Industry Response to Flowserve Part 21 on Anchor Darling Double Disk Gate Valves and NRC Staff Next Steps Public Meeting May 16, 2018 1

Overview

  • Operating Experience has identified failures of Anchor/Darling (A/D) Double Disk Gate Valves (DDGVs)
  • Significant progress has been made

- Industry has developed guidance

- All licensees have submitted information on the affected valves, including commitments for valve repairs

  • It appears that industry is taking steps to address the issue
  • The NRC staff is preparing to inspect licensees corrective actions
  • The NRC staff continues to assess the need for a Generic Communication, but does not plan one at this time 2

=

Background===

  • Failure of A/D DDGV at Browns Ferry in 2013 revealed that threaded stem-to-wedge connection had not been properly torqued
  • Flowserve Part 21 notification February 25, 2013

- Recommended assessing wedge pin susceptibility to shear and rework the valve if needed

  • BWROG developed guidance to address Part 21 to include:

- Prioritization and Screening Criteria

- Evaluation Methods

- Inspection and Diagnostics

- Repair Methods 3

Background (cont.)

  • NRC staff evaluated 2013 Part 21 and determined the issue would be monitored with no generic communication
  • Additional failures occurred at LaSalle Unit 2 and Columbia
  • LaSalle event elevated to NRC special inspection
  • Information Notice (June 2017)
  • BWROG updated guidance to Rev. 4 (August 2017)
  • NRC staff considered need for generic communication due to larger population of failures and limited information readily available to the staff 4

Progress to Date

  • NRC staff held public meetings on guidance and licensee corrective actions

- Staff requested clarification of guidance (October 2017)

- NEI provided clarification (November 2017)

  • All licensees submitted information (December 2017)

- Valve population

- Valve characteristics (susceptible, non susceptible, risk category)

- Rework status

- Commitments for future repairs

- Public Data Compilations are in ML18053A023 and ML18053A904

  • NRC staff held public meeting February 15, 2018

- Staff discussed guidance document, licensee corrective actions, and future plant inspections 5

Scope of Meeting

  • Discuss the draft Temporary Instruction (TI) developed to inspect and assess industry progress on addressing Flowserve Part 21 issue on A/D DDGV
  • Discuss inspection plan and schedule 6

NRC Temporary Instruction Scope

  • Identify

- Verify licensee properly identified valves population (2 inch valves and larger with a stem-to-disc threaded connection design and an actuator that applies torque to the stem)

  • Evaluate

- Evaluate actuator force for impact on valve integrity

- Evaluate torque/shear on pin to determine whether valve susceptible

  • Review

- Review history of valve operation and plans for monitoring possible over torque events if licensee does not use maximum torque

- Review risk categorization

- Evaluate planned corrective actions 7

Identify

  • Verify licensee has identified the A/D DDGV population

- Valve size

- Motor and Actuator type and size

- Plant system

- Valve function

- Normal valve position

- Valve operational requirements (open, closed, or both, cycles)

- Stem/Disc connection (threaded or T-head)

- Stem collar type (pressed on fit or integral)

- Safety risk category (high, medium, or low)

- Previous test and/or repair results 8

Evaluate

  • Calculate maximum load stall torque applied

- Standard industry motor stall torque equation

- Motor stall torque value obtained from motor curve. If unavailable, motor stall torque estimated value will be 110% of rated motor torque

- Actual voltage at the motor needs to be considered

  • Evaluate maximum test torque applied

- NRC staff recognizes that a large percentage of actuators have maximum stall torque values that are greater than the capability of the valve components

- If test max torque is used, evaluate how licensee will manage possible future motor stall events 9

Evaluate (cont.)

  • Considerations for managing possible motor stall events

- Wedge pin shear capability has been included in the weak link analysis

- Procedures have been updated as necessary

- Valve has been modified to lower actuator capability and/or valve components replaced with stronger materials

- Valve drawings have been updated with Part 21 information regarding pressed fit collars and/or updated to reflect pressed fit collar being replaced with an integral stem

- Preventive maintenance (PM) activity has been updated to monitor and assess motor control center (MCC) contactor mechanical performance and/or have a periodic contactor replacement strategy 10

Evaluate (cont.)

  • Evaluate applied force

- Torque, thrust, stem factor, coefficient of friction (COF)

- If COF is unknown, a value of.08 shall be assumed. This value is based on historical test data

  • Calculate stem and wedge thread shear capability

- ASME B1.1-2003 Unified Inch Screw Threads (UN and UNR thread form)

  • Compare applied force vs stem and wedge thread shear
  • Calculate wedge pin shear capability
  • Compare applied force vs wedge pin shear
  • Stress values based on BWROG guidance 11

Evaluate (cont.)

  • Evaluate credit for thread resistance

- BWROG guidance allows reasonable engineering judgement

- NRC staff notes there is no accepted guidance available regarding how to credit thread friction to resist applied torque

- NRC staff considers thread resistance should only be used to determine valve operability for the short term and should not be relied upon for a long term fix

- NRC staff considers 0.1 friction factor as a reasonable value for the short term.

- NRC staff considers use of higher COF values warrants additional attention until the valve can be reworked (e.g., stem rotation check during each quarterly valve exercise) 12

Review

  • History

- Review susceptible A/D DDGV maintenance and test history

  • Risk

- Review methodology used to apply risk

- Review valve risk ranking

  • Actuator Capability vs Valve Components

- Review licensee calculations

- Calculations must use conservative factors such as applying actual voltage to motor and coefficient of friction on the stem/stem nut interface. Licensees may use actual test data with conservatism for expected variation and measurement uncertainties 13

Review (cont.)

- Review valve structural capability and weak link calculations

  • Corrective action plan

- Review adequacy and the timeline to complete repairs. Justification is required for the schedule that exceeds the specifications of the stated valve categories in BWROG guidance

  • Reworked Valves

- A sample will be selected and reviewed to determine if the rework meets Flowserve Part 21 recommendations

  • Process

- Review licensee process to ensure susceptible A/D DDGV provides reasonable assurance that the valves will be able to perform their safety function 14

NRC Inspection Plans

  • NRC draft Temporary Instruction will be finalized following todays public meeting
  • NRC staff is developing an inspection sample

- Initial inspection plan is to select two or three plants per region

- Evaluation of the first plants inspected will determine if additional inspections are needed

- Estimated inspection time is 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> (2 inspectors for one week) 15

NRC Next Steps

  • Finalize TI (May 2018)
  • TI inspections (2018 into 2019)
  • Continue to update NRC assessment on need for generic communication 16

QUESTIONS?

Future Questions Stewart.Bailey@nrc.gov 301-415-1321 Michael.Farnan@nrc.gov 301-415-1486 17