Forwards IE Info Notice 80-07, Pump Shaft Fatigue Cracking. No Response Required
ML18138A094
Person / Time
Site: Surry, North Anna  
Issue date: 02/29/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Ferguson J
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
References
NUDOCS 8003190055
Download: ML18138A094 (5)


Text

c,'-~R REG<,<.,

(~:~}

ca.

~

~

~

~o

        • -lit In Reply Refer To:

RII:JPO 50-338, 50-339 50-404 50-405

~-2so: 50-2sl:>

e UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 Ff 8 2 9 1980 Virginia Electric and Power Company Attn:

J. H. Ferguson Executive Vice President-Power P. 0. Box 26666 Richmond, VA 23261 Gentlemen:

.. ::i)',-.*:.

This Information Notice is provided as an early notification of a possible significant matter. It is expected that recipients will review the informa-tion for possible applicability to their facilities.

No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to rec,ommend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Enclosures:

1.

IE Information Notice No. 80-07

2.

List of Recently Issued IE Information Notices Sincerely,

--.. ~

r

/-

\\**~~-

1

-..__~es~P*.* O'Rei~

Director sooa1 soo.r s

Virginia Electric and Power Company cc w/encl:

W.R. Cartwright, Station Manager Post Office Box 402 Mineral, Virginia 23117 P. G. Perry Senior Resident Engineer Post Office Box 38 Mineral, Virginia 23117 W. L. Stewart, Manager Post Office Box 315 su*rry, Virginia 23883 i

e UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 February 29, 1980 e

SSINS No. :

6870 Accession No.:

7912190675 IE Information Notice No. 80-07 PUMP SHAFT FATIGUE CRACKING On October 9, 1979, the Tennessee Valley Authority (TVA) reported to NRC that low-stress high-cycle fatigue cracks had been found in two non-safety-related feedwater pumps at their Browns Ferry BWR facility.

One pump had been operated for approximately 20,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> and the other for approx{mately 28,000 hou~s.

  • TVA indicated that excessive vibration had been experienced prior to detection of the cracks by ultrasonic and visual inspection.

TVA also reported that catastrophic failure had been experienced with a boiler feed pump at their Paradise fossil unit.

The TVA failed pump shafts were of type 414 stainless steel.

TVA,plans. to replace the shafts with a type 17-4ph stainless steel.

A number of centrifugal charging/safety injection pump shaft failures have been reported since 1977.

The pumps of interest are the dual purpose centrifugal pumps which are utilized for a normal charging function and in the safeguard mode are aligned for high pressure borated coolant injection.

These pumps were procured by Westinghouse from the Pacific Pump.Division of Dresser Industries.

The pump shaft material was supplied-to Pacific Pump by the Carpenter Technology Corporation.

Westinghouse and Pacific Pump have been conducting an on-going investigative program since 1977 to resolve the shaft failure problem.

Results from the program suggested that the causes of the* shaft failures could be related to shaft material deficiencies, desigp and/or abnormal operation of the centrifugal pumps.

Forty centrifugal charging/safety.injection pump shafts fabricated from four heats of A276 type 414 stainless steel bar were air cooled and tempered at 1000°F.

The above stated heat treating practice resulted in shafts with low toughness (Charpy "V" notch energies - Longitudinal 6-10 ft-lbs, transverse 2-3 ft-lbs).

Corrective actions taken to reduce the incidence of charging pump/safety injection pump shaft failure have included:

1.

Replacement of the type 414 low toughness stainless steel material.

Replacement material for the charging pump shafts is type 414 stainless steel, oil quenched and tempered at 1150-1200°F.

Some of the air cooled shafts have been re-:tempered at 1150°F.

I

2.

Design modifications to the shaft to reduce stress raisers.

The modifica-tions included increasing the fillet radius in the split ring groove, increasing the thread root in the locknut section of the shaft and the use of formed cutting tools during fabrication.

~*

i

IE Information Notice No. 80-07 February 29, 1980 Page 2 of 2

3.

A review of the operating history of the dual purpose centrifugal pumps indicate abnormal operation to be a potentially significant contributor to the early failure of the pump shafts.

Abnormal operation includes any condition that results in partial or complete loss of fluid in the pump or continued operation under high vibration conditions caused by misalign-ment or other installation problems.

Westinghouse Nuclear Service Division's Technical Bulletins 77-9, 78-1 Rev. 1 and 79-6 provide guidance for monitoring of and limits for pump vibration as well as guidance for pump operation and maintenance.

Ten additional Safety Injection Pumps manufactured by Pacific Pump were identified as having shafts with the same material and heat treatment as the failed charging/safety injection pump shafts.

These ten additional pumps are of a different design and provide for medium pressure boron injection in ~he safeguard mode but do not function in normal operation.

Licensees are encouraged to review the materials utilized for and the design of shafts in safety-related pumps and non-safety-related pumps which could affect safety-related system performance.

Particular attention should be paid to abnormal operating conditions which could induce high stress in the pump shafts, susceptibility of materials to crack initiation and growth, and the presence of stress raisers.

This Information Notice is provided as an early notification of a possible significant matter that is still under review by t!J.e NRC staff. It is expected that recipients will review the information for possible applicabil-ity to their facility.

No specific action or response is requested at this time.

If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

~-

e IE Information Notice No. 80-07 February 29, 1980 RECENTLY ISSUED Information Notice No. 80-07 80-06 80-05 80-04 80-03 80-02 80-01 79-37 79-36 79-35 79-34 79-33 79-32 IE INFORMATION NOTICES Subject Pump Shaft Fatigue Cracking Notification of Significant Events Chloride Contamination of Safety Related Piping BWR Fuel Exposure in Excess of Limits Main Turbine Electro-Hydraulic Control System 8X8R Water Rod Lower End Plug Wear Fuel Handling Event~

'(

Cracking in Low Pr~ssure Turbine Discs Computer Code Defect in Stress Analysis of Piping Elbow Control of Maintenance and Essential Equipment Inadequate Design of Safety-Related Heat Exchangers Improper Closure of Primary Containment Access Hatches Separation of Electrical Cables for HPCI and ADS Date Issued 2/29/80 2/27/80 2/8/80 2/4/80 1/31/80 1/25/80

  • 1/4/80 12/28/79 12/31/79 12/31/79 12/27 /79 12/21/79 12/21/79.

~..

Enclosure Issued To All holders of power reactor OLs and CPs All holders of Reactor OLs and to near term OL applicants All licensees of nuclear power reactor facilities and applicants and holders of nuclear power reactor CPs All BWR's_holding a power reactor OL or CP All holders of power reactor OLs and CPs All BWR Facilities holder power reactor OLs or CPs All holders of power reactor OLs and CPs All power reactor OLs and CPs All power reactor OLs and CPs All power reactor facilities with an OL or CP All holders of power reactor OLs and CPs All power reactor facilities holding OLs and CPs All power reactor facilities holding OLs and CPs