NLS2018025, 10 CFR 50.55a Relief Request RI5-03 Supplement

From kanterella
(Redirected from ML18131A159)
Jump to navigation Jump to search

10 CFR 50.55a Relief Request RI5-03 Supplement
ML18131A159
Person / Time
Site: Cooper 
Issue date: 04/26/2018
From: Dent J
Nebraska Public Power District (NPPD)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NLS2018025
Download: ML18131A159 (2)


Text

,.

/

Nebraska Public Power District NLS2018025 April 26, 2018 U.S. Nuclear Regulatory Corinnission

  • Attention: Document Control Desk Washington, D.C. 20555-0001 Alwa,s there when,ou need us

Subject:

10 CFR 50.55a Relief Request RI5-03 Supplement Cooper Nuclear Station, Docket No. 50-298, DPR-46 50.55a

Reference:

Teleconference between Thomas Wengert et al., U.S. Nuclear Regulatory Commission, and David Van Der Kamp et al., Nebraska Public Power District, on April 19, 2018

Dear Sir or Madam:

The purpose of this letter is for Nebraska Public Power District to respond to a question raised during the teleconference (Reference) conducted on April 19, 2018. Nuclear Regulatory Commission reviewers questioned if Cooper Nuclear Station (CNS) intends to perform VT~ 1 visual examination of Category B-D, Item 3.100, Nozzle Inner Radius, in accordance with American Society of Mechanical Engineers Code Case N-648-1 as conditioned in Regulatory Guide 1.147. The staff did not see Code Case N-648-1 addressed in the application.

Code Case N-702 stipulates that VT-1 examination may be used in lieu of the volumetric examination for the inner radii (Item No. B3.100). CNS intends to credit the VT-1 visual examination of the nozzle inner radii in accordance with Code Case N-648-1 or later approved version subject to the conditions placed upon the use of the applicable N-648-X version of the Code Case by Regulatory Guide 1.14 7 at the time of the examination. The specific aspect of utilizing VT-1 visual examinations as allowed by Code Case N-702 is not part of this request.

Volumetric examinations of the nozzle inner radii of the selected core spray, jet pump instrumentation, and reactor recirculation inlet nozzles will still be performed as their nozzle inner radii are not fully accessible from inside the vessel for VT-1 visual examination.

This letter contains no regulatory commitments.

COOPER NUCLEAR STATION P.O. Box 98 / Brownville, NE 68321-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5211 www.nppd.com

NLS2018025 Page 2 of2 Should you have any questions regarding this submittal, please contact Jim Shaw, Licensing Manager, at ( 402) 825-2788.

Sincerely,

~~

John Dent, Jr.

Vice President-Nuclear and Chief Nuclear Officer

/dv cc:

Regional Administrator USNRC - Region IV Cooper Project Manager USNRC - NRR Plant Licensing Branch IV Senior Resident Inspector USNRC-CNS NPG Distribution CNS Records