05000281/LER-1980-008-03, /03L-0:on 800623,while Performing Periodic Test 26.1,found Air Ejector Monitor Alarm Setpoint Above Tech Spec Requirement.Caused by Instrument Drift.Alarm Setpoint Recalibr

From kanterella
(Redirected from ML18139A454)
Jump to navigation Jump to search
/03L-0:on 800623,while Performing Periodic Test 26.1,found Air Ejector Monitor Alarm Setpoint Above Tech Spec Requirement.Caused by Instrument Drift.Alarm Setpoint Recalibr
ML18139A454
Person / Time
Site: Surry 
Issue date: 07/11/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139A453 List:
References
LER-80-008-03L-01, LER-80-8-3L-1, NUDOCS 8007180327
Download: ML18139A454 (2)


LER-1980-008, /03L-0:on 800623,while Performing Periodic Test 26.1,found Air Ejector Monitor Alarm Setpoint Above Tech Spec Requirement.Caused by Instrument Drift.Alarm Setpoint Recalibr
Event date:
Report date:
2811980008R03 - NRC Website

text

CON~'ROL BLOCK:

1,. l 8

!PLEASE PRINT OR TV.LL REQUIRED INFORMATION) l0 I 11' Iv IA I s IP Is I 210L..:I o-..i....=..lo__,1_--1..l.....::.o....1..l~o~l "'--o.L...:I o'--'1'--""o_..._l_-_._l-=--o ""'--'lo~l0l 411 I 1 I 1 I 1101 I 10 7

8 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE. TYPE JO 57 CAT SE CON'T J o 1, I 7

8

~:~~~ L!J©I o I 5 Io I o I o I 2 I s I 1 101 o I 6 I 2 I 3 1 s ~ a IG)I O I 7 11 I 1 I 81 °J0 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

I During the perfonnance of Perodic Test 26.1 it was discovered that the Air Ejector Jo j 3 I. Monitor (RM-SV-211) Alarm Setpoint was above the Technical Specification requirement Io I 4 I as stated in section 3.7.E Table 3.7.5.

This is reportable as per Technical

'j Io Is I Specification 6. 6. 2. b.

The Air Ejectors were not in service at this time therefore lo Is I there was no release.

The health and safety of the public were not affected.

0 7

0 8

8 9 m:

a 9

8 0

SYSTEM CODE IM I c!@

9 10 LE R/RO CV ENT YEAR ii~~~~ l,B I OJ

CAUSE

CAUSE CODE SUBCODE COMPONENT CODE L!J@) l!_J@ I 1 IN Is IT I RI tr I@

11 12 13 l.::::J 23 SEQUENTIAL REPORT NO.

I O I O I 8 I 24 26 18 OCCURRENCE CODE I o I 3 !

27 28 29 COMP.

SUBCODE LU 19 REPORT TYPE L!:J 30 VALVE SUBCODE

~@

20 L:=J 31 ACTION FUTURE EFFECT SHUTDOWN

(:;;\\

ATTACHMENT NiPRD-4 TAKEN ACTION ON PLANT METHOD HOURS ~ SUBMITTED FO!li!M SUB.

PRIME COMP.

SUPPLIER ul@~@ l3.J@

~

.I'::-_o..__I 0_.__I 0__,l.__0__.I LU@)

l!U@

33 34

  • 3!,

36 3 7 40 4 1 42 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

~

43 REVISION NO.

LQJ 32 COMPONENT MANUFACTURER I V j 1 I 1 I 5 ;l§ 44

,c; I This failure was caused by instrument drift in the high alarm setpoint.

At no time were the limits of 10CFR20 Appendix B or Technical Specification 3.11.B.8 exceeded.

I The setpoint was readjusted and the monitor returned to service.

9 l~...L--"'2_. -L------------~---------------------------------------'

4 B

9 FACILITY STATUS

% POWER OTHER STATUS BO DISCOVERY DISCOVERY DESCRIPTION 32 5 W§ B

9 ACTIVITY IO I O I O l@)!...._ __

NA ___

10 12 1'3 METHOD OF

@)

lJu@)IL-........::OLp-=-e-=-r-=a-=-t-=-o-=-rc....::O:.::b:..:s:..:e:..:r:..:v:..:a::.:t::.:i::..:o:.:n-=-----------~I.

CONTENT

~

RELEASED OF RELEASE AMOUNT OF ACTIVITY ~

D:I] uJ @) u.J@I NA B

9 10 11 ti

~

~

LOCATION OF RE~EASE @

45 NA 80 PERSONNEL EXPOSURES r:;;:;,.

NUMBER

~

TYPE

DESCRIPTION

O I O j O k:0~@L.._ ___

NA _______________________

11 1i 13 PERSONNEL *1NJURIES

~

NUMBER DESCRIPTION6 0 I O I O l@.__ _____

N_A ______________________

B 9

11 1;;,

B 9

80 BO LOSS OF OR DAMAGE TO FACILITY '4)\\

TYPE

DESCRIPTION

~

~@

NA B

9 10 PUBLICITY

~

8(

NRC USE ONLY ISSUED~ DESCRIPTION~

~6 "-:---=------------------------------..J

~ oso 11 s 1fi 3~T I I I I I I I I I I t I l i NA

  • 1. L. Wilson NAME OF PREPARER-------------------

66 69 PHONE:(804) 357-3184 SC ;;

a

ATTACHMENT 1

.. $UP~Y POWER STATION, UNIT e DOCKET NO:

50-281 REPORT NO:

80-008/03L-0 EVENT DATE:

06-23-80 e

TITLE OF REPORT:

RADIATION MONITOR (RM-SV-211) SET POINT DRIFT

1.

Description of Event

While performing Perodic Test 26.1 the Air Ejector Radiation Monitor Alarm Setpoint was found to be higher than allowed by Technical Specificatio~

3.7.E Table 3.7.5.

This is reportable as per Technical specification 6.6.2.b.(4.

2.

Probaole Consequences and Status of Redundant Systems:

The Air Ejectors for Unit two were not in service, therefore, there was no release and the health and safety of the public were not affected.

3.

Cause

The high alarm setpoint was caused by instrument drift in the Radiation Honitor (RM-SV-211).

4.

Immediate Corrective Action

Recalibrated Tuigh Alarm Setpoint.

5. Subsequent Corrective Action:

None required

6. Actions Taken to Prevent Recurrance No further action required.

The Periodic Testing program is designed to lo:~::-=.

this type of failure.

7. Generic Implications None