Requests Response to Encl Questions Re Reactor Coolant Pump Supports
ML18116A278
Person / Time
Site: Surry 
Issue date: 07/20/1979
From: Schwencer A
Office of Nuclear Reactor Regulation
To: Proffitt W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
References
NUDOCS 7908070724
Download: ML18116A278 (4)


Text

--

Docket r~o. 50-281 JUL 2 O 1979 Mr. W. L. Proffitt Senior Vice President - Power Virginia Electric and Power Company Post Office Box 26666 Richmond, Virginia 23261

Dear Mr. Proffitt:

DI ST RIB UTION c::]ockff File 50-28-!:>

NRC PDR Loca 1 PDR

'NRR Rdg ORB1 Rdg D. Eisenhut W. Gammill B. Grimes J. CArter A. Schwen.cer KXXR~iH~UO(

P. Kreutzer I &E ( 3)

OELD

  • D. Neighbors V. Noonan ACRS (16)

J. Buchanan KRb\\X TERA

. We have reeeRt~ had a meeting, May 3, 1979~ and discussions with your staff regarding the need for inspection of the Surry 2 Reactor

'Cool ant Pump supports.

Our concern is the use of high strength marag,e steel included in these structures.

~-

So that we can make further assessment regarding inspection for these supports, it is requested that you provide the information in Enclosure l.

A timely response is requested so that we may complete our review

, while Surry 2 is shutdown for steam generator repair.

Enclosure:

Request for Additional Information cc; w/enclosure See nex_t, page A. Schwencer~ Chief Operating Reactors Branch #1 Division of Operating Reactors

\\

\\

\\

ioos o-~07;;2%

,.,! ~.

I

/

/

~) orncs~

f )I IIURNAMII:~

DATE;s.

me POllM 318 (9*76). NRCM 0240

~.IJ.. GOVERNM!lNT PRINTING OPfr'ICCC: 1978

  • 288
  • 700

i I\\_

UNITED STATES NUCLEAR REGULATORY COMMISSION,

. WASHINGTON, D. C. 20555 Docket No. 50-281 JUL 2 0 197g

  • Mr. W

~ L. Proffitt.

Senior Vice** President - Power Virginia' Electric and Power Comp~ny

  • Post. Office Box 26666 Richmond,:Virginia. 23261

Dear Mr.* Proffitt:

We* have had a meeting, May 3,. 1979, and discussions with your staff r_egardi_ng the need for inspection of the Surry 2 Reactor Coolant Pump supports.

Our concern is the use of high strength maraging steel included 'in these structures.

. So that. we can make fu"rther assessment regarding *inspection for these supports, it: is requested that you:* prov.ide the i'nfonnation i"n.

  • Enclosure* l *
  • A timely response: is requested so that we may complete* our review while Surry 2 is shutdown for. steam generator repair.

Enclosure:

Request for Additional Infonnation cc: w/enclosure See next page.-

Sincerely,

Mr. W. L. Proffitt Virginia Electric and Power Company cc: Mr. Michael w. Maupin Hunton and Williams Post Office Box 1535 Richmond~ Virginia 23213 Swem Library College of' Wi 1 liam and Mary

~ill iamsburg~- Virginia 23185

  • Donald. J *. Burke
2. -

U. S *. Nuc_l ear Regulatory-Cornmi ssion Region II Office of rnspection and Enforcement 101 Marietta Street, Suite 3100 Atlanta*, Georgia,; 30303.

JUL 2 0 1979

e

,a, I

ENCLOSURE 1 REACTOR COOLANT PUMP SUPPORTS

  • l
  • Provide details of inspection performed on the monoba11 assemblies prior to installation into the plant~. Provide significant results~

of any inspections. Include the threaded connection.

2.

Indicate the consequences of a-complete failure of the r~actor coolant pump supports. during normal and postulated accident

  • conditions.

3.. Provide. any alternative NOE methods. available which could be used to inspect* those* areas of the monoball assembly not accessible e_xcept by disassembly *.

4.

Indicate* the impact on your* steam generator repair schedule of inspecting_ fully one monoball assembly on* the reactor coolant pump* support.

  • 5.

Provide the maximum stress and stress s.tate seen by any of the monoball assembly parts under normal operation and postulated acci.dents.

6.

Provide.- the procedures that are intended to be used to inspect the reactor coolant pump supports.* *

,