ML18127B290
| ML18127B290 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 06/14/2001 |
| From: | Ebasco Services |
| To: | Florida Power & Light Co, Office of Nuclear Reactor Regulation |
| References | |
| 8770-B-327, Rev 61 | |
| Download: ML18127B290 (1) | |
Text
SHEET NO REV NO SHEET REV NO NO SHEET NO REV NO 739 740 741 742 743 744 745 746 747 749 750 751 752 753 754 755 756 768 769 770 771 772 773 774 775 776 781 782 783 784 785 786 787 788 789 790 791 792 AUX STM EXH STM COND & AIR VAC REVERSE CURRENT VALVES SH 2 REVERSE CURRENT VALVES SH 1
CONDENSER HOTWELL LEVEL CONTROL AUX PRIMING JET CONTROL CONDENSATE TRANSFER PUMP & COND STOR TK N2 BLANKET SJAE STM & FEED PUMP SUCT HDR PRESS, COND STM TK & HTL LVL COND PUMP PIT SUMP PUMPS 1A & 1B CONDENSER SAMPLING PUMPS 1Al, 1A2, 1B1, 1B2 EXTRACTION STEAM TO BORIC ACID CONCENTRATORS TURBINE BYPASS TO CONDENSER VALVE PCV-8801 STM DUMP TO CONDENSER VALVES PCV8802 & PCV8803 STM DUMP TO CONDENSER VALVES PCV-8804 & PCV-8805 AUX STEAM UNE ISOLATION VALVES TCV-085
. AUX STEAM LINE ISOLATION VALVES PCY16-1, 6, & 7 AUX STEAM UNE ISOLATION VALVE MV-08-12 VACUUM BREAKER VALVE MV10 1A VACUUM BREAKER VALVE MV10-1B AUX BOILER OFFSERVICE WARMUP STM VALVE SE 16 1 RESERVED GLAND STEAM CONDENSER 1A (AIR EXHAUST)
GCE1 GLAND STEAM CONDENSER 1B (AIR EXHAUST)
GCE2 HP GLAND SUPPLY BYPASS YALVE MV08878 SPILLOVER BYPASS VALYE MV08814 HP GLAND SUPPLY SHUTOFF VALVE MV08877 SPILLOVER SHUTOFF VALVE MV08813 GLAND STEAM CONDENSER TRANSFER PUMP SECONDARY SIDE WET LAYUP SURGE TANK LEVEL SECONDARY SIDE WET LAYUP PUMPS 1A & 1B TURBINE DRAIN VALVES DV-1 TO DV-9 TURBINEGEN SUPERV INSTR OUTPUT WIRING TURBINEGEN INSTR BRG g1,
- ECC, DE (GOV), CE TURBINEGEN SUPERV BRG g2 & 3 TURBINEGEN INSTR BRG g5 & KEY t5 TURBINEGEN INSTR BRG P6
& DE (GEN)
TURBINE-GEN SUPERV BRG g7 & TACH TURBINEGEN INSTR THRUST BEARINGS & BRG P4-TURBINEGEN INSTR.BRG P 8 & 9 TURBINE DIFF EXP & ROTOR ECCENTRICITY TURBINE GENERATOR BEARING VIBRATION
- ROTOR, YALYE, CASING & SPEED MONITORING 793 794 795 796 797 798 799 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 833 834 835 837 REV DATE BY VOID LUBE WATER SUPPLY STRAINERS CIRC INTAKE & COOL WTR ANNUNCIATOR E
SH 1 RTGB-102 CIRC INTAKE & COOL WTR ANNUNCIATOR E
SH 2 RTGB-102 842 841 VOID VOID VOID VOID REACTOR AUX BUILDING FIRE PROTECTlON SPRINKLER SYS PRIMARY WATER ISOLATION VALVE MV-15-1 PRIMARY MAKEUP WATER PUMP 1A PRIMARY MAKEUP WATER PUMP 1B RRE WATER PUMP 1A RRE WATER PUMP 1B DOMESTIC WATER PUMP 1A & 1B TURBINE LUBE OIL, HYD SEAL OIL & HTR DRAIN PROTECTION CABLE SPREADING ROOM FIRE PROTECTlON SYSTEM 855 856 857 858 859 SERVICE BLD'G & BACKFIT W/HOUSE FIRE PROTECTION SYS TRANSFORMER RRE PROTECTION SYSTEM SH 1
TRANSFORMER RRE PROTECTION SYSTEM SH 2 GROUND INTERCONNECTIONS FOR TEMP RECORDER TR-22 30 GEN MAIN & AUX TRANSF ANNUNOATOR C
SH 1
RTGB-101 GEN MAIN & AUX TRANSF ANNUNCIATOR C
SH 2 RTGB101 MAIN TRANSFORMER 1A MAIN TRANSFORMER 1B GENERATOR MAIN LEADS COOLER 1A & 1B HYDROGEN COOLING SYSTEM HYDROGEN COOLING SYSTEM ANNUNCIATORS AIR SIDE SEAL OIL PUMP M3 HYDROGEN SIDE SEAL OIL PUMP M4 AIR SIDE SEAL OIL BACK-UP PUMP M5 LOAD FREQUENCY CONTROL EXCITATION SYSTEM OIL VAPOR EXTRACTOR (GENERATOR)OEG VOLTAGE REGULATOR AC REGULATOR ADJUSTER DC REGULATOR ADJUSTER GENERATOR EXCITATION SUPPLY BREAKER MAIN TRANSFORMER DIFF RELAYING GENERATOR MAIN TRANSFORMER DIFF RELAYING GENERATOR CURRENT RELAYING GENERATOR RELAYING & METERING 861 862 863 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 EBASCO SERVICES INCORPORATED NEW YORK FLORIDA POWER Bc LIGHT COMPANY ST LUCIE PLANTEXTENSIONUNIT 1
CONTROL WIRING DIAGRAM APPROVED R
C HAEKLER V.O.
M.M.
INDEX CONTROLLED START TEMPERATURE RECORDER GENERATOR TURBINE OIL DRAIN BEARING TEMPERATURES TURBINE GLAND STEAM, BRG OIL & HYD FL PRESS
& TEMP TURBINE STEAM PRESSURE GEN TURBINE METAL BEARING TEMPERTAURES TURBINE GEN SUPERV INSTR MIMIC PNL INPUT CONNECTIONS RTGB-101 125V DC, 120V AC, & 45V DC DISTRIBUTION TURB & GEN COOL ANNUNCIATOR D
SH 1
RTGB-101 TURB & GEN COOL ANNUNCIATOR "D" SH 2 RTGB-101 CIRCULATlNG WATER TRAVELUNG SCREENS lAl, 1A2, 1Bl, & 1B2 DIFF PRESS INTAKE CANAL, CIRC & COOUNG WATER T/C'S CIRC WTR CONDENSER 1A1 DISCHARGE VALVE MV21-5A1 CIRC WTR CONDENSER 1B1 DISCHARGE VALVE MV21-581 CIRC WTR CONDENSER 1A2 DISCHARGE VALVE MY-21-5A2 ORC WTR CONDENSER 1B2 DISCHARGE VALVE MV-21582 ORCULATING WATER PUMP lA1 CIRCULATING WTR PUMP lA1 DISCHARGE VALVE MV-21-1Al CIRCULATING WATER PUMP 181 CIRC WTR PUMP 1B1 DISCHARGE VALVE MV21 1B1 CIRCULATING WATER PUMP 1A2 CIRC WTR PUMP 1A2 DISCHARGE VALVE MV-21-1A2 CIRCULATING WATER PUMP 182 CIRC WTR PUMP 1B2 DISCHARGE VALVE MV-21-1B2 EMERG COOLING WATER AIR SYSTEM SOLENOIDS SCREEN WASH PUMP 1A SCREEN WASH PUMP 18 TRAYEUNG SCREEN lA1 BAY gl TRAVELING SCREEN lA2 BAY g2 TRAVEUNG SCREEN 181 BAY g3 TRAVELING SCREEN 1B2 BAY //4 TURBIN C 0 ING TURBINE COOLING WATER PUMP lA TURBINE COOUNG WATER PUMP 1B CWP & TCWP MOTOR BRG TEMP TCW HX CATHODIC PROTECTlON NITROGEN COMPRESSORS 1A & 1B INTAKE COOL WTR DISCH HDR PRESS PUMP 1A & PUMP 1B INTAKE COOLING WATER PUMP 1A INTAKE COOUNG WATER PUMP 1B INTAKE COOUNG WATER PUMP 1C INTAKE COOL WTR NON-EMER HDR A ISOL VALYE MV21 3 INTAKE COOL WTR NON-EMER HDR B ISOL VALVE MV-212 VOID 61 60 6/9/94 59 7/26/93 58 12/4/92 REV DATE TW MZ RJF AII DPT CSO RLM RFR RSC DIV-I&C DR:
APPROVED JPP AK BY APPROVED 838 839 845 847 848 849 850 851 852 853 854 860 880 881 8770-8-327 SHEET 6 FILE: USE00636 DWG