Drawing 8770-G-078, Rev. 9, Flow Diagram Symbols. Sheet 100
ML18127B296
Person / Time
Site: Saint Lucie 
(DPR-067)
Issue date: 06/26/2001
From:
Ebasco Services
To:
Florida Power & Light Co, Office of Nuclear Reactor Regulation
References
8770-G-078, Rev 9
Download: ML18127B296 (1)


Text

REh/ISIONS 8770-G-078 SH 100 NO DATE BY CH PDB GM APPROVED DESCRIPTION 8/25/97 SHM EQUIPMENT VENTURI TYPE FLOW ELEMENT STRAP ON ACCOUSTICAL FLOW SENSOR SURFACE IYPE GAS VENT (V)

STEAM TRAP (T) OR TEMPERATURE ELEMENT 5

Y TYPE STRAINER

~~8}

DUPLEX STRAINER SIGHT LEVEL GLASS FILTER REGULATOR

~~PC

}

SPHERICAL TfPE PULSATION DAMPER C

CONDENSATE POT FLAME ARRESTOR DIAPHRAG'J CONNECTION reer)err cc r ri

~i}

RUPTURE DISK RELIEF TO SYSTEM a

QUICK CONNECT COUPLING FOR PRIMARY SYSTEMS SPECTACLE BLIND NORMALLY CLOSED NC THERMAL SLEEVE OPEN DRAIN FUNNEL Y

COOLIiVG FINS STATION NUh(BER Hs 15 XX FLORIDA PQ)VER k LIGHT COMPANY APPROVAL DATE:

scaLE:

NONE 8770-G-078 MECH DR.

P 6ERCERON 6

MOERS SHEET 100 9

~R96 0:

REDRAWN 7/30/98 GM Hs GMcK

~DR e

07:

ADD; (H5) VALVE AND TEXT

~V/

~RO 0

7 ADD. (02)

LICENSE RENEWAL FLAGS (EB) GENERAL NOTES.

CONDENSER ATMOSPHERIC TANK TANK PRESSURIZER VESS L

VANE AXIAL FAN SINGLE FLOW TURBINE STRAIGHT TUBE HEAT EXCHANGER UTUBE HEAT EXCHANGER CENTRIFUGAL PUMP CANNED CENTRIFUCAL PUMP VACUUM PUMP DISPLACEMENT PUMP POSITIVE SUMP PUMP VERTICAL PUMP COMPRESSOR CENTRIFUGAL FAN OR COh(PRESSOR GENERAL NOTES:

1.

DENOTES PRHSURE BOUND'QIES (PROCESS PIPING / TUBING I CCMPCNcVTS)

FOR STSTEMS WITHIN THE SCOPE QF LICFNSE RENEWAL STEAM GENERATOR 2.

DENOTES iN PROCESS PIPING / TUBING / CDMPONENTS Y/ITHIN THE SCOPE OF LICENSE RENEWAL

3. OUALIIY CROUP A, 8 OR C BOUNDARIES WITH UNTAGGEO Class D CCMPONENTS Spa(L BE CC!/SICERcD AS A LICENSE RENEA'AL BOUNDARY ALDHQUQi NCT ICBhrr(IFD Y/ITH A LICEVSE RENEWAL BOUNDARY FLAG.

REFERENCE DRAWINGS MIXER VALVE AND SPECIALTIES LIST PIPING LINE LIST VALVE OPcQATIONAL NUMBER INDEX INSTRUMENT INSTALL'TIQN DETAILS 8770-A-051 8770-8-052 8770-8-053 8770-8-231 MANWAY OR ACCESS HATCH BOTTOll LOADED FILTER NOTE:

M QUICK DISCCNVcC 5 ARc OoTICVAL I "Ms IVHICH MAY e.

INSTALLED FQR CCNWENIENCE, BIJT ARE NOT REC)JIRED FOR OEcrCN FLiNCTICNS TANK STRAINER NOTE:

THIS DRAWING IS MADE Fi(OM REV 6

QF Opaw!NG 8770-0-078 SH 100 UNDER DRAIN DISTRIBUTOR REVISIOi'I OF THIS DRAY/iiVG MAY REQUIRE UPDATE OF THE FOLLOWING DOCUIXENTS:

1.

FSAR FIGURE 1.2 20 2.

FSAR FIGURE 1.2 26 3.

FSAR FIGURE 1.2 27 4.

FSAR FIGURE 1.2-2B 5.

FSAR FIGURE 1.2 29 FIRE HYDRANT FLORIDA POWER

& LIGHT COMPANY ST LUCIE PLANT 1976 890 MWe INSTALLATION UiNIT 1

FLOW DIAGRA(!

SYMBOLS FIRE HOSE STATION Y

ANALYSI5 POSITION INSTRUMENTATION O

LOCALLY MOUNTED INSTRUMENT CONTROL ROOM MOUNTED INSTRUMENTS HOT SHUTDOWN PANEL MOUNTED INSTRUMENTS 6

LOCAL PANEL OR RACK MOUNTED INSTRUMENTS XXXX LOCATIO)V OF O

PANEL OR RACK SUMMING ELEMENT SQUARE ROOT EXTRACTOR TYPICAL INSTRUMENTATION ARRANGEMENT GAUCE OR TRANSMITTER CAUGE OR TRANSMITTER ROOT VALVE PRESSURE SENSING LINES CONNECTED TO TAPS ON ORIFICE FLAVGES ROOT VALVE ALARMS REACTOR TRIP WITH ALARM ANNUNCIATED IN CONTROL ROOM O

H H

HIGH REACTOR TRIP AND HIGH A(AQM T A XXX PANEL OR RACK NO L

L LOW REACTOR TRIP AVD LQY/ ALARM ALARM ANiNUNCIATED liV IN CONTROL ROO!J HH VERY HIC)-I H

HIGH A

XXX PANEL QR RACK NO L

LCW LL VERY LOW LOCAL ALARM VERY HIGH HIGH HH LOW VErÃr LCW LL SWITCH POSITIONS 2(

ABBREVIATIONS MANUAL NOR!JAL OPEN OFF ON OVERRIDE PUSHBUTTON RESET M

N 0

OFF ON OR PB Rs A

AUTO 8

BOTH BP BYPASS C

CLOSE I

ISOLATE LC LOCKED CLOSED (KEY)

LO LOCKED OPEN (KEY)

LR LOCKED REMOTE INSTRUMENT AND SWITCH IDENTIFICATION FUNCTION (TABLE I)

FF X(YY CHANNEL NUh(BER SYsirM NQ ZZ CONTROL SWITCH Cs XXX CWD NUMBER Y

CTVD SWITCH NUMBER CHA'tNEL SUFFIX THE CWD NUMBER REFERS TO THE SHEET NUMBER OF DRAWING 8770-8-327 SYSTEM NUMBERS ARE SHOY/N THE PIPING LINE LIST, DRAWING 8770-6-052 MEASUREMENT CHANNELS ARE SUFFIXED AS FOLLOWS:

I SAFETY CHANNEL NUMBERS ARE SUFFIXED BY A, 8, C,

AND D

ETC 2 SIMILAR MEASUREMENT CHANNELS ARE SUFFIXED BY X, Y, 2, ETC 3

H AND C

WHEN USED IN INSTRUMENTATIQN CHANNEL SUFFIXES DENOTE HOT AND COLD INSTRUh(ENT IDENTIFICATION LETTERS DENOTE CHANNEL FUNCTION, NQT SPECIFIC EQUIPMENT INSTRU!/ENTATION IDENTIFICATION LETTERS FIRST LETTER SUCCEEDING LETTERS MEASURED OR INITIATING VARIABLE READ OUT OR FUNCTIOiV A

AIR C

)

CQNDUCTIVIIY ELECTRICAL DI DENSITY CONTROL DIFFFRENTIAL ELEMENT F

FLOW RATE GLASS H

HAND MANUALLY INITIATED INDICATOR I

CURRENT ELECTRICAL J

POWER K

TIME OR TIME SCHEDULE L

LEVEL M

MOISTURE OR HUMIDITY VIBRATION P

PRESSURE LIGHT 0

QUANTIIY NUh(BER R

RADIATION 5

SPEED OR SELECTOR T

TEh(PERATURE INTECRATOR OR TOTALIZER RECORDER SWITCH TRAiVSMITTER OR TRANSDUCER VALVE W

WEIGHT WELL TEST POINT OR MISC POWER SUPPLY CONVERTOR SG SIB SIL V

BUILDING AND EQUIPMENT BOUNDARY LINES R ~~ ~

% ~

CONTAINMENT BOUNDARY CONTAINMENT PENETRATION (PIPE)

~ ~~ ~~

X

~~ ~~

CONTAINMENT PENETRATION (ELECT)

~ ~~ ~~ ~~ ~~ ~~

BUILDING OUTLINE BlACK BOX PIPE AND TUBING LINE TYPES MAIN PROCESS LINE SECONDARY PROCESS LINE INSTRUMENT LINE CAPILIARY TUBINC PNEUMATIC SIGNAL/ACTUATION TUBING ELECTRICAL LINE TYPES ELECTRICAL SIGNAL LINE RADIATION SIGNAL HEAT TRACED PIPE OR TUBING

~

~

~

~

(HEAT TRACING FUNCTICNAL)

HEAT TRACED PIPE OR TUBING (HEAT TRACING ABANDONED)

MISCELLANEOUS LINE TYPES AIR SCicEEN REFERENCE TO CONNECTING DRAWINGS TO CR FROM EQUI?MENT DRAWING NUMBER SYS A68REV COORD NCR(ML CCNTll/UATICN F'0 INsiRUMENT AiR CCNTLNUA iCN Fl(G ON AIR SOURCE DR////ING TO EQUIPMENT DRAWING NUMBER COORD INSTR)J!/ENT ALR CQ!JTINL'.-'ZION FLeC AT POINT OF USE FRCM Dl/G NO (COQRD)

VENDOR CONNECTION NUMBEic ELECTRICAL SIGiVAL ARRANGEMENT PROCESS DATA POINTS eJUNCTION IDENTIFICATION NUMBERS FOUND ON THE RCS, CVCS, SIS.

FPS, SS, A'/D WMS FI.OW DIAGRAMS XX Cee55[iii PROCESS FLOW DATA AT NL!h(BERED LOCATIONS ARE DEFINED IN TiiE SAFEIY ANALYSIS REPORT C

COMPUTER DATA INPUT PIPE AND TUBING ARRANGEMENT JUNCTION SAFETY CLASS AND SEISMIC CATEGORY a

X A. 8, C,

D =

SAFEIY ClASS (QUALIIY CROUP)

(REF'r TABLE 3.2 1 CF FcSAQ)

I = SE!SMIC CATEGORY CROSSING LICENSE RENEWAL CATEGORY LR = LICENSE RENEWAL SCOPE QLR

~CONTINUATION (NOTE 2)

BOUNDARY (NOTE I)~

ABBREVIATIONS MISCELI"NEGUS SIGNAL CIS CONTAINMENT ISOLATION CSAS CONTAINMENT SPRAY ACTUATION MS IS MAIN STEAM ISCLATION RAS RECIRCUlATION ACTUATION SIAS SAFETY INJECTION ACTUATION AWPAUTOMATIC CEA WITHDRAWL PROHIBIT BACKUP HEATER BREAKERS BACKUP HEATER CCl(TROL CCNTROL ELEMENT DRIVE SYSTEM DRAIN GAS AVALYZER HIGH PRccsURIZrR PRcccURE RELIEF VALVE TRIP HYDROGEN LOW PRESSURIZER PRESSURE RELIEF VALVE TRIP LOCAL SAMPLE LOCAL SAMPLE SINK NITROGEN NITROGEN SUPPLY PROPORTIONAL HEATER CONTROL PROGRAMED LEVEL SETPOINT (RRS)

REACTOR PROTECTIVE SYSTEM REVERSE ROTATION REACTOR REGULATLVG SYSTEM PRCPCRTIONAL HEATER SCR COi(TROI.LERS STEAM GENERATOR SAFETY INJECTION BLOCK SAFElY INJECTION LOGIC VENT TO ATMOSPHERE BHB-BHC CEDS-DR GA HPRT EQUIPMENT BAMT BORIC ACID MAKEUP TANK (CVCS)

BAT BORIC ACID BATCHING TAl/K (CVCS)

CAT CHE!/ICAL ADDITION TANK (CVCS)

EDT EQUIPMENT DRAIN TANK (WMS)

FT FLASH TANK HT HOLD-UP TAi'IK (WMS)

QT QUENCH TANK (RCS)

RAT RESIN ADDITION TANK (Wl/S)

RDT REACTOR DRAIN TANK (WMS)

RWT REFUELING

')YATER TANK SIT SAFETY INJECTION TANK (SIS)

SRT SPENT RESIN TANK (Y/Ms)

VCT VOLUME CONTROL TANK (CVCS)

H2 LPRT Ls Lss N2 N/5 PHC PLS Rps-RR RRS-SCR EXTFNSION STEM POST INDICATOR AIR 8(

MOTOR OPERATED VALVES (EXCEPT NON-PROPORTIONAL, REMOTELY HAND CONTROLLED VALVES) lOCI QR FFF-XX-YYY~ VALVE NO (SEE 8770-A-051)

FUNCTION (TABLE I)

SYSTEM NUMBERS ARE SHOV/N THE PIPING LINE LIST, DRAWING 8770-8-052 MANUALLY OPERATED VALVES (INCLUDES NON-PROPORTIONaM REM(OTELY HAND CONTROLLED VALVES)

OR

~VALVE NO (SEE 8770-A-051)

FUNCTION (TABLE I)

SYSTEM NUMBERS ARE SHOWN THE PIPING LINE LIST, DRAWING 8770-8-052 VALVE DESCRIPTION VALVE INSTRUMENTATIOi'I ACCESSORIES VALVE HARDWARE ~

VALVE OPERATOR

~

VALVE LOCKING MODE VALVE FAILURE MODE FF LL VALVE BODY TYPE VALVE MODE DESCRIPTION NOR((ALLY OPEN

~LO/C LOCKED OPEN (AT CONTROL ROOM)

~LC/C LOCKED CLOSED (AT CONTROL ROOM)

LO LOCKED OPEN (AT VALVE)

NORMALLY CLOSED LC NEXT PORT TO CLOSE INDICATED BY A DOT IN THE PORT LOCKED CLOSED (AT VALI/E)

FAIL OPEN FC FAIL CLOSED

~ }

BUTTEPFLY VALVE (VQRh(ALLY CLOSED)

Fai Faih AS iS PIPING LINE DESIGN~TIOV SEisMIC CATEGORY rir i

) ~

/i

..r r-;> 4ee.

cere r

e ric r rrc LINE LIST, DRAWING 8770-8-052 VALVE BODY TYPES C'TF GLOBE BALL NEEDLE

~

Wh }

BUT%RELY DIAPHRAGM LIFT CHECK STOP CHECK

~r EXCESS FLO(V CHECK SPRING CHFCK FLCAT CHLCK FLOAT VENT ANGLE A

6 F cMETY AVD RELI F 3-WAY 4-WAY plLQT vaLvE VALVE ACCESSORiES EXTENSION HANDWHEEL (ON DIAPHRAGM OPEP "CR) 5TEht LEAKQFF BELLCWS SEAL P'VDWHEEL (CN DIAPHP'GM OPERATOR)

FLOW INDICATING NE rill'APPED cT M VALVE OPERATORS SELF ACTUATED PRESSURE REGULATING SOLENOID DIAPHRAGM (PNEUhlATIC)

P ELECTRIC MOTOR PISTON (HYDRAULIC)

PISTON (PNEUMATIC)

PIPE AND EQUIPMENT ACCESSORIES ANNUBAR IYPE FLOW ELEMENT FLOYt MEASURING ORIFICE RESTRICTION ORIFICE 50 c

e r

r r

l} FLANGED ScOOL PIECE FOR STARTUP SUCTION STRAINER INLINE SÃi(AINER BASKET STRAINER SIGHT FLOW GLASS JET PUMp FILTER Ps 5 } SUCTION STABILIZER STRAP ON OR IMMERSION HEATER (ELECTRICAL) ACCUMULATOR FL))NGED CONNECTION re ei i r RUPTURE DISK RELIEF TO ATMOSPHERE QUICK CONNECT COUPLING FOR Sr.CCNOARY SYSTEMS PLUG OR C/O'PED STUB 6LIND FLANGE SPECTACLE BLIND NORMALLY OPEN NO SPRAY NOZZLE HEADER ScRAY NOZZLE LOOP SEAL STRAICHTEN ING VA'tES VALVE W/VALVE BQX AND TEE WRENCH OPERATOR EDUCTOR WFLOED CAP}}