ML18130A585

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in IE Insp Repts 50-280/79-25 & 50-281/79-37
ML18130A585
Person / Time
Site: Surry  
Issue date: 08/15/1979
From: Kenna W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Proffitt W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
Shared Package
ML16216A343 List:
References
NUDOCS 7909180551
Download: ML18130A585 (3)


See also: IR 05000280/1979025

Text

e

(:JI.I' REG<,, _

.. c.'-'

-I>,

!~~,

. 0*1

i

.

~

'<.<

.

£'

-,...,

~o

        • ~

In Reply Refer To:

RII:WJT

50-280/79-25

50-281/79-37

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTA ST., N.W., SUITE 3100

ATLANTA, GEORGIA 30303

AUG 1 5 1979

Virginia Electric and Power Company

Attn:

W. L. Proffitt

Senior Vice President, Power

Post Office Box 26666 *

Richmond, Virginia

23261

Gentlemen:

Thank you for your letter of July 18, 1979, informing us. of steps you have taken

to correct the items of noncompliance concerning activities under NRG Operating

Nos. DPR-32 and DPR-31 brought to your*attention in our letter of June 22, 1979.

We have examined your corrective actions and have no further questions ~t this

time.

We appreciate your cooperation with us.

cc:

W. L. Stewart, Manager

Post Office Box 315

Surry, Virginia

23883

Sincerely,

f(~.

.. ~-

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTA ST., N.W., SUITE 3100

ATLANTA, GEORGIA 30303

In Reply Refer To:

SEP 2 1 1979

RII:HLW

50-280/79-47

50-281/79-66

(j

Virginia Electric and Power Company

ATTN:

W. L. Proffitt

Senior Vice President, Power

P. ,o. Box 26666

Richmond, VA 23261

Gentlemen:

This refers to the inspection conducted by H. L. Whitener of this office on

August 1-3, 1979, of activities authorized by NRC Operating License Nos. DPR-32

and DPR-37 for the Surry facility, and to the discussion of our findings held

with Mr. Wilson at the conclusion of the inspection.

Areas examined during the inspection and our findings are discussed in the

enclosed inspection report.

Within these areas, the inspection consisted of

selective examinations of procedures and representative records, interviews with

personnel, and observations by the inspector.

Within the scope of this inspection, no items of noncompliance were disclosed.

We have examined actions you have taken with regard to previously reported

unresolved items. The status of these items is discussed in the enclosed report.

In accordance with Section 2.790 of the NRC's "Rules of Practice", Part 2, Title

10, Code of Federal Regulations, a copy of this letter and the enclosed inspection

report will be placed in the NRC's Public Document Room. If this report contains

any information that you (or your contractor) believe to be proprietary, it is

necessary that you make a written application within 20 days to this office to

withhold such information from public disclosure.

Any such application must

include a full statement of the reasons on the basis of which it is claimed that

the information is proprietary, and should be prepared so that proprietary

information identified in the application is contained in a separate part of the

document. If we do not hear from you in this regard within the specified period,

the report will be placed in the Public Document Room.

7 911 0 5 04-1.J

'-<

Virginia Electric and Power Company

-2-

SEP 2 1 1979

Should you have any questions concerning this letter, we will be glad to discuss

them with you.

Sincerely,

.e.c. I

._

R. C. ~ing Chief

_

Enclosure:

Inspection Report Nos. 50-280/79-47

and 50-281/79-66

cc w/encl:

W. L. Stewart, Manager

P. 0. Box 315

Surry, VA

23883

Reactor Operations and Nuclear

Suppor't Branch

/