Instructions for Completing Nuclear Material Transaction Reports (DOE/NRC Forms 741 and 740M)
Effective Date: May 4, 2018 Office of Nuclear Material Safety and Safeguards NUREG/BR-0006, Rev. 8
iii NUREG/BR-0006, Rev. 8 ABSTRACT U.S. Nuclear Regulatory Commission (NRC) regulations require licensees who ship, receive, or adjust their physical inventory of source or special nuclear material (SNM) to document and report such activities. The reports are submitted using U.S. Department of Energy (DOE)/NRC Form 741. Licensees may need to provide additional information on some imports or exports of source or SNM. The additional information is reported using DOE/NRC Form 740M. This NUREG contains instructions for preparing these forms.
Paperwork Reduction Act Statement The information collections contained in this NUREG are covered by Department Of Energy (DOE)/NRC Forms 741 and 740M, which the Office of Management and Budget (OMB) approved under approval numbers 3150-0003 and 3150-0057. The estimated burden per response to comply with this mandatory collection request is 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 15 minutes for DOE/NRC Form 741 and 45 minutes for DOE/NRC Form 740M. The information is required for IAEA accounting reports that show changes in inventory of nuclear materials. Send comments regarding burden estimates to the Information Services Branch (T-5 F53), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by email to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202 (3150-0003, 3150-0057). Office of Management and Budget, Washington, DC 20503.
Public Protection Notification The NRC may not conduct or sponsor, and a person is not required to respond to, a collection of information unless the document requesting or requiring the collection displays a currently valid OMB control number.
v NUREG/BR-0006, Rev. 8 CONTENTS ABSTRACT............................................................................................................................... iii ABBREVIATIONS.................................................................................................................... vii 1 INTRODUCTION................................................................................................................... 1 1.1 Material Transaction Reports........................................................................................ 1 1.2 Regulatory Authority..................................................................................................... 2 1.3 Reporting/Distribution Requirements............................................................................ 3 1.4 Methods for Preparing and Submitting Data to the Nuclear Materials Management and Safeguards System.......................................................................... 4 1.5 Documentation and Distribution.................................................................................... 4 2 GENERAL INSTRUCTIONS................................................................................................. 7 2.1 Instructions for Completing DOE/NRC Form 741 Reports............................................ 7 2.1.1 Reporting Shipper's Data..................................................................................... 7 2.1.2 Reporting Receiver's Data................................................................................. 18 2.2 Preparation of DOE/NRC Form 741 in Computer-Readable Format........................... 20 2.3 Distribution of DOE/NRC Form 741............................................................................ 20 2.3.1 Shipper.............................................................................................................. 20 2.3.2 Receiver............................................................................................................ 21 3 INSTRUCTIONS FOR ONSITE GAINS AND LOSSES (M ACTION CODE)....................... 23 3.1 Instructions for Completing DOE/NRC Form 741........................................................ 23 3.2 Preparation of DOE/NRC Form 741 in Computer-Readable Format........................... 25 3.3 Distribution of DOE/NRC Form 741....................................................................... 25 4 INSTRUCTIONS FOR CORRECTING A DOE/NRC FORM 741 (C, D, AND M ACTION CODES OR Z PROCESS CODE).................................................. 27 4.1 Originator.................................................................................................................... 27 4.2 Receiver...................................................................................................................... 28
NUREG/BR-0006, Rev. 8 vi CONTENTS 4.3 Use of the Z Process Code......................................................................................... 28 4.4 Distribution of Corrections to DOE/NRC Form 741..................................................... 28 5 INSTRUCTIONS FOR COMPLETING DOE/NRC FORM 740M.......................................... 31 6 DOE REPORTING REQUIREMENTS FOR PROPRIETARY INTERESTS OF THE GOVERNMENT.................................................................................................................. 35 7 REFERENCES.................................................................................................................... 37 APPENDIX A COMPOSITION CODES.......................................................................... A-1 APPENDIX B INVENTORY CHANGE TYPE CODES FOR COMPLETING BLOCKS 26C AND 27C OF DOE/NRC FORM 741.................................. B-1 APPENDIX C EXAMPLE DOCUMENTATION OF SHIPPER AND RECEIVER DATA (BLOCKS 26 AND 27).................................................................... C-1 APPENDIX D GLOSSARY.............................................................................................. D-1 APPENDIX E DOE/NRC FORM 740M, CONCISE NOTE, (BLANK) AND DOE/NRC FORM 741, NUCLEAR MATERIAL TRANSACTION REPORT (BLANK).................................................................................. E-1 APPENDIX F SUPPLEMENTAL INSTRUCTIONS FOR COMPLETING BLOCKS 17, 18, 19, 20, AND 21 ON DOE/NRC FORM 741.................................... F-1 APPENDIX G SUPPLEMENTAL INSTRUCTIONS FOR POSSESSORS OF NUCLEAR MATERIAL OUTSIDE FACILITIES REPORTING PURSUANT TO THE MODIFIED SMALL QUANTITIES PROTOCOLG-1
vii NUREG/BR-0006, Rev. 8 ABBREVIATIONS ANSI American National Standards Institute BI beginning inventory CFR Code of Federal Regulations DOE U.S. Department of Energy EI ending inventory EURATOM European Atomic Energy Commission FA facility attachment g
gram HEU highly enriched uranium IAEA International Atomic Energy Agency ICR inventory change report ICT inventory change type ID inventory difference kg kilogram KMP key measurement point LEU low-enriched uranium MBA material balance area MBR material balance report MT material type NMMSS Nuclear Materials Management and Safeguards System NRC U.S. Nuclear Regulatory Commission OMB Office of Management and Budget OMP other measurement point Pu plutonium RA rounding adjustment RIS reporting identification symbol SAMS Safeguards Management Software SNM special nuclear material SRD shipper-receiver difference
NUREG/BR-0006, Rev. 8 viii TFA transitional facility attachment U
uranium UF6 uranium hexafluoride UK United Kingdom WR former Soviet Union weapons material
1 NUREG/BR-0006, Rev. 8 U.S. NUCLEAR REGULATORY COMMISSION INSTRUCTIONS FOR COMPLETING NUCLEAR MATERIAL TRANSACTION REPORTS DOE/NRC Form 741, Nuclear Material Transaction Report, and DOE/NRC Form 740M, Concise Note 1 Introduction The U.S. Nuclear Regulatory Commission (NRC) and the U.S. Department of Energy (DOE) jointly use the Nuclear Materials Management and Safeguards System (NMMSS). This system is the U.S. national database used by DOE and the NRC for tracking certain nuclear material.
Common reporting forms and formats are used to minimize the reporting burden on licensees1 required to provide nuclear material data to one or both agencies in accordance with current regulations or contractual obligations. In this manner, licensees can file one report to meet the reporting requirements of both the NRC and DOE. Compliance with specific reporting requirements is monitored by the agency that requires the specific data. NRC regulations require that licensees submit the reports in computer-readable form. A licensee may use any blank blocks on the paper DOE/NRC forms for other business purposes.
DOE requires all NRC licensees to report to the NMMSS all receipts, transfers, and inventories of U.S. Government-owned, -loaned, or -leased material in their possession. Reports to the NMMSS for all U.S. Government-owned, -loaned, or -leased material must follow the U.S. Governments reporting requirements as specified in DOE Orders Series 470 (DOE Order 470.4, Safeguards and Security Program, and DOE M 470.4-6, Nuclear Material Control and Accountability).
1.1 Material Transaction Reports DOE/NRC Form 741, Nuclear Material Transaction Report, is the means for submitting transaction data to the NMMSS. DOE/NRC Form 741 must be completed in accordance with the instructions in this NUREG and must be submitted in computer-readable format. NMMSS Report D-24, Personal Computer Data Input for NRC Licensees, gives instructions for creating the computer-readable submittal.
Licensees use DOE/NRC Form 741 to report physical transfers of nuclear materials between facilities. The report is also used to convey information on transactions such as inventory corrections that otherwise increase or decrease obligation balances or nuclear material categories within a facility.
The NMMSS relies heavily on the quality of the data reported by the facilities involved in nuclear activities. The data submitted to the NMMSS are subject to evaluation according to the restrictions placed on nuclear activity by the policies of various governing agencies of the United 1
The term licensee here denotes an NRC or Agreement State licensee or an NRC certificate holder.
NUREG/BR-0006, Rev. 8 2
States. The NMMSS accepts the data after they are verified as acceptable within the restrictions of the system.
NRC licensees must provide a DOE/NRC Form 741 to the NMMSS in a computer-readable format following the instructions in this NUREG and NMMSS Report D-24. Both the shipper and the receiver are required to submit DOE/NRC Form 741. The receiver should confirm that the quantity received is consistent with the shippers report. When statistically significant shipper-receiver differences (SRDs), as defined in Title 10, Section 74.31, Nuclear Material Control and Accounting for Special Nuclear Material of Low Strategic Significance, of the Code of Federal Regulations (10 CFR 74.31),10 CFR 74.43, Internal Controls, Inventory, and Records, or 10 CFR 74.59, Quality Assurance and Accounting Requirements, are identified, they must be resolved and their root causes corrected. The regulatory intent is to require material control and accounting systems to promptly detect and resolve all significant SRDs. Comparisons of shippers and receivers reports are necessary both to confirm the acceptability of shippers and receivers values for establishing the book accounting amounts for received material and to detect unacceptable shippers= or receivers= values. Comparisons typically involve item verification, seal integrity, gross weights, nondestructive assay measurements (if appropriate),
and destructive measurements (if appropriate).
1.2 Regulatory Authority Title 10 of the Code of Federal Regulations sets forth reporting requirements for specified activities.
For reporting transactions for special nuclear material (SNM), NRC regulations 10 CFR 72.78, 10 CFR 74.15, 10 CFR 75.34, 10 CFR 76.113, 10 CFR 76.115, 10 CFR 76.117, and 10 CFR 150.16 require, in part, that each licensee who transfers or receives SNM of any origin must complete, in computer-readable format, a DOE/NRC Form 741. This should be done in accordance with instructions in this NUREG whenever the licensee or certificate holder transfers or receives a quantity of SNM of 1 gram or more contained uranium (U)235, U233, or plutonium.
Reporting for plutonium (Pu)238 is to the nearest one-tenth of a gram of the Pu238 isotope.
For reporting transactions for source material, NRC regulations 10 CFR 40.64, Reports, and 10 CFR 150.16, Submission to Commission of Nuclear Material Transfer Reports, state, in part, that except as specified within those sections, each licensee must complete and distribute a DOE/NRC Form 741 when the licensee in any manner transfers, receives, or adjusts the inventory of source material of foreign obligations by 1 kilogram or more or imports or exports 1 kilogram or more of uranium or thorium source material. In addition, a licensee who uses 1 kilogram or more of any uranium or thorium source material in enrichment services, downblending uranium that has an initial enrichment of the U235 isotope of 10 percent or more, or in the fabrication of mixed-oxide fuels. The licensee must complete DOE/NRC Form 741 in computer-readable format in accordance with instructions in this NUREG and in NMMSS Report D-24. Optionally, if using XML format, licensees may report source material to three decimal places; however, both the shipper and receiver must report at the kilogram unit, unless they both agree to report at the three-decimal unit. If using three-decimal reporting, then the reporting unit is to the nearest thousandth of a kilogram. For example, both the shipper and receiver may report 1655 grams as 1.655 kilograms. However, for consistency, the licensee must continue to report to the same decimal place for that material type. When reporting source
3 NUREG/BR-0006, Rev. 8 material to three decimal places, both the detail and obligation weight must be reported to the same decimal place.
For reporting transactions for source material or SNM in accordance with an agreement with the International Atomic Energy Agency (IAEA), NRC regulation 10 CFR 75.31, General Requirements, requires licensees to complete and distribute DOE/NRC Form 741 for all source material or SNM inventory changes, including shipments, receipts, onsite gains and losses, and any other inventory adjustments. These reports must be in computer-readable format and must be based on the records kept in accordance with 10 CFR 75.22, 10 CFR 75.31, 10 CFR 75.32, 10 CFR 75.33, 10 CFR 75.34, and 10 CFR 75.35.
Licensees can comply with these reporting requirements by completing DOE/NRC Form 741 and transmitting it in computer-readable format following the guidance in this NUREG and in NMMSS Report D-24.
In addition, the submission of DOE/NRC Form 741 is normally required as a matter of contract or lease administration for all Government-owned nuclear material transferred (see DOE Orders Series 470 (DOE Order 470.4 and DOE M 470.4-6)).
1.3 Reporting/Distribution Requirements Reports are required whenever nuclear material in the types and amounts stated in the preceding section moves between locations or operations that have been assigned different reporting identification symbols (RISs) and whenever SNM and source material inventories change. The nuclear material change data (including burnup, production, measured discards, category changes, and decay) must be documented and reported to the NMMSS before or at the same time as the physical inventory taking, unless the NRC has authorized another arrangement.
The shipper initiates a DOE/NRC Form 741. If the licensee is involved in a transfer of material with a party that is not required to prepare a DOE/NRC Form 741, the licensee must prepare and submit both the shippers and the receivers section of DOE/NRC Form 741. The most common situation is when a domestic facility is involved in export/import activities. The domestic facility must obtain the information necessary to complete DOE/NRC Form 741 for the foreign facility for all imports of SNM and source material. In the case of exports, the shipper initiates a DOE/NRC Form 741 report, and the NMMSS will generate a DOE/NRC Form 741 report using shipper information. However, if a significant SRD is identified between the U.S.
shipper and foreign receiver (as defined in 10 CFR 74.31, 10 CFR 74.43, or 10 CFR 74.59 for SNM, or if there is an indication of loss, theft, or diversion of quantities of source material delineated in 10 CFR 40.64(c)(1)), the shipper is required to document the foreign partys values in a DOE/NRC Form 741 report to the NMMSS. Submittal for a foreign facility does not indicate a responsibility for the other facility or its shipment/receipt of materials.
Reports of physical shipments between RISs must document the actual movement of material.
In addition, any reportable information associated with the material must also be reported. In particular, the obligation of material by a foreign entity must follow the physical movement of material between RISs. The transfer of obligations between RISs with no physical movement of material is reported by using action codes X and Y.
NUREG/BR-0006, Rev. 8 4
1.4 Methods for Preparing and Submitting Data to the Nuclear Materials Management and Safeguards System The Safeguards Management Software (SAMS) is a miniature version of the NMMSS. This software allows the user to import and export data, make edit checks, generate various reports, and create material balance, inventory data, and transaction data. It has the capability to export data into the required NMMSS predefined computer-readable format outlined in NMMSS Report D-24. The SAMS program may be obtained from the NMMSS operator free of charge.
Licensees can submit data to the NMMSS via the following three methods:
(1)
Telephonic Transfers A licensee may submit DOE/NRC Form 741 electronically by using a modem. To establish an electronic connection with the NMMSS, licensees must contact the NMMSS security officer to request the establishment of a connection with the direct link. If the facility is a valid facility for the type of link requested (classified or unclassified), then the security officer will provide the requester with the appropriate forms to complete.
Upon receipt of the completed forms, the security officer will create a user identification and password and establish an account for the facility. The user identification and password will then be forwarded to the user facility along with a password acknowledgment form. The licensee will sign the acknowledgment form and return it to the security officer, who will then activate the user identification and password.
(2)
Data Submittals on Computer Media NMMSS Report D-24 provides instructions on packaging, data format requirements, acceptable media types, and the mailing address for the submittal of data on computer media.
(3)
New and Modified Methods of Transferring Electronic Data The NRC may authorize new and modified methods of transferring electronic DOE/NRC Form 741 data to the NMMSS. Licensees may confirm authorization to use additional methods for the transfer of these data by contacting the NMMSS operator.
1.5 Documentation and Distribution The completed DOE/NRC Form 741, in computer-readable format, must be submitted to the NMMSS operator. Licensees can confirm the address and mechanism for providing data to the NMMSS by calling the NMMSS operator. Specific submission instructions depend on whether
5 NUREG/BR-0006, Rev. 8 the DOE/NRC Form 741 is classified or unclassified information. Sections 2.3, 3.3, and 4.4 of this NUREG contain additional distribution information.
Any DOE/NRC Form 741 that is classified must be documented and handled in accordance with all pertinent security requirements. All other submissions that are not classified are considered to be proprietary material control and accounting information and may be requested to be withheld as defined by 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding. Each person who is to receive a copy of the report must be verified as a qualified recipient before distribution. Licensees should confirm the address before sending documents to the NMMSS or other recipients. They should also formally provide classification guidance to the NMMSS operator after a decision to classify, declassify, or make any change in previously submitted guidance. To submit Safeguards Information, licensees should use Form 740M, Concise Note, stating that the submission is Safeguards Information and should be handled in accordance with 10 CFR 73.21, Requirements for the Protection of Safeguards Information.
7 NUREG/BR-0006, Rev. 8 2 GENERAL INSTRUCTIONS 2.1 Instructions for Completing DOE/NRC Form 741 Reports If the DOE/NRC Form 741 report is documenting an onsite gain or loss, the licensee should review the instructions for block 6 (ACTION CODE) and the special instructions for the M action code in Section 3 of this NUREG before completing the form.
The numbered instructions below correspond to the numbered blocks on the paper copy of DOE/NRC Form 741. Each shipper of reportable quantities of SNM or source material (refer to blocks 26n and 26q) must send a DOE/NRC Form 741 report to the NMMSS operator and a copy to the receivers business address no later than the close of business the next working day.
In the case of spent fuel shipments, in accordance with 10 CFR 73.37, Requirements for Physical Protection of Irradiated Reactor Fuel in Transit, the date of shipment is Safeguards Information until 10 days after the shipment or the last shipment in a series of shipments is received. Therefore, DOE/NRC Form 741 should be identified as Safeguards Information, and a Concise Note Form 740M must be submitted stating that the submission is Safeguards Information and should be handled in accordance with 10 CFR 73.21. Concise Note Form 740M should also contain other pertinent information such as whether this is a single shipment or part of a series and the shipment number and total within the series.
For disposals, the burial site operator must prepare and transmit DOE/NRC Form 741 to the NMMSS to document receipt and disposal. NRC regulations stipulate that the DOE/NRC Form 741 reports be submitted in computer-readable format. NMMSS Report D-24 gives the electronic formats for DOE/NRC Form 741.
2.1.1 Reporting Shippers Data Licensees should complete DOE/NRC Form 741 in accordance with the following instructions:
- 1.
SHIPPERS RIS2Enter the shippers RIS.
- 2.
RECEIVERS RIS2Enter the receivers RIS.
- 3.
TRANSACTION NUMBEREnter a number for the same shipper-receiver combination.
Numbers in the series must be consecutive (i.e., no skipped numbers).
2 NMMSS Reports D-2, D-3, and D-15 document RISs.
NUREG/BR-0006, Rev. 8 8
- 4.
CORRECTION NUMBERThis block is used to identify a transaction that is an adjustment to a previously issued DOE/NRC Form 741. Leave this block blank for an original submission of a DOE/NRC Form 741. Use consecutive numbers, starting with 1, for adjustments. Refer to NMMSS Report D-24 for field sizes. For corrections requiring changes only to NMMSS data (and not to the other partys data), use letters (A, B, etc.)
instead of numbers. See Section 4 of this NUREG.
- 5.
PROCESS CODEEnter process code A, C, D, or Z.
A refers to the initial entry of data.
C refers to the replacement of data. With the concurrence of the other party to the transaction, up to an entire data set may be replaced at any time before the close of the NMMSS processing period in which the initial submittal was made.
D refers to the deletion of data. An entire data set may be deleted at any time before the close of the NMMSS processing period in which the initial submittal was made, with the concurrence of the other party to the transaction.
Z refers to the receivers acceptance of other partys correction. This processing code can be used only with action code D. Receivers reporting in accordance with 10 CFR Part 75, Safeguards on Nuclear MaterialImplementation of U.S./IAEA Agreement, may not use the Z code.
- 6.
ACTION CODEThis block is used to identify the type of transaction being reported on DOE/NRC Form 741 as specified in 6a and 6b below.
6a.
SHIPPEREnter one of the following action codes:
A The shipper is reporting a transaction that has taken place between the stated parties.
C The shipper is adjusting the initial DOE/NRC Form 741 for the shipment or a previous adjustment to the same initial report, acknowledging an adjustment originated by the receiver, or accepting and agreeing with the receivers adjustment to DOE/NRC Form 741. See Section 4 of this NUREG.
M The shipper is reporting a one-party transaction or an adjustment to a one-party transaction (e.g., an onsite gain or loss of material as the result of burnup, production, measured discards, category changes, etc.). DOE/NRC Form 742, Material Balance Report, shows such inventory changes. See Section 3 of this NUREG.
R The shipper is identifying a one-party transaction to delete an obligated amount of material from the facility=s inventory. This code is applicable only to former Soviet Union weapons (WR) material after the fresh low-enriched uranium (LEU)
9 NUREG/BR-0006, Rev. 8 is irradiated in a reactor core. Use of this code implies a removal of WR material; therefore, the value should be entered as a positive number.
X The shipper is reporting a transfer of obligation that involves no physical movement of material. No obligation transfers of WR material are permitted. No shipper (block 26) or receiver (block 27) detail data need be entered.
6b.
RECEIVEREnter one of the following action codes:
B The receiver is reporting that a shipment has been received and that the weights reported by the shipper on DOE/NRC Form 741 were accepted as final receipt values.
E The receiver is reporting that a shipment was received, that independent measurements were made, and that the values resulting from the independent measurements are being reported.
D The receiver is adjusting the initial DOE/NRC Form 741 that documented the receipt of a shipment or a previous adjustment to the same initial report, or acknowledging an adjustment originated by the shipper, or accepting and agreeing with the shippers adjustment to DOE/NRC Form 741. See Section 4 of this NUREG.
M The receiver is reporting a one-party transaction or an adjustment to a one-party transaction (i.e., an onsite gain or loss of material as the result of burnup, production, measured discards, etc.). DOE/NRC Form 742 shows such inventory changes. See Section 3 of this NUREG.
N The receiver is reporting physical receipt of a shipment but will delay the quantity determinations for the shipment of material for more than 10 days but no more than 60 days for source and LEU, or no more than 45 days for highly enriched uranium (HEU). At the end of this time, the receiver will prepare a DOE/NRC Form 741 with a B or E action code to report the receivers quantity determinations. Use of this code (N) requires no entry of detailed data (block 27) by the receiver.
Y The receiver is reporting an acceptance of transfer of obligation that involves no physical movement of material. No shipper (block 26) or receiver (block 27) detailed data need be entered.
- 7.
DOCUMENTATIONThis block is for paper-copy submissions only. Enter the number of pages if the submission is classified.
- 8. SHIPPERLeave blank.
- 9.
RECEIVERLeave blank.
NUREG/BR-0006, Rev. 8 10
- 10. NUMBER OF DATA LINESAfter completing block 26 (SHIPPERS DATA), or block 27 (RECEIVERS DATA), enter the total number of detail lines in block 26 or 27. The shipper and receiver must report the same number of entries, and the material types must agree line for line.
- 11. NATURE OF TRANSACTION Leave blank.
- 12.
SHIPPED FOR ACCOUNT OFLeave blank.
- 13.
SHIPPED TO ACCOUNT OFLeave blank.
- 14.
TRANSFER AUTHORITYLeave blank.
- 15.
EXPORT OR IMPORT TRANSFERSFor all export or import transfers, enter the NRC export or import license number under which SNM or source material is being transferred. Where transfers are authorized by an NRC general license, enter GEN-LIC.
In some cases, the transfer may be exempt from licensing, such as exports of IAEA safeguards samples; then enter LIC-EXEMPT. If several batches authorized by separate licenses are combined into one shipment, a separate DOE/NRC Form 741 must be completed for the portion associated with each import/export license.
- 16.
MATERIAL TYPE AND DESCRIPTIONLeave blank.
- 17.
LINE NUMBEREnter a sequential line number beginning with the number 1. Refer to the NMMSS Report D-24 for field sizes.
- 18.
COUNTRY OF OBLIGATIONEnter the two-character country or entity designation from Table 1 in Appendix F for the line numbers entered in block 17. See Appendix F to this NUREG for further instructions.
- 19.
MATERIAL TYPEEnter the material type to which the obligation is attached. Refer to Table 2 in Appendix F. The only material types to be reported are 10, 20, 50, 70, 81, and 88.
- 20.
OBLIGATED ELEMENT WEIGHTEnter the weight of the obligated amount of the element. Refer to NMMSS Report D-24 for field sizes. See Appendix F for further instructions. Positive or negative values should be entered to appropriately account for material addition or removal, respectively. Reports with an action code of A, B, E, R, X, or Y must be reported with a positive weight. All others can be reported with a positive or negative weight. The sum of obligated material for a material type cannot exceed the sum of the weight value listed in the detail lines.
- 21.
OBLIGATED ISOTOPE WEIGHTFOR ENRICHED URANIUM ONLYEnter the weight of the obligated amount of the isotope. Refer to NMMSS Report D-24 for field sizes. For in-place activity, positive or negative values should be entered to appropriately account for material addition or removal, respectively. Reports with an action code of A, B, E, R, X, or Y must be reported with a positive weight. All others can
11 NUREG/BR-0006, Rev. 8 be reported with a positive or negative weight. The sum of obligated material for a material type cannot exceed the sum of the weight value listed in the detail lines.
- 22.
ACTION DATEFollow the instructions below for blocks 22a through 22e.
22a.
SHIPMENT (entry required by shipper)Enter the date the nuclear material is shipped.
22b.
SHIPPERS CORRECTION (entry required by shipper)If the document is an acknowledgment of or a correction to a previously issued transaction report, enter the date the correction is recorded or the acknowledgment made, as appropriate. However, dates on acknowledgments must not precede the action date listed on the receivers correction. Additionally, be aware that if a date preceding the current unreconciled period is used, the effect of the correction will be reflected in the current period, not the prior period(s) covered by postdated documents.
22c.
RECEIPT (entry required by receiver)Enter the date the nuclear material is received.
22d.
RECEIVERS MEASUREMENT (entry required by receiver)This entry is required only if the receivers action code is E. Enter the date the nuclear material is measured by the receiver.
22e.
RECEIVERS CORRECTION (entry required by receiver)If the document is an acknowledgment or a correction to a previously issued transaction report, enter the date the correction is recorded or the acknowledgment made, as appropriate. However, dates on acknowledgments must not precede the action date listed on the receiver=s correction. Additionally, be aware that if a date preceding the current unreconciled period is used, the effect of the correction will be reflected in the current period, not the prior period(s) covered by postdated documents.
Note that in the case of all imports (and for some exports, see Section 1.3), licensees must complete a separate DOE/NRC Form 741 to document the foreign party action, including action dates in blocks 22a and 22c, as applicable.
23a.
MISCELLANEOUSLeave blank.
23b.
CONCISE NOTE ATTACHED Leave blank.
23c.
UK REPORTABLEFacilities reporting material transfers involving facilities in the United Kingdom must indicate in this block whether the shipment is reportable or nonreportable to IAEA. Check YES for reportable or NO for nonreportable.
Note that typically all licensee shipments to/from the United Kingdom are reportable.
- 24.
TOTAL GROSS WEIGHTEnter the total gross weight of the shipment rounded to the nearest kilogram. An approximate or estimated gross weight rounded to the nearest kilogram is acceptable. Make no entry for M action code transactions, receipts, obligation transfers, and correction documents.
NUREG/BR-0006, Rev. 8 12
- 25.
TOTAL VOLUME (WASTE TRANSFERS ONLY)For transfers of nuclear material to nuclear waste sites (i.e., receiver RIS begins with the letter V), enter the volume of the material to be buried, stated in cubic feet rounded to the nearest cubic foot. An entry in block 25 is not required for transfers to nuclear laundry services.
- 26. SHIPPERS DATAEnter the shippers data in block 26. Enter the receivers data in block 27. Receivers should review the additional instructions for block 27 before completing the form.
Shipper and receiver measurement data are entered on DOE/NRC Form 741 for each batch of material. For licensees reporting pursuant to the requirements of 10 CFR Part 75, or if the transfer is an import or an export, a batch is a portion of nuclear material that is handled as a unit for accounting purposes at a key measurement point (KMP) and whose composition and quantity are defined by a single set of specifications or measurements. The batch may be in bulk form or contained in a number of separate items. If the shipment is an export or is being reported pursuant to 10 CFR Part 75, fuel assemblies or loose rods or fuel pins must be listed separately with the identifying label serving as a unique batch name. Fuel assemblies can be reported as average enrichment as long as the appropriate accounts (material types 10, 20, 81, etc.) are properly adjusted. Material being transferred may be listed on one line of DOE/NRC Form 741 if the material is all of the same material type, composition, ownership, and weight percent of isotope (except as noted in the next paragraph). Material differing in any of these data elements must be listed on separate lines.
Two or more lines may be necessary to describe a single batch (e.g., spent fuel assemblies, mixed-oxide fuel). If a batch consists of several types of nuclear material, several consecutive lines should be used to describe the batch. The batch name should be repeated on all lines used to describe a single batch. In block 26e, the number of items is also repeated on all lines with the same batch name.
The above general rules for grouping or batching material for reporting purposes are also applicable to licensees reporting imports or exports pursuant to 10 CFR Part 40, Domestic Licensing of Source Material, 10 CFR Part 74, Material Control and Accounting of Special Nuclear Material, or 10 CFR Part 75. Batch names are optional for other transactions reported pursuant to 10 CFR Part 40 or 10 CFR Part 74.
26a.
BACK REFERENCE NUMBEREnter the appropriate back-reference number adjustments to previously completed DOE/NRC Form 741 documents.
Licensees must enter the back reference numbers for action codes C and D and for action code M when reporting adjustments. Licensees must report both the back-reference change digit and the back-reference line number.
The back-reference change digit represents the change digit of the document being corrected for a nullifying entry and the change digit of the document now being completed for a correcting entry. For example, if the DOE/NRC Form 741 being corrected is the original, or if the line being entered represents an addition only, enter 0 (zero).
13 NUREG/BR-0006, Rev. 8 The back-reference line number represents the line number of the line being corrected for a nullifying entry and the line number of the corresponding nullifying line for a correction entry. If the line being entered represents an addition only or represents a net change, enter zeros.
26b.
LINE NUMBERIn providing detailed measurement data, enter a line number beginning with 1 for the first line of detailed shippers data and increase the line number by one for each additional line of detailed shippers data entered on the form. When two or more lines of measurement data refer to a single batch, repeat the unique batch name for each line of the batch data. For example, repeat the batch name when different material types of multienrichment fuel rods are entered on separate lines or when uranium hexafluoride (UF6) product material and UF6 heel material in a cylinder are reported on separate lines.
26c.
TYPE OF INVENTORY CHANGEAll changes to inventory that meet the reporting criteria must be reported on DOE/NRC Form 741.
Appendix B explains the inventory change type (ICT) codes and indicates whether they are to be entered in block 26c. Enrichment facilities may use the two-digit numerical value for indicating a change type or proceed as directed by the NRC. When shipping to a V RIS, the shipper must use ICT code 74. A measured discard can be documented as an onsite transfer, a discard to a pond/lagoon, or as transferred to a holding area.
Discharges to lagoon and movement to holding areas are documented with a suffix attached to the RIS:
Use L when material is discarded into a pond or lagoon.
Use H when material is transferred to a holding area (refer to the term holding account in the glossary in Appendix D) at the facility pending possible shipment offsite for disposal Note that use of a holding or lagoon account requires establishment of account and prior approval by the NRC.
The shipper should enter its RIS in block 1 (SHIPPERS RIS) and the same RIS in block 2 (RECEIVERS RIS), but append an L or H to the receivers RIS as appropriate.
For example, if a facility with RIS XYZ discards material to a lagoon, the transaction on DOE/NRC Form 741 would be from XYZ to XYZL.
26d.
IDENTIFICATION (ITEM/BATCH NAME)Enter a name or number, or a combination of both, that identifies the batch of material being shipped. If the licensee is reporting pursuant to 10 CFR Part 75, or if the transfer is an import or export, the shipper or receiver enters a name that identifies a unique portion of nuclear material handled as a unit for accounting purposes. For fuel pins and rods, the batch name should be the identification numbers of the fuel pin or rod.
NUREG/BR-0006, Rev. 8 14 In the case of an import, the receiver must use the same batch name as the shipper, provided that the shippers batch name conforms to the above specifications. If it does not, submit a concise note in accordance with the instructions (Section 5) explaining the difference. When two or more lines of measurement data refer to a single batch, repeat the unique batch name for each line of the batch data. For example, repeat the batch name when different material types of multienrichment fuel rods are entered on separate lines or when UF6 product material and UF6 heel material in a cylinder are reported on separate lines.
26e.
NUMBER OF ITEMSEnter the number of similar items of which the line entry consists (e.g., cylinders, packs, drums, bird cages, bottles, tank vessels). When reporting fuel pins, rods, or plates, report the number of separate fuel pins, rods, or plates involved.
When reporting fuel assemblies, report the number of complete assemblies represented on the line entry. In the case of transfer of bulk material, enter the number 1. Leave blank if an M action code is used.
26f.
PROJECT NUMBERLeave blank.
26g.
MATERIAL TYPEEnter the appropriate SNM or source material type code from the list below.
U.S. Code (Domestic transfers)
IAEA Code (Imports/Exports)
Description 10 D
Depleted uranium 20 EG Enriched uranium 50 P
Plutonium 70 EK U233 81 N
Normal uranium 833 Pu Pu238 88 T
Thorium 89 To be obtained from IAEA Uranium in cascade 26h.
COMPOSITION/FACILITY CODEEnter the appropriate code describing the physical form (unencapsulated, encapsulated, etc.) and the chemical form of the material. See Appendix A.
If the installation has been notified by letter from the NRC, as provided in 10 CFR 75.11, Installation Information, that it has been identified under the U.S./IAEA Safeguards Agreement, enter the appropriate code from the list developed during the formulation 3
Report as Pu238 if the contained Pu238 is greater than 10 percent of total plutonium by weight; otherwise, report as plutonium.
15 NUREG/BR-0006, Rev. 8 and negotiation of the facility attachment (FA) or transitional facility attachment (TFA) provided pursuant to 10 CFR 75.8, Facility Attachments.
Note: In accordance with 10 CFR 75.11, any change in facility operations or processes that would result in any changes in, additions to, or deletions from the list should be communicated to the NRC in writing, to the extent provided in the license conditions, at least 70 days in advance of the changes so that new composition codes can be assigned.
26i.
OWNER CODEThis code identifies the ownership of the material at the time it was in the shippers possession. Enter the appropriate code from the following.
G U.S. Government-owned J
Not U.S. Government-owned Refer to the glossary in Appendix D to this document for further description of U.S. Government-owned material.
26j.
KEY MEASUREMENT POINT (KMP)This data element applies only to licensees reporting pursuant to the requirements of 10 CFR Part 75. All other licensees must leave this block blank. This block is for reporting on a facility where nuclear material is in a form that may be measured to determine material flow or inventory. Codes for KMPs are identified in the FAs or TFAs developed for those facilities described in the instructions for block 26h.
26k.
MEASUREMENT IDENTIFICATION (see 26j)This block applies only to licensees reporting pursuant to the requirements of 10 CFR Part 75 and to those facilities identified in the instructions for 26h. All other licensees must leave this block blank. This block indicates where and when the material was measured. It consists of three parts.
26k1. BASISEnter the pertinent code from the following:
N if the batch data are based on measurements made in an IAEA material balance area (MBA) other than the reporting MBA L
if the batch data are based on measurements made in another IAEA MBA and have been previously reported by the reporting MBA in a DOE/NRC Form 741 or a DOE/NRC Form 742C, Physical Inventory Listing M
if the batch data are based on measurements made in the reporting IAEA MBA and the data were not previously reported T
if the batch data are based on measurements in the reporting IAEA MBA and have been previously reported for that MBA on a DOE/NRC Form 741 or a DOE/NRC Form 742C 26k2. OTHER MEASUREMENT POINT (OMP)For batch data designated code M in block 26k1, enter the code of the KMP where measurements were made if it is different from the KMP indicated in block 26j. If it is the same, leave the block blank.
NUREG/BR-0006, Rev. 8 16 26k3. MEASUREMENT METHODIf two or more measurement methods employed at the same KMP have a different measurement uncertainty, enter the code for the measurement method used, as identified in the FA.
26l.
GROSS WEIGHTEnter the gross weight of the line entry in kilograms of material shipped plus tare weight (packaging and shipping container).
26m. NET WEIGHTEnter the weight of the material shipped, excluding tare weight, in grams for SNM and kilograms for source material.
26n.
ELEMENT WEIGHTEnter the weight of the contained SNM or source material rounded to the quantities reported below.
Material Reporting Units Plutonium or uranium enriched in U235 or U233 nearest whole gram Pu238 nearest 1/10 gram Source material nearest kilogram4 If the quantity to be entered is equal to or greater than 0.5 of the reporting unit, the quantity should be rounded up to the next whole reporting unit. If the quantity to be entered is less than 0.5 of the reporting unit, the quantity should be rounded down to the next whole reporting unit.
26o.
ELEMENT LIMIT OF ERRORLimits of error need be reported only by licensees who are authorized to possess at any time and location SNM in a quantity exceeding 1 effective kilogram and authorized to use SNM for activities other than those involved in the operation of a nuclear reactor licensed pursuant to 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities; who are involved in a waste disposal operation; or who are authorized to possess sealed sources.
Complete when the total shipment contains more than 50 grams of U235, U233, or plutonium, or any combination of these. Enter the limit of error for each element entry using the same weight units as in block 26n, except where the line entry represents (1) a sealed plutonium-beryllium source, (2) samples that have all been determined by other means to contain less than 10 grams U235, U233, or plutonium, and (3) reactor-irradiated 4
Optionally, if the reporter is using XML format, source material may be reported to three decimal places.
When using three-decimal reporting to report source material, then the reporting unit is to the nearest thousandth of a kilogram (i.e., 1655 grams will be reported as 1.655 kilograms).
17 NUREG/BR-0006, Rev. 8 fuels involved in research, development, and evaluation programs in facilities other than irradiated-fuel reprocessing plants.
Limits of error are to be at the 95-percent confidence level, propagated by the uncertainties of the weight measurement, the chemical analysis, and the sampling method. Limits of error are not applicable to source material. Licensees making onsite transfers between two different RISs or within the same RIS are exempt from supplying limits of error data for the transfers. Transfers between a license-exempt operation and a licensed operation at the same location are not considered onsite transfers, and limits of error are required.
26p.
WEIGHT % ISOTOPEEnter the weight percent of the isotope U235 if the uranium is enriched or depleted in U235. If plutonium, enter the weight percent of the isotope Pu240.
If Pu238, enter the weight percent of the isotope Pu238. Report weight percent to at least two, but not more than four, decimal places, depending on the accuracy of the measurement method employed (for example, XX.XXXX%). For U233, enter the parts per million of U232. This block does not apply to natural uranium and thorium. Use separate lines to report material of different enrichments. The plutonium and U235 content of irradiated fuel must be determined and reported upon removal of the spent fuel from the reactor core. Reactor operators may report the total nonfissile isotope instead of Pu240 in this block for spent fuel if the computer codes the operator uses have this limitation.
26q.
ISOTOPE WEIGHTEnter the isotope weight. If enriched uranium or U233, enter weight to the nearest gram of U235 or U233 as appropriate. If plutonium, enter the sum of Pu239 and Pu241 to the nearest gram. If Pu238, enter the weight of the isotope Pu238 to the nearest one-tenth of a gram. For depleted uranium, enter the isotope weight to the nearest kilogram. Make no entry for other source material.
If the quantity to be entered is equal to or greater than 0.5 of the reporting unit, the quantity should be rounded up to the next whole reporting unit. If the quantity to be entered is less than 0.5 of the reporting unit, the quantity should be rounded down to the next whole reporting unit.
26r.
ISOTOPE LIMIT OF ERRORLimits of error need be reported only by licensees who are authorized to possess at any one time and location SNM in a quantity exceeding 1 effective kilogram and authorized to use such SNM for activities other than those involved in the operation of a nuclear reactor licensed pursuant to 10 CFR Part 50, who are involved in a waste disposal operation, or who are authorized to possess sealed sources.
Complete when the total shipment contains more than 50 grams of U235, U233, or plutonium, or any combination of these. Enter the limit of error for each isotope entry using the same weight units as in block 26n, except where the line entry represents (1) a sealed plutonium-beryllium source, (2) samples that have all been determined by other means to contain less than 10 grams U235, U233, or plutonium, and (3) reactor-irradiated fuels involved in research, development, and evaluation programs in facilities other than irradiated-fuel reprocessing plants.
NUREG/BR-0006, Rev. 8 18 Limits of error are to be at the 95-percent confidence level, propagated by the uncertainties of the weight measurement, the chemical analysis, and the sampling method. Limits of error are not applicable to source material. Licensees making onsite transfers between two different RISs or within the same RIS are exempt from supplying limits of error data for the transfers. Transfers between a license-exempt operation and a licensed operation at the same location are not considered onsite transfers, and limits of error are required.
26s.
SIGNATURE OF AUTHORIZED OFFICIAL AND DATE SIGNEDIf submitted on paper, the report must be signed by an authorized representative of the licensee. Otherwise, enter the date submitted. Each licensee must establish internal procedures to ensure that the information provided in the report is accurate and that the report has been prepared and issued only by authorized licensee personnel.
Proprietary information must be included when necessary to provide an adequate response. An application to withhold such information from public disclosure may be made and will be dispositioned in accordance with the provisions of 10 CFR 2.390. If any of this information is of particular sensitivity, a request may be made that such information not be transmitted to IAEA. Such a request must refer to and conform with 10 CFR 75.12, Communication of Information to IAEA.
2.1.2 Reporting Receivers Data Each receiver of reportable quantities of SNM or source material must acknowledge receipt of shipments in accordance with the following instructions:
If the receiver plans to accept the shippers measurement data without making independent measurements (B action code), the receiver must, within 10 days of receipt of the material, submit a DOE/NRC Form 741. There are two options for filling out the form:
(1)
Complete blocks 1 through 25 and enter a zero (0) in block 10.
(2)
Complete blocks 1 through 25, enter the shippers values in block 26, and repeat the shipper=s values in block 27.
Facilities reporting pursuant to 10 CFR Part 75 must use the second option. They should dispatch the form in accordance with the instructions in Section 2.3.2.
If the receiver makes independent measurements (E action code), the receiver must do the following within 10 days of receipt of the material:
(1)
Complete blocks 1 through 25, enter the shippers values in block 26, and complete blocks 27a through 27s of DOE/NRC Form 741.
Dispatch the form in accordance with the instructions in Section 2.3
19 NUREG/BR-0006, Rev. 8 If the receiver intends to make independent measurements within 60 days for source material or LEU, or 45 days for HEU (N action code), unless the NRC authorizes an exemption, the receiver shall do the following, within 10 days of receipt of the material:
(1)
Complete blocks 1 through 23 (2)
Dispatch the form in accordance with the instructions in Section 2.3.2.
(3)
After independent measurements are made, follow the instructions for reporting a B or E action code. If measurements are delayed, complete them and report them on DOE/NRC Form 741 within 60 days for source material and LEU and within 45 days for HEU after the receipt of each shipment, except in the case of receipts of scrap and irradiated material.
In the case of a scrap processor receiving several shipments of scrap that are accumulated and processed together, the recovered quantity of material must be prorated to the specific transmittal documents and line entries to maintain the one-to-one correspondence between shippers and receivers data.
- 27.
RECEIVERS DATAFill in the receivers data blocks as follows.
Enter shipper and receiver measurement data on DOE/NRC Form 741 for each batch of material. For licensees reporting pursuant to 10 CFR Part 75 requirements or if the transfer is an import or an export, a batch is a portion of nuclear material that is handled as a unit for accounting purposes at a KMP and whose composition and quantity are defined by a single set of specifications or measurements. The batch may be in bulk form or contained in a number of separate items. If the shipment is an export or is being reported pursuant to 10 CFR Part 75, list fuel assemblies or loose rods or fuel pins separately with the identifying label serving as a unique batch name. Report fuel assemblies as average enrichment as long as the appropriate accounts (material types 10, 20, 81, etc.) are properly adjusted. Material being transferred may be listed on one line of DOE/NRC Form 741 if the material is all of the same material type, composition, ownership, and weight percent of isotope (except as noted in the next paragraph). List material differing in any of these data elements on separate lines.
Two or more lines may be necessary to describe a single batch (e.g., spent fuel assemblies, mixed-oxide fuel). If a batch consists of several types of nuclear material, use several consecutive lines to describe the batch. Repeat the batch name on all lines used to describe a single batch. In block 27e, also repeat the number of items on all lines with the same batch name.
The above general rules for grouping or batching material for reporting purposes also apply to licensees reporting imports or exports pursuant to 10 CFR Part 40 or 10 CFR Part 74. Batch names are optional for other transactions reported pursuant to 10 CFR Part 40 or 10 CFR Part 74.
27a.
BACK REFERENCE NUMBERMust match the shippers value. See 26a.
27b.
LINE NUMBERMust match the shippers value. See 26b.
NUREG/BR-0006, Rev. 8 20 27c.
TYPE OF INVENTORY CHANGEMust match the shippers value. See 26c.
27d.
IDENTIFICATION (ITEM/BATCH NAME)See 26d.
27e.
NO. OF ITEMSSee 26e.
27f.
PROJECT NUMBERSee 26f.
27g.
MATERIAL TYPEMust match the shippers value. See 26g.
27h.
COMPOSITION/FACILITY CODESee 26h.
27i.
OWNER CODEDescribes the material ownership at the time it comes into the receivers possession. See 26i.
27j.
KEY MEASUREMENT POINTSee 26j.
27k.
MEASUREMENT IDENTIFICATIONSee 26k.
27l.
GROSS WEIGHTSee 26l.
27m. NET WEIGHTSee 26m.
27n.
ELEMENT WEIGHTSee 26n.
27o.
ELEMENT LIMIT OF ERRORSee 26o.
27p.
WEIGHT % ISOTOPESee 26p.
27q.
ISOTOPE WEIGHTSee 26q.
27r.
ISOTOPE LIMIT OF ERRORSee 26r.
27s.
SIGNATURE OF AUTHORIZED OFFICIAL AND DATE SIGNEDSee 26s.
2.2 Preparation of DOE/NRC Form 741 in Computer-Readable Format NMMSS Report D-24 provides instructions for preparing DOE/NRC Form 741 in computer-readable format as required for submittals.
2.3 Distribution of DOE/NRC Form 741 2.3.1 Shipper Each shipper of reportable quantities of SNM or source material must dispatch a DOE/NRC Form 741, as described below, no later than the close of business the next working day after the shipment. In the case of spent fuel shipments, in accordance with 10 CFR 73.37, the date of shipment is Safeguards Information until 10 days after the shipment or the last shipment in a
21 NUREG/BR-0006, Rev. 8 series of shipments is received. Therefore, the DOE/NRC Form 741 should be identified as Safeguards Information and handled according to 10 CFR 73.21.
When submitting Safeguards Information, a Concise Note Form 740M must be submitted stating that the submission is Safeguards Information and should be handled in accordance with 10 CFR 73.21.
Burials are reported when shipped. The burial site operator must prepare a DOE/NRC Form 741 and transmit it to the NMMSS to document receipt and disposal.
The completed DOE/NRC Form 741 is distributed as follows:
Provide a copy, in a mutually agreeable format, to the other party in the transaction.
Submit one copy in computer-readable format to the NMMSS. See Section 1.5 for documentation and distribution of classified and unclassified reports.
Retain one copy for the file.
2.3.2 Receiver The receiver should distribute the completed DOE/NRC Form 741 as follows:
Submit one copy in computer-readable format to the NMMSS. See Section 1.5 for documentation and distribution of classified and unclassified reports.
Return one copy, in a mutually agreeable format, to the shipper.
Retain one copy for the file.
23 NUREG/BR-0006, Rev. 8 3 INSTRUCTIONS FOR ONSITE GAINS AND LOSSES (M ACTION CODE) 3.1 Instructions for Completing DOE/NRC Form 741 When using action code M, the licensee should complete DOE/NRC Form 741 in accordance with the following instructions:
- 1.
SHIPPERS RISEnter the RIS.
- 2.
RECEIVERS RISSame as in block 1.
- 3.
TRANSACTION NUMBERSee the instructions for block 3 in Section 2.1.1 or contact the NMMSS operator for other options.
- 4.
CORRECTION NUMBERSee the instructions for block 4 in Section 2.1.1.
- 5.
PROCESSING CODESee the instructions for block 5 in Section 2.1.1.
- 6.
ACTION CODEEnter M in 6a or 6b or both.
- 7.
DOCUMENTATIONEnter the number of pages if the submission is classified. This block is for paper-copy submissions only.
- 8.
NAME AND ADDRESS OF SHIPPERLeave blank.
- 9.
NAME AND ADDRESS OF RECEIVERLeave blank.
- 10.
NUMBER OF DATA LINESEnter the total number of detail line entries on the form.
- 11.
NATURE OF TRANSACTIONLeave blank.
- 12.
SHIPPED FOR ACCOUNT OFLeave blank.
- 13.
SHIPPED TO ACCOUNT OFLeave blank.
- 14.
TRANSFER AUTHORITYLeave blank.
- 15.
EXPORT OR IMPORT TRANSFERSLeave blank.
- 16.
MATERIAL TYPE AND DESCRIPTIONLeave blank.
- 17.
LINE NUMBERSee the instructions in Section 2.1.1 for block 17.
- 18.
COUNTRY OF OBLIGATIONSee the instructions in Section 2.1.1 for block 18.
- 19.
MATERIAL TYPESee the instructions in Section 2.1.1 for block 19.
NUREG/BR-0006, Rev. 8 24
- 20.
OBLIGATED ELEMENT WEIGHTSee the instructions in Section 2.1.1 for block 20.
- 21.
OBLIGATED ISOTOPE WEIGHTFOR ENRICHED URANIUM ONLYSee the instructions in Section 2.1.1 for block 21.
- 22.
ACTION DATEEnter the date of the activity in at least one of blocks 22a through 22e.
If more than one block is completed, all dates must be the same.
- 23.
MISCELLANEOUSLeave blank.
- 24.
TOTAL GROSS WEIGHTLeave blank.
- 25.
TOTAL VOLUMELeave blank.
- 26.
SHIPPERS DATA 26a.
BACK REFERENCE NUMBERSee the instructions in Section 2.1.1 for this block.
26b.
LINE NO.See the instructions in Section 2.1.1 for this block.
26c.
TYPE OF INVENTORY CHANGESee Section 2.1.1.
26d.
IDENTIFICATION (ITEM/BATCH NAME)See Section 2.1.1.
26e.
NO. OF ITEMSSee Section 2.1.1.
26f.
PROJECT NUMBERLeave blank.
26g.
MATERIAL TYPESee Section 2.1.1.
26h.
COMPOSITION/FACILITY CODESee Section 2.1.1.
26i.
OWNER CODESee Section 2.1.1.
26j.
KEY MEASUREMENT POINTSee Section 2.1.1.
26k.
MEASUREMENT IDENTIFICATIONSee Section 2.1.1.
26l.
GROSS WEIGHTSee Section 2.1.1.
26m. NET WEIGHTSee Section 2.1.1.
25 NUREG/BR-0006, Rev. 8 26n.
ELEMENT WEIGHTSee Section 2.1.1.
26o.
ELEMENT LIMIT OF ERRORSee Section 2.1.1.
26p.
WEIGHT % ISOTOPELeave blank for ICT codes MF and EQ unless the material is enriched uranium. For ICT codes LN and TN, report the same weight percent of isotope as for the beginning of the inventory period. See the instructions in Section 2.1.1 for this block.
26q.
ISOTOPE WEIGHTSee Section 2.1.1.
26r.
ISOTOPE LIMIT OF ERRORLeave blank.
26s.
SIGNATURE OF AUTHORIZED OFFICIAL AND DATE SIGNEDSee Section 2.1.1.
- 27.
RECEIVERS DATASee the instructions in Section 2.1.2 for block 27.
3.2 Preparation of DOE/NRC Form 741 in Computer-Readable Format NMMSS Report D-24 provides instructions for preparing DOE/NRC Form 741 in computer-readable format as required for submittals.
3.3 Distribution of DOE/NRC Form 741 Distribution of the completed DOE/NRC Form 741 should be as follows:
Submit one copy in computer-readable format to the NMMSS. (See Section 1.5 for documentation and distribution of classified and unclassified reports.)
Retain one copy for the file.
27 NUREG/BR-0006, Rev. 8 4 INSTRUCTIONS FOR CORRECTING A DOE/NRC FORM 741 (C, D, AND M ACTION CODES OR Z PROCESS CODE)
Adjustments are independent actions. Either the shipper or the receiver may initiate an adjustment to a DOE/NRC Form 741 reporting the original shipment or receipt of material or an adjustment to any previous adjustment to the original. The other party is required to acknowledge that an adjustment was made but not required to make the same adjustment to its records.
4.1 Originator The originator of the corrected copy must do the following:
Complete blocks 1 through 25, as appropriate, referring to the copy of DOE/NRC Form 741 being corrected.
Insert in block 26a or 27a of the did-read (Was) line, as appropriate, a back-reference code. If the line of data has not been previously corrected, use a zero (0). If previously corrected, the first digit is the correction number (block 4) from the DOE/NRC Form 741 being corrected. If the line of data has been corrected several times, use the most recent correction number. The next two digits are the line number (block 26b or 27b) on the DOE/NRC Form 741 being corrected. The did-read line can only reference a line on the original document or a should-read line. No two or more did-read lines can back-reference the same line.
Complete the did-read line, blocks 26b through j and n through r or 27b through j and n through r, as appropriate, by duplicating the entire line being corrected from the DOE/NRC Form 741 being corrected and indicating the opposite sign (positive or negative) from the original one used in reporting the number of items (block e), element weight (block n), element limit of error (block o), isotope weight (block q), and isotope limit of error (block r).
Insert in block 26a or 27a of the should-read (Should-Be) line, as appropriate, a back-reference code that references the corresponding did-read line. The first digit is the correction number of the document being completed. The next two digits are the line number of the corresponding did-read line. The should-read line can only reference a did-read line. No two or more should-read lines can back-reference the same line.
Repeat this procedure until all lines requiring adjustment have been backed out and the correct information has been entered.
The did-read and should-read for each line being adjusted should be paired (i.e., consecutive).
One or more changes can be made to each line. Only incorrect lines should be included in a correction report.
NUREG/BR-0006, Rev. 8 28 If adding a line to the original document, the back-reference should be (000) (block 26a or 27a),
and pairing is not done.
If a line previously reported is split into two or more lines, one of the should-be lines should back-reference the did-read line, and all others should be considered new additions (000).
If a line is to be voided, use only a did-read line (no pairing). Appendix C provides examples of an initial report and subsequent correction reports.
4.2 Receiver Within 10 days, the facility receiving the corrected DOE/NRC Form 741 must do one of the following:
Submit a DOE/NRC Form 741 acknowledging the adjustment (which will close a transaction but will not affect the acknowledging party=s values).
Submit a DOE/NRC Form 741 accepting the adjustment or reporting the facilitys own adjustment. This closes a transaction and applies the accepted or reported adjustment to the acknowledging party=s values.
There is no requirement for both parties to make the same quantity adjustments. However, if both parties choose to adjust on the same corrected DOE/NRC Form 741, they must both report the same number of entries, and the material types must agree line for line.
4.3 Use of the Z Process Code If the receiving party agrees to all changes for an action code C document, the receiving party may use process code Z and action code D. A DOE/NRC Form 741 should be used to report data in blocks 1, 2, 3, 4, and 22. The Z code should be entered in block 5b and action code D entered in block 6b, and block 22 should be completed. A licensee reporting pursuant to 10 CFR Part 75 may not use the Z process code.
4.4 Distribution of Corrections to DOE/NRC Form 741 The originator should do the following:
Submit one copy, in a mutually agreeable format, to the other party in the transaction.
Submit one copy in computer-readable format to the NMMSS. (See Section 1.5 for documentation and distribution of classified and unclassified reports.)
Retain one copy for the originating facilitys file.
Upon receipt of a correction, a licensee should distribute a completed DOE/NRC Form 741 reporting an acknowledgment, acceptance, or correction as follows:
29 NUREG/BR-0006, Rev. 8 Submit one copy to the NMMSS. (See Section 1.5 for documentation and distribution of classified and unclassified reports.)
Return one copy to the originator.
Retain one copy for the facilitys file.
31 NUREG/BR-0006, Rev. 8 5 INSTRUCTIONS FOR COMPLETING DOE/NRC FORM 740M These instructions apply to all licensees who have been notified by letter from the NRC, as provided in 10 CFR 75.11, that their installations have been identified under the U.S./IAEA Safeguards Agreement. FAs or TFAs for such installations may specify circumstances under which concise notes must be submitted to the IAEA as attachments to other reports. These facilities should use DOE/NRC Form 740M to explain to the foreign state where the IAEA-required data items appear.
Licensees who are reporting what is determined to be Safeguards Information must submit a concise note, as discussed in Section 1.5.
These instructions also apply to importers who for any reason cannot use the same batch name as the shipper. If the shipper fails to supply a batch name, the importer should supply a batch name and attach a concise note to that effect.
In some cases, it may be desirable to provide additional explanatory information with reports.
DOE/NRC Form 740M is used to submit this information. A DOE/NRC Form 740M may be attached to DOE/NRC Form 741, to DOE/NRC Form 742, to DOE/NRC Form 742C, or to a standalone concise note for facilities reporting under 10 CFR Part 75.
The numbered blocks of DOE/NRC Form 740M should be completed as follows:
- 1.
NAME AND ADDRESSLeave blank.
- 2.
ATTACHMENT TOPlace an X in the appropriate box to indicate that this explanatory information will be attached to a DOE/NRC Form 741 When attaching the concise note to DOE/NRC Form 742 or 742C, enter the number 1 for the first concise note attached to the particular DOE/NRC Form 742 or 742C. When issuing an additional concise note for a particular DOE/NRC Form 742 or 742C, enter the next sequential number (2-9) of the concise note.
- 3.
RISEnter the RIS to which the explanatory information in this report applies.
- 4.
REPORTING PERIODComplete this block only when the concise note is attached to a DOE/NRC Form 742 or a DOE/NRC Form 742C. Enter the beginning and ending dates of the reporting period as shown on Form 742
NUREG/BR-0006, Rev. 8 32
- 5.
TRANSACTION DATAComplete this block only when the concise note is attached to a DOE/NRC Form 741 or if a standalone concise note is submitted. Copy the requested data from DOE/NRC Form 741. All entries in this block must be identical to those on DOE/NRC Form 741. Fill in the blocks as follows.
5A.
SHIPPER=S RISEnter the RIS of the shipper.
5B.
RECEIVER=S RISEnter the RIS of the receiver.
5C.
TRANSACTION NUMBEREnter the unique transaction number.
5D.
CORRECTION NUMBERIf the DOE/NRC Form 741 is a correction to a previous report, enter the correction number.
5E.
PROCESSING CODEInsert the same code used in DOE/NRC Form 741.
5F.
ACTION CODEIf a Form 740M is used with a DOE/NRC Form 741, enter the same action code as on the DOE/NRC Form 741, block 7; otherwise, enter action code M.
- 6.
REPORTING DATEComplete this block if the concise note is attached to a DOE/NRC Form 741 or 742C. Copy the date shown on DOE/NRC Form 741 or 742C.
- 7.
This block contains the actual explanatory data and other data necessary to link the explanatory data to the part or parts of the report to which the data apply. Complete this block as follows.
7A.
LINE NO.Enter consecutive numbers beginning with 1 for each explanatory reference.
7B.
ENTRY REFERENCEIf the explanatory information entered on this line of the DOE/NRC Form 740M applies to the entire DOE/NRC Form 741, 742, or 742C, enter WHOLE REPORT. If the explanation applies to the data on a specific batch on a DOE/NRC Form 741 or 742C, copy the batch name exactly as it appears on the DOE/NRC Form 741 or 742C. If the explanation applies to a specific material balance category on a DOE/NRC Form 742, enter the two-digit number of the material balance category. Additionally, if the explanation applies to material balance categories 11, 30, 42, 43, or 51, enter the RIS shown on the relevant line of DOE/NRC Form 742. If the explanation applies to categories 22 or 71, enter the two-character ICT as shown on the relevant line of DOE/NRC Form 742. If the DOE/NRC Form 740M action code is M, enter GENERAL.
7C.
TEXT OF CONCISE NOTEEnter any 43 letters, numbers, or special characters per line. Up to 99 lines of text may be used for any one explanation.
33 NUREG/BR-0006, Rev. 8
- 8.
SIGNATUREAn authorized representative of the licensee must sign DOE/NRC Form 740M. See the instructions in Section 2.1.1 for block 26s.
- 9.
TITLEEnter the title of the person signing the form.
- 10.
DATEEnter the date the form is signed.
DOE/NRC Form 740M should be put into computer-readable format following the additional guidance in NMMSS Report D-24.
Copies of Form 740M must be attached to, and distributed with, the DOE/NRC Form 741, 742, or 742C to which the DOE/NRC Form 740M applies.
35 NUREG/BR-0006, Rev. 8 6 DOE REPORTING REQUIREMENTS FOR PROPRIETARY INTERESTS OF THE GOVERNMENT NRC licensees are responsible for routinely reporting to the NMMSS all DOE-owned, -loaned, or -leased material in their possession as prescribed in DOE Orders Series 470 (DOE Order 470.4 and DOE M 470.4-6).
37 NUREG/BR-0006, Rev. 8 7 REFERENCES This report and its appendices reference the NMMSS documents listed below. To request these documents, telephone the NMMSS operator.
NMMSS Report D-2, The DOE Directory of Reporting Identification Symbols NMMSS Report D-3, The NRC Directory of Reporting Identification Symbols NMMSS Report D-15, International Nuclear Facilities Codes Manual NMMSS Report D-24, Personal Computer Data Input for NRC Licensees NMMSS Report D-25, Transaction Composition Code Reference List American National Standards Institute Report D-50A-109, ANSI Codes
APPENDIX A COMPOSITION CODES
NUREG/BR-0006, Rev. 8 A-1 COMPOSITION CODES The codes listed below are for use in completing blocks 26h or 27h on DOE/NRC Form 741, Nuclear Material Transaction Reports. If an installation has been notified by letter from the U.S. Nuclear Regulatory Commission (NRC), as provided in Title 10, Section 75.11, Installation Information, of the Code of Federal Regulations (10 CFR 75.11), that it has been identified under the U.S./International Atomic Energy Agency Safeguards Agreement, the licensee should enter the appropriate code from the list developed during the formulation and negotiation of the facility attachment or transitional facility attachment (after the document has been provided under 10 CFR 75.8, Facility Attachments).
In accordance with 10 CFR 75.11, any change in facility operations or processes that would result in any changes to, additions to, or deletions from the list should be communicated to the NRC in writing, to the extent provided in the facilitys license conditions, at least 70 days in advance of the changes so that new composition codes can be assigned.
For additional composition codes, see Nuclear Materials Management and Safeguards System (NMMSS) Report D-25, Transaction Composition Code Reference List, and American National Standards Institute (ANSI) Report D-50A-109, ANSI Codes.
UNENCAPSULATED (except scrap)
Code 032 U3O8 (oxide product) 048 UO3 (trioxide product) 770 Carbides 455 Other Oxides Product (for all oxides not otherwise identified) 064 Tetrafluorides (tetrafluoride product) 083 UF6 (hexafluoride product) 095 Enriching Process 102 Hexafluoridesin Enriching Process 103 Hexafluoride Product 107 Uranium in CascadesHoldup 120 UF6 Feed 773 UF6 Heels
NUREG/BR-0006, Rev. 8 A-2 363 In Reactor Product 409 Nitrate Solutions Product 786 Acetate Solutions Product 701 Unalloyed Metal Product 702 Alloyed Metal Product 771 Samples and Standards 637 Sintered Products UNENCAPSULATED SCRAP (for recovery)* +
375 Irradiated Recyclable Fuel WASTE (for disposal)
Waste material should be described by an appropriate scrap category.*
ENCAPSULATED 291 Fabricated Fuel Elements (pins, rods, plates) 309 Fuel Assemblies (assembled items product) 481 Sealed Sources (fabricated sources product)
OTHER 776 Other Products E04 Miscellaneous Noncombustibles (Uranium)
Note: Uranium/thorium and plutonium/uranium mixed-oxide fuels should be reported either as fuel elements (code 291) or as fuel assemblies (code 309) as applicable.
Report the different material types in the mixed-oxide fuels on separate lines.
ANSI codes for plutonium scrap may be used in lieu of these codes.
+
Where a number of dissimilar items of scrap are put into the same container, use the composition code for the predominant scrap category.
APPENDIX B INVENTORY CHANGE TYPE CODES FOR COMPLETING BLOCKS 26c AND 27c OF DOE/NRC FORM 741
NUREG/BR-0006, Rev. 8 B-1 INVENTORY CHANGE TYPE CODES FOR COMPLETING BLOCKS 26c AND 27C OF DOE/NRC FORM 741 All inventory change type codes on transaction reports consist of two alphabetic or numeric characters. The accounting entry type codes used on material balance reports (MBRs) consist of two digits. In the following pages, the number(s) in parentheses following the alphabetic code represent the MBR line to which the transaction entries correspond. The standard inventory changes and other entry types are listed below. In transaction reports, all transactions and operations are understood to be related to individual batches. In MBRs, corresponding the same codes denote consolidated entries (i.e., the sums of all individual operations with the same code over the material balance period). In addition, MBRs include entries related to inventory data and adjustments not reported on transaction reports.
Gains or losses of material that occur based on the total inventory, or in which individual effects to inventories by country of obligation code cannot be determined, should be reported as a loss to all country obligation balances by applying a one to one ratio by percent of the country of obligation to the amount of inventory affected to the amount of inventory change. For example, if decay is reported for plutonium within a reactor and the plutonium balance represents several different country of obligation balances, the following calculations would determine the amount of decay to apply to each country of obligation code balance.
Element Isotope Amount of inventory for which decay applies 1,202,239 950,947 Calculated decay for the period 998 998 Balance by Country Obligation Code OBLIGATION CODE ELEMENT ISOTOPE
% Ratio to Total Inventory 33 200,000 158,196 200,000/1,202,239 =.166 x 100 = 17%
34 509,321 402,863 509,321/1,202,239 =.424 x 100 = 42%
32 492,918 389,888 492,918/1,202,239 =.410 x 100 = 41%
Total Pu Balance 1,202,239 950,947 100%
Amount of decay to apply to each country of obligation code balance 33 998 x 17% = 169.66 rounded to the nearest gram = 170 34 998 x 42% = 419.16 rounded to the nearest gram = 419 32 998 x 41% = 409.18 rounded to the nearest gram = 409 998 The following should also be used for the isotope balances:
NUREG/BR-0006, Rev. 8 B-2 TRANS. MBR CODE LINE EXPLANATION REQUIREMENT FOR BLOCKS 26c AND 27c RF (11, 13, 30, 38, 39)
Nuclear material imported into the United States (receipt foreign).
Make no entry RD (11, 13, 30, 38, 39)
Domestic receipt of nuclear material from another domestic reporting identification symbol (RIS) (receipt domestic).
Make no entry RN (11, 13, 30, 38, 39)
Domestic receipt of nuclear material from activity not subject to 10 CFR Part 75.
Make no entry NP (21)
Production of fissionable material in a reactor (Pu, U233).
Entry required by licensee DU (76)
Reapplication of safeguards in nuclear material previously exempted therefrom pursuant to Article 38 of the US/IAEA Safeguards Agreement after being exempted based on use (licensees subject to 10 CFR Part 75 only).
Entry required only after notification by the NRC DQ (76)
Reapplication of safeguards in nuclear material previously exempted therefrom pursuant to Article 38 of the Agreement after being exempted based on quantity (licensees subject to 10 CFR Part 75 only).
Entry required only after notification by the NRC SF (42, 43, 51, 58, 59)
Export of nuclear material out of the United States.
Make no entry SD (42, 43, 51, 58, 59)
Domestic transfer of nuclear material from another domestic RIS.
Make no entry SN (42, 43, 51, 58, 59)
Domestic transfer of nuclear material from a facility subject to 10 CFR Part 75 to a waste management facility.
Entry required SN (42, 43, 51, 58, 59)
Domestic transfer of nuclear material from a facility subject to 10 CFR Part 75 to a facility other than a waste management facility.
Make no entry LN*
Consumption of nuclear material because of its Entry required by (73) transformation into other elements or licensee isotope(s) as a result of nuclear reactions (burnup).
- Note: When calculating weight percent isotope in the case of burnup or decay, report the same weight percent isotope for decay and burnup as the weight percent of the beginning
NUREG/BR-0006, Rev. 8 B-3 TRANS. MBR CODE LINE EXPLANATION REQUIREMENT FOR BLOCKS 26c AND 27c inventory for the period.
TN*
Consumption of nuclear material because of Entry required by (72) transformation into other elements or licensee isotope(s) as a result of nuclear reactions (decay).
- Note: When calculating weight percent isotope in the case of burnup or decay, report the same weight percent isotope for decay and burnup as the weight percent isotope of the original inventory for the period.
LD (74)
Normal operational loss/measured discard; (i.e., loss of a measured or estimated (on the basis of measurement) quantity of nuclear material from processing which has been disposed of in such a way that it is not suitable for further nuclear use).
Entry required by licensee TW (74)
Transfer to the retained waste category of measured nuclear material which is deemed to be irrecoverable, to be stored at the material balance area (MBA) and to be deleted from the inventory of the MBA.
Entry required by licensee FW (51)
Retransfer of material that has been stored at the MBA as retained waste to the nuclear material inventory. This applies whenever material in the retained waste category is removed from storage either for processing at the MBA or for retransfer from the MBA.
Entry required by licensee EU (76)
Exemption of nuclear material from safeguards pursuant to Article 36 of the Agreement (licensees subject to 10 CFR Part 75 only).
Entry required only after notification by the NRC EQ (76)
Exemption of nuclear material from safeguards pursuant to Article 37 of the Agreement (licensees subject to 10 CFR Part 75 only).
Entry required only after notification by the NRC TU (76)
Termination of safeguards on nuclear material pursuant to Articles 13 and 35 of the Agreement (licensees subject to 10 CFR Part 75 only).
Entry required only after notification by the NRC LA (75)
Entry required by licensee
NUREG/BR-0006, Rev. 8 B-4 TRANS. MBR CODE LINE EXPLANATION REQUIREMENT FOR BLOCKS 26c AND 27c Irretrievable and inadvertent loss of a known quantity of nuclear material as the result of an operational accident.
GA (75)
Nuclear material unexpectedly found to be present in the MBA, except when detected in the course of a physical inventory taking.
Gains should be reported as a negative value.
Entry required by licensee DI (N/A)
The difference between the batch quantity reported as received (always on shipper=s data) and the quantity of the same batch as measured by the operator of the receiving MBA (licensees subject to 10 CFR Part 75 only).
Make no entry RM (N/A)
The quantity by which the batch mentioned in the entry is diminished in cases of rebatching (licensees subject to 10 CFR Part 75 only).
Licensee entry required, if applicable RP (N/A)
The quantity of material added from another batch to the batch mentioned in the entry (licensees subject to 10 CFR Part 75 only).
Licensee entry required, if applicable EN ED NE ND DE DN EE (22, 71)
(22, 71)
Category ChangeThe quantity of uranium that has changed category as a result of blending, enrichment, depletion, or burnup.
The first letter denotes the original, the second letter the resulting category (E=enriched, N=natural (or normal), D=depleted uranium, EE=change of enrichment). The material type codes should be those for both the original and the resulting material. The weight data should be provided both for the originating and for the resulting category.
These entries should be consolidated into the material balances for both categories. For any of these changes, line pairing is required; one line denotes the original material and the other denotes the resulting material.
Enrichment facility may use the 22, 71 combination to report changes in material type associated with enrichment activities for Entry required by licensee
NUREG/BR-0006, Rev. 8 B-5 TRANS. MBR CODE LINE EXPLANATION REQUIREMENT FOR BLOCKS 26c AND 27c material types 10, 20, 81, and 89 or proceed as directed by the NRC.
MF (77)
Inventory DifferenceThis should be calculated as the difference between the book inventory and the ending physical inventory.
Reactors must not use this code.
Entry required by licensee PB (N/A)
Beginning Physical InventoryThis should be equal to the ending physical inventory of the previous MBR relating to the same material.
Entry required by licensee BA (83)
The algebraic sum of the beginning physical inventory and of the inventory changes over the period, adjusted to take account of the shipper-receiver differences.
Entry required by licensee PE (N/A)
The sum of all measured and derived batch quantities of nuclear material on hand on the date of the physical inventory taking.
These entries should be consolidated.
Entry required by licensee RAXX (N/A)
Applicable to licensees subject to 10 CFR Part 75 only. The quantity that must be added to the rounded sum to make it equal to the sum of the rounded terms. A rounding adjustment (RA) is made to an entry in the MBR of which the International Atomic Energy Agency (IAEA) has been informed differently through inventory change reports (ICRs) and physical inventory lists, in order to bring the MBR entry into agreement with the corresponding figures established on the basis of ICRs and physical inventory lists. In the case of the book inventory and the inventory difference (ID) or material unaccounted for (MF), the following formulas should be used respectively:
RABA = PB + ICRMBR B DI B BA, and RAMF = BA B PE B MF where ICRMBR is the sum of the consolidated inventory changes as reported in the MBR, taken with the appropriate sign if they Entry by licensee required only if applicable
NUREG/BR-0006, Rev. 8 B-6 TRANS. MBR CODE LINE EXPLANATION REQUIREMENT FOR BLOCKS 26c AND 27c represent decreases. All other notations are as defined for this data element.
No rounding adjustment is needed for the beginning physical inventory.
The rounding adjustment should be coded RAXX where XX stands for the code of the entry to which the rounding adjustment pertains (e.g., RALN means a rounding adjustment to the consolidated entry on the nuclear loss).
34 (30)
ReceiptsMiscellaneous. Enter quantities of material received in two-party transactions where only receiver=s data or receipts of quantities of material falling below the reporting level are reported and now cumulatively total 1 gram or more for SNM or 1 kilogram or more for source material.
Examples include receipts of material (not reported elsewhere) from facilities that have not been assigned an RIS and receipts from licensees who are not required to document or report transactions.
Licensee entry required 37 Procurement by Others. Enter quantities of material purchased by the facility for its own account from in situ material that it had been holding or material that the facility is processing for another licensee.
54 (51)
ShipmentsMiscellaneous. Enter quantities of material shipped in two-party transactions where only shippers data are reported or shipments of quantities of material falling below the reporting level are reported and now cumulatively total 1 gram or more of SNM or 1 kilogram or more for source material.
Examples are shipments of material (not reported elsewhere) from facilities that have not been assigned a reporting identification symbol and shipments from licensees that are not required to document or report transactions.
Licensee entry required
NUREG/BR-0006, Rev. 8 B-7 TRANS. MBR CODE LINE EXPLANATION REQUIREMENT FOR BLOCKS 26c AND 27c 65 Rounding Adjustment Entry required by licensee. Note: A negative value adds to the site inventory.
APPENDIX C EXAMPLE DOCUMENTATION OF SHIPPER AND RECEIVER DATA (BLOCKS 26 AND 27)
C-1 NUREG/BR-0006, Rev. 8 EXAMPLE DOCUMENTATION OF SHIPPER AND RECEIVER DATA (BLOCKS 26 AND 27)
EXAMPLE 1aINITIAL REPORT On March 31, 2008, shipper YYY transferred to receiver XXX four fabricated fuel elements containing the following:
Line Element Isotope 1
FAB FUEL ELE-1 377699 g 18111 g 2
FAB FUEL ELE-2 42114 g 1344 g 3
FAB FUEL ELE-3 377855 g 18122 g 4
FAB FUEL ELE-4 41992 g 1340 g EXAMPLE 1bRECEIVERS REPORT On April 1, 2008, receiver XXX acknowledged receipt of the shipment and accepted the shippers weights without further measurement.
EXAMPLE 1c CORRECTION 1 On April 16, 2008, the shipper corrected the element weights for lines 1 and 4 to reflect the adjusted element and isotope weights as well as obligated enriched uranium.
EXAMPLE 1d RECEIVERS CORRECTION 1 On April 23, 2008, the receiver acknowledged receipt of the correction and reported the corrections to NMMSS.
EXAMPLE 2m (ACTION CODE M)
On March 31, 2008, facility XXX reported on-site inventory adjustments of fission, decay and production that changed their inventory of enriched uranium and plutonium.
Example 2m-a Correction (ACTION CODE M)
On March 31, 2007, facility XXX reported a correction to their on-site production of plutonium.
This change also changes the quantity of obligated plutonium at the facility.
EXAMPLE 3aEXPORT OF A FUEL ASSEMBLY On March 31, 2008, facility YYY reported the export of one fuel assembly to a foreign facility.
EXAMPLE 4aINITIAL REPORT OF AN IMPORT
NUREG/BR-0006, Rev. 8 C-2 On March 31, 2008, facility XXX submitted a report documenting the shipment of three fuel assemblies from a foreign facility YYY.
EXAMPLE 4bRECEIVERS REPORT OF AN IMPORT On March 31, 2008, facility XXX submitted a report documenting the receipt of three fuel assemblies from a foreign facility YYY.
EXAMPLE 5a -INITIAL REPORT OF SHIPMENT TO BURIAL SITE On March 31, 2008, facility XXX submitted a report documenting the shipment of uranium waste to a burial site.
EXAMPLE 5b -RECEIVERS REPORT OF A SHIPMENT TO BURIAL SITE On April 5, 2008, facility VVV submitted a report documenting the receipt of uranium waste to the burial site.
List of Examples:
Example 1a: DOE/NRC Form 741Initial report Example 1b: DOE/NRC Form 741Receivers report Example 1c: DOE/NRC Form 741Correction 1 (shipper adjusting lines 1 and 4 of the initial transaction)
Example 1d: DOE/NRC Form 741Correction 1 (receiver adjusting lines 1 and 4 of the initial transaction)
Example 2m: DOE/NRC Form 741 Initial report (action code M)
Example 2m-a:DOE/NRC Form 741Correction 1 (action code M)
Example 3a: DOE/NRC Form 741Initial report (export from the USA)
Example 4a: DOE/NRC Form 741Initial report (shipment to the USA)
Example 4b: DOE/NRC Form 741Receivers report (shipment to the USA)
Example 5a: DOE/NRC Form 741Initial report (shipment to a burial site)
Example 5b: DOE/NRC Form 741Receivers report (shipment to a burial site)
C-3 NUREG/BR-0006, Rev. 8
NUREG/BR-0006, Rev. 8 C-4
C-5 NUREG/BR-0006, Rev. 8
NUREG/BR-0006, Rev. 8 C-6
C-7 NUREG/BR-0006, Rev. 8
NUREG/BR-0006, Rev. 8 C-8
C-9 NUREG/BR-0006, Rev. 8
NUREG/BR-0006, Rev. 8 C-10
C-11 NUREG/BR-0006, Rev. 8
NUREG/BR-0006, Rev. 8 C-12
C-13 NUREG/BR-0006, Rev. 8
APPENDIX D GLOSSARY
D-1 NUREG/BR-0006, Rev. 8 GLOSSARY Accountability The determination of, and current record maintenance of, special nuclear material and source material quantities associated with transfers, measured discards, inventories, and inventory differences that might result from theft, diversion, or other unidentified loss mechanisms.
Agreement State A State that has signed an agreement with the U.S. Nuclear Regulatory Commission under which the State regulates the use of byproduct, source, and small quantities of special nuclear material in that State.
Book inventory The algebraic sum of the most recent physical inventory of the material balance area and of all inventory changes that have occurred since the physical inventory was taken.
Concise note Additional nuclear material transaction, material balance, or inventory data supplied, in free text format, by facilities engaged in the import and/or export of nuclear materials, by facilities selected under the provisions of the agreement between the United States and the International Atomic Energy Agency (IAEA) for the application of safeguards in the U.S./IAEA Safeguards Agreement, or by a facility that would like to transmit any additional explanatory nuclear material information.
EURATOM As of January 2008, an organization consisting of the member countries Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Poland, Portugal, Romania, the Slovak Republic, Slovenia, Spain, Sweden, and the United Kingdom.
Foreign obligated nuclear material Source material or special nuclear material that is subject to the terms and conditions of an agreement that the U.S. Government has entered into with another government or group of governments.
Highly enriched uranium (HEU) Uranium enriched to 20 percent or greater in the isotope uranium-235.
Holding account Typically identified by four-character reporting identification symbols (RISs) ending in the letter H assigned by the U.S. Nuclear Regulatory Commission. Some enrichment facilities have holding accounts identified by three-character RISs beginning with the letter V.
Regardless of the RIS, these accounts usually acquired inventory from the shipment of licensed material from the primary RIS in use at the licensee. Typically, a small number of licensees have used these accounts for nuclear materials not expected to be immediately processed, reprocessed, or disposed. However, the licensed nuclear materials in holding accounts are still in the licensees possession and must be included in inventories reported to the Nuclear Materials Management and Safeguards System.
Inventory difference (ID) The arithmetic difference between a book inventory and the corresponding physical inventory that closes the material balance period. It is calculated by subtracting the ending inventory (EI) and removals from inventory (R) from the beginning
NUREG/BR-0006, Rev. 8 D-2 inventory (BI) and additions to inventory (A) during the period between physical inventories.
Mathematically, ID can be expressed in the following way:
ID = (BI + A - R) - EI where (BI + A - R) is the book inventory.
Inventory reconciliation The adjustment of the book record quantity of both elements and fissile isotopes to reflect the results of a physical inventory. In a broad sense, inventory reconciliation involves the activities of calculating (1) the inventory difference (ID) for the material balance period in question, (2) the uncertainty value associated with the ID, (3) the active inventory for the period, and (4) any bias adjustment and/or prior period adjustment associated with the ID value.
Low-enriched uranium (LEU) Uranium enriched below 20 percent in the isotope uranium-235.
Material balance period The time span to which a material or physical inventory pertains.
Nuclear Materials Management and Safeguards System (NMMSS) The national database and information system for select nuclear materials controlled by the U.S. Government. This system was created to support national safeguards and management objectives in domestic and international programs. The system stores data on nuclear material transactions and inventories and produces a wide range of printed reports for use by the U.S. Department of Energy and the U.S. Nuclear Regulatory Commission and their licensees. The system is used to satisfy the nuclear materials information requirements of agreements between the United States and foreign entities. In addition, the system provides the reporting interface between facilities selected under the provisions of the U.S./International Atomic Energy Agency Safeguards Agreement.
Physical inventory A physical determination of the quantity of nuclear material on hand at a given time. The methods of physical inventory and the associated measurements vary, depending on the material to be inventoried and the process involved. A book inventory between physical inventory takings can be determined based on the physical inventory quantity from the prior period together with all subsequent inventory changes associated with the determination of that book inventory. The primary purpose of a physical inventory is to confirm the absence of (or to detect) a loss, theft, or diversion of special nuclear material.
Report period A Period inclusive of defined dates (e.g., October 1, 2005, through September 30, 2006). Reports for a reporting period, such as inventory, material balance, and related transactions reports, must assure that no dates are undocumented between the previous and current submittals.
Reporting identification symbol (RIS) A unique combination of three or four letters that is assigned to each reporting organization by the U.S. Department of Energy or the U.S. Nuclear Regulatory Commission for the purpose of identification in the Nuclear Materials Management and Safeguards System database.
D-3 NUREG/BR-0006, Rev. 8 Shipper-receiver difference (SRD) The difference between what a shipper claims a shipment of special nuclear material contained and what the receiver claims it received, in cases where both the shippers and receivers values are based on measurement.
Source material Uranium or thorium, or any combination thereof, in any physical or chemical form; or ores that contain by weight 0.05 percent or more of uranium, thorium, or any combination thereof. Source material does not include special nuclear material.
Special nuclear material (SNM) Plutonium, uranium-233, and uranium enriched in the isotope 233 or 235.
U.S. Government owned Nuclear material that, while used by a licensee as part of its activities, is actually an asset owned by a Federal Government agency such as the U.S.
Department of Energy. These materials may be bulk materials, discrete radiation sources, or finished products. Such materials may represent a lease or loan arrangement with a Government agency. Government-owned materials are typically represented by the owner code G on shipping information (i.e., DOE/NRC Form 741) and inventory documentation (i.e.,
DOE/NRC Forms 742 and 742C). One way a licensee can make a determination that nuclear material in its possession is Government owned is to review the licensees DOE/NRC Form 741 documentation listing the original receipt of the material. If such material is Government owned, the owner code G will appear on the licensees portion of the form.
APPENDIX E DOE/NRC FORM 740M, CONCISE NOTE, (BLANK) AND DOE/NRC FORM 741, NUCLEAR MATERIAL TRANSACTION REPORT (BLANK)
E-1 NUREG/BR-0006, Rev. 8
E-2 NUREG/BR-0006, Rev. 8
APPENDIX F SUPPLEMENTAL INSTRUCTIONS FOR COMPLETING BLOCKS 17, 18, 19, 20, AND 21 ON DOE/NRC FORM 741
F-1 NUREG/BR-0006, Rev. 8 SUPPLEMENTAL INSTRUCTIONS FOR COMPLETING BLOCKS 17, 18, 19, 20, AND 21 ON DOE/NRC FORM 741
- 1. Introduction Special procedures must be used to implement some of the reporting requirements of the U.S. Bilateral Agreements for Peaceful Nuclear Cooperation. These Agreements for Cooperation are one means to satisfy Section 123 of the Atomic Energy Act of 1954 and allow the U.S. nuclear industry to trade with foreign countries/entities. The agreements require that the United States track and report foreign obligated nuclear materials and nuclear material produced from obligated material from these countries/entities. A foreign obligation is a commitment by one government to another to treat nuclear materials, nonnuclear materials, and equipment and components in a manner consistent with the agreement signed by the two governments.
In addition to these Agreements for Cooperation, the United States is also required (pursuant to the U.S./Russian agreement concerning the disposition of highly enriched uranium extracted from nuclear weapons) to track and report to Russia the imports, exports, and use of former Soviet Union downblended highly enriched uranium. Although not a U.S. Bilateral Agreement for Peaceful Nuclear Cooperation, this agreement contains similar reporting requirements and will be tracked as such. Facilities that are importers and/or exporters of nuclear material should also comply with the agreement.
The exchange of obligations can occur only between like materials (i.e., material type (MT) 10, 50, 70, 81, E-1, E-2, E-3, or E-4) within the following constraints:
No exchange of material from one MT to another is allowed unless the U.S. Government provides written prior approval. For example, downblending of E-3 enriched uranium that results in a lower category (i.e., E-3 of obligated material to become E-1 material) requires written prior approval of the U.S. Government.
The obligated material must be exchanged for similar material unless the U.S. Government provides written prior approval. For example, nonirradiated material may not be swapped for irradiated nuclear material unless the U.S. Government provides written prior approval.
Obligation exchanges involving a licensee of the U.S. Nuclear Regulatory Commission (NRC) and an entity of the U.S. Department of Energy require the NRCs written prior approval.
Obligation exchanges between two parties must be for the same material quantities.
Additionally, the obligations exchanged must match (i.e., the obligation shipped or removed by one participant is received or added by the second party to the transaction).
NUREG/BR-0006, Rev. 8 F-2
- 2. Imports For U.S. facilities importing nuclear material with foreign obligations, the relevant obligation information will be supplied by the appropriate Government agency. The notification will provide the information necessary to complete blocks 17-21, if applicable:
For imports, the foreign obligation information can be (1) the country/entity from which the nuclear material was shipped and/or (2) the country/entity attaching third-party obligations. In most cases, for imports from a country that has made the entire shipment subject to the agreement, the total import quantity will be obligated. If only a portion of the shipment is subject to an agreement (third-party obligation), the documentation will clearly specify that amount.
For the completion of blocks 17-21, the Government notification will supply (1) the country/entity of obligation, (2) the MT, and (3) the amount obligated. (See Table 1 below for country/entity codes. See Table 2 below for reportable obligated MTs and quantities.)
Table 1 Obligation Code Country/Entity 31 Australia 32 Canada 33 EURATOM 34 Japan 35 Peoples Republic of China 37 Switzerland 38 Argentina 39 Brazil 40 Chile 81 Australia/Japan 82 Canada/Japan 83 EURATOM/Japan 84 Australia/EURATOM/Japan 85 Canada/EURATOM/Japan 86 China/Japan 87 Australia/Canada 88 Australia/EURATOM/Canada 91 Australia/EURATOM 92 Canada/EURATOM
F-3 NUREG/BR-0006, Rev. 8 WR Former Soviet Union Weapons material Note: For any other obligation codes, contact the Nuclear Materials Management and Safeguards System (NMMSS) for further instructions.
Table 2 Reportable MTs and Source and Special Nuclear Material Type Domestic Code Normal uranium MT 81 Depleted uranium MT 10 Thorium MT 88 Plutonium MT 50 Enriched uranium MT 20 Uranium-233 MT 70 Licensees should complete the obligation information as follows:
Block 17: LINE NUMBERThe shipper will enter a sequential number beginning with the number 1 for each obligated country or material. If there is more than one separate obligation or more than one obligated MT, enter the appropriate numbers in the subsequent lines.
Block 18: COUNTRY OF OBLIGATIONFor each line, enter the code in Table 1 that represents the country/entity of obligation.
Block 19: MATERIAL TYPEFor each line, enter the domestic code in Table 2 that represents the material obligated.
Block 20: OBLIGATED ELEMENT WEIGHTFor each line, enter the weight obligated in the reportable quantity specified in Table 2. Positive or negative values should be entered to appropriately account for material addition or removal, respectively.
Block 21: OBLIGATED ISOTOPE WEIGHT (FOR ENRICHED URANIUM ONLY)For each line of enriched uranium, enter the obligated isotope weight in grams. (Obligated uranium-235 is restricted to uranium enriched to 5 percent or less, unless higher enrichment is authorized or approved by the U.S. Government.) Positive or negative values should be entered to appropriately account for material addition or removal, respectively.
NUREG/BR-0006, Rev. 8 F-4
- 3. Domestic Transfers, Internal Transactions, and Exports For U.S. facilities shipping or exporting material with foreign obligations, or for the reporting of onsite gains and losses, the obligations on the material must be stated as such in blocks 17-21:
For domestic transfers, fill out blocks 17-21 as for imports (Section 2 above). However, the obligation information will not be supplied by a government notification. The U.S. shipper will assign the appropriate obligations on the material, if any, and complete the line number, country/entity of obligation, MT, and obligated weight, if applicable. The U.S. receiver will complete the matching obligation information as assigned by the shipper.
For internal transactions (e.g., burnup, decay, production, measured discards, accidental losses or gains, category changes, fission and transmutation, inventory differences),
enter the line number, country/entity of obligation, MT, and obligated weights, if applicable, for the material.
The domestic facility must obtain the information necessary to complete DOE/NRC Form 741 for the foreign facility for all imports of special nuclear material and source material. In the case of exports, the shipper initiates a DOE/NRC Form 741 report, and the NMMSS will generate a DOE/NRC Form 741 report using shipper information. However, if a significant shipper-receiver difference is identified between the U.S. shipper and foreign receiver (as defined in Title 10, Section 74.31, Nuclear Material Control and Accounting for Special Nuclear Material of Low Strategic Significance, of the Code of Federal Regulations (10 CFR 74.31), 10 CFR 74.43, Internal Controls, Inventory, and Records, or 10 CFR 74.59, Nuclear Material Control and Accounting for Special Nuclear Material of Low Strategic Significance, for special nuclear material, or if there is an indication of loss, theft, or diversion of quantities of source material delineated in 10 CFR 40.64 (c)(1)), the shipper is required to document the foreign partys values in a DOE/NRC Form 741 report to the NMMSS. Submittal for a foreign facility does not indicate a responsibility for the other facility or its shipment/receipt of materials.
APPENDIX G SUPPLEMENTAL INSTRUCTIONS FOR POSSESSORS OF NUCLEAR MATERIAL OUTSIDE FACILITIES REPORTING PURSUANT TO THE MODIFIED SMALL QUANTITIES PROTOCOL
G-1 NUREG/BR-0006, Rev. 8 SUPPLEMENTAL INSTRUCTIONS FOR POSSESSORS OF NUCLEAR MATERIAL OUTSIDE FACILITIES REPORTING PURSUANT TO THE MODIFIED SMALL QUANTITIES PROTOCOL
- 1. Introduction INFCIRC/366, U.S.-IAEA Caribbean Territories Safeguards Agreement, is an agreement between the U.S. Government and the International Atomic Energy Agency (IAEA) for the application of safeguards in connection with the Treaty for the Prohibition of Nuclear Weapons in Latin America (Tlatelolco Treaty). Under Article 60 of INFCIRC/366, the United States is obligated to submit an initial inventory report on all nuclear material in its Caribbean territories to IAEA. Nuclear material, by IAEA definition, includes all uranium, plutonium, and thorium holdings in the relevant territories in any chemical and/or physical form. U.S. Caribbean territories include Puerto Rico and the U.S. Virgin Islands, as defined in Title 10 of the Code of Federal Regulations (10 CFR) 75.4, Definitions. The United States fulfills this reporting commitment via information collected in concert with the regulations contained in 10 CFR Part 75, Safeguards on Nuclear MaterialImplementation of US/IAEA Agreement.
This section provides instruction for licensees reporting inventory and information under 10 CFR 75.12, Communication of Information to IAEA, 10 CFR 75.32, Initial Inventory Report, 10 CFR 75.34, Inventory Change Reports, and 10 CFR 75.35, Material Status Reports, under INFCIRC/366.
- 2. General Instructions The instructions in this appendix apply only to possessors of nuclear material outside facilities (possessors), as defined in 10 CFR 75.4. Nuclear material outside facilities means nuclear material which is not in a facility, and is customarily used in amounts of one effective kilogram or less. Possessors are required to complete U.S. Department of Energy (DOE)/U.S.
Nuclear Regulatory Commission (NRC) Form 741, Nuclear Material Transaction Report, when they ship, receive, or adjust their physical inventory of source or special nuclear material (SNM).
Possessors may need to provide additional information for their inventory adjustments. The additional information is reported using DOE/NRC Form 740M, Concise Note. Unless otherwise specified by license conditions, such reports shall be dispatched no later than the close of business the next working day for shipments and within 10 days after receipt of material, per the reporting requirements in 10 CFR 40.64, Reports, 10 CFR 74.15, Nuclear Material Transaction Reports, and 10 CFR 75.34, Inventory Change Reports. The reports must be filed as specified in the facility attachment (FA) for possessors, which the NRC will provide to applicable licensees required to report pursuant 10 CFR 75.
Possessors will be required to complete both the shippers data and receivers data blocks of DOE/NRC Form 741 for imports received from outside the U.S. Caribbean territories.
Possessors are also required to report to the Nuclear Material Management and Safeguards System (NMMSS) all receipts, transfers, and inventory adjustments of U.S.
NUREG/BR-0006, Rev. 8 G-2 Government-owned, -loaned, or -leased material in their possession. Reports to the NMMSS for all U.S. Government-owned, -loaned, or -leased material must follow the U.S. Governments reporting requirements as specified in DOE Orders Series 470 (DOE Order 470.4B, Safeguards and Security Program, and DOE Order 474.2, Nuclear Material Control and Accountability).
Under 10 CFR 75.12, possessors shall provide the possessors name and mailing address, physical location of the nuclear material, use of the nuclear material, and nuclear material accounting procedures, including organizational responsibilities for accountancy and control, on DOE/NRC Form 740M, Concise Note. Form 740M will also be submitted to define transactions of greater than 0.0 kilograms but less than 0.5 kilograms of source material and greater than 0.0 grams but less than 0.5 grams of SNM, which are rounded to a zero value when reported by the NMMSS.
2.1. Instructions for Completing DOE/NRC Form 741 Reports Licensees should complete DOE/NRC Form 741 in accordance with the following instructions:
- 1.
SHIPPERS RISEnter the shippers reporting identification symbol (RIS).
- 2.
RECEIVERS RISEnter the receivers RIS.
- 3.
TRANSACTION NUMBEREnter a number for the same shipper-receiver combination.
Numbers in the series must be consecutive (i.e., no skipped numbers).
- 4.
CORRECTION NUMBERThis block is used to identify a transaction that is an adjustment to a previously submitted DOE/NRC Form 741. Leave this block blank for an original submission of a DOE/NRC Form 741. Use consecutive numbers, starting with 1, for adjustments. For corrections requiring changes only to NMMSS data (and not to the other partys data), use letters (A, B, etc.) instead of numbers. See Chapter 4 of this NUREG.
- 5.
PROCESS CODEEnter process code A, C, D, or Z.
A refers to the initial entry of data.
C refers to the replacement of data. With the concurrence of the other party to the transaction, up to an entire data set may be replaced at any time before the close of the NMMSS processing period in which the initial submittal was made.
D refers to the deletion of data. An entire data set may be deleted at any time before the close of the NMMSS processing period in which the initial submittal was made, with the concurrence of the other party to the transaction.
Z refers to the receivers acceptance of other partys correction. This processing code can be used only with action code D. Receivers reporting in accordance with 10 CFR Part 75 may not use the Z code.
G-3 NUREG/BR-0006, Rev. 8
- 6.
ACTION CODEThis block is used to identify the type of transaction being reported on DOE/NRC Form 741, as specified in 6a and 6b, below.
6a.
SHIPPEREnter one of the following action codes:
A The shipper is reporting a transaction that has taken place between the stated parties.
C The shipper is adjusting the initial DOE/NRC Form 741 for the shipment or a previous adjustment to the same initial report, acknowledging an adjustment originated by the receiver, or accepting and agreeing with the receivers adjustment to DOE/NRC Form 741. See Chapter 4 of this NUREG.
M The shipper is reporting a one-party transaction or an adjustment to a one-party transaction (e.g., an onsite gain or loss of material as the result of burnup, production, measured discards, category changes). DOE/NRC Form 742, Material Balance Report, shows such inventory changes. See Chapter 3 of this NUREG.
R The shipper is identifying a one-party transaction to delete an obligated amount of material from the facilitys inventory. This code is applicable only to former Soviet Union weapons (WR) material after the fresh low-enriched uranium (LEU) is irradiated in a reactor core. Use of this code implies a removal of WR from LEU; therefore, the value should be entered as a positive number.
X The shipper is reporting a transfer of obligation that involves no physical movement of material. No obligation transfers of WR material are permitted. No shipper (block 26) or receiver (block 27) detail data need to be entered.
6b.
RECEIVEREnter one of the following action codes:
B The receiver is reporting that a shipment has been received and that the weights reported by the shipper on DOE/NRC Form 741 were accepted as final receipt values.
E The receiver is reporting that a shipment was received, that independent measurements were made, and that the values resulting from the independent measurements are being reported.
D The receiver is adjusting the initial DOE/NRC Form 741 that documented the receipt of a shipment or a previous adjustment to the same initial report, or acknowledging an adjustment originated by the shipper, or accepting and agreeing with the shippers adjustment to DOE/NRC Form 741. See Chapter 4 of this NUREG.
NUREG/BR-0006, Rev. 8 G-4 M
The receiver is reporting a one-party transaction or an adjustment to a one-party transaction (e.g., an onsite gain or loss of material as the result of burnup, production, measured discards). DOE/NRC Form 742 shows such inventory changes. See Chapter 3 of this NUREG.
N The receiver is reporting physical receipt of a shipment but will delay the quantity determinations for the shipment of material for more than 10 days but no more than 60 days for source and LEU, or no more than 45 days for highly enriched uranium. At the end of this time, the receiver will prepare a DOE/NRC Form 741 with a B or E action code to report the receivers quantity determinations. Use of this code (N) requires no entry of detailed data (block 27) by the receiver.
Y The receiver is reporting an acceptance of transfer of obligation that involves no physical movement of material. No shipper (block 26) or receiver (block 27) detailed data need to be entered.
- 7.
DOCUMENTATIONLeave blank.
- 8. SHIPPERLeave blank.
- 9.
RECEIVERLeave blank.
- 10. NUMBER OF DATA LINESAfter completing block 26 (SHIPPERS DATA), or block 27 (RECEIVERS DATA), enter the total number of detail lines in block 26 or 27. The shipper and receiver must report the same number of entries, and the material types must agree line for line.
- 11. NATURE OF TRANSACTIONLeave blank.
- 12.
SHIPPED FOR ACCOUNT OFLeave blank.
- 13.
SHIPPED TO ACCOUNT OFLeave blank.
- 14.
TRANSFER AUTHORITYLeave blank.
- 15.
EXPORT OR IMPORT TRANSFERSFor all exports to or imports from countries outside of the United States and its Caribbean territories, enter the NRC export or import license number under which SNM or source material is being transferred. If transfers are authorized by an NRC general license, enter GEN-LIC. In some cases, the transfer may be exempt from licensing, such as exports of IAEA safeguards samples; in that case, enter LIC-EXEMPT. If several batches authorized by separate NRC import or export licenses are combined into one shipment, a separate DOE/NRC Form 741 must be completed for the portion associated with each NRC import or export license.
- 16.
MATERIAL TYPE AND DESCRIPTIONLeave blank.
G-5 NUREG/BR-0006, Rev. 8
- 17.
(FOREIGN OBLIGATION) LINE NUMBEREnter a sequential line number beginning with the number 1.
- 18.
COUNTRY OF OBLIGATIONEnter the two-character country or entity designation from Table 1 in Appendix F for the line numbers entered in block 17. See Appendix F to this NUREG for further instructions.
- 19.
MATERIAL TYPEEnter the material type to which the obligation is attached. Refer to Table 2 in Appendix F. The only material types (see field 26g) to be reported are 10, 20, 50, 70, 81, and 88.
- 20.
OBLIGATED ELEMENT WEIGHTEnter the weight of the obligated amount of the element for material types 10, 50, 81, or 88. See Appendix F to this NUREG for further instructions. Positive or negative values should be entered to appropriately account for material addition or removal, respectively. Reports with an action code of A, B, E, R, X, or Y must be reported with a positive weight. All others can be reported with a positive or negative weight. The sum of obligated element weight for a material type cannot exceed the sum of the element weight value listed in the detail lines (see fields 26n and 27n).
- 21.
OBLIGATED ISOTOPE WEIGHTFOR ENRICHED URANIUM ONLYEnter the weight of the obligated amount of the isotope uranium-233 (U233) or uranium-235 (U235). For in-place inventory-adjustment activity, positive or negative values should be entered to appropriately account for material addition or removal, respectively. Reports with an action code of A, B, E, R, X, or Y must be reported with a positive weight. All others can be reported with a positive or negative weight. The sum of obligated isotope weights for a material type cannot exceed the sum of the isotope weight value listed in the detail lines (see field 26q or 27q).1
- 22.
ACTION DATEFollow the instructions below for blocks 22a through 22e.
22a.
SHIPMENT (entry required by shipper)Enter the date the nuclear material is shipped.
22b.
SHIPPERS CORRECTION (entry required by shipper)If the DOE/NRC Form 741 is an acknowledgment of or a correction to a previously submitted Form 741, enter the date the correction is recorded or the acknowledgment is made, as appropriate. However, the date of an acknowledgment must not precede the action date listed on the receivers correction. Additionally, be aware that if a date preceding the current unreconciled period is used, the effect of the correction will be reflected in the current period, not the prior period(s) covered by postdated documents.
22c.
RECEIPT (entry required by receiver)Enter the date the nuclear material is received.
22d.
RECEIVERS MEASUREMENT (entry required by receiver)This entry is required only if the receivers action code is E. Enter the date the nuclear material is measured by the receiver.
1 Note that for enriched uranium, the foreign obligation is assigned to the U233 and U235 isotopes. Report the quantity of uranium element that contains the obligated U233 and U235 in field 20.
NUREG/BR-0006, Rev. 8 G-6 22e.
RECEIVERS CORRECTION (entry required by receiver)If the document is an acknowledgment or a correction to a previously issued transaction report, enter the date the correction is recorded or the acknowledgment is made, as appropriate. However, the date of an acknowledgment must not precede the action date listed on the receivers correction. Additionally, be aware that if a date preceding the current unreconciled period is used, the effect of the correction will be reflected in the current period, not the prior period(s) covered by postdated documents.
Note that in the case of all imports (and for some exports; see Section 1.3 of this NUREG), licensees must complete a separate DOE/NRC Form 741 to document the foreign party action, including action dates in blocks 22a and 22c, as applicable.
23a.
MISCELLANEOUSLeave blank.
23b.
CONCISE NOTE ATTACHEDLeave blank.
23c.
UK REPORTABLEFacilities reporting material transfers involving facilities in the United Kingdom must indicate in this block whether the shipment is for peaceful nuclear activities (reportable to IAEA) or for nonpeaceful nuclear activities (not reportable to IAEA). Insert R to indicate that the transfer should be reported to IAEA or N to indicate that the transfer should not be reported to IAEA.
Note that typically all licensee shipments to and from the United Kingdom are reportable.
- 24.
TOTAL GROSS WEIGHTEnter the total gross weight of the shipment rounded to the nearest kilogram. An approximate or estimated gross weight rounded to the nearest kilogram is acceptable. Make no entry for M action code transactions, receipts, obligation transfers, and correction documents.
- 25.
TOTAL VOLUME (WASTE TRANSFERS ONLY)For transfers of nuclear material to nuclear waste sites (i.e., receiver RIS begins with the letter V), enter the volume of the material to be buried, stated in cubic feet rounded to the nearest cubic foot. An entry in block 25 is not required for transfers to nuclear laundry services.
- 26. SHIPPERS DATAEnter the shippers data in block 26. Possessors of nuclear material outside facilities must provide an entry in this block even when documenting receipt of material in the RECEIVERS DATA (field 27). Information in this block is needed to facilitate a match between shipper and receiver reporting to the NMMSS. Instructions for completing this block are provided in 26a through 26s.
Shipper and receiver measurement data are entered on DOE/NRC Form 741 for each batch of material. A batch is a portion of nuclear material that is handled as a unit for
G-7 NUREG/BR-0006, Rev. 8 accounting purposes at a key measurement point (KMP) and whose composition and quantity are defined by a single set of specifications or measurements. The batch may be in bulk form or contained in a number of separate items. Otherwise, material being transferred may be listed on one line of DOE/NRC Form 741 if the material is all of the same material type, composition, ownership, and weight percent of isotope (except as noted in the next paragraph). Material differing in any of these data elements must be listed on separate lines.
Two or more lines may be necessary to describe a single batch. If a batch consists of several material types, several consecutive lines should be used to describe the batch.
The batch name should be repeated on all lines used to describe a single batch. In block 26e, the number of items is also repeated on all lines with the same batch name.
26a.
BACK REFERENCE NUMBEREnter the appropriate back reference number adjustments to previously completed DOE/NRC Form 741 documents.
Licensees must enter the back reference numbers for action codes C and D and for action code M when reporting adjustments. Licensees must report both the back reference change digit and the back reference line number.
The back reference change digit represents the change digit of the document being corrected for a nullifying entry and the change digit of the document now being completed for a correcting entry. For example, if the DOE/NRC Form 741 being corrected is the original, or if the line being entered represents an addition only, enter zero.
The back reference line number represents the line number of the line being corrected for a nullifying entry and the line number of the corresponding nullifying line for a correction entry. If the line being entered represents an addition only or represents a net change, enter zeros.
26b.
LINE NUMBERIn providing detailed measurement data, enter a line number beginning with 1 for the first line of detailed shippers data and increase the line number by one for each additional line of detailed shippers data entered on the form. When two or more lines of measurement data refer to a single batch, repeat the unique batch name for each line of the batch data.
26c.
TYPE OF INVENTORY CHANGEAll changes to inventory that meet the reporting criteria must be reported on DOE/NRC Form 741.
Appendix B to this NUREG explains the inventory change type (ICT) codes and indicates whether they are to be entered in block 26c. Enrichment facilities may use the two-digit numerical value for indicating a change type or proceed as directed by the NRC. When shipping to a V RIS, the shipper must use ICT code 74. A measured discard can be documented as an onsite transfer, a discard to a pond/lagoon, or a transfer to a holding area. Discharges to a lagoon and movement to holding areas are documented with a suffix attached to the RIS:
NUREG/BR-0006, Rev. 8 G-8 Use L when material is discarded into a pond or lagoon.
Use H when material is transferred to a holding area (refer to the term holding account in the glossary in Appendix D) at the facility pending possible shipment offsite for disposal.
Note that use of a holding area or lagoon account requires establishment of the account and prior approval by the NRC.
The shipper should enter its RIS in block 1 (SHIPPERS RIS) and the same RIS in block 2 (RECEIVERS RIS), but append an L or H to the receivers RIS as appropriate.
For example, if a facility with RIS XYZ discards material to a lagoon, the transaction on DOE/NRC Form 741 would be from XYZ to XYZL.
26d.
BATCH NAMEEnter a name or number, or a combination of both, that identifies the batch of material being shipped (i.e., serial number of device). The shipper or receiver shall enter a name that identifies a unique portion of nuclear material handled as a unit for accounting purposes.
In the case of an import, the receiver must document the shippers activity and use the same batch name as the shipper used.
When two or more lines of measurement data refer to a single batch, repeat the unique batch name for each line of the batch data.
26e.
NUMBER OF ITEMSEnter the number of similar items of which the line entry consists (e.g., cylinders, packs, drums, bird cages, bottles, tank vessels). In the case of a transfer of bulk material, enter the number 1. Leave blank if an M action code is used.
26f.
PROJECT NUMBERLeave blank.
26g.
MATERIAL TYPEEnter the appropriate SNM or source material type code from the list below.
Domestic Transfers within Caribbean Territories Imports into/Exports out of the Caribbean Territories Description 10 D
Depleted uranium 20 EG Enriched uranium 50 P
Plutonium 70 EK U233
G-9 NUREG/BR-0006, Rev. 8 81 N
Normal uranium 832 Pu Pu238 88 T
Thorium 89 No code Uranium in cascade 26h.
COMPOSITION/FACILITY CODE Enter the appropriate code from the list provided in the facility attachment.
Note: In accordance with 10 CFR 75.11, Location Information, any change in operations or processes that would result in any changes in, additions to, or deletions from the list should be communicated to the NRC.
26i.
OWNER CODEThis code identifies the ownership of the material at the time it was in the shippers possession. Enter the appropriate code from the following:
G U.S. Government-owned J
Not U.S. Government-owned Refer to the glossary in Appendix D to this document for further description of U.S. Government-owned material.
26j.
KEY MEASUREMENT POINT (KMP)Enter the appropriate code from the list provided in the facility attachment.
26k.
MEASUREMENT IDENTIFICATION (see 26j)Enter the appropriate code from the list provided in the facility attachment.
26k1. BASIS Enter the appropriate code from the list provided in the facility attachment.
26k2. OTHER MEASUREMENT POINT (OMP)Enter the appropriate code from the list provided in the facility attachment.
26k3. MEASUREMENT METHOD Enter the appropriate code from the list provided in the facility attachment.
26l.
GROSS WEIGHTLeave blank.
26m. NET WEIGHTLeave blank.
26n.
ELEMENT WEIGHTEnter the weight of the contained SNM or source material rounded to the quantities reported below.
2 Report as plutonium-238 (Pu238) if the contained Pu238 is greater than 10 percent of total plutonium by weight; otherwise, report as plutonium.
NUREG/BR-0006, Rev. 8 G-10 Material Reporting Units Plutonium or uranium enriched in U235 or U233 Nearest whole gram Pu238 Nearest 1/10 gram Source material Nearest kilogram If the quantity to be entered is equal to or greater than 0.5 of the reporting unit, the quantity should be rounded up to the next whole reporting unit. If the quantity to be entered is less than 0.5 of the reporting unit, the quantity should be rounded down to the next whole reporting unit.
26o.
ELEMENT LIMIT OF ERRORLeave blank.
26p.
WEIGHT % ISOTOPEEnter the weight percent of the isotope U235 contained in either enriched uranium or depleted uranium. Make no entry for U235 contained in natural uranium. If plutonium, enter the weight percent of the isotope plutonium-240 (Pu240). If Pu238, enter the weight percent of the isotope Pu238. Report weight percent to at least two, but not more than four, decimal places, depending on the accuracy of the measurement method employed (for example, XX.XXXX%). For U233, enter the parts per million of uranium-232 (U232). This block does not apply to thorium. Use separate lines to report material of different enrichments.
26q.
ISOTOPE WEIGHTEnter the isotope weight. For enriched uranium or U233, enter weight to the nearest gram of U235 or U233 as appropriate. If plutonium, enter the sum of plutonium-239 (Pu239) and plutonium-241 (Pu241) to the nearest gram. If Pu238, enter the weight of the isotope Pu238 to the nearest one-tenth of a gram. If natural or depleted uranium, enter weight to the nearest gram of U235. Make no entry for source material.
If the quantity to be entered is equal to or greater than 0.5 of the reporting unit, the quantity should be rounded up to the next whole reporting unit. If the quantity to be entered is less than 0.5 of the reporting unit, the quantity should be rounded down to the next whole reporting unit.
26r.
ISOTOPE LIMIT OF ERRORLeave blank.
26s.
SIGNATURE OF AUTHORIZED OFFICIAL AND DATE SIGNEDIf submitted on paper, the report must be signed by an authorized representative of the licensee and dated.
Otherwise, no entry is required.
Each licensee must establish internal procedures to ensure that the information provided in the report is accurate and that the report has been prepared and issued only by authorized licensee personnel.
G-11 NUREG/BR-0006, Rev. 8 Proprietary information must be included when necessary to provide an adequate response. An application to withhold such information from public disclosure may be made and will be dispositioned in accordance with the provisions of 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding. If any of this information is of particular sensitivity, a request may be made that such information not be transmitted to IAEA. Such a request must refer to and conform with 10 CFR 75.12.
- 27.
RECEIVERS DATAEnter the receivers data in block 27. Possessors of nuclear material outside facilities that receive imports from outside the Caribbean territories must provide an entry in both the SHIPPERS DATA (field 26) and the RECEIVERS DATA field. Information in this field is needed to facilitate a match between the shipper and receiver reporting to the NMMSS. Shipper and receiver measurement data are entered on DOE/NRC Form 741 for each batch of material.
A batch is a portion of nuclear material that is handled as a unit for accounting purposes at a KMP and whose composition and quantity are defined by a single set of specifications or measurements. The batch may be in bulk form or contained in a number of separate items. If the shipment is an export or is being reported pursuant to 10 CFR Part 75, list fuel assemblies or loose rods or fuel pins separately with the identifying label serving as a unique batch name. Report fuel assemblies as average enrichment as long as the appropriate accounts (material types 10, 20, 81, etc.) are properly adjusted. Material being transferred may be listed on one line of DOE/NRC Form 741 if the material is all of the same material type, composition, ownership, and weight percent of isotope (except as noted in the next paragraph). List material differing in any of these data elements on separate lines.
Two or more lines may be necessary to describe a single batch (e.g., spent fuel assemblies, mixed-oxide fuel). If a batch consists of several types of nuclear material, use several consecutive lines to describe the batch. Repeat the batch name on all lines used to describe a single batch. In block 27e, also repeat the number of items on all lines with the same batch name.
The above general rules for grouping or batching material for reporting purposes also apply to licensees reporting imports or exports pursuant to 10 CFR Part 40, Domestic Licensing of Source Material, or 10 CFR Part 74, Material Control and Accounting of Special Nuclear Material. Batch names are optional for other transactions reported pursuant to 10 CFR Part 40 or 10 CFR Part 74.
27a.
BACK REFERENCE NUMBERMust match the shippers value. See 26a.
27b.
LINE NUMBERMust match the shippers value. See 26b.
27c.
TYPE OF INVENTORY CHANGEMust match the shippers value. See 26c.
27d.
BATCH NAMESee 26d.
NUREG/BR-0006, Rev. 8 G-12 27e.
NO. OF ITEMSSee 26e.
27f.
PROJECT NUMBERSee 26f.
27g.
MATERIAL TYPEMust match the shippers value. See 26g.
27h.
COMPOSITION/FACILITY CODESee 26h.
27i.
OWNER CODEDescribes the material ownership at the time it comes into the receivers possession. See 26i.
27j.
KEY MEASUREMENT POINTSee 26j.
27k.
MEASUREMENT IDENTIFICATIONSee 26k.
27l.
GROSS WEIGHTSee 26l.
27m. NET WEIGHTSee 26m.
27n.
ELEMENT WEIGHTSee 26n.
27o.
ELEMENT LIMIT OF ERRORSee 26o.
27p.
WEIGHT % ISOTOPESee 26p.
27q.
ISOTOPE WEIGHTSee 26q.
27r.
ISOTOPE LIMIT OF ERRORSee 26r.
27s.
SIGNATURE OF AUTHORIZED OFFICIAL AND DATE SIGNEDSee 26s.
2.2. Preparation of DOE/NRC Form 741 in Computer-Readable Format NMMSS Report D-24, Personal Computer Data Input for NRC Licensees, provides instructions for preparing DOE/NRC Form 741 in computer-readable format as required for submittals.
2.3 Distribution DOE/NRC Form 741 Each shipper of reportable quantities of SNM or source material must dispatch a DOE/NRC Form 741, as described below, no later than the close of business the next working day after the shipment. Burials are reported when shipped. The burial site operator must prepare a DOE/NRC Form 741 and transmit it to the NMMSS to document receipt and disposal.
Each receiver of reportable quantities of SNM or source material must dispatch a DOE/NRC Form 741, as described below, no later than 10 working days after receipt of the shipment.
G-13 NUREG/BR-0006, Rev. 8 When submitting Safeguards Information, a concise note (Form 740M) must be submitted stating that the submission is Safeguards Information and should be handled in accordance with 10 CFR 73.21, Protection of Safeguards Information: Performance Requirements.
The completed DOE/NRC Form 741 is distributed as follows:
Submit one copy in computer-readable format to the NMMSS. See Section 1.5 of this NUREG for information on the documentation and distribution of classified and unclassified reports.
Retain one copy for the file.
Provide a copy of the DOE/NRC Form 741 to another possessor of nuclear material outside facilities within the U.S. Caribbean territories.
A copy of the DOE/NRC Form 741 is not required to be provided to shippers or receivers of nuclear material outside the U.S. Caribbean territories.
2.4 Instructions for Onsite Gains and Losses When using action code M, possessors of nuclear material outside facilities should complete and distribute DOE/NRC Form 741 in accordance with the instructions contained in Chapter 3 of this NUREG.
2.5 Instructions for Correcting a DOE/NRC Form 741 When correcting a DOE/NRC Form 741, possessors of nuclear material outside facilities should follow instructions in accordance with Chapter 4 of this NUREG.
The revised DOE/NRC Form 741 is distributed as follows:
Submit one copy in computer-readable format to the NMMSS.
Retain one copy for the file.
Provide a copy of the revised DOE/NRC Form 741 to another possessor of nuclear material outside facilities within the U.S. Caribbean territories.
A copy of the revised DOE/NRC Form 741 is not required to be provided to shippers or receivers of nuclear material outside the U.S. Caribbean territories.
2.6 Instructions for Completing a DOE/NRC Form 740M A DOE/NRC Form 740M shall be used to explain circumstances under which concise notes must be submitted to IAEA.
NUREG/BR-0006, Rev. 8 G-14 Possessors of nuclear material outside facilities should follow the instructions in Chapter 5 of this NUREG to complete numbered blocks 1-10 of DOE/NRC Form 740M.
DOE/NRC Form 740M should be put into computer-readable format following the guidance in NMMSS Report D-24.
Copies of DOE/NRC Form 740M must be attached to, and distributed with, DOE/NRC Forms 741, 742, or 742C, Physical Inventory Listing, to which the DOE/NRC Form 740M applies, as appropriate.