Entergy Operations, Inc.
17265 River Road Entergy KWona,LA7OO573O93 jdinell@ entergy.com John C. Dinelli Site Vice President Waterford 3 W3F1 -2018-0026 May 8, 2018 u.s_ Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001
SUBJECT:
Supplement to License Amendment Request for Use of RAPTOR-M3G Code for Neutron Fluence Calculations for Water[ord Steam Electric Station, Unit 3 (Waterlord 3)
Docket No. 50-382 License No. NPF-38
REFERENCES:
1 Entergy letter W3F1 -201 7-0065 License Amendment Request for Use of RAPTOR-M30 Code for Neutron Fluence Calculations, Waterford Steam Electric Station, Unit 3 dated November 27, 2017 2.
Westinghouse letter LTR-NRC-1 8-5 Response to the NRC Request for Additional Information on the RAPTOR-M3G and FERRET Topical Report dated January 18, 2018, ADAMS ML18018B347
Dear Sir or Madam:
By letter dated November 27, 2017, Entergy Operations, Inc. (Entergy) submitted a license amendment request for approval to use the RAPTOR-M3G code for neutron fluence calculations (Reference 1).
In letter dated January 1 8, 201 8 (Reference 2), Westinghouse provided responses to several Requests for Additional Information (RAIs) concerning their RAPTOR-M3G and Ferret topical report.
The information in Reference 2 provides details and clarification regarding RAPTOR-M3G as a neutron fluence calculation method, and supplements the information provided in Reference 1.
Therefore Entergy submits the information in Reference 2 as a supplement to Reference 1 for Staff consideration.
There are no new regulatory commitments contained in this submittal.
If you require additional information, please contact the Regulatory Assurance Manager, John Jarrell, at 504-739-6685.
W3F1 -2018-0026 Page 2 of 2 cc:
Kriss Kennedy Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 E. Lamar Blvd.
Arlington, TX 76011-4511 NRC Senior Resident Inspector Waterlord Steam Electric Station Unit 3 P.O. Box 822 Killona, LA 70066-0751 U. S. Nuclear Regulatory Commission Attn: Phyllis Clark Division of License Renewal Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Attn: Dr. April Pulvirenti Washington, DC 20555-0001 Louisiana Department of Environmental Quality Office of Environmental Compliance Surveillance Division P.O. Box 4312 Baton Rouge, LA 70821-4312 Frances.Ramirez@ nrc.gov Chris.Speer@ nrc.gov Phyllis.Clark @ nrc.gov I declare under penalty of perjury that the foregoing is true and correct. Executed on May 8, 2018.