ES-301 Administrative Topics Outline Form ES-301-1 Facility:

Fermi 2 Date of Examination:

2/26/18 Examination Level:

RO SRO Operating Test Number:

2018-1 Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations R, D Perform Torus Water Average Temperature Calculation

[K/A 2.1.45]

4.3/4.3 802-3006-401 Conduct of Operations S, D Verify Offsite Electrical Lineup

[K/A 2.1.29]

4.1/4.0 802-4101-421 Equipment Control R, M Identify isolations for Main Lube Oil Cooler Cleaning.

[K/A 2.2.13]

4.1/4.3 802-4101-418 Radiation Control S/R,D,P Notify Hospital for Contaminated Injured Worker.

[K/A 2.3.13]

3.4/3.8 802-4101-435 Emergency Plan NOTE:

All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).

  • Type Codes and Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs and RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1, randomly selected)

ES-301 Administrative Topics Outline Form ES-301-1 Facility:

Fermi 2 Date of Examination:

2/26/18 Examination Level:

RO SRO Operating Test Number:

2018-1 Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations S/R, D Perform a CRS Short Term Relief.

[K/A 2.1.3]

3.7/3.9.0 802-4101-419 Conduct of Operations R, N Torus Water Average Temperature TS Call

[K/A 2.1.45]

4.3/4.3 802-4101-460 Equipment Control R, D Evaluate Degraded Power Sources.

[K/A 2.2.36]

3.1/4.2 802-4101-102 Radiation Control R, D Approve a Discharge Permit.

[K/A 2.3.6]

2.0/3.8 802-4101-409 Emergency Plan S/R, D On-Site Protective Actions and Classification for Security Event (SAE)

[K/A 2.4.41]

2.9/4.6 802-4101-434 NOTE:

All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).

  • Type Codes and Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs and RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1, randomly selected)