MAINE YANKEE INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Nos. DPR-36 and SFGL-14 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January-December 2017 April 2018 Prepared by:
Radiation Safety & Control Services 91 Portsmouth Avenue Stratham, NH 03885-2468
EXECUTIVE
SUMMARY
Tables 1 and 2 summarize the quantity of radioactive gaseous and liquid effluents, respectively, for each quarter of 2017. There were no gaseous or liquid releases in 2017. Table 3 summarizes waste shipped off-site for disposal for each half year of 2017. There was no waste shipped for disposal in 2017.
Appendices A and B indicate the status of reportable items per the requirements of the Off-site Dose Calculation Manual (ODCM). There were no reportable items in 2017.
Appendix C presents any changes in the ODCM. The ODCM was not revised in 2017.
MY 2017 Annual RER Report Page 2 of 15
Table 1 MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents-Summation of All Releases NucHd&s Rel Total Release Ci Ci/s N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable N/A*
There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 3 of 15
Table 1A MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Ground Level Releases - Batch Mode Nuclides Released Unit 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter Total
- 1m:IrE*;cw '*0"*'1::*-V4'.iitifilllli(:~::1::::E};s;:i~ ff;:li '"'
- i:*{!,,;,.. :,';(:,i1t2 i'.;{:'.:~!: J.1i.::.:*,
h,,
\\;.,,\\i/~;l;;},{i: ~~~;;:
'1' J*;;.* ~1S$t.. n.... $
. fHffl+/-
- *".> n*?:fi\\> "'>F '.f':
~"t:- "V:~ >==::
Krypton-85 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-138 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
- i!1aa.rr~;,-~!z1Jt;~,
- fi;,*,i,S '. -i
'::1?1:,.~ ~i'0i{ ::;:;;:,, *:}:{II,m:f
.*. "***<?ti lodine-131 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
- l3~!arlJiiJl.lt~*ti~ti~!-~s'tft,{Jtff,'
- ,;.tffll VX**';
- ;;;h:~)}il{f.. ~*
~ *
,,*p;";'
z, 'XI\\\\f -*~*"\\_'}~Z,.
Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Bariu m-Lanth anum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 4 of 15
Table 1B MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Ground Level Releases - Continuous Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter M !'~:~,,,.,.... l~ ',:':'
,*.,wc'~,,,;;:::.,;F/}'.fi)~~iifr};d/@ii1t"
,.-1*
- ~',;
'/'/; >,,.-,.~
.%:I *.,I,--~
'~<,)Y--'
,<,m
,, st'i';p'.J,i',,:1,;,:,f,:+;,'J~
Krvpton-85 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-135m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-138 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
- 2er*a*""'Y*i~
- t Q. Jn~Ji;._
,.,:/
"/ \\]%1%
' t,, ;£1/(e?',, ":*:o:;,; r"i:,r}t -*,..
\\,i'.'i;,£, ~.-:@;:**Im -
,-u,,..,,%,
',.;,_g,f lodine-131 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
1::!!t:earfi!u1ata11:1t1'fttfr~:-*11::tf:fi7tti~;~t~ ~,,,,,, ~
11,c
,,,,, ~
Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 5 of 15
Table 1C MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Elevated Releases - Batch Mode Nuclides Released Unit 1st Quarter 2nd Quarter 3rd Quarter Krypton-85m Ci N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
Xenon-135 Ci N/A*
N/A*
N/A*
Xenon-135m Ci N/A*
N/A*
N/A*
Xenon-138 Ci N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
4th Quarter N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
Total N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
'"°'.7'<1r rtki>1K::tfii
- j;;~"i1
~ "'
,<<:: t1i.liL,,}Ilr'; ;:' F"',Y~
!H:~. :y;:,'J'{/1;
- '.?J L.'ztrt@J(;l ;**;;*,y;;.VJY};)ff",';
3;,;,;:,.. ;.~<;::::**;;:,
lodine-131 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
lodine-135 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
1;:.3:tJ~ai:th;ulaiifVi}li!1t2,:;,1*~,,::,,:.~
~a'., :.i!:~!tt:;fo;~,i;:.::::zrh&J...*.
,, 11 Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 6 of 15
Table 1D MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2017 Gaseous Effluents - Elevated Releases - Continuous Mode Nuclides Released Unit 1st 2nd 3rd 4th Quarter Quarter Quarter Quarter
&1,~,lit p,i()h1at£Spfj;;*\\i.. ll:
'**v2F
.. r>1n * ;;\\-:FitY'lii X w ;~ '"""' "'", ".'~./?~1 :~&'0'.ifi:~;
Krvpton-85 Ci NIA*
NIA*
NIA*
NIA*
Krvpton-85m Ci NIA*
NIA*
NIA*
NIA*
Krvpton-87 Ci NIA*
NIA*
NIA*
NIA*
Krvpton-88 Ci NIA*
NIA*
NIA*
NIA*
Xenon-133 Ci NIA*
NIA*
NIA*
NIA*
Xenon-135 Ci NIA*
NIA*
NIA*
NIA*
Xenon-135m Ci NIA*
NIA*
NIA*
NIA*
Xenon-138 Ci NIA*
NIA*
NIA*
NIA*
Unidentified Ci NIA*
NIA*
NIA*
NIA*
Total fo~
Ci NIA*
NIA*
NIA*
NIA*
- t.
- ii'I1F:ii.11.*':ti+ir*ms:*,:,,:,:;J~
'"',>1:;.;;,,.>.,,;,,~,,"\\:;,~
Ill t:
w lodine-131 Ci NIA*
NIA*
NIA*
NIA*
lodine-133 Ci NIA*
NIA*
NIA*
NIA*
lodine-135 Ci NIA*
NIA*
NIA*
NIA*
Total for period Ci NIA*
NIA*
NIA*
NIA*
- ~sr'.Panr~u1itis'.~&1151;t<~,.-.~;;~.; ___
~1]~;:i:,;ui,0, ~f/C.,,,w,*~~ ~t;itj{j/M;} /0 a
.,/:*y Strontium-89 Ci NIA*
NIA*
NIA*
NIA*
Strontium-90 Ci NIA*
NIA*
NIA*
NIA*
Cesium-134 Ci NIA*
NIA*
NIA*
NIA*
Cesium-137 Ci NIA*
NIA*
NIA*
NIA*
Cobalt-60 Ci NIA*
NIA*
NIA*
N/A*
Barium-Lanthanum-140 Ci NIA*
NIA*
NIA*
NIA*
Others-Plutonium-238 Ci NIA*
NIA*
NIA*
NIA*
Curium-243,244 Ci NIA*
NIA*
NIA*
NIA*
Uranium-234 Ci NIA*
NIA*
NIA*
NIA*
Uranium-238 Ci NIA*
NIA*
NIA*
NIA*
Thorium-232 Ci NIA*
NIA*
NIA*
NIA*
Radium-226 Ci NIA*
NIA*
NIA*
NIA*
NIA*= Not Applicable Total
~
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
- .;_.,:*,.. l'\\'.;iF\\S~*
NIA*
NIA*
NIA*
NIA*
,[Li's: *,=,,,, '*<{ '\\,ti
- };'.i:C:**,,,,,,,,.A1Wt.lt' NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
NIA*
There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 7 of 15
Table 2 MAINE YANKEE ISFSI Effluent and Waste.Disposal Annual Report 2017 Liquid Effluents - Summation of All Releases NU&lides: Releaseit/: :,i~n:* Unit;
. :1st *.((~f'*d,<,...
~iGtdt.
I<\\
>, '{*,,<j::c:,
~fr::\\ :
- _-,; > /'.:~~\\~~~~'.c;/: Quarter
~. *t>**
ddartiiir k'
artert**
A. Fission and Activation Products Total Release (not including Ci N/A*
N/A*
N/A*
tritium, qases, alpha)
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
durinq period Percent of applicable limit N/A*
N/A*
N/A*
B. Tritium Total Release Ci N/A*
N/A*
N/A*
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
during period Percent of applicable limit N/A*
N/A*
N/A*
C. Dissolved and Entrained Gases Total Release Ci N/A*
N/A*
N/A*
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
- 4th
';..* ErrQt.
l 'Qqatfer;, <
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
. 'i <';
N/A*
N/A*
N/A*
N/A*
durinq period Percent of applicable limit N/A*
N/A*
N/A*
N/A*
D. Gross Alpha Radioactivitv Total release Ci N/A*
N/A*
N/A*
N/A*
N/A*
Average diluted concentration
µCi/ml N/A*
N/A*
N/A*
N/A*
durinq period E. Volume of Waste Released Liters N/A*
N/A*
N/A*
N/A*
(prior to dilution)
F. Volume of Dilution Water Liters N/A*
N/A*
N/A*
N/A*
Used Durina Period N/A*= Not Applicable There are no liquid effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 8 of 15
I*
Table 2A MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2017 Liquid Effluents - Batch Mode
- *N11clides f eleasecl,,'.~t>* ?,'\\Phi~,l~ t:;*.. 1st'* **,H'2nd
'**.*,. ;'.f;;3rd, :<
Quarter
. :::}'{ >
Quarter Quarter Strontium-89 Ci N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
lodine-131 Ci N/A*
N/A*
N/A*
Cobalt-58 Ci N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
lron-59 Ci N/A*
N/A*
N/A*
Zinc-65 Ci N/A*
N/A*
N/A*
Man~anese-54 Ci N/A*
N/A*
N/A*
Chromium-51 Ci N/A*
N/A*
N/A*
Zirconium-Niobium-95 Ci N/A*
N/A*
N/A*
Molybdenum-99 Ci N/A*
N/A*
N/A*
Technetium-99m Ci N/A*
N/A*
N/A*
Barium-Lathanium-140 Ci N/A*
N/A*
N/A*
Cerium-141 Ci N/A*
N/A*
N/A*
Others-lron-55 Ci N/A*
N/A*
N/A*
Antimony-125 Ci N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
Total for period (above)
Ci N/A*
N/A*
N/A*
Dissolved and Entrained Ci N/A*
N/A*
N/A*
Gasses Tritium Ci N/A*
N/A*
N/A*
Gross Alpha Ci N/A*
N/A*
N/A*
N/A*= Not Applicable
}/"4th:
.*.Totals.**
. Quart~r*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
There are no liquid effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 9 of 15
Table 28 MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2017 Liquid Effluents - Continuous Mode Strontium-89 Strontium-90 Cesium-134 Cesium-137 lodine-131 Cobalt-58 Cobalt-60 lron-59 Zinc-65 ManQanese-54 Chromium-51 Zirconium-Niobium-95 Molybdenum-99 Technetium-99m Bariu m-Lathaniu m-140 Cerium-141 Others-lron-55 Antimony-125 Unidentified Total for period (above)
Dissolved and Entrained Gasses Tritium Gross Alpha N/A*= Not Applicable Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Ci N/A*
N/A*
N/A*
N/A*
N/A*
There are no liquid effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2017 Annual RER Report Page 10 of 15
Table 3 MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report First Half 2017 Low Level Waste Shipments Resins,:Filters*.and.Evaporat9r.B0ttoms
'/
0 VQlume...
Waste Class Solidifying Agent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
Dry Active,Waste.,:"
J(olume Waste Class Solidifying Agent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
lrradiiited Compqn~nts Volume Waste Class Solidifvina Aaent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
Other Waste. *
'{gl~me
- .. vi.
Waste Class Solidifying Agent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
MY 2017 Annual RER Report Curies Shipped*
/'
Curies 0
0 0
0 J
Curies Shipped Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Curies Sflipped
'/;1>*,
Curies 0
0 0
0 Page 11 of 15
Table 3A MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report Second Half 2017 Low Level Waste Shipments Resins,}ilters a~d E'1'aporatQr Bottom$*** *U:
-~,~.
Waste Class Solidifvina Aaent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
Dry Active Waste...
Volume Waste Class Solidifvina Aaent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
lrrad.iated Components * ** <f:,
VcHum~f Waste Class Solidifving Agent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
Other Waste Volume Waste Class Solidifying Agent ft3 ma A
0 0
B 0
0 C
0 0
All 0
0 Major radionuclides for above data:
MY 2017 Annual RER Report Curies 0
0 0
0
- . Curies.Shipped Curies 0
0 0
0 Curies Sl,Jippecf Curies 0
0 0
0 Curies Shipped Curies 0
0 0
0 Page 12 of 15
Appendix A Radiation Dose Assessment There were no gaseous or liquid effluent releases in 2017. Therefore, an assessment of radiation doses to the most likely exposed member(s) of the public to show compliance with 40CFR190 or 10CFR72.104 from effluents was not required.
MY 2017 Annual RER Report Page 13 of 15
Appendix B Unplanned Releases There were no unplanned releases of radioactive materials from the site in 2017.
MY 2017 Annual RER Report Page 14 of 15
AppendixC Off-site Dose Calculation Manual Changes There were no changes to the Off-site Dose Calculation Manual in 2017.
MY 2017 Annual RER Report Page 15 of 15