ML18128A004
| ML18128A004 | |
| Person / Time | |
|---|---|
| Site: | PROJ0728, 99902041 |
| Issue date: | 05/08/2018 |
| From: | Rowley J NRC/NRR/DLP/PLPB |
| To: | Peters G Framatome |
| Rowley J, NRR/DLP, 415-4053 | |
| Shared Package | |
| ML18128A002 Pkg. | List: |
| References | |
| ANP-10333P, Rev 0 | |
| Download: ML18128A004 (2) | |
Text
RESOLUTION OF COMMENTS BY THE OFFICE OF NUCLEAR REACTOR REGULATION ON DRAFT SAFETY EVALUATION FOR TOPICAL REPORT ANP-10333P, REVISION 0, AURORA-B: AN EVALUATION MODEL FOR BOILING WATER REACTORS; APPLICATION TO CONTROL ROD DROP ACCIDENT (CRDA)
FRAMATOME, INC.
PROJECT NO. 728/DOCKET NO. 99902041 This Attachment provides the U.S. Nuclear Regulatory Commission (NRC) staffs review and disposition of the comments made by Framatome Inc. (formerly AREVA Inc.) on the draft safety evaluation for Topical Report ANP-10333P, Revision 0, AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Control Rod Drop Accident (CRDA).
Page No. Line(s) No. Proposed Change and Reason NRC Response 2 20-25, 27- Proprietary markups have been NRC staff agrees with 28, 33-34, added to reflect AURORA-B AOO SE suggested editorial 36, 42-44, and are highlighted in yellow. changes. Final SE 47-48 modified accordingly.
2-5 Section 2.0 The Limitations and Conditions listed The Limitations and from the AURORA-B TR SE Conditions were updated (ANP-10300P, Revision 0) are not to reflect those from the consistent with the final SE ANP-10300P final SE.
Limitations and Conditions. Listed Limitations and Conditions should be updated to reflect final Limitations and Conditions from the AURORA-B TR SE.
3 11-15, 18, Proprietary markups have been NRC staff agrees with 20-21, 24- added to reflect AURORA-B AOO SE suggested editorial 26, 33- and are highlighted in yellow. changes. Final SE 37,42-44 modified accordingly.
4 11,13 Proprietary markups have been NRC staff agrees with added to reflect AURORA-B AOO SE suggested editorial and are highlighted in yellow. changes. Final SE modified accordingly.
5 1-3, 9-11 Proprietary markups have been NRC staff agrees with added to reflect AURORA-B AOO SE suggested editorial and are highlighted in yellow. changes. Final SE modified accordingly.
22 1 Replace [ ''' '''''''''' ''''''''] with NRC staff agrees with
[ ''' ''''''''' ''''''''''' '''''''''' suggested editorial
'''''''''''''''' '' ''''''''] for clarification. change. Final SE modified accordingly.
22 48 Replace ['''''''''''''] with ['''''''] for NRC staff agrees with clarification. suggested editorial change. Final SE modified accordingly.
Attachment
Page No. Line(s) No. Proposed Change and Reason NRC Response 37 44 Replace different with reduced for NRC staff agrees with consistency. suggested editorial change. Final SE modified accordingly.
38-40 Section 5.0 The Limitations and Conditions listed The Limitations and from the AURORA-B TR SE Conditions were updated (ANP-10300P Revision 0) are not to reflect those from the consistent with the final SE ANP-10300P final SE.
Limitations and Conditions. Listed Limitations and Conditions should be updated to reflect final Limitations and Conditions from the AURORA-B TR SE.
39 7-9, 18-20 Proprietary markups have been NRC staff agrees with added to reflect AURORA-B AOO SE suggested editorial and are highlighted in yellow. changes. Final SE modified accordingly.
40 17-18 Proprietary markups have been NRC staff agrees with added to reflect AURORA-B AOO SE suggested editorial and are highlighted in yellow. changes. Final SE modified accordingly.
41 28 Replace modification with NRC staff agrees with reduction for consistency. suggested editorial change. Final SE modified accordingly.