J

..'\\-

January 16, 1985 e Docket Nos. 50-280 and 50-281 Mr. W. L. Stewart Vice President - Nuclear Operations Virginia Electric and Power Company Post Office Box 26666 Richmond, Virginia 23261

Dear Mr. Stewart:

Distribution Docket file NRC PDR LPDR Gray file CParrish KJohnston EJordan JPartlow ACRS (10)

DEisenhut ORB#l ROG DNeighbors JDonohew PMcKee OELD By letter dated January 17, 1977, the staff requested that you evaluate the previously unevaluated potential consequences of a postulated Fuel Handling Accident Inside Containment (FHAIC) at Surry Power Station, Units 1 and 2 (Surry 1/2). Enclosed is our safety evaluation of the fuel handling accident inside containment for Surry 1/2.

Our evaluation is based on our review of your letters dated July 5, 1977; August 5, 1977; March 7, 1978; and our approval dated April 9, 1984, of your request to increase burnup to 45,000 MWd/MTU.

We conclude that the potential consequences of an accident involving the handling of spent fuel inside containment are within the exposure guidelines of 10 CFR Part 100 and that no additional restrictions of fuel handling operations and plant operating procedures are needed.

As explained in the enclosure, our conclusion is contingent upon the installment of acceptable prefilters (i.e., ones that meet Regulatory Guide 1.52, Revision 2, Position C.3c) for the Auxiliary Building Ventilation System.

Please provide a response within 30 days of receipt of this letter committing to provide acceptable prefilters.

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Sincerely,

/s/SAVarga Steven A. Varga, Chief Operating Reactors Branch #1 Division of Licensing

  • SEE PREVIOUS WHITE FOR CONCURRENCE ORB#l:DL*

KJohnston/ts 01/ 10/85 ORB#5:DL*

JDonohew 01/ 14'85

~L

  • ~~~ors OI7ts,'85

Docket Nos. 50-280 and 50-281 Mr. W. L. Stewart e

Vice President - Nuclear Operations Virginia Electric and Power Company Post Office Box 26666 Richmond, Virginia 23261

Dear Mr. Stewart:

Distribution Docket file NRC PDR LPDR ORB#l ROG Gray fi 1 e CParrish KJohnston EJordan JPartlow ACRS (10)

DEisenhut DNeighbors JDonohew PMcKee OELD By letter dated January 17, 1977, the staff requested that you evaluate the previously unevaluated potential consequences of a postulated Fuel Handling Accident Inside Containment (FHAIC) at Surry Power Station, Units 1 and 2 (Surry 1/2). Enclosed is our safety evaluation of the fuel handling accident inside containment for Surry 1/2.

Our evaluation is based on our review of your letters dated July 5, 1977; August 5, 1977; March 7, 1978; and our approval dated April 9, 1984, of your request to increase burnup to 45,000 MWd/MTU.

We conclude that the potential consequences of an accident involving the handling of spent fuel inside containment are within the exposure guidelines of 10 CFR Part 100 and that no additional restrictions of fuel handling operations and plant operating procedures are needed.

As explained in the enclosure, our conclusion is contingent upon the installment of acceptable prefilters (i.e., ones that meet Regulatory Guide 1.52, Revision 2, Position C.3c) for the Auxiliary Building Ventilation System.

Enclosure:

Safety Evaluation cc w/enclosure:

See next page ORB#l:D~

KJohnst:frt'fts Ol/ /{) /85 Sincerely, Steven A. Varga, Chief Operating Reactors Branch #1 Division of Licensing o'tl D

  • bars 01 O /85 BC-ORB#l:DL SVarga 01/ /85

I I*

Mr. W. L. Stewart Virginia Electric and Power Company cc:

Mr. Michael W. Maupin Hunton and Williams Post Office Box 1535 Richmond, Virginia 23213 Mr. J. L. Wilson, Manager Post Office Box 315 Surry, Virginia 23883 Donald J. Burke, Resident Inspector Surry Power Station U.S. Nuclear Regulatory Commission Post Office Box 166, Route 1 Surry, Virginia 23883 Mr. Sherlock Holmes, Chairman Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 W. T. Lough Virginia Corporation Commission Division of Energy Regulation Post Office Box 1197 Richmond, Virginia 23209 Regional Radiation Representative EPA Region III Curtis Building - 6th Floor 6th and Walnut Streets Philadelphia, Pennsylvania 19106 Mr. J. H. Ferguson Executive Vice President - Power Virginia Electric and Power Company Post Office Box 26666 Richmond, Virginia 23261 James P. O'Reilly Regional Administrator - Region II U.S. Nuclear Regulatory Commission Suite 2900 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 James B. Kenley, M.D., Commissioner Department of Health 109 Governor Street Richmond, Virginia 23219 Surry Power Station Units 1 and 2 Attorney General 1101 East Broad Street Richmond, Virginia 05602