facilities.

17.2-45 June, 1986 co O>

U>

""D U>

C,,

U>

)>

jJ

TABLE 17.2.0 Standard, Requirement or Guide JJ

-=-......,-------------------__;._---------------~--------------------rn Regulatory Guide 1.30 - "Quality Assurance Requirements for the Installation, Inspection, and Testing of Instrumentation and Electric Equipment"

~

.... (B_/_72_.)_. _E_n_do_r_s_es_A_N_S_I N_4_5_._2._4_-_1_9_72_. ________________________________________

0 z*

The Company's Position Conformance Status Justification N


"-J.----------------------------------------------_..;..~~=,;.;;.;..;... ______ Ul The Operational Quality Assurance Program complies with this,,guide with the following clarifications and alternatives:

(1) See Generic Statement which prefaces this table with regard to construction related guides, standards, and instructions.

(2) Section 2.1 - Planning requirements, as determined by station management, will be incorporated into maintenance and modification procedures.

(3) Section:3 - Preconstruct;on Verification: (a) verification is required only for the modification(s) (b) will be implemented with the clarification that "approved instruction manuals" shall be interpreted to mean the manuals provided by the supplier as requirect!?Y the procurement order. These manuals will not be reviewed and approved, per se, by the Company; (c) no special checks will be made by the person withdrawing a replacement part from the warehouse-equivalent controls are assured by compliance with ANSI N45.2.2 as set forth in this table; and (d) will be complied with, as determined by station management as part of the maintenance/modification program.

Clarifications and alternatives meet or exceed applicable guides and standards.

These clarifications to ANSI N45.2.4 - 1972 are required to ensure that QA program continuity is maintained. In actuality these clarifications have been extracted from either standards and guides and are considered more conservative. These clarifications also insure that only one standard or guide is committed to for its applicable circumstance.

1."46 J,

1986 en "U

en C

"Tl

~

JJ

TABLE 17.2.0

§tandard, Requirement or Guide


'-------------------------------------------------Jl m

T_he_C_;;o_m_._p_a_n..._y_'s_P_o_s_it_io_n ____________

c_o_n_f_or_m_a_n_c_e_S_t_a_tu_s ____________

J_u_s_ti_fi_ca_t_io_n _______ ~

Section 4 - Installation: instructions will be implemented by inclusion, as_,petermined by station management, in the appropriate maintenance or modification procedure for safety related items. Standard Company maintenance practices require that care be exercised in the six areas listed whether a procedure is required or not.

Section 5.1 - Inspections: including subsectio-ns 5.1.1, 5.1.2, and the first sentence n 5.1.3, will be implemented as set forth in Section 17.2.1 O of the Operational QA Program.

The Inspection program will incorporate, as determined by station management, those items listed in these subsections. The remaining sentence in 5.1.3 is covered in equivalent detail in the Company's commitmentto ANSI N18.7, section 5.2.6; the requirements as set forth in that commitment will be implemented in addition to the requirements stated here.

Section 5.2 - Tom: including subsections 5.2.1 through 5.2.3, will be implemented as set forth in Sections 17.2.3 and.11 of the Operational QA Program. The test program will consider the elements outlined in this Section, as determined by station management, when developing test, requirements for inclusion in maintenance and modification procedures.

In some cases, testing requirements may.be met by post-installation surveillance testing in lieu of a special post-installation test. Where elements of Section 5.2 are not being met they shall be documented and justified.

I 17.2°47 June, 1986 0

  • Z I\\)

U1 en "tJ en C

".Tl en

)>

Jl

TABLE 17.2.0 Standard, Requirement or Gulde


*----------------------------------Jl m

________ T.:..h;.;..e~C..;:o..:..;m~p;.::a;.;..n;,.r..y..;:*s-.:P-.:o:;.;:s:..:.;il..:..;io;.;..n~-----------C;;.o.:;.;n;.;;.;f.;:;.o.;.;.rm.;.;.a;;.;n..:..;c;.;e'-S;;.t;;.;;;a;.;;.;tu;;..;;s'---------------Ju_s_t'""ifi-"-ca~t;.;.,;ioc...n.;...._ ______ ~

Section 6 - Post Construction Verification: is not generally considered applicable at operating facilities because of the scope of work and the relatively short interval between installation and operation.

Where considered nec~ssary by station management, the elements described in lhis section will be used in the development and implementation of inspection and testing programs: as described in Sections 17.2.3,.10, and.11 of the Operational QA Program.

Section 6.2.1 - Equipment Tests: The last paragraph of this.section deals with tagging and labeling. The Company will comply with an alternate last paragraph which reads:

"Each safety-related item of process instrumentation is identified with a unique number. This number is utilized in instrument maintenance records so that current calibration status, Including data such as the date of the calibration and Identity of the person that performed the calibration, can be readily detE3rmined. Such Information may also be contained on tags or'fabels which may be attached to installed instrumentation".

Section 7 - Data Analysis and Evaluation: will be implemented as stated herein after adding the clarifying

  • phrase "when determined by station management" at the beginning of that paragraph.

1.~8

'-<J...*

1986 0 z I\\)

U1 en

-a en C

"Tl en

)>

J]

TABLE 17.2.0 Standard, Requirement or Guide

~-,----,,---~------.;.__~-.;._..---------,---,-.....,....------,.--,,,~--..,..,..,=-,-.,..,....-------------------:n

-=R=e=g=u=la=to==ry===G=u=id=e=1=.3=3=-*-'-='Q:.:u:.:a:.::.lit:Ly.:..A.::s:.=s.=.ur:.:a::.:n.=.ce::..:..:R:.:e..:!q.=.ui::.:re:.:.m.:.:.e:..:n..:.:t=-s..!.:(0=.1Pc:.:e:.:.r.::.at::.:io:.:.n:.!.)'....:' (!:..R:.:e:..:..v:..:. 2:1*..:2:..:/7:....:8:L)_-.=E::..:n.::.do.:::r:.::s.::.es::..:...:A::.:N:.::S::.I.:..:N:..:..1.:::8*:..:.7_*....:1:.::9:..:.7.::.6*:.._ ____________.::._ __ ~

(I)

T_h_e_C_o_m.....,p_a_n.... y_'s_P_o_s_it_io_n ____________

c_o_n_fo_r_m_a_n_ce_S_ta_t_us ____________

J_u_st_if_1c_at_io_n _______ 0 The Operation~! Quality Assurance Program complies with this guide with the following clarifications and alternatives:

1) paragraph C.3 ("Subjects Requirit1g Independent Review") of Regulatory Guide 1.33 (and Section 4.3.4 of ANSI N18.7 - 1976 which it references) will be implemented as required by the applicable nuclear facility Technical Specifications, Emergency Plan, Security Plan, and Fitness for Duty Program which designate the areas subject to independent reviews.
  • 2) ' Paragraph C.4 ("Audit Program") of Regulatory Guide 1.33 (and Section 4.5 of ANSI N18.7 - 1976 which it references) will be implemented as required by the applicable nuclear facility Technical Specifications, Emergency Plan, Security Plan, Fitness for Duty Program, and administrative controls which designate the minimum areas to be audited. The audit program is further defined and will be implemented as required by the commitment to ANSI N45.2.12 as stated in Table 17.2.0 of the Operational Quality Assurance Program.

. }: :

Paragraph C.4.c of Regulatory Guide 1.33 (and ANSI N18.7.to which It references) will be implemented as clarlfied)n Section 17.2.18 of the Operational Quality Assurance Program Topical Report. Specifically, the frequency for conducting audits of the performance, training, and qualifications of the facility staff may vary based on performance and the safety significance of the audited activity but will not be less frequent than biennial (2 years).

1

3)

Paragraph C.5a of Regulatory Guide 1.33 (and Section 4.4 of ANSI N18.7 which it references) will be.

impleme!'lted with the clarification that the Station Nuclear Safety and Operating Committee may perform this activity.

Clarifications and alternatives meet or exceed applicable guides and standards.

These clarifications are required to ensure that QA program continuity is maintained; i.e., that only-one standard or guide is committed to for a particular topic.

  • 11.2-49 June, 1986 z

I\\)

01 en ;g..

C "

en.

)>

JJ

TABLE 17.2.0 Standard, Requirement or Guide


:D m

....;.T_h...;;;.e_;C:...;o;;.;..m;..;.,p;;..;;acc..n..... Y....::'s-'P-'o:...;s_;it_io-'-n-------------C;;;...o-n.;.;..fo""'r.;.;;m....::a_n;..;;;.ce.;;....;;S;.;.;ta_t..;;;us;;._ __________....::J...;;;u.;;..st-if....::ic..;;;a.;.;.tio""'n~------ ~

4)

Paragraph C.5.d of Regulatory Guide 1.33 (and Section 5.2.7.1 of ANSI N18.7 which it references) will be implemented by adding the clarifying phrase "When determined by station management in front of the fourth sentence of the fifth paragraph. For modifications where these requirements are not considered practicable, a review in accordance with the provisions of 1 OCFR50.59 shall be conducted and documented.

5)

Paragraph C.5.e of Regulatory Guide 1.33 (and Section 5.2.13.4 of ANSI N18.7 which it references) will be implemented subject to the same clarifications made for ANSI N45.2.2 elsewhere in Table 17.2.0 of the Operational QA Program.

6)

Paragraph C.5.f of Regulatory Guide 1.33 (and Section 5.2.19.(2) of ANSI N18.7 which it references) will be implemented when determined by station management.

7) Paragraph C.5.g of Regulatory Guide 1.33 (and Section 5.2.19.1 of ANSI N18.7 which it references) will be implemented with the addition of the modifier "normally" after each of the verbs (should) which the Regulatory Guide converts to "shall.* It is the Company's intent to f1,llly comply with the requirements of this paragraph, and any conditions which do not fully comply will be documented. and approved by station management personnel. In these areas, the reason for the exception shall also be documented. The documentation shall be retained for the same period of time as the affected preoperational test.

1~0

.!{.1986 0 z I\\)

01 co

0) en

~..

C,,

en

)>

0

TABLE 17.2.0 Standard, Requirement or Guide


:0 m

T_h...;..e;;......;;.C..c..o_m"'-p...;;.;ac..;n.._y'..c..s_P-'o-s"""it_io_n ____________

c_o_n_fo_r_m_a_n_c_e_S_t_a_tu_s ____________

J_u_s_ti_fic_a_t_io_n _______ ~

8)

With regard to Section 4.2 of ANSI N18.7 - 1976 titled Program

Description:

Two aspects are addressed in this Section:

a'udits and independent reviews.

The independent review program is implemented as required

,.by the Technical Specifications of the individual nuclear facility. The Company audit program will be described in accordance with and to meet the requirements of ANSI N45.2.12 as endorsed in Table 17.2.0 of the Operational QA Program, the requirements of the individual nuclear facility Technical Specifications, and Sections 17.2.16 and 17.2.1 B of the Operational QA Program.

9)

With regard to Section 4.3 of ANSI N 1 B. 7 - 1976 titled Independent Review Process: The requirements of this Section: Including all of Its subparts, shall be met by compliance with the Technical Specification requirements of the individual nuclear facility.

1 O) With regard to Section 5.2.2 of ANSI 18. 7 - 1976 titled Procedure Adherence: The third and fourth sentences of the first paragraph of the Section address approval requirements for temporary changes to procedures which do not change the intent of the approved proce.dure. Adequate reviews will be provided by two members of th.~ plant supervisory staff knowledgeable in the areas affected, one of which will hold a senior reactor operator license on the unit affected. Adequate reviews will be performed in accordance with Section 17.2.5 above and the Technical Specifications.

17.2-51 June, 1986 0 z.

I\\)

01 rn

"'tJ rn C

'Tl

~

JJ

TABLE 17.2.0 Standard, Requirement or Guide


:0 m

T_h_e_C_o_m_.p_a_n..._y_*s_P_o_s_it_io_n ____________

C_o_n_f_o_rm_a_n_c_e_S_t_a_tu_s ____________

J_u_s_ti_fi_ca_t_io_n _______ ~

11) With regard to Section 5.2. 7 of ANSI N 18.7-1976 titled Maintenance and Modification: Since some emergency situations could arise which might preclude preplanning of all activities, the Company will comply with an alternate

)o the first sentence in the second paragraph which

'reads: "Except in emergency or abnormal operating conditions where immediate actions are required to protect the health and safety of the public, to protect equipment or personnel or to prevent the deterioration of plant conditions to a possibly unsafe or unstable level, maintenance or modification of equipment shall be preplanned and performed in accordance with written procedures.

Where written procedures would be required and are not used, the activities that were accomplished shall be documented after-the-fact and receive the same degree of review as if they had been preplanned. n

12) With rl[IQ!lrd to.Section 5.2.7.1 of ANSI N18.7 - 1976 titled Maintenance Programs: The Company will comply with the requirements of the first sentence of the fifth paragraph, when determined by station management.

This clarification Is needed since it Is not always possible to promptly determine the cause of the malfunction. In all cases, the Company will initiate proceedings to determine the cause, and will make such determinations promptly, when* determined by station management.

13) With regard to Section 5.2.8 of ANSI N18.7 - 1976 titled Surveillance Testing and Inspection Schedule: In lieu of a "master surveillance schedule,* the.following requirement shall be complied with: "A surveillance testing schedule(s) shall be established reflecting the status of all in-plant surveillance tests and Inspections."
14) With regard to Section 5.2.13.1 of ANSI N18.7 - 1976 titled Procurement Document Control: The words "the same degree of control" In the last sentence are replaced with "Engineering review."

17.M2 f.1986 0 z.

I\\)

CTI co

0) en

-u en C

"Tl en

)>

D

\\..*

~

TABLE 17.2.0 Standard, Requirement or Guide

.-~""".,


JJ m

T_h_e_C_o_m.... p_a_n..._y'_s_P_o_s_it_io_n ____________

c_o_n_f_o_rm_a_n_c_e_S_t_a_tu_s ____________

J.;..;u...

s..;.;ti.... fic.;..;a_t_io.;.;n'--------~

15) With regard to Section 5.2.15 of ANSI N18.7 - 1976 titled Review; Approval and Control of Procedures: The third sentence inparagraph three is interpreted to mean:

Applicable procedures, as determined by Station

'.:Management, shall be reviewed following an accident, an

'unexpected transient, significant operator error or equipment malfunction.

The first sentence of the fourth paragraph is considered to be met via procedure reviews as described by administ_rative procedures.

Additional procedure review, approval, and control requirements/exceptions are discussed in Section 17.2.5 above.

tJ

16) With regard to Section 5.2.17 of ANSI N18.7 - 1976 titled Inspections: Not all inspections will require generation of a separate inspection report. Inspection requirements may be.integrated into appropriate procedures or other documents with the procedure or document serving as the record.

However, records of inspections will be identifiable and retrievable.

17) With regard to Section 5.3.9 of ANSI N18.7 - 1976 titled Emergency Procedure: As directed by the NRC, the Company follows a format for emergency procedures which is "symptom" based as opposed to "event" based as stipulated in Section 5.3.9.1. Since the Company has these "symptom" based procedures; "event" based procedures are not normally provided.

i The biennial review requirement is deleted.

The procedures upgrade program provides a systematic and effective process for developing and revising procedures which encompasses the intent of the biennial review.

17.2-53 June, 1986 0 z I\\)

01 en "1J en C

"Tl

~

lJ

TABLE 17.2.0 Standard, Requirement or Guide


:D m

....;T_h....;.e_C'-o'-m..CJpic.ca..;.;.n,;.,,.y....:'s'-'P-o'-s'--it"-'io'-n'--------------C..;:_o..;;..n..;.;.f..;;..or;..;.;m;.;.;a;;;.;.n;..;.c..;;..e..;;S;..;.ta;;;.;t;..;;;u..;;..s __________ ___;J;..;.u;.;;s..;.;.tif;.;.;ic;.;;a;.;.;ti..;:_on'---------~

18) With regard to Section 5.3.9.2 of ANSI N18.7 - 1976 titled Events of Potential Emergency: The Company will interpret item (11) to mean the natural occurrences which have been evaluated in the UFSAR for the individual

_nuclear facility.

19) With regard to Section 5.3.9.3 of ANSI N18.7 - 1976 titled Procedures for Implementing Emergency Plan:

The Company's NRC accepted Emergency Plan for each nuclear facility will be implemented in lieu of the requirements in this Section.

\\

  • 11.2-54 J**1986 -

0 z l\\)

01 en "1J en C

'Tl en

)>

D

TABI...E 17.2.0 Standard, Requirement or Guide


'------------------=-..,.....,....,.......---~,.---,,--~~----~.....------------Jl NRC Regulatory Guide 1.37'- "Quality Assurance Requirements for Cleaning of Fluid Systems and Associated Components of Water-Cooled

~

_N_u_c_le_a_r P_o_w_e_r_P_la_n_t_s'_' (._3_17_3..._)_-_E_n_do_r_se_s_A_N_S_I _N_4_5._2_.1_-_1_9_7_3_. ----------------------------------en

________ T"""'"he~C...;;o....;m....i:p;....a;.;.;n.v'...;;.s_P.....;o;....s....;it_;io_n-'------------C-o.;...n_f..;;,.o_rm....;.a_n....;c __ e_S_t __ a __ tu_s ____________

J_u.....;s..... ti.....;fi..;..ca.;,;.;t;;...io""'n-'-------~

I\\)

The Operationai'Ouality Assurance Program complies with Clarifications meet or exceed applicable The four clarifications listed were generated 01 this guide with the following clarifications:

guides and standards.

to translate general guidance into exact commitments, and to provide alternate,

1) The guide and standard are applicable to those areas of means to perform routine tasks.

the Quality Assurance Program addressing on-site cleaning of materials and components, cleanness control, and preoperation cleaning and layup of fluid systems.

2) With regard to Paragraph C.3 of Regulatory Guide 1.37:

The water quality for final flushing of fluid systems and associated components shall be at least equivalent to the quality of the operating system water except for the oxygen 'and nitrogen content; but this does not infer that chrornates or other additives, normally in the system water, will be added to the flush water.

3) With regard to Paragraph C.4 of Regulatory Guide 1.37:

Expendable materials such as inks and related products, temperature indicating stick, tapes, gummed labels, wrapping materials (other than polyethylene), water soluble darn materials, lubricants, NDE penetrant materials and couplants, desiccants, and like materials which contact stainless steel or nickel alloy surfaces; shall not contain lead; zinc, copper, mercury, cadmium and other low melting point metals, their alloys.or compounds as basic and essential chemical constituents. No more than 0.1

  • percent (1,000 ppm) halogens will be allowed where such elements are leactlable or where they could be released by breakdown of the compounds under expected environmental conditions.

17.2-55 June, 1986

<O CJ) en

'"U fJ)

C i1 en

)>

IJ

L TABLE 17.2.0 Standard, Requirement or Guide


,,-----------------------:0 NRC Regulatory Guide 1.37 * "Quality Assurance Requirements for Cleaning of Fluid Systems and Associated Components of Water-Cooled

. m Nuclear Power Plants" (3/73) - Endorses ANSI N45.2. 1 - 1973.


'--'----'-'-~.:.,.__.c._ _____

_..:.--..c...;.__ __________________________________ U>


'-T"""he;;;__,;:C"-Co::..;.m...J;p:..;;a::..;.n;J..y"-C's::..;.P_o:..;s::..:..it'-'io"""n-'-------------C;;;..o;;;..n..:..;f..;;.o"""rm"""a;;;;;n..:..;c;;..;;e::..;.S;;;..t;.;:;a;.;;.;tu:;..;s;.__ ___________

J~u;;;..;s;..;.t;.;.;ifi..;..ca;;..;.t""'io;..;.n.;__ ______ ~

4) With regard to Section !? of ANSI N45.2.1 - 1973 titled Installation Cleaning: The recommendation that local rusting. on corrosion resistant alloys be removed by

'mechanical methods. is interpreted to mean that local rusting may be removed mechanically, but the use of other removal means is not precluded as determined by Engineering.

\\ :

1~6

.).1986 -

I\\)

(}1 U>

"U..

en C

Tl U>

)>

IJ

)

  • TAB.LE 17.2.0 Standard, Requirement or Guide

'-'--------------------,~~-,--.,..,..,--,--,-=-~--,-=---~~--,~--,,-,---,-~~-.,,.--,--,------JJ NRG Regulatory Guide 1.38 - "Quality Assurance Requirements for Packaging, Shipping, Receiving, Storage, and Handling of Items for Water-Cooled

. m

..;.N.c.:u;:.;;cc:.:le;:.;;a;_r.;....P..;;.o.c.:w..;;.e.;....r.;....P.;.:;la;_nc:.:ts;_"_.(;..:R..;;.e.c.:v.'""'2~,..;;5.;....n;_?....1.)_-..;;E;:.;;n..;;d;.:.o.c.:rs:;..:e;..:;s_A-'N..;..S.:..l:....N..;..4"'""5;:.;;..:::.2;:.;;.2;_-_1;..:9;..;.7-2"--. --------------------------------i T..;..;.;.he;;....::C;..:;o.c.:m..;,;p;.;:a;.;.;n_..y..:;'s-'P-'o:..;s;.;.:itc:.:io:.;..n;.;..* ____________

C.:..o-n-f..;..o;..;.rm;..;.a;;.;.;n_c;..;;e'"'"S""'t;..;.a.:..tu;:.;;s ____________ J-u-s;.;.;tia;..;.fic.:..a-t.;.;io""n'---------~

The Operational Quality Assurance Program complies with this guide with the following clarifications and alternatives:

1)

With regard to Section 2.1 of ANSI N45.2.2 - 1972 titled Planning: (First sentence.) The specific items to be governed by the Standard shall be identified in Administrative Procedures.

2)

With regard to Section 2.3 of ANSI N45.2.2 - 1972 titled

  • *Results:

The specific methods for performing and documenting tests and inspections are given in Sections 17.2.10 and 17.2.11 of the Operational QA Program.

The requirements in these Sections will be implemented in lieu of the general requirements here.

3)

With regard to Section 2.7 of ANSI N45.2.2 - 1972 titled C!arjfjcatjon of Hems: The Company may choose not to explicitly use the four level classification system.

However, the specific requirements of the Standard that are appropriate to each class are applied to the iterns suggested in each classification and to similar items as determined by station management.

4)

With regard to ~action 3.2.1 of ANSI N45.2.2 - 1 ~76 titled Level A Items: As an alternate to the requirements for packaging and containerizing items in storage to control contaminants (Items (4) and (5)), the Company may choose Clarifications and alternatives meet or exceed applicable guides and standards.

  • The clarifications in this section are proposed only to translate general guidance into specific requirements.

The proposed alternatives are provided to reflect current Company practices which are distilled from over ten years of experience gained at operational nuclear facilities.

17.2-57 June, 1986 I\\)

CJ!

en "1J en C

-n c-n

)>

]J

TABl,..E 17.2.0 Standard, Requirement or Guide


::n m

T_h_e__..;;;C_o....;m.c.Lp;...;;.a;....n.,_y_'s_P_o;....s....;it'-io_n ____________

C.;..o.;..;n.... f __

o_rm_a_n....;c...

e_S_t_a_tu_s ____________

Ju_s_ti_fi_ca_t_io_n _______ ~

a storage

  • atmosphere which is free of harmful contaminants in concentrations that could produce damage to -stored items as determined by station management: Similarly (for Item (7)) the Company may obviate the need for caps and plugs, as determined by
~tation management, with an appropriate storage atmosphere, and* may choose to protect weld-end preparations and threads by controlling the manner in which the. items are stored. These clarifications apply whenever items (4), (5) or (7) are subsequently referenced and to Section 3.5.1 titled Caps and Plugs and Section. 3.4 titled Methods of Preservation.
5.

With regard to Section 3.2.3 of ANSI N45.2.2 1972 titled Level C Items:

(Subpart 2) states "Items shall be package.d with a waterproof enclosure...," as an alternative, the company may choose appropriate packaging when the storage environment prevents harmful contaminants in concentrations that could produce-damage to stored items as determined by Station management.

6)

With regard to Section 3.3 of ANSI N45.2.2 - 1972 titled Cleaning:

(Third sentence) the Company interprets "documented cleaning methods" to allow generic cleaning procedures to be written which are implemented,* as necessary, by trained personnel. Each particular cleaning operation shall have an individual cleaning procedure or reference a generic procedure.

The generic procedures will specify methods of cleaning or which type(s) of solvent may be used in a particular application.

1~8 J.1986

~.

I\\)

01 en

-0 en C

""Tl en

)>

n

\\'..::..'-* ___________________ _

TABLE 17.2.0 Standard, Requirement or Guide


'----------------------------------------------Jl m

T_h_e_C_o_m....,p_a_n..._y_'s_P_o_s_il_io_n ____________

c_o_n_fo_r_m_a_n_ce_S_ta_t_us _____________

J.a;;.u,;;.;sta.;.if;;..;;.1c.;;.;.at~io;;.;.n.;....... ______ ~

7) With regard to Section 3.4 of ANSI N45.2.2 - 1972 titled Methods of Preservation: (First sentence) the Company will comply'\\vith these requirements subject to the clarifications of Section 3.2.1, (4) and (5) above, and the

.definition of the phrase "deleterious corrosion" to mean that corrosion which cannot be subsequently removed and which adversely affects form, fit or function.

8) With regard to Section 3.6 of ANSI N45.2.2 -* 1972 titled Barrier and Wrap Material and Desiccants: This section requires the use of nonhalogenated materials in contact with austenitic stainless steel. Refer to Regulatory Guide 1.37 above for the Company position.
9) With reg~rd to Section 3.7.1 of ANSI N45.2.2 - 1972 titled Containers: Cleated, sheathed boxes may be used up to 1,000 lbs. rather than 500 lbs. as specified in 3.7.1(1).

This type of box is safe for, and has been tested for, loads up to 1,000 lbs. Other national standards allow this (see Fe_deral Specification PPP-B-601 ).

Special qualifications testing shall be required for loads above 1,000 lbs.

10) With regard to Section 3.7.2 of ANSI N45.2.2 - 1972 titled Crate:3 and Skids: Skids or runners will normally be used orl'contaln~rs with a gross weight of 1 oo lbs.. or more. Skids or runner will normally be fabricated from 4 x 4 Inch nominal lumber size, minimum, and laid flat except where this is impractical because of the small dimensions of the container. If forklift handling is required, minimum floor clearance for forklift tires will be provided.

17.2-59 June, 1986 0 z I\\)

u, co CJ) rn

'1J rn C

cR

)>

D

TABLE 17.2.0 Standard, Requirement or Guide s_* ------------------*---------------------------------ll m

The Company's Position Conformance Status Justification

__________ _._.__..... ___________ -----_;;.;;~:;..;.;.;.:.=.;.;;;.;;;..==;._----------..;..;;;;.-=-=;.;..;;.;.'--------en

11) With regard to Sections 4.3, 4.4 and 4.5 of ANSI N45.2.2

- 1972 titled, respectively, Precautions During Loading and Transit 'Identification and Marking, and Shipment from Countries Outside the United States: The

Company will comply with the requirements of these Sections
  • subject to the clarifications taken to other Sections which are referenced herein.
12) With regard to Section 5.2.1 of ANSI N45.2.2 - 1972 titled Shipping Damage Inspection:

Warehouse personnel will normally visually scrutinize incoming shipments for damage of the types listed in this Section; this activity is not necessarily performed prior to unloading. Since all required items receive the Item lnspection**of Section 5.2.2, separate documentation of the Shipping Damage Inspection is not necessary.

Release of the transport agent after unloading and signing for receipt of the shipment may be all of the action. taken to document completion of the Shipping Dama*ge Inspection. Any nonconformance noted will be documented and dispositioned as required by Section 17.2.15 of the Operational QA Program.

The person performing the visual scrutiny during unloading is not considered to be performing an inspection func.tion as defined under Regulatory Guide 1.74; therefore, while he will be trained to perform tliis function he may not necessarily be certified (N45.2.6) as an Inspector.

(

~

)

I j

~~

1~0 J.il986 C 0 z I\\)

(JJ

<D m

en

-u en.

C "Tl en

)>

JJ

TABLE 17.2.0 Standard, Requirement or Guide


'----------------'---'-----'-----------------------------:D m

T_h_e_C_o_m_.p_a_n.._y_'s_P_o_s_it_io_n _______. _____

c_o_n_fo_r_m_a_n_c_e_S_t_a_tu_s ____________

J....;u __ s..;...ti,;,;,fic_a.;..;;t~io....;n _______ ~

13) With regard to Section 5.2.2 of ANSI N45.2.2 - 1972 titled Item Inspection:

The second division of ~his subsectiori"requires six additional inspection activities if an item was not inspected or examined at the source.

. Procurement Engineering shall determine and

  • document the extent of receipt inspection based. on consideration of Paragraph 5.2.2.
14) With regard to Section 5.4 of ANSI N45.2.2 - 1972 titled Status Indicating System: The Section states in part "Tags s~all be securely affixed to the items and displayed in an a*rea that is readily accessible." As an alternative, the company may choose to use Labels or Tags to identi~/tems.
15) With rf!bard to Section* 6.1.2 of ANSI N45.2.2 - 1972 titled Levels of Storage:. Subpart (2) is replaced with the following:.

(2)

Level B items shall be stored within a fire resistant, weather-tight, and well ventilated building or equivalent enclosure In which measures have b_een taken against vandalism. This building shall be situated and constructed so that it will not normally be subject to flooding; the floor shall be paved or equal, and well drained. If any outside waters *should come in contact with stored equipment, such equipment will be labeled or tagged nonconforming,. and then the nonconformance document will be processed

  • and* eva1u*ated in accordance with Section
  • 17.2.15. Items shall be placed on pallets, shoring or shelves to permit air circulation. The building shall be provided with uniform heating and temperature control or its equivalent to prevent condensation and corrosion.

Minimum temperature shall be 40°F and maximum temperature shall be 140°F or less if so stipulated by a manufacturer.

17.2-61 _

June, 1986 0 z I\\)

()1 tO m

en

'"tJ en C

Tl en

)>

n

The Company's Position

16) With regard to Section 6.2.1 of ANSI N45.2.2 - 1972 titled Access to Storage Areas: Items which fall within the Level D classification of the standard will be stored in an area which may be posted to limit access, but other positive controls such as fencing or guards will not

-hormall}' be provided.

17) With regard to Section 6.2.4 of ANSI N45.2.2 - 1972 titled Storage of Food and Associated Items: The sentence is replaced with the following: "The use or storage of food, and drinks in any storage area shall be controlled and shall be limited to designated areas where such Lise or storage is not deleterious to stored items where station management deems appropriate.
18) With regard to Section 6.2.5 of ANSI N45.2.2 - 1972 titled Measures to Prevent Entrance of Animals: The sentence is replaced with the following: "Exterminators or other.appropriate measures shall be used to control animals to minimize possible contamination and mechanical damage to storeC, material."

TABLE 17.2.0 Standard, Requirement or Guide Conformance Status l

~ ;

)

I_.'

Justification 1.".62 J

1986 -

a m

en 0 z f\\)

01 co

0) en "U..

en C

"Tl en >

a I

TABLE 17.2.0 Standard, Requirement or Guide


'------------'-------'---------------------------------:0 m

The Company's Position Conformance Status Justification

__________ __. __.._ ______________________________________________ (/)

19) With regard to Section 6.3.4 of ANSI N45.2.2 - titled Identification: The section states "All items and their containers siiall be plainly marked so that they are easily identified without excessive handling or unnecessary opening of crates and boxes."

The company shall

  • substitute "All items (or, if in containers, their containers) shall be plainly marked so that they are easily identified without excessive handling or unnecessary opening of crates and boxes."
20) With regard to Section 6.4.2 of ANSI N45.2.2 - 1972 titled Care of Items: The following alternatives are provided for the indicated subpart:

(5)

"Si:?ace heaters in. electrical equipment shall be

. energized unless a documented engineering

  • evaluation determines that such space heaters are not required."_

(6)

"Large (greater than or equal to 50HP) rotating electrical equipment shall be given insulation resistance tests on a scheduled basis unless a documented engineering evaluation determines that such tests are not required."

(7)

"Within thirty days of having been placed in storage; rotating.equipment weighing over approximately 50 pounds shall be evaluated by engineering personnel to determine if shaft rotation in storage is required: The results of the evaluation shall be documented. If rotation is required, it shall be performed at specific Intervals, be documented, and be conducted so that parts receive a coating of lubrication where applicable and so that the shaft does not come to rest in the same position occupied prior to rotation. For long shafts or heavy equipment subject to undesirabl~ bowing, shaft orientation after rotation shall be specified and obtained.

17.2-63 June, 1986 0 z I\\)

01

<O

0)

(/)

1J

(/)

C,,

(/)

)>

JJ

TABLE 17.2.0 Standard, Requirement or Guide


:0 The Com an 's Position Conformance Status Justification m


'"-------__._..._ _____________________________________ --'------'-------en

21) With regard to Section 6.5 of ANSI N45.2.2 - 1972 titled Removal of Items from Storage: The Company does not consider the last sentence of this Section to be applicable to the operations phase due to the relatively i:;hort period of time between installation and use. The

'tirst sentence of the Section is replaced with:

"the Company.will.develop, issue,. and implement a procedure(s) which cover(s) the removal of items from storage. The procedure(s) will assure that the inspection status of all material issued is known, controlled and appropriately dispositioned."

22) With regard to Section 6.6 of ANSI N45.2.2 - 1972 titled Storage Records: The Company will comply with the requirements of this Section with the clarification that, for record purposes, only the access of personnel not specifically authorized such by station management into indoor storage areas shall be recorded. Unloading or plck-UP.Q! material shall not be considered "access, "nor shall inspection by maintenance and modification Inspection. personnel or audit by Nuclear Oversight personnel; authorized contractors, NRC or other regulatory agents, nor shall tours by non-employees.

1~4 J.1986 -

0 z I\\)

01 en

'1J..

en C

"Tl en

)>

0

TABLE 17.2.0 Standard, Requirement or Guide


*---------------------------------ll m

The Company's Position Conformance Status Justification

_______...;..;..;.;;;._;...;;_""'_i:.;;.;.c..,._...;o_~~--'------------.;..;;..~~~~~~----------.......;;===.;;.;.;.------en

23) With regard to Section 7.3 of ANSI N45.2.2 - 1972 titled Hoisting Equipment: Aerating of hoisting equipment will be considerecl only when absolutely necessary. Prior to performing any lift above the load rating, the equipment

.manufacturer must be contacted for his approval and direction.

The manufacturer must be requested to supply a document granting approval for a limited number of lifts at the new rating and any restrictions involved, such as modifications to be made to the equipment, the number lifts to be made at the new rating, and the test lift load. At all times, the codes governing rerating of hoisting equipment must be observed.

If rerat(ng hoisting equipment is necessary and the Company. cannot or does not contact the equipment manufacturer as described above, the test weight used In temporarily rerating hoisting equipment for special lifts will be at least equal to 110% of the lift weight. A dynamic load test over the full range of the lift using a weight at least equal to the lift weight shall be performed.

24) With regard to Section A3.9 of ANSI N45.2.2 - 1972 titled Marking:

As an alternative to the requirements In Subpart 4, the Company may choose to ma_rk containers with waterproof ink or paint with legible characters.

Additionally, ttie *requirements of Subpart 6 shall only apply to shipment of items. Items In storage shall be affixed with labels or tags with sufficient information to preserve the item's Identity.

17.2-65 June, 1986 0 z I\\)

01 (D

O>

en

"'O en C,,

en

)>

JJ

~.' -

TABLE 17.2.0 Standard, Requirement or Guide

~~-=--~--=--....,....,...-----,,:---~-------~----------...,.....=-----~---------------------:n NRC Regulatory Guide 1.39 - "Housekeeping Requirements for Water-Cooled Power Plants" (Rev. 2, 9ll7) - Endorses ANSI N45.2.3 - 1973.

m

..:::::::::::=:::::::=:===::::::=:==::=:=::::=;=--~::.::::.:::.:..:::..::..!:.:.:...:.:?.~~:.:...:..:.:..:.:..:..::::..:.:::.:......:..:.:::.:::.:....:::.::~:.:::....:.~~.:...::::..::.::::....i:..:=.:::.:..=.~::..:..t.-=::::.=.::::.::::.::..~=-:..:..:.:=::::........:..::..:....:::.: _______ <

en T_he.c-...;;C_o_m..J.p'-a.;...n..,_y_'s_P_o.;...s_it""io:..c.n.;..._ ___________

c;;;;.o;;;.;n.;.;f.;;.o:..;.rm:..;.a:;n.;.;c;.;;e'-S;;;.t;;.;;;a;.;.;tu_s'------------_;;;;.Ju:;s;;.:t;;;.;ifi.;;.c;:;:.at;;;.;io;.;.n"'--------O The Operational Quality Assurance program complies with this guide with the following clarifications:

See Generic Statement which prefaces this table.

1) Additional clarifications for ANSI N45.2.3 - 1973 are indica~ed below for specific Sections.

Section 2.1 Planning: The Company may choose not to utilize the five-level zone designation system, but will utilize standard janitorial and work practices to maintain a level of cleanliness as delineated in the Company's Accident Prevention Manual which is equ_lvalent to the requirements contained in the ref9:~enced section.

Cleanliness will be maintained, consistent with the work-~eing performed, so as to prevent the entry of foreign material into safety-related systems. This _will include, as a minimum, documented cleanliness Inspections which will be performed prior to system closure.

As deti:!rmined by station management, (e.g., the size of the opening would permit entry of the tools being used) control of personnel, tools, equipment, and supplies will be established when the reactor system is_ opened for inspection, maintenance or repair.

Additional housekeeping requirements will be implemented as required for control of radioactive contamination.

Clarifications meet or exceed applicable guides and standards.

These clarifications are proposed to perform a twofold function.

A)

To translate construction criteria to operating plant oriented requirements.

8)

To reflect experience gained at operational nuclear facilities.

It should be noted that where the Company does not specifically Implement requirements as delineated herein, the proposed alternatives are reflected in written procedures and policy and contain all necessary elements to assure quality is maintained.

1.-u6 J.

1986 -

z*

I\\)

01 co

0) en

""D en C,.,

~

n

.* /

TABLE 17.2.0 Standard, Requirement or Guide

. --.\\

..Y


"-----'-------'--------------------------------------Jl m

T_h_e_C_o_m_._p_a_n.._y'_s_P_o_s_it_io_n ____________

c_o_n_fo_r_m_a_n_c_e_S_t_a_tu_s ____________

J_u_s __ ti_fic_a __ t_io_n _______ ~

Section 2.2 - Procedures and Instructions:

Appropriate procedures will be written and implemented.

Section 3.2 - Control of Facjlitjes: The Company may choose not to.utilize the five-level zone designation system, but will utilize the Company's Nuclear Operations Industrial Safety & Health Accident Prevention Manual to maintain a level of cleanliness commensurate with the requirements of this section.

Cleanliness. will be maintained, consistent with the work being performed, so as to prevent the entry of foreign material Into safety-related systems. This will include, as a minimum, documented cleanliness insp~ctions which will be performed prior to system closure. As necessary, (e.g., the size of the opening would* permit entry of the tools being used) control of personnel, tools, equipment, and supplies will be established when major portions of the reactor system are opened for inspection, maintenance or repair.*

Additional housekeeping requirements will be implemented as required for control of radioactive contamination.

Sedion 3.3 - Materials and Equipment: See Generic Statement which prefaces this tabl~.

Section 3.4 - Construction Tools. Supplies and Equipment: See* Generic Statement which prefaces this table.

Section 3.5 - Surveillance.

Inspections aru:t Examination:

Subparagraph (1) See Generic Statement which prefaces this table.

17.2-67 June, 1986 0 z I\\)

01 co m

en

"'tJ en..

C

'Tl

~

Jl

TABLE 17.2.0 Standard, Requirement or Guide


:0 NRG Regulatory Guide 1.58

  • Qualification of Nuclear Power Plant Inspection, Examination and Testing Personnel" (Rev. 1, 9/80) -

m Endorses ANSI N45.2.6 - 1978.

en


0 z


T...;.h"""e __ C;;;...o;;...m.;..;Jp,C.Ca;,;,.;,n"""y--'s--P_o;;...s...,;,.it--io_n_* ___________ c

__ o_n __ f_or_m __ a_n __ c_e_S_ta_t_u_s ___________

J_u_s_tif_ic_a_ti_on _______ l\\l 01 The Operational QA Program complies with this guide with the following clarifications:

1)

With regard to Section 1.2 of ANSI N45.2.6 - 1978 titled Appljcabiljty: The third paragraph requires that the Standard be used in conjunction with ANSI N45.2; the Company no longer specifically commits to ANSI N45.2 in the Operational QA Program. The fourth paragraph requires that the Standard be Imposed on personnel other than Company employees; the applicability of the Standard to suppliers will be documented and applied, as appropriate, in the procurement documents for such suppliers.

2)

With regard to Section 1.4 of ANSI N45.2.6 - 1978 titled Definitions: Definitions in this Reg. Guide 1.58 which are not induded in ANSI N45.2.1 O will be used: all definitions which are included in ANSI N45.2.1 O will be used as clarified in the Company's commitment to Regulatory Guide 1.74.

3)

With regard to Section 2.5 of ANSI N45.2.6 - 1978 titled Physical: The Company will implement the requirements of this Section with the stipulation that, where no special physical characteristics are required, none will be specified.

The converse is also true: If no special physical requirements are stipulated by the Company, none are considered necessary.

/

4)

With regard to Section 3.1 of ANSI N45.2.6 - 1978 titled General: The Company will implement the requirements of this Section with the stipulation that, Level Ill Inspectors are not a specific requirement of the Company's inspection program.

Clarifications meet or exceed applicable guides and standards.

The proposed clarifications reflect Company practices and are provided here to assure that QA program continuity with other delineated standards and guides is maintained.

1 *.. -68 J

11986 _

~

en

'1J en C

"Tl en

)>

0

-,~-'

'..:::____.-/'"

TABLE 17.2.0 Standard, Requirement or Guide

--~--------'------------------------------------------------------JJ NRG Regulatory Guide 1.64 c "Quality Assurance Requirements for the Design of Nuclear Power Plants" (Rev. 2, 6/76) -

~


,---------------------------------------------------0

z.

,-.-~*'t'"""* ___

T"""h.;;..e_;;C'-'o..;..m""p;..;a-n..

Y_;;'s-P_o.;;..s;_it;..;..io....;.n.;.._ ___________

c.;;..o.;;..n""'f.... o __ rm

__ a

__ n_c __ e_S

__ t=a--tu_s _____________ _.;;.Ju-s;;..;;t_ifi"'"ca~t-io;;.;.n;..._ ______ ~

The Operational Quality Assurance Program complies with thisiguide with the following clarification:

See Generic Statement which prefaces this table.

1)

With regard to Paragraph C.2(1) of Regulatory Guide L

1.64: If in an exceptional circumstance the designer's immediate Supervisor is the only technically qualified individual available, this review may be conducted by the Supervisor, providing that: (a) the other provisions of the Regulatory Guide are satisfied, and (b) the justification is individually documented and approved in advan~ci by _ the Supervisor's management, and (c)

Nuclear Oversight audits cover frequency and effectiveness of use of Supervisors as design verifiers to guard against abuse.

Clarification meets or exceeds applicable guides and standards.

Clarification is considered an acceptable alternative to that proposed In the referenced standard in that all quality elements have been maintained.

17.2-69 June, 1986 en

""'CJ en C

""Tl en

)> JJ

\\~-

TABLE 17.2.0 Standard, Requirement or Guide


:0 NRC Regulatory Guide 1.74 - "Quality Assurance Terms and Definitions" (2/74)- Endorses ANSI N45.2.10 -1973.

m

-====::::::=:~==============----=-=:=.:..:..:'.1-:....:.::.=::.:..=.:..:.::..::.....:...::..:..:..:...:.::...::~..::.=.:.:::.:.::..:.:.=-.~....:.!..-=:..:.::.:::..:.::.:::::..:.~~.:...:.::.:=.:.~_:..::..:....;:..:._ _______________ <

T_h_e_C_o_m_..p_a_n_._y_'s_P_o_s_it_io_n _______, _____

c_o_n_f_o_rm_a_n_c_e_S_t_a_tu_s ____________

Ju_s_t_ifi_ca_t_io_n _______ ~

The Operational Quality Assurance Program complies with this guide with the following clarification:

1) _Jhe Company reserves the right to define additional words or phrases which are not included in this Standard:

Such additional definitions will be documented in appropriate procedures and/or in attachments/

appendices to Nuclear Oversight procedures or in I sections of the Operational QA Program.

2) The Company intends for inspections and tests to be performed in accordance with the Operational QA Program by personnel certified as required by that program and for activities defined by "Inspection" and "Testing; in ANSI N45.2.1 O. Appropriate references to the organization which will perform the activity or quality procedures to be used for performing the activity will be made.,.Jf such references are not made, inspections or tests are to be considered under the following definition:

"Inspection" (when used to refer to activities that are not performed by certified personnel) - Examining, viewing closely, scrutinizing, looking over or otherwise checking activities. Personnel performing these functions are not necessarily certified to ANSI N45.2.6. However, station management.through prior procedure review shall determine the appropriate personnel qualifications and reporting relationships.

"Testing" (when used to refer to activities that are not performed by certified personnel) - completion of predetermined procedure steps which determine or verify the capability of an item to meet specified requirements by subjecting the item to a set of physical, chemlca.1, environmental, or operating conditions.

Personnel performing these steps may run necessarily be certified to ANSI N45.2.6. If the completion of the Clarification meets or exceeds applicable

. guides and standards.

The clarifications illuminate actual Company QA program practices and are considered to enhance the Company's commitment to quality practices.

1?:J..70 J.1986.

z I\\)

01

~-*

U>

C

JJ

)>

n

TABLE 17.2.0 Standard, Requirement or Guide


"--------=-'---"-~-'-.;.__-----'------*----------------------------------:D m

T_h_e ___

C_o_m..... p_a_n..._y'_s_P_o_s_it_io_n _______, _____

c_o_n_fo_r_m_a_n_c_e_S_t_a_tu_s ____________

J_u_s_ti __ fic

__ a_t1_*o_n _______ ~

procedural steps utilizes skills and knowledge which they have already obtained from applicable training and experiencer0based programs or formal :education programs. Station management through prior procedure

.,review shall determine the appropriate personnel

  • '.qualifications and reporting relationships.
3) The definition of "procurement documents" will be that provided in ANSI N45.2:13, as augmented by Regulatory Guide 1.74 and the definition provided in 10 CFR 21.3(k). Specifically, the Company will utilize the following compound definition: "Documents that Identify and define the requirements which facilities or basic components must meet in order to be considered acceptable by the purchaser. Procurement document_s may include purchase requisitions, purchase orders (i.e.,

Receiving Reports), drawings, contracts, letters of intent, work orders, proposals and their acceptances, electronic procurement system documents, ~nd specifications or Instructions which are used to define requirements for purchase. Supplier-generated documents and records which were required to be submitted to the Company or to be retained by the supplier are also examples of procurement documents."

4) "Program Deficiencies" (Not defined in ANSI N45.2.10, but used and defined differently In ANSI N45.2.12) -

Failure to develop, document or implement effectively any app_llcable element of the Oper~tional QA Program.

5) "Quality Assurance Program Requirements" (Not defined in ANSI N45.2.10 but U!:ied and defined differently in ANSI N45.2.13) - Those Individual requirements of the Operational QA Program which, when invoked in total or In part,
  • establish the requirements of the quality assurance program for the activity being controlled.

Although not specially used in the Operational QA Program, ANSI N45.2 may be imposed upon the Company's suppliers.

This revised definition of "Procurement Documents" acknowledges the definition provided in 10 CFR 21.3(k). Additionally, the term "contractually binding" is removed to reflect that procurement records retained in accorda.nce with the Company's commitment to ANSI N45.2.9 may not necessarily be the original or a copy of the contractually binding document if the pertinent information is available through one or more of the documents listed In the revised definition.

17.2-71 June, 1986 0 z

~

en

-0 en C,,

~

D

TABLE 17.2.0 Standard, Requirement or Guide


,----------------------------------:u m

The Company's Position Conformance Status Justification

S

'---"'--......_----------*---------------------------------- en

6) With the exception of the lime intervals defined by the station Technical Specifications, the following definitions shall be applied when defining time intervals for other activities:

.;,: Weekly: at least once per 7 days Monthly: at least once per 31 days Quarterly or every 3 months: at least once per 92 days SemiannuaUy or every 6 months: at least once per 184 days Every 9 months: at least once per 276 days Yeady or annually: at least once per 366 days Biennial (2 years): at least once per 732 days Triennial (3 years): at least once per 1098 days The above time intervals may be extended by up to 25%.

1!..aii72 JIP 1986*

0 z*

I\\)

01 en "U

en C

'Tl en

)>

u

~\\

TABLE 17.2.0 Standard, Requirement or Guide

~~=---,--,-=-.,...,---,--~~.,..----,--'-,,,-----~~-----,-~--=----,~-~-~--,,,--~-----,~-...,....,,.....,.,,,,----~---------- :n NRG Regulatory Guide 1.88:: "Collection, Storage and Maintenance of Nuclear Power Plant Quality Assurance Records" (Rev. 2, 10/76 -

m Endorses ANSI N45.2.9 - 1974).

5

.L-_____________________________________________ C/)

T_h_e_C_o_m.... p_a_n..._y_'s_P_o_s_it_io_n ____________

c_o_n_f_or_m_a_n_c_e_S_t_a_tu_s ____________

J_u_s_ti_fic_a_t_io_n _______ ~

The Operational Quality Assurance Program complies with this guide with the following clarifications and alternatives:

1) With regard to Section 3.2.2 of ANSI N45.2.9 - 1974 titled

~: The phrase "an index" is clarified to mean a collection of documents or indices which, when taken together, supply the information attributed to "an index" in the standard.

The specific location of a record "within a storage area" may not be delineated (e.g., The specific location within a computer record file may not be constant. Further, the Company may utilize a computer assisted random access filing system where such location could not be readily "documented", nor would such a location be "relevant").

The storage location will be delineated, but where file locations change within time, the specific location of a record within that file may not always be documented.

2)

With regard to Section 4.2 of ANSI N45.2.9 - 1974 titled Timeliness: The Company's contractual agreement with its contractors and suppliers will constitute fulfillment of the requirements of this Section.

3)

With reg'ard to*section 5.4 of ANSI N45.2.9 - 1974 titled Preservation: The following clarification is substituted for the current subsection 5.4.2: "Records shall be stored in enclosed containers, cabinets or other comparable document storage hardware.*

i Clarifications and alternatives meet or exceed applicable guides and standards.

These proposals are the results of experience gained at operating nuclear facilities for over a decade. As with all guides and standards, additional clarity is sometimes required. Further the alternative (6) presented herein reflects the "as-built" condition of the Company's records storage facilities. These facilities were constructed prior to any regulatory position being defined, and, at the time of construction, were ~onsidered more than adequate to assure permanent records retention. The discrepancies which might exist between current guides and standards and "as-built" conditions are more than compensated for by other more stringent measures such as, a) constant surveillance of the facility both by monitoring devices, security patrols, and fire inspections, and b) Permanently installed dedicated fire suppression apparatus.

17.2-73 June, 1986 I\\)

01 co m

en "U..

en C,,

CJ)

)>

n

TABLE 17.2.0 Standard, Requirement or Guide


*----------------------------------:0 m

The Company's Position Conformance Status Justification

__________ __._..,,_ __________, _______________________ _...;.,~;.;....;;.~c..c.;...------w The following clarification is substituted for the current subsection 5.4.3 "Provisions shall be made for special processed records (such as radiographs, photographs, negatives, microfilm and magnetic media) to prevent damage as appropriate to the record type and will address the manufacturer's recommendations."

4)

With regard to Section 5.5 of ANSI N45.2.9 - 1974 titled Safekeeping: Routine general office and nuclear site security systems and access controls are provided.

5)

With regard to Section 5.6 of ANSI N45.2.9 - 1974 litled Facjljty: Records shall be forwarded to the appropriate records storage facility promptly after completion when required processing and reviews have been completed.

Paragraph' 4, subsection 3 is clarified to require a two-hour minimum fire rating to be consistent with the 1979 version _of the Standard and NBC Crjteria for Record Storage Facilities (Guidance - ANSI N45.2.9, Section 5.6) issued 7/15/79.

Paragraph 4, subsection 9 is clarified to read: "No pipes or penetrations except those providing fire protection,

lighting, temperature/humidity
control, or communications are to be located within the facility and they shall comply *with a minimum two-hour fire protection rating:.

1714 Jt _ 1986

  • 0 z I\\)

CJ1 (0

0) fJ)

"O fJ)

C

'Tl en

)>

0

TABLE 17.2.0 Standard, Requirement or Guide


'---'----------------------------------------------:D m

T_he_C_o_m_..p_a_n.... v_'s_P_o_s_it_io_n ____________

c_o_n_f_o_rm_a_n_c_e_S_t_a_tu_s ____________

J_u_s_ti_fic_a_t_io_n _______ ~

6) The Surry Power Station facility conforms to ANSI N4~.2.9

- 1974 as clarified in this Table except that it is rated at approximately 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />; doors, frames, and hardware are three-hour rated. This facility is considered to meet the

.intent of ANSI* N45.2.9 and provides adequate

  • protection for records.

The North Anna Power Station Records Vault meets the intent of Chapter 3 of NFPA No. 232-1975, subject to the following provisions:

a) The file room is constructed with a minimum fire rating of two (2) hours.

b) Heating, cooling and ventilation for the file room is by means of a forced air system, with all fans, filters, and heating and cooling elements located in an equipment room which is external to the file room.

Ducts for this system are located on the ceiling of the file room and are provided with the standard door dampers with a minimum rating of two (2) hours where they penetrate the file room barrier to other areas of the building.

c) The fi!e room is provided with an early warning fire detection system arid automatic fire suppression system. A *protective signaling system is provided, with a remote alarm located at a constantly attended station.

d) Telephone service is provided to tile file room, with the wire penetration

  • constructed and sealed in accordance with NFPA No. 232-1975.

17.2-75 June, 1986 0 z.

I\\)

01

~

-<O CJ)

U>

"ti U>

C "Tl U>

)> :D

TABLE 17.2.0 Standard, Requirement or Guide


'3:1 m

T.;...h_ec.,....;;.C....;;.o_m_.p;._a_n..,_y....;.'s_P_o;....s_it;....io_n ____________

c.;;..o.;;...n-f_o"""rm"""a-n_c"""e_S_t-a_tu-s;...._ __________ _.;;..Ju~s;;.;;t_ifi'"'"c-at_io-n-'--------~

e) All records stored in the file room are stored in metal cabinets or rolling file shelves, which are arranged to provide adequate access and aisleways. Work not directly related to the storage, retrieval or auditing of records is not allowed in the file room.

Smoking, eating, and drinking is prohibited in the file room.

0 z I\\)

01 (0

0) l f) A wall divides the file room into two sections, with one section used as a file room and the other section used for microfilming of records and/or supply storage. The dividing wall has a minimum fire rating of two (2) hours, Including
  • the fire door dampers in the duct penetrating the wall.

~--

The North Anna Power Station Training Center Vault meets the intent ot_Chapter 3 of NFPA No. 232-1975, subject to the following**provisions:

a) The file room is constructed with a minimum fire rating of two (2) hours.

b) Heating, cooling and ventilation for the file room is by means of a forced air system, with all fans, filters, and heating and cooling elements located in an equipment room which is external to the file room.

Ducts for this system are located above the ceiling of the file room*and are provided with accordion dampers with a minimum rating of two (2) hours where they penetrate the file room barrier to other areas of the building.*

c) The file room is provided with an early warning fire detection system and automatic fire suppression system. A protective signaling system is provided, with a remote alarm located at a constantly attended station.

.~.

'\\

) /.

1~iJll.6 J..

1986

  • en C

"Tl en

)>

'3J

TABLE 17.2.0 Standard, Requirement or Guide


'----'---------~----'----------------------------------ll m

T_h_e_C_o_m...... p_a_n.,._y_'s_P_o_s_it_io_n ____________

c_o_n __ f_o_rm

__ a_n_c_e_S_t_a_tu __ s ____________

J;;..;u"""s;...;.;ti""'fic.;;.;a.;;.;t.;..:;io..;.,;n'--------~

d) Telephone service is provided to the file room, with the wire., penetration constructed and sealed in accordante with NFPA No. 232-1975.

e) All records stored in the file room are stored in metal cabinets, which are arranged to provide adequate access and aisleways. Work not directly related to the storage, retrieval or auditing of records is not allowed in the file room. Smoking, eating, and drinking is prohibited in the file room.

The Innsbrook Technical Center's Vital Records Vault for nuclear records conforms to the requirements of Section 5.6 of ANSI N45.2.9 - 1974 without exceptions.

The Surry Training Center training records vault (Main Building) conforms to the requirements of section 5.6 ANSI N45.2.9 - 1974 without exceptions.

The Surry Training Center training records vault (Simulator Building) conforms to the requirements of section 5.6 ANSI N45.2.9 - 1~74 with the following exceptions:

a) The door is a UL-rated three-hour fire door.

b) The records storage vault is constructed with a minimum fire rating of two (2) hours.

17.2-77 June, 1986 0

2 I\\)

01 en "lJ en C

"Tl

~

lJ

TABLE 17.2.0 Standard, Requirement or Guide

..,.....,,---=--,------,----~-------,--~-----,---,-......,,.--,-.,.----,--...,..,,,,---.---,~-~~~---,----,-~--..,...,,,..,...----,-----JJ NRC Regulatory Guide 1.94 - "Quality Assurance Requirements for Installation, Inspection, and Testing of Structural Concrete and Structural Steel

~

During the Construction Phase of Nuclear Power Plants" (Rev. 1, 4/76) - Endorses ANSI N45.2.5 - 1974.

00


0 z*


"'-T.;..;.he"'-"C;....;;o;.;.;m'""p;;..;;a"'"nJ..y....;;'s..... P_o;;..;s;...;.il""io;..;..n~-----------C.;;..o.;..;n;..;.;f.;;.o.;..;.rm.;..;.a~n"'"'c_e'-S-t=a--tu-s'--___________ J

__ u

__ s __ ti_fi __

ca_t __ io_n_------- ~

The Operational Quality Assurance Program complies with this guide with the following clarification:

See Generic Statement which prefaces this table.

1) With regard to Section 2.5.1 of ANSI N45.2.5 - 1974 tilled Selection: The Company complies with the requirement set forth in the first paragraph of this Section for selection of measuring and test equipment on the basis of sufficient accuracy to determine conformance to the standard's requirements: This is accomplished without the use of calibrated balances or volumetric buckets.

Clarification meets or exceeds applicable guides and standards.

The proposed clarification is used to translate construction oriented documents to operational regulations.

1!J,flB J.1986

  • Cl)

"'l]

Cl)

C ii

~

JJ

-~

TABl,.E 17.2.0 Standard, Requirement or Guide

\\.!


'-*'-*-------------------.,.......--.......,.~~-,--,.............,.--------------lJ NRG Regulatory Guide 1.116 - "Quality Assurance Requirements for Installation, Inspection and Testing of Mechanical Equipment and Systems" m

(Rev. 0-R, 6/76) - Endorses ANSI N45.2.8 - 1975.

~


0 z

T_h_e_C_o_m_..p_a_n..._y_'s_P_o_s_it_io_n ____________

c_on_f_o_rm_a_n_c_e_S_t_a_tu_s ____________

Ju_s_t_ifi_ca_t_io_n _______ l\\)

01

  • The Operational Quality Assurance Program complies with this guide with the following clarification:

See Generic Statement which pref aces this table.

Clarification meets or exceeds applicable guides and standards.

This clarification is proposed as a construction to operations device.

17.2-79 June, 1986 en

~..

C "Tl en

)>

D

TABLE 17.2.0 Standard, Requirement or Guide

~...,,.....~--,.--~-----------------,-----,-~--'-----,---...,...,~-.--------...---.----------------JJ NRG Regulatory Guide 1. 123 - "Quality Assurance Requirements for Control of Procurement of Items and Services for Nuclear Power Plants" m

.... (R_e_v_. _1 __

, 7_17_7.... )_-_E_n_d_or_s_es_A_N_S_I N_4_5_.2_. 1_3_-_1_9_7_6_. -------------------------------------- en 0

T_h_e_C_o_m_.p,__a_n_,,.y_'s_P_o_s_it_io_n~ ____________

C.;;..o....;n"""f.;...or-m_a"""n_c __

e....;S __ ta_t __ u_s __________

---"J;..;;u;.;.s...

tif""'"'ic;.;;;a""'ti--on _________ z The Operational-Quality Assurance Program complies with this guide with the following clarifications:

1) With regard to Section 1.3 of ANSI N45.2.13 - 1976 titled Defjnitions:

With-two exceptions (Procurement Document and Quality Assurance Program Requirements) definitions in this Standard which are not included in ANSI N45.2.1 O will be used; all definitions which are included in ANSI N45.2.1 O will be used as clarified in the Company's commitment to Regulatory Guide 1.74. The two exceptions are defined in Table 17.2.0 under Regulatory Guide 1.74.

2)

With regard to Section 1.2.2 of ANSI N45.2.13 - 1976 titled Purchaser's Responsibilities: Item c is modified as follows: "Evaluation of the supplier's QA program shall be concjycted as determined by Nuclear Oversight based I on the complexity and use of the procurement."

3) With regard to Section 3.1 of ANSI N45.2.13 - 1976 titled Procurement Document Preparation. Review and Change Control: The phrase "the same degree of control" Is stipulated to mean "equivalent level of review and approval." The changed document may not always be rerevlewed "by the originator; however, at least an equivalent level supervisor shall review *and approve any changes.
4)

With regard to Section 3.4 of ANSI N45.2.13 - 1976 titled Procurement Document i Control: The Company will meet the requirements of Sections 17.2.4 and 17.2.7 of the Operational QA Program In lieu of the requirements specified in this Section.

Clarifications meet or exceed applicable guides and standards.

Clarifications contained herein reflect actual Company QA Program practices. Further, these proposals assure continuity with the QA Program and other regulations or guides, and are considered to enhance the aforementioned program.

1~-80 Jt.1986

  • I\\)

01 en 1J en C,,

en

)>

D

TABLE 17.2.0 Standard, Requirement or Guide

0

~-----'-*---------------------------------~m I T_h_e_C_o_m...... p_a_n.L.y'_s_P_o_s_it_io_n ____________

c_o_n_fo_r_m_a_n_c_e_S_t_a_tu_s ____________

J_u_s_tif_ic_a_ti_o_n _______ en

5) With regard to Section 5.3 of ANSI N45.2.. 13 - 1976 titled Preaward Evaluation: The Company will comply with an alterna~e paragraph which reads: "Except in unusual circumstances as determined and documented
  • by

~talion management (e.g., replacement parts are

  • needed to preclude tf)e development of some unsafe or undesirable condition at a nuclear facility), and except in those cases where dedication techniques that do not rely on the supplier's QA program are necessary (e.g. the sole use of special tests and inspections to verify the quality of certain commercial grade items where the supplier has no formal QA program), a preaward evaluation of the Supplier shall be performed as required by the Operational QA Program."
6)

With re~ard to Section 6.4 of ANSI N45.2.13 - 1976 titled Control of Changes in Items of Service: The phrase "the Operational QA Program" will be inserted in lieu of "ANSI N45.2, Section 7."

7) With regard to Section 8.2 of ANSI N45.2.13 - 1976, titled Disposition: The third sentence of item b is revised to read:

Nonconformances to the contractual procurement requirements or Purchaser approved documents and which consist.of one or more of the following shall be submitted to the Purchaser for approval of the r~commended disposition prior to shipment when the nonconformance could adversely affect the end use of a module or shippable component relative to safety, interchangeability, operability, reliability, integrity, or maintainability:

1) Technical or material requirement is violated; 17.2-81 June, 1986 0 z.

I\\)

01 en "tJ en C,,

~

D

TABLE 17.2.0 Standard, Requirement or Guide


:0 m

T_h_e_C_o_m_._p_a_n....

v'_s_P_o_s_it_io_n ____________

c_o;;...n_f..;;..or'-m

..... a

__ n_c--e_S_t __ a_tu __ s ____________ J.;;...u""s....;.ti'""fi..;..ca;.;.;t;;....;io_n'--------~

2)

Requirement in Supplier documents, which have been approved by the Purchaser, is violated:

3)

Nonconformance cannot be corrected by continuation of the original manufacturing process or by rework; and/or

4) The item does not conform to the original requirement even though the item can be restored to a condition such that the capability of the item to function is unimpaired.
  • A module is an assembled device, instrument, or piece of equipment identified by serial number or other identification code, having been evaluated by inspection and/or test for conformance to procurement requirements regarding end use. A shippable component is a part of a subassembly of a device, instrument, or a piece of equipment which is shipped as an individual item and which has been evaluated by inspection and/or test for conformance to procurement requirements regarding end use.

0 z I\\)

01 en

"'ti..

en C

~

D

TABLE 17.2.0 Standard, Requirement or Guide I

I I

I I

I I

I I

I I

I

D :

..,....,..,,....,,,....=----=-----------.,..--,--------=---__,..__,.--_.,,,.---,=--,.,....,.----,,---,--,~---~---------------m NRC Regulatory Guide 1.144 - "Auditing of Quality Assurance Programs for Nuclear Power Plants" (Rev. 1, 9/80) - Endorses ANSI N45.2.12 - 1977.

-=====:::::::;:;~==============-__:_:==;;;.:..:?...:..:.-=:..:::.::.:.:.:.L..:..:.::.::.==::.:.:..:::...:..::.::..2.:.:::.:.:=-:.::.:.....:..:.;::::=.::::...:....::.:.:.::.:.....:~.:.:::.....l:.::.::.:.:~.:::..::.::!...-=:.:.::.::.:.::.::.::..:..~~~::::..:.-==-~:..:....:.-----en T_h __ e_C_o_m-'p._a_n_..y_'s_P_o_s_il'-io_n ____________

C~o.;;..;n..;.;.f.;;..or-m_a""'n_c..a.e.... S

..... ta_t __

u;.;;.s __________

_..;;J;_;;u;.;;.st.;;;if"-,;ic;.;:;a:.;.;.tio;:.;n.;__ ______

. ~

I\\)

The Operationa(Quality Assurance Program complies with Clarifications meet or exceed applicable These clarifications have been proposed to 01 this guide with the following clarifications:

guides and standards.

maintain program continuity with other referenced standards and guides committed

1) With regard to Section 1.4 of ANSI N45.2.12 - 1977 titled to in Table 17.2.0.

Definitions: With one exception (Program Deficiencies) the definitions in this Standard which are not included in ANSI N45.2.1 O will be used as clarified in the Company's commitment to Regulatory Guide 1.74.

The one excepted definition and clarified definition relevant to this standard are defined In Table 17.2.0 under ReQulatory Guide 1. 7 4.

2)

With regard to Section 2.2 of ANSI N45.2.12 - 1977 titled Personnel Qualifications: The qualification of Company audit personnel will be accomplished as described to meet the requirements of ANSI N45.2.23 - 1978 as endorsed in Table 17.2.0 and Sections 17.2.2 and 17.2.18 of the Operational QA Program.

3)

With regard to Section 2.3 (and subsections 2.3.1 through 2.3.3) of ANSI N45.2.12 - 1977 titled Trajnln*g:

The training of Company audit personnel will be accomplished as described to meet the requirements of ANSI N45.2.23 - 1978 as endorsed In Table 17.2.0 and Sections. 17.2:*2 *and 17.2.18 of the Operational QA Program.

Further, where alternatives have been proposed they reflect Company QA Program practices and are considered to enhance the referenced program.

Not alJ standards, guides and regulations can be considered programmatlcally error-free, therefore, operational experience utilizing these documents and the proposed alternatives must be taken Into consideration.

  • 17.2-83 June, 1986

(/)

-u

(/)

C i1

~

D

TABLE 17.2.0 Standard, Requirement or Guide JJ


""----------------------------------------------------m The Company's Position Conformance Status Justification en

__________ _._.__... ____________________________________________ a

4) With regard to Section 2.4 of ANSI N45.2.12 - 1977 titled Maintenance of Prof icjency:

The maint,anance of proficiency of the Company audit personnel will be accomplished as described to meet the requirement of

-ANSI N45.2.23 - 1978 as endorsed in Table 17.2.0 and Sections 17.2.2 and 17.2.18 of the Operational QA Program.

5)

With regard fo Section 3.3 of ANSI N45.2.12 - 1977 titled Essential Elements of the Audit System: The Company will comply with subsection 3.6.5 as it was originally written (subsection 3.2.5) In ANSI N45.2.12, Draft 3, Revision 4:

"Provisions for reporting on the effectiveness of the Quality Assurance Program to the responsible management." For the auditing organization (The Company), effectiveness is reported as required by the Individual nuclear facility Technical Specifications.

Other t~_n _ audit reports, the Company may not directly report on the effectiveness of the quality assurance programs to the audited organization when such organizations are outside of the Company.

Subsection 3.3.6 requirements are considered to be fulfilled by compliance with the organization and reporting measures outlined in the Operational QA Program and_

  • the Technical Specifications of the Individual nuclear facility.

Subsection 3.3.7 requires verification of effective corrective actio_n on a "timely basis."

17:-111 J~ 1986.

z*

I\\)

(11 en "O

en C

Tl

~

JJ

The Company's Position Timely basis is interpreted to mean within the framework or period of time for completion of corrective action that is accepted by Nuclear Oversight. Each finding requires a response and a corrective action completion date; these tlates are subject to revision (with the approval of Nuclear Oversight) and must be escalated to higher authority when there is disagreement between the audited and the auditing organization on what constitutes "timely corrective action."

6)

With regard to Section 3.5 of ANSI N45.2. 12 - 1977 titled Scheduling: Subsection 3.5.3.1 is interpreted to mean that the Company may procedurally review qualification of a contractor's or supplier's quality assurance program prior to awarding a contract or purchase order by means other than audit.

7) With regard to Section 4.3.1 of ANSI N45.2.12 - 1977 titled Pre-Audit Conference: The Company will comply with requirements of this Section by inserting the word "Normally" at the beginning of the first sentence. This clarification is required because in the case of certain unannou,:iced audits or audits of a particular operation or work activity, a pre-audit conference might interfere with the spontaneity of the operation or activity being audited.* In other cases, persons who should be present at a pre-audit conference may not always be available.

Such lack of availability should not be an impediment to beginning an audit. Even in the above examples, which are not intended to be all inclusive, the material set forth in Section 4.3.1 will normally be covered during the course of the audit.

TABLE 17.2.0 Standard, Requirement or Guide Conformance Status Justification

,,_/

17.2-85 June, 1986

0 m
5 en 0 z I\\)

01

..I.

cc m

en "lJ en C

"Tl en

)>

0 I

I I I' I

' I I

I I

\\\\

Ii I\\

I

TABLE 17.2.0 Standard, Requirement or Guide

0 m

The Company's Position

8) With regard to Section 4.3.2 of ANSI N45.2.12 - 1977 titled Audit Process:

a) Subsection 4.3.2.2 could be interpreted to limit auditors to the review of only objective evidence; sometimes and for some program elements, no objective evidence may be available or subjective evidence may be more appropriate. The Company will comply with an alternate sentence which reads:

"When ~vailable, objective evidence shall be examined for compliance with Quality Assurance Program requirements. When subjective evidence is used (e.g., personnel interviews, direct observations by the auditor), then the audit report must indicate how the evidence was obtained."

b) Subsection 4.3.2.4 is modified as follows to take into account the fact that some nonconf ormances are virtually "obvious" with respect to the needed corrective action:

"When a nonconformance or quality assurance program deficiency is identified as a result of an audit, unless the apparent cause, extent and corrective action are readily evident, further investigation* shall be conducted by the audited organization in an effort to Identify the cause arid effect and to determine the extent of the corrective action required."

Conformance Status Justification 17.2-86 J.1986 Cf) 0 z I\\)

01 Cf)

"1J..

Cf)

C,.,

en.

}>

0

,:_./

TABLE 17.2.0 Standard, Requirement or Guide

IJ I m\\

The Company's Position Conformance Status Justification rn 11 1


~_....;..c.;.......__ _____________________________________________ 0 1,

c) Subsection 4.3.2.5 contains a recommendation which is clarifieg with the definition of "acknowledged by a member of the audited organization" to mean that a "member of the audited organization has been informed

  • of the findings."

Agreement. or disagreement with a finding may be expressed in the response from the audited organization.

9) With regard to Section 4.3.3 of ANSI 45.2.12 - 1977 titled Post-Audit Conference: The Company will substitute and comply with the following paragraph: "For all external audits, a post-audit conference shall be held with management of the audited organization to present audit findings and clarify misunderstandings; where no adverse-findings exist, this conference may be waived by management of the audited organization: such waiver shall be documented in the audit report.

Unless unusual operating or maintenance conditions preclude attendance by appropriate managers/supervisors, a post-audit conference shall be held with managers/supervisors for all internal audits for the same reasons as above. Again, if there are no adverse findings, management of the internal audited organization may waive the post-audit conference: such waiver shall be documented in the audit report."

17.2-87 June, 1986 Z

II I

N 01 rn

'"tJ en C

"Tl en

)>

0

TABLE 17.2.0 Standard, Requirement or Guide JJ


m The Company's Posi!ion 1 O) With regard to Section 4.4 of ANSI N45.2.12 - 1977 titled Reporting:.

  • a) This Section requires that the audit report shall be signed by the audit team leader; this is not always the most expeditious route to take to assure that the audit report is issued as soon as practical.

The Com~any will comply with Section 4.4 as clarified in the following opening statement: "An audit report, which shall be signed by the audit team leader, the I Staff Quality Specialist (Audit Coordinator) or his supervisor in his absence, shall provide": In cases where the audit report is not signed by the Audit Tea'!I Leader due to his absence, one record copy of the report must be signed by the Audit Team Leader upon his return. The report shall not require the. Audit Team Leader's review, concurrence, or signature if the Audit Team Leader is no longer employed by the auditing organization at the time the audit report Is issued.

b) The Company will comply with subsection 4.4.3 clarified to read: "Supervisory level personnel with whom significant discussions were held during the course of pre-audit (where conducted), audit, and post-audit (where conducted) activities.

c) Subsection 4.4.6 requires audit reports lo include recommendations for corrective actions; the Company : may choose not to comply with this requirement.

Instead, Audit Team Leaders are required to document all adverse findings on audit finding forms.

Conformance Status Justification 17:a~a Ju., 1986.

en 0 z.

I\\)

01 co m

en..

\\)

en C

'Tl

~

JJ

TABLE 17.2.0 Standard, Requirement or Guide

.-.~

I JJ


m The Company's Position Conformance Status Justification en


"---'~-L---------------------------------------~==-=-~-----~o, z

1 1

The procedure for processing audit findings allows l\\l 1

the Audit.Team Leader to document actions which 01 are considered necessary to correct the finding; the 1

Audit Team Leader may also document actions

~

which are considered unacceptable for correcting m

the finding:

the audit finding with these "Recommendations" is then transmitted to the audited organization. In addition; the Audit Team Leader is required to review the response to the audit finding and determine if it Is acceptable. Any disagreements must be escalated to higher management for resolution.

11) With regard to Section 4.5.1 of ANSI N45.2.12 - 1977 titled By Audited Organization: The Company will comply with the following clarification of. this Section:

"Management of the audited organization or activity shall review and Investigate all adverse findings, as necessary, (e.g., where the cause is not already known, another organization has not already Investigated and found the cause, etc.) to determine and schedule appropriate corrective action including action to prevent recurrence.

They shall respond, in writing, within thirty days after the date of Issuance of the audit report.

The response shall clearly state the corrective action taken or planned to prevent recurrence and the results of the Investigation if conducted.

In the event that corrective action is not completed by the time the response Is submitted, the audited organization's response shall include a ~cheduled date for completion of planned corrective action.

The audited organization shall take the appropriate action to assure that corrective action is accomplished as scheduled.

'17.2-89 June, 1986 en "lJ en C,,

~

JJ

TABLE 17.2.0 Standard, Requirement or Guide*

--,---=---------------------------------,---,---=---,,,.,---.,,.-----,------------JJ NRC Regulatory Guide 1.146 - "Qualification of Quality Assurance! Program Audit Personnel for Nuclear Power Plants" (Rev. 0, 8/80) -

m Endorses ANSI N45.2.23 - 1978.


en T_h_e_C_o_m~p~a_n_y_'s_P_o_s_it_io_n ______. _____

c_o_n_fo_rm_a_nc_e_S_ta_tu_s ____________

J_us_t_ifi_c_at_io_n _______ ~*

The Operational Quality Assurance Program complies with this guide with the following clarifications and alternatives:.

1) With respect to Section 1.4 of ANSI N45.2.23 - 1978 titled Definitions: Definitions in this Standard which are not included in ANSI N45.2.10 will be used; "AUDIT" which is included in ANSI N45.2.1 O will be used as addressed in the Company's commitment to Regulatory Guide 1.74.
2)

With respect to Section 2.2 of ANSI N45.2.23 - 1978 titled Qualification of Auditors:

Subsection 2.2.1 references ANSI N45.2 therefore, the Company will comply with an alternate subsection 2.2.1 which reads:

Orientation to provide a working knowledge and understanding of the Operational QA Program, including the ANSI standards and Regulatory Guides Included in Table 17.2.0 of the Program, and the Company's procedures for implementing audits and reporting results.

3)

With respect to Section 2.3 of ANSI N45.2.23-1978 titled auaUf!caUon of Lead Auditors:

Suhsection 2.3.3.1 references ANSI N45.2; therefore, the Company will comply with an alternate subsection 2.3.3.1 that reads:*

Knowledge and understanding of the Operational QA Program, including the ANSI Standards and Regulatory Guides included in Table 17.2.0 of the Program, particularly ANSI N45.2.12 and other nuclear-related codes and regulations, as applicable.

4)

With respect to Section 3.2 of ANSI N45.2.23 - 1978 titled Maintenance of Proficiency: The Company will comply with the requirements of this Section by defining "annual assessment" as one which takes place every 12 months or less and which uses the initial date of Clarifications and alternatives meet or exceed applicable guides and standards.

The clarifications and alternatives reflect experience gained at operational nuclear facilities and are intended to enhance and provide additional guidance in the areas of auditing as delineated herein.

I\\)

01 en

-0 en C

Tl

~

JJ

L

-~

TABLE 17.2.0 Standard, Requirement or Guide


'-~..;;..;;.."'-=;;::.;..;.ic...;;_~~;.;..;...----------_...;;;.=.;;;.;.;...;.;;;..;.;...........;.;;~;._..---------~===;.;..;...------'\\,~

The Company's Position Conformance Status Justification

.~

certification (not the calendar year) as the starting date for determining when such annual assessment is due.

5) With respe~~ t~ Section 4.1 of ANSI N45.2.23 - 1978 titled Organizational Responsibility: The Company will comply with this Section with the substitution of the following sentence in place of the last sentence in the Section.

The Manager - Nuclear Oversight, Director - Nuclear Oversight, Supervisor-Quality (Vsndor Programs),

Staff Quality Specialist (Audit Coordinator), or Audit Team Leader shall, prior to commencing the audit, assign_ personnel who collectively have experience or training commensurate with the scope, complexity, or special nature of activities to be audited.

6) With respect to Section 5.3 of ANSI N45.2.23 - 1978 titled Updating of Lead Auditor's Records: The Company will substitute the following sentence for this Section:

Records for each Lead Auditor shall be maintained and updated during the period of the annual management assessment as defined in Section 3.2 (as clarified).

17.2-91 June, 1986 0 z

" ro

-~ I

..a CC)

(T.)

I

\\

\\

' \\

I

\\,

en :

en :

cl "Tl en

)>

';cJ

REVISION 25

.i Appendix B Topical 10 CFR 50 Report Criterion Section Title Abstract 17.2.1 Organization Defines the relationship of departments to the quality**

assurance effort associated with the operation of the nuclear power station.

II 17.2.2 Quality Assurance Defines the Operational Program Quality Assurance Program, its overall responsibility and provisions.

Ill 17.2.3 Design Control

  • Defines the policy, responsi-bility and procedures for exercising design control.

IV 17.2.4 Procurement Establishes policy applic-Document Control able to plant operation and maintenance.

V 17.2.5 Instructions, Establishes guidelines for

-1/

Procedures and preparing instructions, Drawings procedures and drawings.

VI 17.2.6 Document Control Establishes policy for the control of procedures and instructions.

VII 17.2.7 Control of Purchased Establishes methods for Material, Equipment assuring that purchased and Services items conform to the speci-fied quality requirements.

VIII 17.2.8 Identification and Establishes procedures for Control of Material, the identification and Parts and Components control of material, parts and components.

IX 17.2.9 Control of Special Establishes procedures Processes whicb assure that special processes are controlled and accomplished by qualified personnel.

17.2-92

__ _,,_ __ =-- -~~-

SPS UFSAR Appendix 8 Topical 10 CFR 50 Report Criterion Section Title Abstract X

17.2.10 Inspection Establishes a program for inspection of activities affecting quality.

XI 17.2.11 Test Control Establishes policy for power stations test programs.

XII 17.2.12 Control of Measuring Establishes policy for con-and Test Equipment trot and calibration of test and measuring equipment.

XIII 17.2.13 Handling, Storage Establishes policy for this and Shipping function as related to material and equipment.

XIV 17.2.14 Inspection, Test, Makes reference to appro-and Operating Status priate administrative procedures which govern this function.

~

xv 17.2.15 Non-Conforming Establishes policy for Material, Parts, or reporting and controlling Components non-conforming materials, parts, or components.

XVI 17.2.16 Corrective Action Establishes policy for identifying, documenting, notifying, determining causes and preventing defects from recurring.

XVII 17.2.17 Quality Assurance Assures maintenance, identi-Records fication and retrievability of records.

XVIII 17.2.18 Audits Defines policy and procedures for audit programs.

17.2-93