ML18142A182

From kanterella
Jump to navigation Jump to search
Provides Results of Drop Analysis of Transfer Canal Door Onto Spent Fuel Racks Per NUREG-0612.Overall Integrity of Spent Fuel Racks & Fuel Pool Floor Maintained
ML18142A182
Person / Time
Site: Surry  
Issue date: 02/01/1985
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Varga S
Office of Nuclear Reactor Regulation
References
REF-GTECI-A-36, REF-GTECI-SF, RTR-NUREG-0612, RTR-NUREG-612, TASK-A-36, TASK-OR 85-008, 85-8, NUDOCS 8502080250
Download: ML18142A182 (2)


Text

\\

J.I VIRGINIA ELECTRIC AND POWER COMPANY RtCHMOND, VIRGINIA 23261 W. L. STEWART VxcE PRESIDENT NUCLEAR OPERATIONS February 1, 1985 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

VIRGINIA POWER Serial No.85-008 E&C:SNK:klh:2012N Docket Nos: 50-280 50-281 License Nos: DPR-32 DPR-37 SURRY POWER STATION NOS. 1 AND 2 NUREG 0612 - CONTROL OF HEAVY LOADS PHASE II In Item 2.2.3 of our September 28, 1984 letter (Serial No. 336), we stated that we were performing a drop analysis of the transfer canal door onto the

~pent fuel racks and that the results of that analysis would be submitted to you.

The analysis has been completed and the results are as follows:

We have reviewed the report and have concluded that the overall integrity of the spent fuel racks, as well as the fuel pool floor, is maintained and the leak tightness of the liner is not compromised.

We believe that this analysis satisfies the evaluation criteria of NUREG-0612, Section 5.1.2.

The report, entitled 11 The Transfer Canal Door Drop Analysis for Surry Units 1 and 2 (NES Report No. 83A1040, Revision 2) 11

, is available in the corporate office for review.

Our letter also stated that a new transfer canal door storage rack will be installed for the Unit 2 transfer door.

This transfer door storage rack has been designed and is scheduled to be installed prior to the movement of the transfer door during the upcoming Unit 2 refueling.

Should you have any questions or require additional information, please contact us.

8502080250 850201 PDR ADOCK 05000280 P

PDR VDy tr~l.y y. ours,

( )1 /,Q_J

-.. * (_ J lR1v"A W. L. Stewart

r I

e VIRGINIA ELECTRIC AND POWER COMPANY TO cc: Mr. James P. 0 1 Reilly Regional Administrator Region II Mr. D. J. Burke NRC Resident Inspector Surry Power Station e

Mr. Harold R. Denton, Director