ML18127B267
ML18127B267 | |
Person / Time | |
---|---|
Site: | Saint Lucie |
Issue date: | 10/13/1977 |
From: | Florida Power & Light Co |
To: | Office of Nuclear Reactor Regulation |
References | |
8770-1288, Rev 5 | |
Download: ML18127B267 (1) | |
Text
T 6 BILL OF MATERIALS DUANTITIES ARE FOR 14 12 17 SEE NOTE 7 26 23 SEE NOTE 5 16 19 SEE NOTE 6 GROUP Ro.
8 DUANTRY ITEM NAME PIECE No MATERIAL REMARKS 4321 Na.
B C D NUCLEAR INSTRUMENTATION AND E-19367-411-021-1 SEE SPEC: 19367-ICE-501 REACTOR PROTECTIVE SYSTEM I 2 RPS BIN ASSEMBLY IN CABINET A E-19367-411-024-2 SEE SPEC: 19367-ICE-501 I 3 RPS BIH ASSEMBLY IN CABINET 8 E-19J67-411-024-3 SEE SPEC: 19367-ICE-501 4 RPS BIN ASSEMBLY IN CABINET C E-19367-411-024-4 5EE SPEC: 19367-ICE-501 0000 00000 I
19367-ICE-501 I 5 BIN ASSEMBLY IN CABINET D E-19367-411-024-5 SEE SPEC:
R.P.S. POWER 000000 0000000 RPS E-19367-411-376-1 19367-ICE-501 4 TRIP UNIT INTERCONNECTION MODULE ASSY SEE SPEC:
SUPPLY ASSY TRIP STATUS PANEL 000000 00000 6
8-3/4 0000 N.l. 6( R P 5 CABINET ASSEMBLY 0-19367-411-022-1 SEE SPEC: 19367-ICE-501 a 1 taRY LOGIC ASSEMBLY E-19367-411 I SEE SPEC: 19367-ICE-501 LOCATED IN REAR(BWB) LOCATED IN REAR(CWB) LOCATED IN REAR(DWB) WIDE RANGE N.l./FDWER RANGE N.l. REF DWG: 877D-IJ644, LOCATED IN REAR(AWB) 4 9 04MMA METRICS POWER SUPPLY DRAWER -13645 A (Aw1 ) (Bw1) (CW I ) (Dwl)
I A 4 10 TRlp INHIBIT SWITCH PANEL E-19367-411-025-1 SEE SPEC: 19367-ICE- 501 TRIP UNIT BIN ASSEMBLY D-19367-411-366-1 SEE SPEC: 19367-tCE-501 I 12 TRIP STATUS PANEL E-19367-4(I-GJJ-I
-6 I REACTOR PROTECTIVE SYSTEM I 13 COMPARATOR/AVERACER DRAWER E-19367-411-021-13 GULF ELECTRONIC S(S.
WIDE RANGE N.l./POWER RANGE N.l. 4 14 R P 5 POWER SUPPLY E-19367-411-021-H f' I WIDE RANGE N I /POWER RANGE N I WIDE RANGE N.l./POWER RANGE N.l. WIDE RANGE N.l./POWER RANGE N.l.
3.4 POWER SUPPLY DRAWER POWER SUPPLY DRAWER 15 POWER SUPPLY DRAWER POWER SUPPLY DRAWER WIDE RANGE LOCARITHMIC/POWER RANGE REF DWG: 8110-13622, GAMMA METRICS 4 16 (AFETY DRAWER 13623. - 13624 I 17 IDENTIFICATION PLATE E-19367-411-G21-17 SEE NOTE 2 (AW2/AW3-PS) (BW2/BW3-PS) (CW2/CW3-PS) (DW2/DW3-PS) 4 18 CORE PROTECTION CALCULA110N No.l E-19367-411-021-16 SEE SPEC: 19367-ICE-3015 2 19 BLANK FRONT PANEL E-19367-411-021-19 4 20 R.P.S. CAUBRATIDN 6( INDICATION PANEL E-19367-411-40t-t SEE SPEC: 19367-ICE-501 I
4 21 TRIP TEST CABLE PANEL 0-19367-411-029-1 SEE SPEC: 19367-ICE-JOI WIDE RANGE LOGARITHMIC/POWER RANGE WIDE RANGE LOGARITHMIC/POWER RANGE WIDE RANGE LOGARITHMIC/PQVIER RANGE WIDE RANGE LOGARITHMIC/POWER RANGE 8 22 SWITCH E-19367-411-021-22 SAFETY DRAWER SAFETY DRAWER SAFETY DRAWER SAFETY DRAWER 8-3/4 N.I. CHANNELS 4 8( 8 8 23 IDENTIFICATION PLATE E-19367-411-021-23 N.I. CHANNELS I 8( 5 N.l. CHANNELS 2 ec 6 N.l. CHANNELS 3 8( 7 12 24 INDICATDR UGHT 6-19367-411-021-24 DIALCD 186-9730-5275-602 4 25 BLANK FRONT PANEL E-19367-411-021-25 I 26 SPEAKER E-19367-411-021-26 GULF ELECTRONIC SYS.
(AW2/AW3) (BW2/BW3) (CW2/CW3) (DW2/DW3)
I 27 TRAC-2 E-19367-411-022-14 22 22 I 28 POWER RATIO CALCULATOR E-19367-411-021-26 SEE SPEC; 19367-ICE-304 4 29 CDRE PRDTEC,IDN CALCULATOR No.2 E-19367-411-021-29 SEE SPEC: 19367-(CE-JDIJ R.P.S. CALIBRATION Bc 4 3D ISOLATION AcSSEMBLY E"19367-411-064-30 SEE SPEC: 19367-ICE-3029 R.P.S. CALIBRATION Bc R.P.S. CALIBRATION 8( R.P.S. CAUBRATIQN 8(
D-19367-411-110-31 19367-ICE-3014 8 3 INDICATION PANEL C~O ~S INDICATION PANEL INDICATION PANEL INDICATION PANEL EXCORE UNEAR ISOLATION ASSEMBLY SEE SPEC:
WW SEE SPEC. 19367-ICE-501 AND NOTE 6 444 RUNDEL 551-2SR-2A-DGI WITH SA-3C TCB 3 TCB 4 (Aw1 I )
TCB 5 TCB 6 (Bwl I) (Cwl I) (Dwl I)
TRIP CIRCUIT TRIP CIRCUIT BREAKER RESET BREAKER RESET 03955 GU!SE GLGSE GLGSE 20 CHANNEL A TRIP UNITS CHANNEL 8 TRIP UNITS CHANNEL C TRIP UNITS CHANNEL D TRIP UNITS TCB I TCB 2 TCB 7 TCB 6 8-3 /4 (12MAX) (1 2 MAX) (12MAX)
MJ+ (12MAX) 6 11 22 23 B II 22 23 (Bw4) (cw4) (DW4) 21 Z aaa (AW4)
ED g 90 7. THE AUDIO CQUNTRATE SPEAKER SHALL BE MOUNTED TRIP TEST CABLE PANEL TRIP TEST CABLE PANEL 6 10 TRIP TEST CABLE PANEL 10 BEHIND THE BLANK FRONT PANEL HOLES SHALL BE 3-1/2 TRIP TEST'CABLE PANEL 5 6 MATRIX MATRIX DRILLED TQ ALLOW SOUND TQ PENETRATE FRONT PANEL.
7 POWER 11 12 POWER 14 CJ W SUPPLY TRIP INHIBIT SWITCH PANEL 15 SUPPLY 16 TRIP INHIBIT SWITCH PANEL 6. THE R.P.S. POWER SUPPLY ASSEMBLIES SHALL BE MOUNTED 13 TRIP INHIBIT SWITCH PANEL Oe 3-1/2 TRIP INHIBIT SWITCH PANEL (AW5) 9 (BW5) (cws) (Dwe) ON CHASSIS SLIDES AT TQP REAR OF CABINET.
BC MATRIX TEST BD MATRIX TEST Ac MATRIX TEST CD MATRIX TEST AD MATRIX TEST 5 CHANNEL IDENTIFICATION PLATES SHALL BE MOUNTED AS TEST POWER SUPPLY AB MATRIX TEST SHOWN ON FRONT ANQ REAR OF CABINET ASSEMBLY.
PLATES SHALL BE COLOR CODED AS FOLLOWS:
24 3 24 CHANNEL A (RED), CHANNEL 8 (YELLOW), CHANNEL C (GREEN) 8c CHANNEL 0 (BLUE).
(Awe) (AW7) (Bwe) (BW7) (CW6) (CW7) (Dwe) (DW7) 4 ALL PANEL DIMENSIONS SHALL CONFORM TO E A STANDARD I
- 3. ALL PANEL DIMENSIONS SHALL CONFORM TQ E.I.A. STANDARD RS-310 FOR STD. 19 INCH PANEL EXCEPT FOR AUXILIARY LOGIC ASSEMBLY AUXILIARY LOGIC ASSEMBLY AUXILIARY LOGIC ASSEMBLY "TRIP STATUS PANEL .
AUXILIARY LOGIC ASSEMBLY I
I METAL SHIM STRIPS TQ BE USED BETWEEN INDIVIDUAL (AWI 0) (BWI 0) (CWI 0) (DWI 0) 29 PANELS AND CABINETS AS NECESSARY TQ PROVIDE APPEARANCE OF UNIFORM FRONT PANEL THICKNESS.
CORE PROTECTION CORE PROTECTION CORE PROTECTION CORE PROTECTION CALCULATOR CALCULATOR CALCULATOR CALCULATOR 8-3/4 No.2 No.2 No.2 No.2 CC 03 (AW15) (BW15) (cwl5) (DW15) 18 Z
'-'I CORE PROTECTION TD CORE PROTECTION CORE PROTECTION Z CORE PROTECTION CALCULATOR CALCUlATOR CALCULATOR CALCULATOR No. I No. I No.l No. I a
L (AWI 2) (BW12) (CW12) (DW12) 25 ae aa II aoc IDB PANEL MOUNTING BASE I~!I aa8 QI NUCLEAR INSTRUMENTATION AND REACTOR PROTECTIVE SYSTEM (SUPPLIED BY OTHERS) 8770-1288 SEE NOTE 4 FLOct04 POWER 4 UOH( COMPANY 13 6(. LU(t( PLAN( UNIT 41 CQMPARATQR AVERAGER P.O. (6-2562 CC DRAWER 03 (AW13)
Z LOCATED IN REAR Dl fo OF CABINET "A 12-1/4 ISOLATION POWER RATIO NUCLEAR INSTRUMENTATION 8 TRAC-2 ASSEMBLY REACTOR PROTECTION SYSTEM CALCULATOR CABINET ASSEMBLY EXCQRE LINEAR AMPLIFIER ISOLATION ASSEMBLY FRONT PANEL LAYOUT (DW13) (AWI 8) (A-THRU-DWI6) (AWI 7)
/a/
LOCATED IN REAR OF CABINET "D"
28 LOCATED IN REAR OF CABINET. A" 27 LOCATED IN REAR OF CABINETS A" THRU D" 30 LOCATED IN REAR OF CHANNELS A-D, BEHIND A-DWI I THIS DRAWING WAS REPRODUCED COMBUSTION ENGINEERING DRAWING c c <<alwl a
No. E-19367 411 021, REV.5 c L 5 I. e L 8 USEOO 477. DWG