Forwards IE Info Notice 80-36, Failure of Steam Generator Support Bolting. No Specific Action or Response Requested
ML18139A771
Person / Time
Site: Surry, North Anna  
Issue date: 10/10/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Ferguson J
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
References
NUDOCS 8010290060
Download: ML18139A771 (3)


Text

  • '

e UNITED STATES e

NUCLEAR REGULATORY COMMISSION REGION II 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 OCT 1 O 1980 In Reply Refer To:

RII:JPO 50-338, 50-339 50-404, 50-405

&0;:280, 50-2._~

Virginia Electric and Power Company ATTN: J. H. Ferguson Executive Vice President-Power P. 0. Box 26666 Richmond, VA 23261 Gentlemen:

Gentlemen:

This Information Notice is provided as an early notification of a possible significant matter. It is expected that recipients will review the information for possible applicability to their facilities.

No specific action or response is requested at this time. If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Sincerely, Director

Enclosures:

1.

IE Information Notice No. 80-36

2.

List of Recently Issued IE Information Notices cc w/encl:

W.R. Cartwright, Station Manager P. G. Perry, Senior Resident Engineer J. L. Wilson, Manager

.:***,,~. ___.. ~-*

~

/.

,,.// I

/

(

e e

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 October 10, 1980 SSINS No.:

6835 Accession No.:

8006190085 IE Information Notice No. 80-36:

FAILURE OF STEAM GENERATOR SUPPORT BOLTING Uescription of Circumstances:

On September 4, 1980, the NRC staff was informed by the Northern States Power Company that extensive cracking of the bolting for the supports attached to bottom of the steam generators on Prairie Island Unit 1 had occurred.

The licensee initially discovered the bolting problem when two bolts failed during detensioning.

The licensee was attempting to remove the pre-load on the bolting (specified at 1400 ft-lbs) to minimize the potential for stress corrosion cracking of the high strength 1-1/2 in. dia. 250 ksi maraging steel' bolting (Vascomax 250).

Ultrasonic examination of the support bolting revealed cracks or breaks in 47 of 48 support bolts for the two steam generators at the Prairie Island Unit 1 facility.

The licensee subsequently shut down the Prairie Island Unit 2 facility and performed ultrasonic examinations of the same steam generator support bolting, that failed on Unit 1.

The results of the UT examinations revealed cracks in three of the 48 steam generator support bolts.

The licensee attempted to remove the cracked bolts from the steam generator supports.

Two cracked bolts were successfully removed while the third failed during removal.

Two bolts that were judged as defect free by the ultrasonic examination were also removed.

Magnetic particle examinations confirmed the results of the ultrasonic examinations on the bolts which were removed.

As part of the short term corrective actions taken, the licensee has unloaded and retensioned the bolting at approximately 50 to 100 ft.-lbs.

Inservice ultrasonic examination of the affected bolting had been performed previously.

In the case of Unit 1 a significant number of the bolts were examined at the last refueling outage 14 months ago.

No cracks were found at that time.

The susceptibility for stress corrosion cracking was identified in NUREG-0577 (for comment).

The NUREG identifies those facilities which have utilized maraging steels for reactor coolant pump and steam generator support bolting.

Further the NUREG recommends augmented inspections for the facilities included in Group I.

Licensees are encouraged to review the bolting materials used at their respective facilities and consider inspection of maraging steel bolting that are either pre-loaded or significantly loaded during operation.

This Information Notice is provided as an early notification of a possible significant matter that is still under review by the NRC staff. It is expected that recipients will review the information for possible applicability to their facility.

No specific action or response is requested at this time.

If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

t\\

Information Notice No. 80-36 80-35 80-34 80-33 80-32 80-31 80-30 80-29 Supplement to 80-06 80-28 80'."'21.

RE.CENTLY ISSUED IE INFORMATION NOTICES Date of Subject Issue Failure of Steam Generator

. 10/10/80 Support Folting Leaking and dislodged 10/10/80 Iodine-124 implant seeds Boron dilution of reactor 9/26/80 coolant during steam generator decontamination Determination of teletherapy 9/15/80 timer accuracy Clarification of certain 8/12/80 requirements for Exclu-sive-use shipments of radioactive materials e

Maloperation

  • of Gould-8/27 /80.

Brown Boveri Type 480 volt type K-6.00S and K-DON 600S circuit breakers Potential for unaccept-8/19/80 able interaction between the control rod drive scram function and non-essential control air at certain GE BWR facilities Broken studs on Terry turbine steam inlet*

flange Notification of significant events at operating power reactor facilities Prompt reporting of required information to NRC Degradation of reactor.

coolant pump studs_

8/7/80 7/29/80 6/13/80 6/11/80

  • Operating Licenses or Construction Permits IN 80-36 October 10, 1980 Issued to All nuclear power reactor facilities with an 01 or CP All categories G and Gl medical licensees All pressurized water reactor facilities holding power reactor 01s All teletherapy (G3) licensees All NRC and agreement state licensees All light water reactor facilities holding 01s or CPs All boiling water reactor facilities holding power reactor 01s or CPs..

All light water reactor facilities holding power reactor 01s or CPs*

All holders of reactor and near-term 01 applicants All applicants for and holders of nuclear power reactor CPs All. *pressurized water. -***. -

reactor facilities holding power reactor 01s or CPs