Forwards Safety Evaluation of VEPCO 790808 Tech Specs Change Re Mods to Safety Injection Actuation Sys Logic
ML18130A630
Person / Time
Site: Surry  
Issue date: 08/23/1979
From: Lainas G
Office of Nuclear Reactor Regulation
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML18130A631 List:
References
NUDOCS 7909210008
Download: ML18130A630 (3)


Text

'

i PSB Reading MEMORANDUM FOR:

A. Schwencer, Chief, Operating Reactors Branch #1, DOR FROM:

SUBJECT:

G. Lainas, Chief, Plant Systems Branch, DOR SAFETY EVALUATION REPORT - SURRY NUCLEAR POvJER.

PLANT, UNITS l AND 2 - EVALUATION OF SAFETY INJECTION SYSTEM ACTUATION TECHNIC/-'.L SPECIFICATION CHANGE REQUEST (TACS 12010 AND 12011)

The Pl ant Syst_ems Branch has reviewed the Virginia Electric and Power Company 1s submittal of August 8, 1979, in which tne licensee pequested amendments to Facility Operating Licenses DPR-32 and DPR-37 to incorporate changes to the Technical Specifications for the-Surry*Power Station, Units l and 2.- The proposed changes are the result of IE Bulletin No.79-06A dated April 14*9 1979.

The amendments propose changes to the Technical Specifications which relate to modifications to the Safety Inject*ion (SI) actuation system logic. The proposed change requests that safety injection be initiated from only low pressurizer pressure using a two-out-of..:three logic thus eliminating aJl dependancy on pressurizer level for SI protection.

Based on our review, we conclude that the modffications to the SI

. actuation system logic satisfy the requirements of IEEE Std. 279-1971

  • and that the associttep Technical Specifications are correct; and

.therefore, are acceptable.

Our Safety Evaluation Report is enclosed.

Enclosure:

As stated

Contact:

R. Kendal 1 X-28077 G. Lainas, Chief Plant Systems Branch Division of Operating Rea-ctors Mite FORM 318 (9*76) NRCM 0240

  • u.o. GOVC<RNMl[NT PRINTING o,.,;1c1<: 1011 * ***,- ***

7' 9 0 9 21 0) (3 0

~..,

e e

MEMORANDUM FOR:

A. Schwencer, Chief, Operating Reactors Branch #1, DOR FROM:

G.' Lainas, Chief, Plant Systems Branch, DOR

SUBJECT:

SAFETY EVALUATION REPORT - SURRY NUCLEAR POWER PLANT, UNITS l AND 2 - EVALUATION OF SAFETY INJECTION SYSTEM ACTUATION TECHNICAL SPECIFICATION CijANGE REQUEST (TACS 12010 AND 12011)

The Plant Systems Branch has reviewed the Virginia Electric and Power Company's submittal of August 8, 1979, in which the licensee requested amendments to Facility Operating Licenses DPR-32 and DPR-37 to incorporate changes to the Technical Specifications for the Surry Power Station, Units 1 and 2.

The proposed changes are the result of IE Bulletin No.79-06A dated April 14, 1979.

The amendments propose changes to the Technical Specifications which relate to modifications to the Safety Injection (SI) actuation system logic. The proposed change requests that safety injection be initiated from only low pressurizer pressure using a two-out-of-three logic thus eliminating all dependancy on pressurizer level for ~I protection.

Based on our review, we conclude that the modifications to the SI actuation system logic satisfy the requirements of IEEE Std. 279-1971 and that the associated Technical Specifications are correct; and therefore, are acceptable.

Our Safety Evaluation Report is enclosed.

Enclosure:

As stated

Contact:

R. Kendall X-28077

(/~~

/G: Lainas, Chief Plant Systems Branch Division of Operating Reactors

cc w/enclosure:

D. Eisenhut R. Vollmer B. Grimes G. Lainas D. Ross D. Neighbors D. Tandi R. Scholl P. Shemanski R. Kendal 1 e