Requests Relief from ASME Section XI Hydrostatic Test Requirements.Alternate Testing Proposed Provides Necessary Insp & Integrity Insurance for All Affected Welds
ML18139C279
Person / Time
Site: Surry 
Issue date: 03/16/1983
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Varga S
Office of Nuclear Reactor Regulation
References
143, NUDOCS 8303210617
Download: ML18139C279 (3)


Text

e e

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 W. L. STEWART VxcE PRES:CDENT NUCLEAR 0PERAT'.CONS March 16, 1983 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Steven A. Varga, Chief Operating Reactors Branch 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:

Serial No. 143 NO/WDC:acm Docket No. 50-280 License No. DPR-32 RELIEF REQUEST FROM ASME XI HYDROSTATIC TEST SURRY POWER STATION UNIT 1 Surry Power Station Unit 1 will be performing a repair within a system boundary designated as ASME Class 2 during the refueling outage currently underway.

Pursuant to 10 CFR 50.55a paragraph g(5), relief is requested from certain post repair test requirements delineated in ASME Section XI.

The following basis is provided.

Specifically it is planned to replace three 1 1/2 inch socket welded drain valves (1-MS-266, l-MS-106, and l-MS-143) and one 2 inch socket welded manual isolation valve (l-GN-3), which are just downstream of the main steam trip valves (drawings attached).

The governing code ASME XI 80W80 requires a hydrostatic test (IWA 4400 and IWC-5222) for such a repair/replacement.

As evidenced by the attached drawings this replacement would require a

hydrostatic test of all three steam generators and a considerable portion of attached main steam piping.

This test is considered especially difficult and impractical in nature.

Alternate testing proposed is a surface examination (liquid penetrant) and a visual examination (VT-2) in conjunction with a system inservice pressure test (IWC-5221) during start-up, following the refueling outage.

This relief is identical in nature to previous relief requests for replacements on Surry Power Station Unit 1 (Serial No. 530, dated 9/15/82) and on Surry Power Station Unit 2 (Serial No. 680, dated 12/9/82).

Reliefs were granted for these replacements (dated 10/1/82 and 12/10/82).

It is our contention, that from the information provided, relief should be granted.

Alternative testing proposed provides for the necessary inspection and integrity insurance for all affected welds.

8303210617 830316 PDR ADOCK 05000280 P

PDR cc:

Mr. James P. O'Reilly, Director Office of Inspection and Enforcement Region II Very truly yours, l) _L, ~~:;:t

w. L. Stewart

~ I i I l

~W[ft ITATIO':. COM,AN

.U~~IC AND PO~

VIRGINIA EU m.AN..aIPtU no***------

FM-64AB

=11448-J!

I

--t-*-

,1, I *~*.J1

  • M l\\flA,oj< *.Jl

,A 1,.,,,

1**1

.,., *~**\\.**....

',,,'..IJf'f'LY 1'.QN*U*&ll-..

    • r,r.~ ~£ 1 e 16o P!.1G

r------

i,Nt'\\4

~r,,,,.,, 1

'~* -:*!..-;i ~ -

lrj~~--

,~----1------1-'2-_***_*~_-'".,__'-0--=-l+~~-,:* :.-*__:*:__* J* It*

" r

  • '.I~ 1(\\I( If.I> I r,,,,.!'J..

,*.t !',~,ii.

I'-' 64A

,,.. \\,18 VALVE OPPERATING NUMBERS _

STM GEN NITROGEN CONN SURRY POWER STATION V.

E.

C.

0.

11448-FM-648.:\\

J

  • r-j t

e