Docket Nos. 50-280, 50-281
SEP O 9 1987
Virginia Electric and Power Company
I/ATTN:
Mr. W. L. Stewart, Vice President,
Nuclear Operations
P. 0. Box 26666
Richmond, VA
23261
Gentlemen:
SUBJECT:
-
(NRC INSPECTION REPORT NOS. 50-280/87-22 AND 50-281/87-22)
This refers to the Nuclear Regulatory Corrmission (NRC) inspection conducted by
Dr. W. B. Gloersen on August 3-7, 1987.
The inspection included a review of
activities authorized for your Surry facility. * At the conclusion of the
inspection, the findings were discussed with those members of your staff
identified in the enclosed inspection report.
Areas examined during the inspection are identified in the report.
Within
these areas, the inspection consisted of selective examinations of procedures
and representative records, interviews with personnel, and observation of
activities in progress.
The inspector also conducted independent
measurements, in the Region II Mobile Laboratory at your site to verify your
capability for analyzing radioactive effluents and to establish and maintain
standardized methodology among regulated facilities and the NRC.
The inspection findings indicate that certain activities appeared to violate
NRC requirements.
The violations, references to pertinent requirements, and
elements to be included in your response are described in the enclosed Notice
of Violation.
Your attention is invited to the unresolved item identified in the inspection
report. This matter will be pursued during fut~re inspections.
In accordance with Section 2.790 of the NRC
1s
11Rules of Practice,
11 Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and its enclosures
will be placed in the NRC Public Document Room.
The responses directed by this letter and its enclosures are not subject to the
clearance procedures of the Office of Management and Budget as required by the
Paperwork Reduction Act of 1980, PL 96-511.
8709150027 80750090009280
ADOCK
G
PDR.
e
Virginia Electric and Power Company
2
Should you have any ques.tions concerning this letter, please contact us.
Enclosures:
1.
2.
Inspection Report
cc w/encls:
t.R'. F. Saunders, Station Manager
i~. E. Clark, Manager - Nuclear
Programs and Licensing
bee w/encls:
LJl'RC Resident Inspector
Document Control Desk
Commonwealth of Virginia
RI7,/p;f.
WBloersen
8/)t/87
RI]
JitnJJ
JK!t/Te
8/ftt /87
~I~
~17;\\s
818 /87
Sincerely,
J. Philip Stohr, Director
Division of Radiati.on Safety
and Safeguards
Rlh r/
FC~t~ell