VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND~ VIRGINIA 23261 R.H. LEASBURG VICE PRESIDENT NUCLEAR OPERATIONS December 29, 1981 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:
Mr. Darrell G. Eisenhut, Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:
License Nos.
50-280 50-281 50-338 50-339 DPR-32 DPR-37 NPF-4 NPF-7 Inservice inspection hydrostatic tests at our Surry and North Anna Power Stations require a four hour test duration and a minimum temperature of lOOF.
The 1977 edition of ASME Section XI, with addenda through summer 1979, allows a 10 minute hydrostatic test for uninsulated surfaces and specifies a minimum test temperature only for ferritic steels.
Pursuant to 10CFR50.55(a),(g)(5)(iii), we are requesting relief from the 1974 code edition requirements in articles IWA 5000, IWB 5000, IWC 5000 and IWD 5000 and propose that the requirements in the same articles of the 1977 edition and approved addenda be applied at Surry and North Anna Power Stations.
We acknowledge that this is not. in conformance with Section (b) (2) (i) of 10CFR50.55(a), however, this exemption will not result in the inability of the inservice inspection program to meet the requirements of paragraph (g)(4) in that the alternative requirements being applied represent a more recent application of testing criteria.
cc:
Mr. James P. O'Reilly, Regional Administrator Region II Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Mr. Robert A. Clark, Chief Operating Reactors Branch No. 3
(* a201040020 s 11229 ""*
- i. ~DR ADOCK 05000290
'PDR I R.H. Leasburg