{{#Wiki_filter:ATTACHMENT 13 Page 1 of 1 Unit 1 X Unit2 Reporting Period: January - December 2017 Off-Site Dose Calculation Manual <ODCM}
l n NINE MILE POINT UNIT 1 CY-NlVI-170-301 r ti OFF-SITE DOSE CALCULATION MANUAL (ODCM) REVIS10N36 Level 3 - Information Use Revision of this document requires PORC approval and changes are controllecl by CY-AA-170-3100, Offsite Dose Calculation Manual Revisions
I*
SUMMARY
OF REVISIONS Revision 36 (Effective May 2017) PAGE 1, 2, 5, 6, 8, 9, 11-13/15-18, 21, 24, 25, 36-44, 47-49, 52-81, 86-116 3,4,7,10,14,19,20,22,23,26-35 45, 46, 50, 51, 82-85
- 29
- 64,77,78 i, 19, 21, 22A, 22B, 124, 25, 26, 112 i, ii, iii, 12-16, 18, 28-40, 45-47.
52, 55, 59-89, 92, 93, 97-129 91-93, 95 3, 4, 21, 92, 95a-c 10, 16-20 5, 13, 18, 20, 25-30, 65, 79 66,69 16,69 10, 12 10, 18, 67, 69 5, D-1 5, D-1 5,D-1. D-1 iv, 3, 6, 8, 9, 11, 13, 14, 27, 29, 65, 66, 69, 69a Added Part I & Revised Part II - II 2-16, II 20-23, II 25, II 26, II 29, II 30 iv, v, \\ii, viii, I 1.0-1 and 2, I 3.1-1, 7 to 9, 11, 14, 18 to 24, 26 and 27, I B 3.1-1, 3 to 7, I 6.0-2, 4, and 5, II 2, II 3, II 4, II 6, II 9 to 11, II 13 to 22, II 42, Figure D-8, Deleted Figures D-7, D-9, D-10 DATE February 1987 December 1987 January 1988 May 1988 (Reissue) May 27, 1988 (Reissue) February 1990 June 1990 June 1992 February 1993 March 1993 June 1993 December 1993 June 1994 February 1995 December 1995 June 1996 June 1997 April 1999 December 1999 December 2001 November 2002 November 2002 CY-NM-170-301 Revision 36 May 2017
SUMMARY
OF REVISIONS (continued) Re'l'ision 36 (Effective June 2016) PAGE x, I 1.0-1, I 3.1-22, I 3.1-38 and 39, I B 3.1-1, I 6.1-0 and 3, II 11, 12, 17, 18, 24 and 25 I 3.1-7, I 3.1-8, I 3.1-9, I 3.1-10, I 3.1-11, I 3.1-12 and I B 3.1-1 II 70, II 71, and II 73 I 3.1-5, I 3.1-10, II 6, and II 24 I 1.0-1, I 3.1-1, I 3.1-2, I 3.1-3, I 3.1-4, I 3.1-5, I 3.1-7, I 3.1-8, I 3.1-9, I 3.1-10 I 3.1-11, I 3.1-12, I 3.1-23, I 3.1-27, I 3.1-28, I B 3.1-1, I B 3.1-8, I 6.0-4, II 2, II 5, II 11, II 17, and II 25 viii, I 3.1-8, I 3.1-20, I 3.1-21, I 3.1-27, II 1, II 15, II 23, II 25, II 36-II 43, II 45, II 46, II 48 - II 51, II 53, II 55 - II 65, II 67, II 70, II 71, II 78, II 83, II 92 I 3.1-16, II 68-II 71, II 73, D-1 I 6.0-3 I 3.1-9, I 3.1-12, II 5 I 3.1-10, I 3.1-25, I B 3.1-7, II 10, II 28, II 30, II 32, II 69 I 3.1-16, I B 3.1-2, II 7, II 74 Coverpage, II 16, II 17, II 67, II 84-88 I 3.1-10, I 3.1-11, I B 3.1-1, II 19 11 July 2003 February 2004 December 2005 May2006 September 2006 February 2007 October 2009 September 2010 February 2011 June 2012 December 2012 June 2016 May 2017 CY-NM-170-301 Revision 36 May 2017
ODCM - NINE MILE POINT UNIT 1 TABLE OF CONTENTS List of Tables.................................................................................................................................................... viii List of Figures................................................,.............................................................."..................................... i..~ INTRODUCTION.............................................................................................................................................. x PART I - Radiological Effluent Controls SECTION 1.0: Definitions..... :.................................................................................................... I 1.0-0 SECTION 2.0: Not Used SECTIONS 3.0/4.0: Applicability...................................................................................................... I 3.0-0 D 3/4.6.14. D3/4.6.14.a. D 3/4.6.14.b D 3/4.6.15 D 3/4.6.15.a.(1) D 3/4~6.15.a.(2) D 3/4.6.15.b.(1) D 3/4.6.15.b.(2) D 3/4.6.15.b.(3) D 3/4.6.15.d D 3/4.6.16 D 3/4.6.16.a D 3/4.6.16.b D 3/4.6.17 D 3/4.6.18 D 3/4.6.19 D 3/4.6.20 D 3/4.6.21 D 3/4.6.22 RADIOACTIVE EFFLUENT INSTRUJ\\,IENTATION................................ I 3.1-1 Liquid Effluent.................................................................................................. I 3.1-1 Gaseous Process and Effluent....... ;.................................................................. I 3.1-7 RADIOACTIVE EFFLUENTS........................................... *.......................... I 3.1-14 Liquid Concentration..................................................................................... I 3.1-14
- Liquid Dose...................................................................................................... I 3.1-15 Gaseous Dose Rate......... ;................................................................................ I 3.1-19 Gaseous Air Dose............................................................................................ I 3.1-20 Gaseous Tritium, Iodines and Particulates................................................... I 3.1-21 Uranium Fuel Cycle........................................................................................ I 3.1-24 RADIOACTIVE EFFLUENT TREAT1\\1ENT SYSTEMS...........**......**.... I 3.1-27 Liquid............................................................................................................... I 3.1-27 Gaseous............................................................................................................ I 3.1-27 Not Used MARK I CONT AINJ\\,IENT........................................................................... I 3.1-29 LIQUID WASTE HOLDUP TANKS............................................................ I 3.1-30 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM **. I 3.1-31 INTERLABORATORY COMPARISON PROGRAM............................... I 3.1-41 LAND USE CENSUS...................................................................................... I 3.1-42 lll CY-NM-170-301 Revision 36' May 2017
B 3/4.6.14 B 3/4.6.15 B 3/4.6.16 B 3/4.6.18 B 3/4.6.19 B 3/4.6.20 B 3/4.6.21 B 3/4.6.22 SECTIONS.O SECTION 6.0 ODCM - NINE MILE POINT UNIT 1 TABLE OF CONTENTS (Cont) PAGE BASES....................................................................................................................... I B 3.1-0 BASES FOR RADIOACTIVE EFFLUENT INSTRUMENTATION............... I B 3.1-1 BASES FOR RADIOACTIVE EFFLUENTS...................................................... ! B 3.1-2 Liquid Concentration......................................................................................... 1 B 3.1-2 Liquid Dose........................................................................................................... 1 B 3.1-3 Gaseous Dose Rate.............................................................................................. 1 B 3.1-4 Dose-Noble Gases................................................................................................ 1 B 3.1-5 Dose-lodine-131, lodine-133, Tritium, and Radionuclides in Particulate Form....................... ;.................................................................. ! B 3.1-6 Total Dose-Uranium Fuel Cycle........................................................................ 1 B 3.1-7 BASES FOR RADIOACTIVE EFFLUENT TREATMENT SYSTEMS............ ! B 3.1-8 Liquid Rad*waste Treatm_ent System.......................................................-........... 1 B 3.1-8 Gaseous Effluent Treatment Systems................................................................. ! B 3.1-8 BASES FOR :MARK I CONTAIN~IENT.............................................................. 1 B 3.1-9 BASES FOR LIQUID WASTE HOLDUP TANKS.............................................. 1 B 3.1-9 BASES FOR RADIOLOGICAL ENVIRONMENTAL l\\:IONITORING PROGRAl\\I........................................................................... IB 3.1-10 BASES FOR INTERLABORA TORY COMPARISON PROGRAM............... 1 B 3.1-11 BASES FOR LAND USE CENSUS...................................................................... I B3.1-12 Not Used ADMINISTRATIVE CONTROLS...............................".......................................... I 6.0-1 Reporting Requirements....................................................................................... I 6.0-2 Special Reports...................................................................................................... I 6.0-4 lV CY-NM-170-301 Revision 36 May2017
ODCM - NINE MILE POINT UNIT 1 TABLE OF CONTENTS (Cont) PA.RT II - Calculational l\\tlethodologies....................................................................................................... II 1 1.0 LIQUID EFFLUENTS..................................................................................................................... II 2 1.1 1.1.1 1.1.2 1.1.3 1.1.4 1.1.4.1 1.1.4.2 1.1.4.3 1.1.4.4 1.1.4.5 1.1.4.6 1.2 1.3 1.3.1 1.3.2 Setpoint Determinations.............................................................................................. II 2 Basis............................................................................................................................... II 2 Service Water System Effluent Line Alarm Setpoint................................................ II 2 Liquid Rad waste Effluent Line Alarm Setpoint........................................................ II 3 Discussion...................................................................................................................... II 5 Control of Liquid Effluent Batch Discharges............................................................ II 5 Simultaneous Discharges of Radioactive Liquids...................................................... II 5 Sample Representativeness.......................................................................................... II 5 Liquid Radlvaste System Operation........................................................................... II 6 Service \\Vater System Contamination........................................................................ II 7 Reactor Building Perimeter Drain Discharges.......................................................... II 7 Liquid Effluent Concentration Calculation............................................................... II 7 Dose Determinations.................................................................................................... II 8 l\\1aximum Dose Equivalent Pathway.......................................................................... II 8 Dose Projections - Determination of Need to Operate the Liquid Radwaste Treatment System....................................... ;............................................................... II 11 2.0 GASEOUS EFFLUENTS.............................................................................................................. II 12 2.1 Setpoint Determinations............................................................................................ II 12 2.1.1 Basis............................................................................................................................. II 12 2.1.2 Stack l\\1onitor Setpoints............................................................................................. II 12 2.1.3 Recombiner Discharge (Off Gas) Monitor Setpoints.............................................. II 14 2.1.4 Emergency Condenser Vent Monitor Setpoint........................................................ II 15 V CY-NM-170-301 Revision 36 May 2017
2.1.5 2.1.5.1 2.1.5.2 2.1.5.3 2.1.5.4 2.1.5.5 2.1.5.6 2.2 2.2.1 2.2.1.1 2.2.1.2 2.2.2 2.2.2.1 2.2.2.2 2.2.2.3 2.2.3 2.3 2.4 ODCM - NINE MILE POINT UNIT 1 TABLE OF CONTENTS (Cont) PAGE Discussion.................................................................................................................... Il 15 Stack Effluent Monitoring System Description....................................................... Il 15 Stack Sample Flow Path - RA GEMS Auxiliary Sample Point.............................. II 15 Stack Sample Flo,v Path - OGESMS........................................................................ II 16 Sample Frequency/Sample Analysis......................................................................... II 16 1-133 and 1-135 Estimates.......................................................................................... II 16 Gaseous Radwaste Treatment System Operation................................................... JI 17 Dose and Dose Rate Determinations......................................................................... II 17 Dose Rate..................................................................................................................... II 18 No hie Gases................................................................................................................. II 19 Tritium, Iodines and Particulates............................................. ;........................... ;... II 20
- Dose.............................................................................................................................. II 22 Noble Gas Air* Dose................................. :.................................................................. II 22 Tritium, Iodines and Particulates............................................................................. II 23 Accumulating Doses *****:............................................................................................. II 24 Dose Projections - Determination of Need to 01>erate Gaseous Radwaste Treatment System and Ventilation Exhaust Treatment System *..*..*..................... II 24 Critical Receptors.................................................................................. ;.... ~.............. ; II 25 Refinement of Offsite Doses Resulting From Emergency Condenser Vent Releases........................................................................................... II 26 VI CY-NM-170-301 Revision 36 May 2017
ODCM - NINE MILE POINT UNIT 1 TABLE OF CONTENTS (Cont) PAGE 3.0 40 CFR 190 REQUIREMENTS.................................................................................................... II 27 3.1 Evaluation of Doses From Liquid Effluents.......................................................... ;.. II 28 3.2 Evaluation of Doses From Gaseous Effluents.......................................................... II 29 3.3 Evaluation of Doses From Direct Radiation............................................................ II 30 3.4 Doses to Membel'.'s of the Public Within the Site Boundary.................................... 1130 4.0 ENVIRONMENTAL MONITORING PROGRAM..................... ;............................................. II 33 4.1 4.2 4.3 Appendix A Appendix B Appendix C Appendix D Sampling Stations................................................ ;...................................................... II 33 Interlaboratory Comparison Program.................-.................................................... Il 33 Capabilities for Thermoluminescent Dosimeters Used for En,ironmental Measurements................................................................................... II 34 Liquid Dose Factor Derivation (Ain1)............................,............................................ Il 75 Plume Shine Dose Factor Derivation (Bi and Vi)..................................................... II 78 Organ Dose Parameters for lodine-131 & 133, Particulates and Tritium (Ri).................,................................................................... II 82 Diagrams of Radioactive Liquid and Gaseous Effluent Treatment Systems and Monitoring Systems........................................................... Il 92 Vll CY-NM-170-301 Revision 36 May 2017
ODCM - NINE MILE POINT UNIT 1 LISTOFTABLES PART I - Radiological Effluent Controls D 3.6.14-1 D 4.6.14-1 D 3.6.14-2 D 4.6.14-2 D 4.6.15-1 D 4.6.15-2 D 3.6.20-1 D 4.6.20-1 D 6.9.3-1 Radioactive Liquid Effluent Monitoring Instrumentation **.* ;................... I 3.1-3 Radioactive Liquid Effluent Monitoring Instrumentation - SR............... I 3.1-5 Radioactive Gaseous Process and Effluent Monitoring Instrumentation.........................................................-*....... ;........................... I 3.1-8 Radioactive Gaseous Process and Effluent Monitoring Instrumentation - SR................................................................................... I 3.1-12 Radioactive Liquid Waste Sampling and Analysis Program -SR.......... I 3.1-16 Radioactive Gaseous Waste Sampling and Analysis ~rogram - SR....... I 3.1-22 Operational Radiological Emironmental Monitoring Program............. I 3.1-34 Detection Capabilities for Environmental Sample Analysis Lower Limit of Detection LLD - SR................................................. ~........ I 3.1-38 Reporting Level for Radioactivity Concentration in Environmental Samples................................................................................ I 6.0-5 PART II - Calculational Methodologies Table 1-1 Tables 2-1 to 2-8 Table 3-1 Table 3-2 Table3-3 Tables 3-4 to 3-22 Table 3-23 Table 5.1 Average Energy Per Disintegration..-.............................................................. 1136 Aiat Values for the NlVIP-1 Facility.................................................................. II 37 Critical Receptor Dispersion Parameters for Ground Level and Elevated Releases.............................................................. II 45 Gamma Air and Whole Body Plume Shine Dose Factors for Noble Gases (Bi and Vi)................................................................. 11 46 Immersion Dose Factors for Noble Gases....................................................... II 47 Dose and Dose Rate Factors (Ri)..................................................................... 11 48 Parameters for the Evaluation of Doses to Real Members of the Public from Gaseous and Liquid Effluents............................................................................................................. II 67 Nine Mile Point Nuclear Station Radiological Environmental Monitoring Program Sampling Locations............................................................................................................ II 68 Vlll CY-NM-170-301 Revision 36 May2017
ODCM - NINE MILE POINT UNIT 1 LIST OF FIGURES
- Figure 5.1-1 Nine l\\'lile Point On-Site l\\'lap.......................................................................... 11 72 Figure 5.1-2 Nine l\\'lile Point Offsite l\\.1ap............................................................................ 11 73 Figure 5.1.3-1 Site Boundaries................................................................................................. 1174 Figure D-0 Piping Instrument and Equipment Symbols.................................................... D-0 Figure D-1 Radioactive \\Vaste Disposal............................................................................... D-1 Figure D-2 Stm Packing, Exhauster, and Recombiner....................................................... D-2 Figure D-3 Reactor Building Vent System........................................................................... D-3 Figure D-4
\\Vaste Disposal Building Vent System.............................................................. D-4 Figure D-5 Nl\\'IP-1 Stack....................................................................................................... D-5 Figure D-6 Offgas Building Vent System............................................................................. D-6 Figure D-7 This Page/Figure Deleted Figure D-8 Stack Sample and Sample Return..................................................................... D-8 Figures D-9, D-10 These Pages/Figures Deleted Figure D-11 OGESl\\'IS Schematic................................................................................. ;....... D-11 lX CY-NM-170-301 Revision 36 May2017
INTRODUCTION The Offsite Dose Calculation Manual (ODCM) provides the methodology to be used for demonstrating compliance with 10 CFR 20, 10 CFR 50, and 40 CFR 190. The contents of the ODCM are based on Draft NUREG-0472, Revision 3, "Standard Radiological Effluent Technical Specifications for Pressurized Water Reactors," September 1982; Draft NUREG-0473, Revision 2, "Radiological Effluent Technical Specifications for BWR's", July 1979; NUREG 0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants," October 1978; the several Regulatory Guides referenced in these documents; and, communication with the NRC staff. Should it be necessary to revise the ODCM, these revisions will be made in accordance with Technical Specifications. The Offsite Dose Calculation Manual (ODCM) is a supporting document of the Technical Specifications Section 6.5.1, "Offsite Dose Calculation Manual." The previous Limiting Conditions for Operation that were contained in the Radiological Effluent Technical Specifications are now transferred to the ODCM as Radiological Effluent Controls..The ODCM contains two parts: Radiological Effluent Controls Part I; and Calculational Methodologies, Part II. Radiological Efflu,ent Controls, Part I, includes the following: ( 1) The Radioactive Effluent Controls and Radiological Environmental Monitoring Programs required by Technical Specifications 6.5.3, "Radioactive Effluent Controls Program" and 6.5.1, "Offsite Dose Calculation Manual", respectively, and (2) descriptions of the information that should be included in the Annual Radiological Environmental Operating and Radioactive Effluent Release Reports required by Technical Specifications 6.6.2, "Annual Radiological Environmental Operating Report" and 6.6.3 "Radioactive Effluent Release Report". Calculational Methodologies, Part II, describes methodology and parameters to be used in the calculation of liquid and gaseous effluent monitoring instrumentation alarm/trip setpoints and the calculation of offsite doses due to radioactive liquid and gaseous effluents. The ODCM also contains a list and graphical description of the specific sample locations for the radiological environmental monitoring program, and liquid and gaseous radwaste treatment system configurations. X CY-NM-170-301 Revision 36 May 2017
PART I - RADIOLOGICAL EFFLUENT CONTROLS I CY-NM-170-301 Revision 36 May 2017
PART I-RADIOLOGICAL EFFLUENT CONTROLS Section 1.0 I 1.0-0 Definitions CY-NM-170-301 Revision 36 May 2017
1.0 DEFINITIONS NOTE: DEFINITIONS 1.0 Technical Specifications defined terms and the following additional defined terms are applicable throughout these controls and bases. Functional (Functionality) Functionality is an attribute of Structures, Systems, or Components (SSCs) that is not controlled by Technical Specifications. An SSC shall be functional or have functionality when it is capable of performing its specified function as set forth in the Current Licensing Basis (CLB). Functionality does not apply to specified safety functions, but does apply to the ability of non-Technical Specifications SSCs to perform specified support functions. Gaseous Radwaste Treatment System A gaseous radwaste treatment system is any system designed and installed to reduce radioactive gaseous effluents by collecting main condenser offgas and providing for delay or holdup for the purpose of reducing the total. radioactivity prior to release to the environment. Member(s) of the Public Member(s) of the public shall include persons who are not occupationally associated with the Nine Mile Point Nuclear Station. This category does not include employees of owners and operators of Nine Mile Point Nuclear Station and James A. Fitzpatrick Nuclear Power Plant, their contractors or vendors who are occupationally associated with Nine Mile Point Unit 1. Also excluded from this category are persons who enter the site to service equipment or to make deliveries. This category does include persons who use portions of the site for recreational, occupational, or other purposes not associated with Nine Mile Point Unit 1. Milk Sampling Location A milk sampling location is that location where 10 or more head of milk animals are available for the collection of milk samples. I 1.0-1 CY-NM-170-301 Revision 36 May2017
Offsite Dose Calculation Manual (ODCM) DEFINITIONS 1.0 The Offsite Dose Calculation Manual shall contain the current methodology and parameters used in the calculation of offsite doses due to radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring alarm/trip setpoints, and in the conduct of the environmental radiological monitoring program. The ODCM shall also contain the radioactive effluent controls and radiological environmental monitoring activities, and descriptions of the information that should be included in the Annual Radiological Environmental Operating and Radioactive Effluent Release Reports required by Technical Specifications 6.6.2, "Annual Radiological Environmental Operating Report" and 6.6.3, "Radioactive Effluent Release Report", and Controls D 6.9.1.d and D 6.9.1.e. Purge - Purging Purge or purging is the controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration, or other operating condition, in such a manner that replacement air or gas is required to purify the confinement. The purge is completed when the oxygen concentration exceeds 19.5 percent. Site Boundary The site boundary shall be that line around the Nine Mile Point Nuclear Station beyond which the land is neither owned, leased, nor otherwise controlled by the owners and operators of Nine Mile Point Nuclear Station and James A. Fitzpatrick Nuclear Power Plant. Source Check A source check shall be the qualitative assessment of channel response when the channel sensor is exposed to a source of increased radioactivity. Unrestricted Area The unrestricted area shall be any area at or beyond the site boundary access to which is not controlled by the owners and operators of Nine Mile Point Nuclear Station and James A. Fitzpatrick Nuclear Power Plant for purposes of protection of individuals from exposure to radiation and radioactive materials, or any area within the site boundary used for residential quarters or for industrial, commercial, institutional, and/or recreational purposes. That area outside the restricted area (10 CFR 20.1003) but within the site boundary will be controlled by the owner as required. I 1.0-2 CY-NM-170-301 Revision 36 May2017
Ventilation Exhaust Treatment System DEFINTIONS 1.0 A ventilation exhaust treatment system is any system designed and installed to reduce gaseous radioiodine or radioactive material in particulate form in effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters for the purpose of removing iodines or particulates from the gaseous exhaust stream prior to the release to the environment. Such a system is not considered to have any effect on noble gas effluents. Engineered Safety Feature (ESF) atmospheric cleanup systems are not considered to be ventilation exhaust treatment system components. Venting Venting is the controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration, or other operating condition, in such a manner that replacement air or gas is not provided or required during venting. Vent, used in system names, does not imply a venting process. I 1.0-3 CY-NM-170-301 Revision 36 May 2017 J
PART I - RADIOLOGICAL EFFLUENT CONTROLS Sections 3.0/4.0 I 3.0-0 Applicability CY-NM-170-301 Revision 36 May2017
3.0 4.0 CONTROLS APPLICABILITY 3.0/4.0 The Offsite Dose Calculation Manual (ODCM) Part I, Radiological Effluent Controls, is subject to Technical Specifications Section 3.0 requirements, as applicable. SURVEILLANCE REQUIREMENTS The ODCM Part I, Radiological Effluent Controls, is subject to Technical Specifications Section 4_.0 requirements, as applicable. I 3.0-1 CY-NM-170-301 Revision 36 May 2017
c CONTROLS DLCO 3.6.14 RADIOACTIVE EFFLUENT INSTRUMENTATION Applicability: Applies to the functionality of plant instrumentation that monitors plant effluents. Objective: To assure the functionality of instrumentation to monitor the release of radioactive plant effluents. Specification:
- a.
Liquid Effluent The radioactive liquid effluent monitoring instru-mentation channels shown in Table D 3;6.14-1 shall be functional with their alarm setpoints set to ensure that the limits of Control DLCO 3.6.15.a.1 are not exceeded. The alarm setpoints of these channels shall be determined and adjusted in accordance with the methodology and parameters in Part II. With a radioactive liquid effluent monitoring instrumentation channel alarm setpoint less conservative than a value which will ensure that the limits of DLCO 3.6.15.a.1 are met, immediately suspend the release of radioactive liquid effluents monitored by the affected channel, or declare the channel nonfunctional, or change the setpoint so it is acceptably conservative. RADIOACTIVE EFFLUENT INSTRUMENTATION - LIQUID D 3/4.6.14 SURVEILLANCE REQUIREMENT DSR 4.6.14 RADIOACTIVE EFFLUENT INSTRUMENTATION Applicability: I 3.1-1 Applies to the surveillance of instrumentation that monitors plant effluents. Objective: To verify operation of monitoring instrumentation. Specification:
- a.
Liquid Effluent Each radioactive liquid effluent monitoring instrumentation channel shall be demonstrated functional by performance of the sensor check, source check, instrument channel calibration and channel test operations at the frequencies shown in Table D 4.6.14-1. Records - Auditable records shall be maintained, in accordance with procedures in Part II, of all radioactive liquid effluent monitoring instrumentation alarm setpoints. Setpoints and setpoint calculations shall be available for review to ensure that the limits of Control DLCO 3.6.15.a.1 are met. CY-NM-170-301 Revision 36 May2017
CONTROLS With less than the minimum number of radioactive liquid effluent monitoring instrumentation channels functional, take the action shown in Table D 3.6.14-1. Restore the instruments to functional status within 30 days, or outline in the next Radioactive Effluent Release Report the cause of the nonfunctionality and how the instruments were or will be restored to functional status. I3.1-2 RADIOACTIVE EFFLUENT INSTRUMENTATION - LIQUID D 3/4.6.14 SURVEILLANCE REQUIREMENT CY-NM-170-301 Revision 36 May2017
TABLED 3.6.14-1 RADIOACTIVE EFFLUENT INSTRUMENTATION-LIQUID D 3/4.6.14 RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION Instrument
- 1.
Gross Radioactivity Monitors(a) A. Liquid Radwaste Effluent Line B. Service Water System Effluent Line
- 2.
Flow Rate Measurement Devices A. Liquid Radwaste Effluent Line B. Discharge Canal
- 3.
Tank Level Indicating Devices(g) A. Outside Liquid Radwaste Storage Tanks
- Pumps curves or rated capacity will be utilized to estimate flow.
Minimum Channels Functional 1 (c) 1 (d) 1(e) 1<fJ I3.l-3 Applicability At all times(b) At all times At all times At all times CY-NM-170-301 Revision 36 May 2017
RADIOACTIVE EFFLUENT INSTRUMENTATION - LIQUID , D 3/4.6.14 NOTES FOR TABLED 3.6.14-1 (a) Provide alarm, but do not provide automatic termination of release. (b) An operator shall be present in the Radwaste Control Room at all times during a release. (c) With the number of channels functional less than required by the minimum channels functional requirement, effluent releases may continue provided that prior to initiating a release:
- 1.
At least two independent samples are analyzed in accordance with Specification DSR 4.6.15.a, and
- 2.
At least two technically qualified members of the Facility Staff independently verify the release rate calculations and discharge line valving. Otherwise suspend release of radioactive effluents via this pathway. (d) With the number of channels functional less than required by the minimum channels functional requirement, effluent releases via this pathway may continue provided that, at least once per 12 hours, grab samples are collected and analyzed for gamma radioactivity at a lower limit of detection of at least 5x10-7 microcurie/ml. (e) During discharge, with the number of channels functional less than required by the minimum channels functional requirement, effluent releases via this pathway may continue provided the flow rate is estimated at least once per 4 hours during actual releases. (f) With the number of channels functional less than required by the minimum channels functional requirement, liquid additions to this tank may continue provided the tank liquid level is estimated during liquid additions to the tank. (g) Tanks included in this specification are those outdoor tanks that are not surrounded by liners, dikes or walls capable of holding the tank contents. (h) Deleted. (i) Monitoring will be conducted continuously by alternately sampling the reactor building and turbine building service water return lines for approximately 15-minute intervals. 13.1-4 CY-NM-170-301 Revision 36 May 2017
RADIOACTIVE EFFLUENT INSTRUMENTATION - LIQUID D 3/4.6.14 TABLE D 4.6.14-1 RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION Surveillance Requirement Instrument
- 1.
Gross Beta or Gamma Radioactivity Monitors*
- a.
Liquid Radwaste Effluent Line
- b.
Service Water Effluent Line
- 2.
Flow Rate Measurement Devices
- a.
Liquid Radwaste Effluent Line
- b.
Discharge Cana1<ct)
- 3.
Tank Level Indicating Devices<e)
- a. Outside Liquid Radwaste Storage Tanks Sensor Check Once/day*
Once/day Once/dayf c) None Once/day** Source Check<fl Once/discharge* Once/92 days None None None Required prior to removal of blank flange in discharge line and until blank flange is replaced.
- During liquid addition to the tank.
I 3.1-5 Channel Test Once/3 months(a)* Once/184 days(a) None None Once/3 months Channel Calibration Once/year<b}* Once/24 months(b) Once/24 months* Once/year Once/18 months CY-NM-170-301 Revision 36 May 2017
RADIOACTIVE EFFLUENT INSTRUMENTATION - LIQUID D 3/4.6.14 NOTES FOR TABLED 4.6.14-1 (a) The channel test shall also demonstrate that control room alarm annunciation occurs if any of the following conditions exist:
- 1.
Instrumentation indicates measured levels above the alarm setpoint.
- 2.
Instrument indicates a downscale failure.
- 3.
Instrument controls not set in operate mode. (b) The channel calibration shall be performed using one or more reference standards certified by the National Institute of Standards and Technology (NIST), or using standards that are traceable to the NIST or using actual samples of liquid waste that have been analyzed on a system that has been calibrated with NIST traceable sources. These standards shall permit calibrating the system over its intended range of energy and measurement. (c) Sensor check shall consist of verifying indication of flow during periods of release. Sensor check shall be made at least once per 24 hours on days on which continuous, periodic or batch releases are made. (d) Pump performance curves or rated data may be used to estimate flow. (e) Tanks included in this specification are those outdoor tanks that are not surrounded by liners, dikes or walls capable of holding the tank contents. (f) Source check may consist of an installed check source, response to an external source, or (for liquid radwaste monitors) verification within 30 minutes of commencing discharge of monitor response to effluent. I 3.1-6 CY-NM-170-301 Revision 36 May2017
CONTROLS
- b.
Gaseous Process and Effluent The radioactive gaseous process and effluent monitoring instrumentation channels shown in Table D 3.6.14-2 shall be functional. The Offgas process monitor alarm setpoint shall be set to ensure that the limits of Technical Specification 3.6.15 are not exceeded. The Effluent monitor alarm setpoints shall be set to ensure that the limits of Control DLCO 3.6.15.b.1 are not exceeded. The alarm setpoints of these channels shall be determined and adjusted in accordance with the methodology and parameters in Part II. With a radioactive gaseous process and effluent monitoring instrumentation channel alarm setpoint less conservative than required by the above specification, immediately suspend the release of radioactive gaseous effluents monitored by the affected channel, or declare the channel nonfunctional, or change the setpoint so it is acceptably conservative. With less than the minimum number of radioactive gaseous process and effluent monitoring instrumentation channels functional, take the action shown in Table D 3.6.14-2. Restore the instruments to functional status within 30 days or outline in the next Radioactive Effluent Release Report the cause of the nonfunctionality and how the instruments were or will be restored to functional status. I 3.1-7 RADIOACTIVE EFFLUENT INSTRUMENTATION-GASEOUS D 3/4.6.14 SURVEILLANCE REQUIREMENT
- b.
Gaseous Process and Effluent Each radioactive gaseous process and effluent monitoring instrumentation channel shall be demonstrated functional by performance of the sensor check, source check, instrument channel calibration and instrument channel test operations at the frequencies shown in Table D 4.6.14-2. Auditable records shall be maintained of the calculations made, in accordance with procedures in Part II, of radioactive gaseous process and effluent monitoring instrumentation alarm setpoints. Setpoints and setpoint calculations shall be available for review to ensure that the limits of Control DLCO 3.6.15.b.1 are met. CY-NM-170-301 Revision 36 May 2017
I
- 1.
- 2.
TABLED 3.6.14-2 RADIOACTIVE EFFLUENT INSTRUMENTATION - GASEOUS D 3/4.6.14 RADIOACTIVE GASEOUS PROCESS AND EFFLUENT MONITORING INSTRUMENTATION Instrument Stack Effluent Monitoring
- a.
Noble Gas Activity Monitors (1) High Range (2) Low Range
- b.
Iodine Sampler Cartridge C. Particulate Sampler Filter
- d.
Sampler Flow Rate Measuring Device
- e.
Stack Gas Flow Rate Measuring Device Deleted At all times. Note Deleted. Minimum Channels Functional 2 1 1 1 1 1 I 3.1-8 Applicability Action (a) (i) (b) (b) (c) (c), (d) CY-NM-170-301 Revision 36 May2017
RADIOACTIVE EFFLUENT INSTRUMENTATION - GASEOUS D 3/4.6.14 TABLED 3.6.14-2 (cont'd) RADIOACTIVE GASEOUS PROCESS AND EFFLUENT MONITORING INSTRUMENTATION Instrument
- 3.
Condenser Air Ejector Process , Monitor (Offgas System Recombiner Discharge)
- a.
Noble Gas Activity Monitor
- b.
Offgas System Flow Rate Measuring Device
- 4.
Emergency Condenser System Effluent
- a.
Noble Gas Activity Monitor Minimum Channels Functional 2 1 1 per vent During operation of the main condenser air ejector Applicability Action (g) (c) {h) During power operating conditions and whenever the reactor coolant temperature is greater than 212°F except for hydrostatic testing with the reactor not critical. 13.1-9 CY-NM-170-301 Revision 36 Jv:lay 2017
RADIOACTIVE EFFLUENT INSTRUMENTATION-GASEOUS D 3/4.6.14 NOTES FOR TABLE D 3.6.14-2 (a) (1) With the number of channels functional 1 less than required by the minimum channels functional requirement, effluent releases via this pathway may continue provided: (a) The nonfunctional channel is placed in the tripped condition, OR (b) Vent and Purge valves are closed and administratively controlled, OR (c) Primary containment integrity is not required. (2) With the number of channels functional 2 less than required by the minimum channels functional requirement, effluent releases via this pathway may continue provided grab samples are taken once per 12 hours and these samples are analyzed for gross activity within 24 hours. (b) With the number of channels functional less than required by the minimum channels functional requirements, effluent releases via this pathway
- may continue provided that samples are continuously collected with auxiliary sampling equipment starting within 8 hours of discovery in accordance with the requirements of Table D 4.6.15-2. When OGESMS and the auxiliary sampling equipment are both non-functional, of Chemistry procedure N1-CSP-V304 may be used for obtaining continuous particulate and iodine samples.
(c) With the number of channels functional less than required by the minimum channels functional requirements, effluent releases via this pathwa/ may continue provided the flow rate is estimated once per 8 hours. (d) Stack gas flow rate may be estimated by exhaust fan operating configuration. * (e) Deleted (f) Deleted I 3.1-10 CY-NM-170-301 Revision 36 May2017
RADIOACTIVE EFFLUENT INSTRUMENTATION-GASEOUS D 3/4.6.14 NOTES FOR TABLED 3.6.14-2 (cont'd) (g) With one or more channels nonfunctional: (1) Place the nonfunctional channel in the tripped condition within 12 hours OR (2) (a) Take grab samples within 12 hours and once per 12 hours thereafter AND (b) Analyze samples for gross activity within 24 hours of sampling completion. AND (3) Restore nonfunctional channel(s) to FUNCTIONAL status within 30 days. 0) (h) With the number of channels functional less than required by the minimum channels functional requirements, steam release via this pathway may commence or continue provided vent pipe radiation dose rates are monitored.once per four hours. (i) With the number of channels functional less than required by the minimum channels functional requirement, effluent releases via this pathway may continue provided grab samples are taken once per 12 hours and these samples are analyzed for gross activity within 24 hours. U) If nonfunctional channel(s) not restored within specified time, explain why the inoperability was not corrected in a timely manner in the next Radioactive Effluent Release Report. 13.1-11 CY-NM-170-301 Revision 36 May2017
- 1.
- 2.
- 3.
- 4.
TABLED 4.6.14-2 RADIOACTIVE EFFLUENT INSTRUMENTATION-GASEOUS D 3/4.6.14 RADIOACTIVE GASEOUS PROCESS AND EFFLUENT MONITORING INSTRUMENTATION Instrument Stack Effluent Monitoring System
- a. Noble Gas Activity Monitors (High Range and Low Range)
- b. Iodine Sampler Cartridge C.
Particulate Sampler Filter
- d. Sampler Flow Rate Measuring Device
- e. Stack Gas Flow Rate Measuring Device Deleted Condenser Air Ejector Process Monitor (Offgas System Recombiner Discharge)
- a. Noble Gas Activity Monitor
- b. Offgas System Flow Rate Measuring Device Emergency Condenser System Effluent
- a.
Noble Gas Activity Monitor Surveillance Requirements Sensor Check Source Check Once/day(al Once/92 days None None None None Once/dayta) None Once/day None Once/day(fl Once/92 days Once/day<fl None Once/day<hJ Once/92 days 13.1-12 Channel Test Once/184 days(9l None None None None Once/24 months<c) None Once184 days<9J Channel Calibration Once/24 months(bl None None Once/24 months Once/24 months Once/24 months(bl Once/24 months Once/24 months<bJ CY-NM-170-301 Revision 36 May 2017
RADIOACTIVE EFFLUENT INSTRUMENTATION-GASEOUS D 3/4.6.14 NOTES FOR TABLED 4.6.14-2 (a) At all times. (b) The channel calibration shall be performed using one or more of the reference standards certified by the National Institute of Standards and Technology (NIST), standards that are traceable to the NIST or using actual samples of gaseous effluent that have been analyzed on a system that has been calibrated with NIST traceable sources. These standards shall permit calibrating the system over its intended range of energy and measurement. (c) The channel function test shall demonstrate that control room alarm annunciation occurs if either of the following conditions exist:
- 1) Instrument indicates measured levels above the Hi or Hi Hi alarm setpoint.
- 2) Instrument indicates a downscale failure.
The channel function test shall also demonstrate that automatic isolation of this pathway occurs if either of the following conditions exist:
- 1) Instruments indicate two channels above Hi Hi alarm setpoint.
- 2) Instruments indicate one channel above Hi Hi alarm setpoint and one channel downscale.
(d) Deleted (e)
- Deleted (f)
During operation of the main condenser air ejector. (g) The channel test shall produce upscale and downscale annunciation. (h) During power operating conditions and whenever the reactor coolant temperature is greater than 212°F except for hydrostatic testing with the reactor not critical. I3.1-13 CY-NM-170-301 Revision 36 May 2017
CONTROLS DLCO 3.6.15 RADIOACTIVE EFFLUENTS Applicability: Appi'ies to the radioactive effluents from the station. Objective: To assure that radioactive material is not released to the environment in any uncontrolled manner and is within the limits of 1 OCFR20 and 1 OCFR50 Appendix I. Specification:
- a.
Liquid (1) Concentration The concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to ten times the concentrations specified in 10CFR Part 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2 x 10-4 microcuries/ml total activity. Should the concentration of radioactive material released in liquid effluents to unrestricted areas exceed the above limits, restore the concentration to within the above limits immediately. 13.1-14 RADIOACTIVE EFFLUENTS-LIQUID CONCENTRATION D 3/4.6.15 SURVEILLANCE REQUIREMENT DSR 4.6.15 RADIOACTIVE EFFLUENTS Applicability: Appli~s to the periodic test and recording requirements of the station process effluents. Objective: To ascertain that radioactive effluents from the station are within 'the allowable values of 1 OCFR20, Appendix B and 1 OCFR50, Appendix I. Specification:
- a.
Liquid (1) Concentration Radioactive liquid wastes shall be sampled and analyzed according to the sampling and analysis program of Table D 4.6.15-1. The results of the radioactivity analyses shall be used in accordance with the methodology and parameters in Part II to assure that the concentrations at the point of release are maintained within the limits of Control DLCO 3.6.15.a.(1 ). CY-NM-170-301 Revision 36 May 2017
CONTROLS
- (2)
Dose The dose or dose commitment to a member of the public from radioactive materials in liquid effluents released, from each reactor unit, to unrestricted areas (see Figures 5.1-1) shall be limited: (a) During any calendar quarter to less than or equal to 1.5 mrems to the total body and to less than or equal to 5 mrems to any organ, and (b) During any calendar year to less than or equal to 3 mrems to the total body and to less than or equal to 10 mrems to any organ. With the calculated dose from the release of radioactive materials in liquid effluents exceeding any of the above limits, prepare and submit to the Commission within 30 days, pursuant to Control D 6.9.3, a Special Report that identifies the cause(s) for exceeding the limit(s) and defines the corrective actions that have been taken to reduce the releases and the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the above limits. 13.1-15 RADIOACTIVE EFFLUENTS - LIQUID DOSE D 3/4.6.15 SURVEILLANCE REQUIREMENT (2) Dose Cumulative dose contributions from liquid effluents for the current calendar quarter and the current calendar year shall be determined in accordance with the methodology and parameters in Part II monthly. CY-NM-170-301
- Revision 36 May 2017
A. B. C. TABLED 4.6.15-1 RADIOACTIVE EFFLUENTS - LIQUID D 3/4.6.15 RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Sampling Frequency Liquid Release Type Batch Waste(b) Tanks Each Batch Each Batch<dJ Each Batch Each Batch Service Water System Once/month<tJ Effluent Once/quarter<!) Reactor Building Perimeter Once/quarter Drain Completed prior to each release. Surveillance Requirement Minimum Analysis Frequency Type of Activity Analysis Each Batch Principal Gamma(cJ Emitters 1-131 Each Batch(ct) Dissolved and Entrained Gases (Gamma Emitters) Monthly Composite<eJ H-3 Gross Alpha Quarterly Composite(e) Sr-89, Sr-90 Fe-55 Once/month<1l Principal Gamma<c) Emitters 1-131 Dissolved and Entrained Gases H-3 Gross Alpha Once/quarter<1) Sr-89, Sr-90 Fe-55 Quarterly Composite<e) Principal Gamma(c) Emitters 1-131 H-3 Gross Alpha Sr-89, Sr-90 Fe-55, Ni-63 I3.l-l6 Lower Limit(a) of Detection (LLD) (µCi/ml) 5 X 10-7 1 X 10-6 1 X 10-5 1 X 10-5 1 X 10-7. 5 X 10-8 1 X 10-6 5 X 10-7 1 X 10-6 1 X 10-5 1x1ff5
- 1 X 10-7 5 X 10-8 1 X 10-6 5 X 10-7 1 X 10-6 1 X 10-5 1 X 10-7 5 X 10-8 1 X 10-6 CY-NM-170-301 Revision 36 May 2017
NOTES FOR TABLED 4.6.15-1 RADIOACTIVE EFFLUENTS - LIQUID D 3/4.6.15 (a) The LLD is defined, for purposes of these specifications, as the smallest concentration of radioactive material in a sample that will yield a net count above system background that will be detected with 95 percent probability with only 5 percent probability of falsely concluding that a blank observation represents a "real" signal. For a particular measurement system which may include radiochemical separation: Where: LLD= 4.66 Sb E*V*2.22 x 106*Y*exp (-1sllt) LLD is the "a priori" lower limit of detection as defined above, as microcuries per unit mass or volume, Sb is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate, as counts per minute, E is the counting efficiency, as counts per disintegration, V is the sample size in units of mass or volume, 2.22 x 106 is the number of disintegrations per minute per microcurie, Y is the fractional radiochemical yield, when applicable, 'k is the radioactive decay constant for the particular radionuclide, and Llt for plant effluents is the elapsed time between the midpoint of sample collection and time of counting. Typical values of E, V, Y and Lit should be used in the calculation. It should be recognized that the LLD is defined as a before the fact limit representing the capability of a measurement system and not as an after the fact for a particular measurement. 13.1-17 CY-NM-170-301 Revision 36 May2017
NOTES FOR TABLED 4.6.15-1 RADIOACTIVE EFFLUENTS - LIQUID D 3/4.6.15, (b) A batch release is the discharge of liquid wastes of a discrete volume. Prior to sampling for analyses, each batch shall be isolated and then thoroughly mixed to assure representative sampling. (c) The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141 and Ce-144. This list does not mean that only these nuclides are to be considered. Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report. (d) If more than one batch is released in a calendar month, only one batch need be sampled and analyzed during that month. (e) A composite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged and in which the method of sampling employed results in a specimen that is representative of the liquids released. (f) If the alarm setpoint of the service water effluent monitor, as determined by the method presented in Part II, is exceeded, the frequency of sampling shall be increased to daily until the condition no longer exists. Frequency of analysis shall be increased to daily for principal gamma emitters (including dissolved and entrained gases) and an incident composite for H-3, gross alpha, Sr-89, Sr-90 and Fe-55. I 3.1-18 CY-NM-170-301 Revision 36 May 2017
CONTROLS
- b.
Gaseous (1) Dose Rate The dose rate due to radioactive materials released in gaseous effluents from the site to areas at or beyond the site boundary shall be limited to the following: (a) For noble gases: Less than or equal to 500 mrems/year to the whole body and less than or equal to 3000 mrems/year to the skin, and (b) For iodine-131, iodine-133,tritium and all radionuclides in particulate form with half lives greater than 8 days: Less than or equal to 1500 mrems/year to any organ. With the dose rate(s) exceeding the above limits, without delay restore the release rate to within the above limits(s). I 3.1-19 RADIOACTIVE EFFLUENTS - GASEOUS DOSE RATE D 3/4.6.15 SURVEILLANCE REQUIREMENT
- b.
- Gaseous (1)
Dose Rate The dose rate due to noble gases in gaseous effluents shall be determined to be within the limits of Control DLCO 3.6.15 in accordance with the methodology and parameters in Part II. The dose rate due to iodine-131, iodine-133, tritium and all radionuclides in particulate form with half lives greater than 8 days in gaseous effluents shall be determined to be within the limits of Control DLCO 3.6.15 in accordance with methodology and parameters in Part II by obtaining representative samples and performing analyses in accordance with the sampling and analysis program specified in Table D 4.6.15-2. CY-NM-170-301 Revision 36 May 2017
(2) CONTROLS Air Dose The air dose due to noble gases released in gaseous effluents, from each reactor unit, to areas beyond the site boundary shall be limited to the following: (a) During any calendar quarter: Less than or equal to 5 milliroentgen for gamma radiation and less than or equal to 10 mrads for beta - radiation and, (b) During any calendar year: Less than or equal to 10 milliroentgen for gamma radiation and less than or equal to 20 mrads for beta radiation. With the calculated air dose from radioactive noble gases in gaseous effluents exceeding any of the above limits, prepare and submit to the Commission within 30 days, pursuant to Control D 6.9.3, a Special Report that identifies the cause(s) for exceeding the limit(s) and defines the corrective actions that have been taken to reduce the releases and the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the above limits. .I 3.1-20 RADIOACTIVE EFFLUENTS - GASEOUS DOSE D 3/4.6.15 SURVEILLANCE REQUIREMENT (2) Air Dose Cumulative dose contributions for the current calendar quarter and current calendar year for noble gases shall be determined monthly in accordance with the methodology and parameters in Part II. CY-NM-170-301 Revision 36 May2017
(3) CONTROLS Tritium, Iodines and Particulates The dose to a member of the public from iodine-131, iodine-133, tritium and all radionuclides in particulate form with half lives greater than 8 days in gaseous effluents released, from each re.actor unit, to areas beyond the site boundary shall be limited to the following: (a) During any calendar quarter: Less than or equal to 7.5 mrems to any organ and, (b) During any calendar year: Less than or equal to 15 mrems to any organ. With the calculated dose from the release of iodine-131, iodine-133, tritium and radionuclides in particulate form with half lives greater than 8 days, in gaseous effluents exceeding any of the above limits, prepare and submit to the Commission within 30 days, pursuant to Control D 6.9.3, a Special Report that identifies the cause(s) for exceeding the limit and defines the corrective actions that have been taken to reduce the releases and the proposed corrective actions to be taken to assure that subsequent - releases.will be in compliance with the above limits. I 3.1-21 RADIOACTIVE EFFLUENTS - GASEOUS DOSE D 3/4.6.15 SURVEILLANCE REQUIREMENT (3) Tritium, Iodines and Particulates Cumulative dose contributions for the current calendar quarter and current calendar year for iodine-131, iodine-133, tritium and radionuclides in particulate form with half lives greater than 8 days shall be determined monthly in accordance with the methodology and parameters in Part 11. CY-NM-170-301 Revision 36 May2017
Gaseous Release Type A. Containment Purge<bl B. Stack C. Stack TABLE D 4.6.15-2 RADIOACTIVE EFFLUENTS - GASEOUS D 3/4.6.15 RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Surveillance Requirements Minimum Sampling Frequency Analysis Frequency Type of Activity Analysis Each Purge Prior to each release Principal Gamma Emitters<c> Grab Sample Each Purge
- Principal Gamma Emitters<c)
H-3 Once/Month(dl Once/Month<dl Principal Gamma Emitters<c> Once/Month<hl Once/Month H-3 Continuous<e) Once/Week<f) 1-131 Charcoal Sample Continuous<e) Once/Week<f) Principal Gamma Emitters<c> Particulate Sample Continuous<eJ Once/Month Composite Gross alpha, Sr-89, Sr-90 Particulate Sample Continuous<e} Noble Gas Monitor Noble Gases, Gross Gamma or Principal Gamma Emitters<cl I 3.1-22 Lower Limit<aJ of Detection (LLD) (µCi/ml) 1 X 104 1 X 104 1 X 10-6 1 X 104 1 X 10-6 1 X 10-12 1 X 10*11 1 X 10-11 1 X 10-5(g) CY-NM-170-301 Revision 36 May2017
(a) The LLD is defined in notation (a) of Table D 4.6.15-1. (b) Purge is defined in Section 1.0. NOTES FOR TABLED 4.6.15-2 RADIOACTIVE EFFLUENTS - GASEOUS D 3/4.6.15 (c) The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Kr-87, Kr-88, Xe-133, Xe-135 and Xe-138 for gaseous emissions and Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, 1-131 and Ce-144 for particulate emissions. This list does not mean that only these nuclides are to be considered. Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report pursuant to Technical Specification 6.6.3, "Radiogctive Effluent Release Report", and Control D 6.9.1. (d) Sampling and analysis shall also be performed following shutdown, startup or an increase on the recombiner discharge monitor of greater t_han 50 percent, factoring out increases due to changes in thermal power level or dilution flow; or when the stack release rate is in excess of 1000 µq/second and steady-state gaseous release rate increases by 50 percent. {j~*
- '\\,
(e) The sample flow rate and the stack flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with Controls DLCO 3.6.15.b.(1).(b) and DLCO 3.6.15.b.(3). (f) When the release rate is in excess of 1000 ~1Ci/sec and steady state gaseous release rate increases by 50 percent, the iodine and particulate collection device shall be removed and analyzed to determine the changes in iodine-131 and particulate release rate. The analysis shall be done daily following each change until it is shown that a pattern exists which can be used to predict the release' rate; after which it may revert to weekly sampling frequency. When samples collected for 24 hours are analyzed, the corresponding LLD's may be increased by a factor of 10. (g) When the continuous Noble Gas Monitor is nonfunctional the LLD for noble gas gamma analysis shall be 1 x 10-4 µCi/cc. (h) Tritium grab samples shall betaken weekly from the station ventilation exhaust (stack) when fuel is offloaded until stable tritium release levels can be demonstrated. I 3.1-23 CY-NM-170-301 Revision 36
- May 2017
C.
- d.
CONTROLS Deleted Uranium Fuel Cycle The annual (calendar year) dose or dose commitment to any member of the public due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be / limited to less than or equal to 25 mrems to the whole body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems. I 3.1-24 RADIOACTIVE EFFLUENTS - MAIN CONDENSER, URANIUM FUEL CYCLE D 3/4.6.15 C.
- d.
.]; SURVEILLANCE REQUIREMENT Main Condenser The radioactivity rate of noble gases at the recombiner discharge shall be continuously monitored in accordance with Table D 3.6.14-2. Uranium Fuel Cycle Cumulative dose contributions from liquid and gaseous effluents shall be determined in accordance with Controls DSR 4.6.15.a.(2), DSR 4.6.15.b.(2) and DSR 4.6.15.b.(3) and in accordance with the methodology and parameters in Part II. CY-NM-170-301 Revision 36 May 2017
CONTROLS With the calculated doses from the release of radioactive materials in liquid or gaseous effluents exceeding twice the limits of Controls DLCO 3.6.15.a(2), DLCO 3.6.15.b(2) and DLCO 3.6.15.b(3), calculations shall be made including direct radiation contributions from the reactor units, the Independent Spent Fuel Storage Installation (ISFSI), and from outside storage tanks to determine whether the above listed 40CFR190 limits have been exceeded. If such is the case, prepare and submit to the Commission within 30 days, pursuant to Control D 6.9.3, a Special Report that defines the corrective action to be taken to reduce subsequent releases to prevent recurrence of exceeding the above limits and includes the schedule for achieving conformance with the above limits. This Special Report, as defined in 10 CFR Part 20.2203(a)(4), shall include an analysis that estimates the radiation exposure (dose) to a member of the public from uranium fuel cycle sources, including all effluent pathways and direct radiation, for the calendar year that includes the release(s) covered by this report. I 3.1-25 RADIOACTIVE EFFLUENTS - URANIUM FUEL CYCLE D 3/4.6.15 SURVEILLANCE REQUIREMENT Cumulative dose contributions from direct radiation from the reactor units, ISFSI, and from radwaste storage tanks shall be determined in accordance with the methodology and parameters in Part II. This requirement is applicable only under conditions set forth in Control DLCO 3.6.15.d. CY-NM-170-301 Revision 36 May2017
CONTROLS It shall also describe levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations. If the estimated dose(s) exceeds the. above limits, and if the release condition resulting in violation of 40CFR Part 190 has not already been corrected, the Special Report shall include a request for a variance in accordance with the provisions of 40CFR 190. Submittal of the report is considered a timely request and a variance is granted until staff action on the request is complete. I 3.1-26 RADIOACTIVE EFFLUENTS - URANIUM FUEL CYLE D 3/4.6.15 SURVEILLANCE REQUIREMENT CY-NM-170-301 Revision 36 May 2017
CONTROLS DLCO 3.6.16 RADIOACTIVE EFFLUENT TREATMENT SYSTEMS Applicability: Applies to the operating status of the liquid and gaseous effluent treatment systems. Objective: To assure functionality of the liquid and gaseous effluent treatment system. Specification:
- a.
Liquid The liquid radwaste treatment system shall be used to reduce the radioactive materials in liquid wastes prior to their discharge when the projected dose due to the liquid effluent, from each unit, to the Unrestricted Areas would exceed 0.06 mrem to the total body or 0.2 mrem to any organ for any batch.
- b.
Gaseous (1) The Gaseous Radwaste Treatment System shall be functional. The Gaseous Radwaste Treatment System shall be used to reduce radioactive materials in gaseous waste prior to their discharge as necessary to meet the requirements of Control DLCO 3.6.15. I 3.1-27 RADIOACTIVE EFFLUENT TREATMENT SYSTEMS D 3/4.6.16 SURVEILLANCE REQUIREMENT DSR 4.6.16 RADIOACTIVE EFFLUENT TREATMENT SYSTEMS Applicability: Applies to the surveillance requirements for the liquid and gaseous effluent treatment systems. Objective: To verify functionality of the liquid and gaseous effluent treatment system. Specification:
- a.
Liquid Doses due to liquid releases to unrestricted areas shall be projected prior to the release of each batch of liquid radioactive waste in accordance with the methodology and parameters in Part II.
- b.
Gaseous (1) Doses due to gaseous releases to areas at or beyond the site boundary shall be calculated in accordance with the methodology and parameters in Part 11. CY-NM-170-301 Revision 36 May,2017
(2) CONTROLS With gaseous radwaste from the main condenser air ejector system being discharged without treatment for more than 7 days, prepare and submit to the Commission within 30 days, pursuant to Control D 6.9.3, a Special Report that identifies the nonfunctional equipment and the reason for its nonfunctionality, actions taken to restore the nonfunctional equipment to functional status, and a summary description of those actions taken to prevent a recurrence. The Ventilation Exhaust Treatment System shall be functional and appropriate portions of this system shall be used to reduce releases of radioactivity when the projected doses in 31 days due to gaseous effluent releases, from each unit, to areas beyond the site boundary would exceed 0.3 mrem to any organ of a member of the public. With radioactive gaseous waste being discharged without treatment and in excess of the above limit, complete a CR evaluation of the degraded condition within 30 days that identifies the nonfunctional equipment, the reason for the nonfunctionality, and plans and schedule to restore the equipment to functional status. I 3.1-28 (2) RADIOACTIVE EFFLUENT TREATMENT SYSTEMS D 3/4.6.16
~-
NOTE: Only required to be met when the Ventilation Exhaust Treatment System is not being fully utilized. Project the doses from the iodine and particulate releases from each unit to areas beyond the Site Boundary at least every 31 days. CY-NM-170-301 Revision 36 May2017
CONTROLS DLCO 3.6.18 MARK I CONTAINMENT Applicability: Applies to the venting/purging of the Mark I Containment. Objective: To assure that the Mark I Containment is vented/purged so that the limits of Controls DLCO 3.6.15.b(1) and DLCO 3.6.15.b(3) are met. Specification: The Mark I Containment drywell shall be vented/ purged through the Emergency Ventilation System unless Controls DLCO 3.6.15.b.(1) and DLCO 3.6.15.b.(3) can be met without use of the Emergency Ventilation System. If these requirements are not satisfied, suspend all venting/purging of the drywell. I 3.1-29 MARK I CONTAINMENT D 3/4.6.18 SURVEILLANCE REQUIREMENT DSR4.6.18 MARK I CONTAINMENT Applicability: Applies to the surveillance requirement for venting and purging of the Mark I Containment when required to be vented/purged through the Emergency Ventilation System. Objective: To verify that the Mark I Containment is vented through the Emergency Ventilation System when required. Specification: The containment drywall shall be determined to be aligned for venting/purging through the Emergency Ventilation System within four hours prior to start of and at least once per 12 hours during venting/purging of the drywall. CY-NM-170-301 Revision 36 May 2017
CONTROLS DLCO 3.6.19 LIQUID WASTE HOLDUP TANKS*
- Applicability:
Applies to the quantity of radioactive material that may be stored in an outdoor liquid waste holdup tank. Objective: To assure that the quantity of radioactive material stored in outdoor holdup tanks does not exceed a specified level. Specification: The quantity of radioactive material contained in an outdoor liquid waste tank shall be limited to less than or equal to 10 curies, excluding tritium and dissolved or entrained noble gases. With the quantity of radioactive material in any such tank exceeding the above limit, immediately suspend all additions of radioactive material to the tank. Within 48 hours reduce the tank contents to within the limit and describe the events leading to this condition in the next Radioactive Effluent Release Report.
- Tanks included in this Control are those outdoor tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents and that do not have tank overflows and surrounding area drains connected to the liquid radwaste treatment system.
I 3.1-30 LIQUID WASTE HOLDUP TANKS D 3/4.6.19 SURVEILLANCE REQUIREMENT DSR 4.6.19 LIQUID WASTE HOLDUP TANKS Applicability: Applies to the surveillance requirements for outdoor liquid waste holdup tanks. Objective: To verify the quantity of radioactive material stored in an outdoor liquid waste holdup tank. Specification: The quantity of radioactive material contained in each of the tanks listed in Control DLCO 3.6.19 shall be determined to be within the limit of Control DLCO 3.6.19 by analyzing a representative sample of the tank's contents at least weekly when radioactive materials are being added to the tank. CY-NM-170-301 Revision 36 May 2017
CONTROLS DLCO 3.6.20 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Applicability: Applies to radiological samples of station environs. Objective: To evaluate the effects of station operations and radioactive effluent releases on the environs and to verify the effectiveness of the controls on radioactive material sources. Specification: The radiological environmental monitoring program shall be conducted as specified in Table D 3.6.20-1. With the radiological environmental monitoring program not being conducted as specified in Table D 3.6.20-1, prepare and submit to the Commission, in the Annual Radiological Environmental Operating Report, a description of the reasons for not conducting the program as required and the
- plans for preventing a recurrence.
Deviations are permitted from the required sample schedule if samples are unobtainable due to hazardous conditions, seasonal unavailability, theft, uncooperative residents or to malfunction of automatic sampling equipment. In the event of the latter, every effort shall be made to complete, corrective action prior to the end of the next sampling period. 13.1-31 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 SURVEILLANCE REQUIREMENT DSR 4.6.20 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM* Applicability: Applies to the periodic sampling and monitoring requirements of the radiological environmental monitoring program. Objective: To ascertain what effect station operations and radioactive effluent releases have had upon the environment. Specification: The radiological environmental monitoring samples shall be collected pursuant to Table D 3.6.20-1 from the specific locations given in the table and figure(s) in Part II and shall be analyzed pursuant to the requirements of Table D 3.6.20-1 and the detection capabilities required by Table D 4.6.20-
- 1.
CY-NM-170-301 Revision 36 May 2017
CONTROLS With the level of radioactivity (as the result of plant effluents), in an environmental sampling medium exceeding the reporting levels of Table D 6.9.3-1 when averaged over any calendar quarter, prepare and submit to the Commission within 30 days from the end of the affected calendar quarter a Special Report pursuant to Control D 6.9.3. The Special Report shall identify the cause(s) for exceeding the limit(s) and define the corrective action(s) to be taken to reduce radioactive effluents so that the potential annual dose to a member of the public is less than the calendar year limits of Controls DLCO 3.6.15.a.(2), DLCO 3.6.15.b.(2) and.DLCO 3.6.15.b.(3). When more than one of the radionuclides in Table D 6.9.3-1 are detected in the sampling medium, this report shall be submitted if: concentration (1) + concentration (2) + limit level (1) limit level (2) ~1.0 When radionuclides other than those in Table D 6.9.3-1 are detected and are the result of plant effluents, this report shall be submitted if the potential annual dose to an individual is equal to or greater than the calendar year limits of Controls DLCO 3.6.15.a.(2), DLCO 3.6.15.b.(2) and DLCO 3.6.15.b.(3). I 3.1-32 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 SURVEILLANCE REQUIREMENT CY-NM-170-301 Revision 36 May2017
CONTROLS This report is not required if the measured level of radioactivity was not the result of plant effluents; however, in such an event, the condition shall be reported and described in the Annual Radiological Environmental Operating Report. With milk or fruit and/or vegetables no longer available at one or more of the sample locations specified in Table D 3.6.20-1, identify locations for obtaining replacement samples and add them to the radiological environmental monitoring program within 30 days. The specific locations from which samples were unavailable may then be deleted from the monitoring program. Identify the cause of the unavailability of samples and identify the new location(s) for obtaining replacement samples in the next Radioactive Effluent Release Report and also include in the report a revised figure(s) and table for Part II reflecting the new location(s). 13.1-33 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 SURVEILLANCE REQUIREMENT CY-NM-170-301 Revision 36 May 2017
Exposure Pathway and/or Sample Radioiodine & Particulates Direct Radiation(e) TABLED 3.6.20-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 OPERATIONAL RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Number of Samples(aJ and Locations Samples from 5 locations:
- 1) 3 Samples from off-site locations in different sectors of the highest calculated site average D/Q
{based on all site licensed reactors)
- 2)
- 3) 1 sample from the vicinity of an established year round community having the highest calculated site average D/Q (based on all site licensed reactors) 1 sample from a control location 10-17 miles
- distant and in a least prevalent wind direction<dl Sampling and Collection Frequency (aJ Continuous sampler operation with sample collection weekly or as required by dust loading, whichever is more frequent 32 stations with two or more dosimeters to be placed as Once per 3 months follows: an inner ring of stations in the general area of the site boundary and an outer ring in the 4 to 5 mile range from the site with a station in each land based sector.* The balance of the stations should be placed in special interest areas such as population centers, nearby residences, schools and in 2 or 3 areas to serve as control stations.
Type of Analysis and Frequency Radioiodine Canisters analyze once/week for 1-131. Particulate Samplers Gross beta radioactivity following filter change, (b) composite (by location) for gamma isotopic analysis<c> once per 3 months, (as a minimum) Gamma dose once per 3 months At this distance, 8 wind rose sectors are over Lake Ontario. 13.1-34 CY-NM-170-301 Revision 36 May2017
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 TABLED 3.6.20-1 (Cont) OPERATIONAL RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway and/or Sample WATERBORNE Surface(tJ Number of Samples(al and Locations
- 1) 1 sample upstream
- 2) 1 sample from the site's downstream cooling water intake Sediment from Shoreline 1 sample from a downstream area with existing or potential recreational value INGESTION Milk
- 1)
Samples from milk sampling locations in 3 locations within 3.5 miles distance having the highest calculated site average D/Q. If there are 1 none, then 1 sample from milking animals in each of 3 areas 3.5-5.0 miles distant having the* highest calculated site average D/Q (based on all site licensed reactors)
- 2) 1 sample from a milk sampling location at a control location (9-20 miles distant and in a least prevalent wind directionictl I 3.1-35 Sampling and Collection Frequency (al Composite sample over 1 month period(9l Twice per year Twice per month, April-December (samples will be collected in January-March if 1-131 is detected in November and December of the preceding year)
Type of Analysis and Frequency Gamma isotopic analysis(cl once/month. Composite for once per 3 months tritium analysis. Gamma isotopic analysis(cl Gamma isotopic(c) and 1-131 analysis twice per month when animals are on pasture (April-December); once/month at other times (January-March) if required CY-NM-170-301 Revision 36 May 2017
Exposure Pathway and/or Sample Fish Food Products RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20
- 1)
- 2)
- 1)
TABLED 3.6.20-1 (Cont) OPERATIONAL RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Number of Samples(al and Locations Sampling and Collection Frequency (al 1 sample each of two commercially or Twice per year recreationally important species in the vicinity of a plant discharge area. (hJ 1 sample each of the same species from an area at least 5 miles distant from the site.<ctJ Samples of three different kinds of broad leaf Once per year during harvest vegetation (such as vegetables) grown nearest to season each of two different off-site locations of highest calculated site average D/Q (based on all licensed site reactors).
- 2)
One sample of each of the similar broad leaf vegetation grown at least 9.3-20 miles distant in a least prevalent wind direction. I 3.1-36 Type of Analysis and Frequency Gamma isotopic analysis<c> on edible portions twice per year Gamma isotopic(cJ analysis of edible portions (isotopic to include 1-131 or a separate 1-131 analysis may be performed) once during the harvest season CY-NM-170-301 Revision 36 May2017
NOTES FOR TABLE D 3.6.20-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 (a) It is recognized that, at times, it may not be possible or practical to obtain samples of the media of choice at the most desired location or time. In these instances, suitable alternative media and locations may be chosen for the particular pathway in question and may be substituted. Actual locations (distance and directions) from the site shall be provided in the Annual Radiological Environmental Operating Report. Highest 0/Q locations are based on historical meteorological data for all site licensed reactors. (b) Particulate sample filters should be analyzed for gross beta 24 hours or more after sampling to allow for radon and thoron daughter decay. If the gross beta activity in air is greater than 10 times a historical yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples. (c) Gamma isotopic analysis means the identification and quantification of gamma emitting radionuclides that may be attributable to the effluents from the facility. (d) The purpose of these samples is to obtain background information. If it is not practical to establish control locations in accordance with the distance and wind direction criteria, other sites, such as historical control locations which provide valid background data may be substituted. (e) One or more instruments, such as a pressurized ion chamber, for rneasuring and recording dose rate continuously may be used in place of, or in addition to, integrating dosimeters. For the purpose of this table, a thermoluminescent dosimeter may be considered to be one phosphor and two or more phosphors in a packet may be considered as two or more dosimeters. Film badges shall not be used for measuring direct radiation. (f) The "upstream sample" should be taken at a distance beyond significant influence of the discharge. The "downstream sample" should be taken in an area beyond but near the mixing zone, if possible. (g) Composite samples should be collected with equipment (or equivalent) which is capable of collecting an aliquot at time intervals which are very short (e.g. hourly) relative to the compositing period (e.g. monthly) in order to assure obtaining a representative sample. (h) In the event commercial or recreational important species are not available as a result of three attempts, then other species may be utilized as available. I 3.1-37 CY-NM-170-301 Revision 36 May2017
TABLED 4.6.20-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 DETECTION CAPABILITIES FOR ENVIRONMENTAL SAMPLE ANALYS1s<a,bJ LOWER LIMIT OF DETECTION LLD!cl Surveillance Requirement WaterlcJ Airborne Particulate or Fish Milk Analysis (pCi/1) Gases (pCi/m 3 ) (pCi/kg, wet) (pCi/1) gross beta 4 0.01 H-3 2000* Mn-54 15 130 Fe-59 30 260 Co-58, Co-60 15 130 Zn-65 30 260 Zr-95, Nb-95 15 1-131 1*
- 0.07 1
Cs-134 15 0.05 130 15 Cs-137 18 0.06 150 18 Ba/La-140 15 15 If no drinking water pathway exists, a value of 3000 pCi/liter may be used. If no drinking water pathway exists, a value of 15 pCi/liter may be used. I 3.1-38 Food Products (pCi/kg, wet) 60
- 60.
80 Sediment (pCi/kg, dry) 150 180 CY-NM-170-301 Revision 36 May 2017
NOTES FOR TABLED 4.6.20-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 (a) This list does not mean thafonly these nuclides are to be considered. Other peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating Report pursuant to Technical Specification 6.6.2, "Annual Radiological Environmental Operating Report", and Control D 6.9.1.d. (b) Required detection capabilities for thermoluminescent dosimeters used for environmental measurements are given in ANSI N.545 (1975), Section 4.3. Allowable exceptions to ANSI N.545 (1975), Section 4.3 are contained in Part II, Section 4.3. (c) The LLD is defined, for purposes of these specifications, as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will be detected with 95 percent probability with only 5 percent probability of falsely concluding that a blank observation represents a "real" signal.
- For a particular measurement system, which may include radiochemical separation:
LLD= 4.66 Sb E*V*2.22*Y*exp (-1cl\\t) Where: LLD is the "a priori" lower limit of detection as defined above, as picocuries per unit mass or volume, Sb is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate, as counts per minute, E is the counting efficiency, as counts per disintegration, V is the sample size in units of mass or volume, 2.22 is the number of disintegrations per minute per picocurie, Y is the fractional radiochemical yield, where applicable, A is the radioactive decay constant for the particular radionuclide, and ~t for environmental samples is the elapsed time between sample collection, or end of the sample collection period an~ time of counting. Typical values of E, V, Y and 8t should be used in the calculation. 13.1-39 CY-NM-170-301 Revision 36 May2017
NOTES FOR TABLED 4.6.20-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM D 3/4.6.20 It should be recognized that the LLD is defined as a before the fact limit representing the capability of a measurement system and not as an after the fact limit for the particular measurement. Analyses shall be performed in such a manner that the stated LLDs will be achieved under routine conditions. Occasionally, background fluctuations, unavoidable small sample sizes, the presence of interfering nuclides or other uncontrollable circumstances may render these LLDs unachievable. In such cases, the contributing factors shall be ideritified and described in the Annual Radiological Environmental Operating Report pursuant to Technical Specification 6.6.2, "Annual Radiological Environmental Operating Report", and Control D 6.9.1.d. I 3.1-40 CY-NM-170-301 Revision 36 May 2017
CONTROLS DLCO 3.6.21 INTERLABORATORY COMPARISON PROGRAM Applicability: Applies to participation in an interlaboratory comparison program on environmental sample analysis. Objective: To ensure the accuracy of measurements of radioactive material in environmental samples. Specification: Analyses shall be performed on radioactive materials supplied as part of an lnterlaboratory Comparison Program which has been approved by the Commission. Participation in this program shall include media for which environmental samples are routinely collected and for which intercomparison samples are available. With analyses not being performed as required above, report the corrective actions taken to prevent a recurrence to the Commission in the Annual Radiological Environmental Operating Report. I 3.1-41 DSR 4.6.21 INTERLABORATORY COMPARISON PROGRAM D 3/4.6.21 SURVEILLANCE REQUIREMENT INTERLABORATORY COMPARISON PROGRAM Applicability: Applies to testing the validity of measurements on environmental samples. Objective: To verify the accuracy of measurements on radioactive material in environmental samples. Specification: The lnterlaboratory Comparison Program shall be described in Part II. A summary of the results obtained as part of the above required lnterlaboratory Comparison Program shall be included in the Annual Radiological Environmental Operating Report. Participants in the EPA Cross Check Program may provide the EPA program code designation in lieu of providing results. CY-NM-170-301 Revision 36 May2017
CONTROLS DLCO 3.6.22 LAND USE CENSUS Applicability: Applies to the performance of a land use census in the vicinity of the Nine Mile Point Nuclear Facility. Objective: To determine the utilization of land within a distance of three miles from the.Facility. Specification: A land use census shall be conducted and shall identify within a distance of three miles the location in each of the 16 meteorological sectors the nearest residence and within a distance of three miles the location in each of the 16 meteorological sectors of.ill! milk animals. In lieu of a garden census, specifications for vegetation sampling in Table* o 3.6.20-1 shall be followed, including analysis of appropriate controls. With a land use census identifying a milk animal location(s) that represents a calculated D/Q value greater than the D/Q value currently being used in Control DSR 4.6.15.b.(3), identify the new location(s) in the next Radioactive Efflu~nt Release Report. I 3.1-42 LAND USE CENSUS D 3/4.6.22 SURVEILLANCE REQUIREMENT DSR 4.6.22 LAND. USE CENSUS Applicability: Applies to assuring that current land use is known. Objective: To verify the appropriateness of the environmental surveillance program. Specification: The land use census shall be conducted during the growing season at least once per 12 months using that information that will provide the best results, such as conducting a door-to-door survey, aerial survey or consulting local agriculture authorities. The results of the land use census shall be included in the Annual Radiological Environmental Operating. Report. CY-NM-170-301 Revision 36 May 2017
CONTROLS If the D/Q value at a new milk sampling location is significantly greater (50%) than the D/Q value at an existing milk sampling location, add the new location to the radiological environmental monitoring program within 30 days. The sampling location(s) excluding the control station location, having the lowest calculated D/Q may be deleted from this monitoring program after October 31 of the year in which this land use census was conducted. Pursuant to Control D 6.9.1.e identify the new location(s) in the next Radioactive Effluent Release Report and also include in the report a revised figure(s) and table for Part II reflecting the new location(s). I 3.1-43 LAND USE CENSUS D 3/4.6.22 SURVEILLANCE REQUIREMENT CY-NM-170-301 Revision 36 May2017
I l PART I-RADIOLOGICAL EFFLUENT CONTROLS Bases I B 3.1-0 CY-NM-170-301 Revision 36 May2017
RADIOACTIVE EFFLUENT INSTRUMENTATION, RADIOACTIVE EFFLUENTS' - LIQUID CONCENTRATION B 3/4.6.14 BASES FOR DLCO 3.6.14 and DSR 4.6.14 RADIOACTIVE EFFLUENT INSTRUMENTATION The radioactive liquid and gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in liquid and gaseous effluents during actual or potential releases of liquid and gaseous effluents. The alarm/trip setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in Part II to ensure that the alarm/trip will occur prior to exceeding the limits as described in Technical Specification 6.5.3, "Radioactive Effluent Controls Program". The alarm/trip setpoint for the Offgas process monitor is limited by Technical Specification 3.6.15. The Objective of that Specification is to assure radioactive material released is within the limits of 1 OCFR20 and 1 OCFR50 Appendix I. By doing so, total body exposure to an individual at the exclusion area boundary will not exceed a very small fraction of the limits of 10 CFR 100 in the event this effluent is discharged directly without treatment. The Stack Effluent Monitors provide Effluent Monitoring (which requires a minimum of 1 Low Range and 1 High Range monitor) and Containment Purge and Vent Isolation (which requires 2 High Range monitors). When the Purge and Vent isolation capability is not required (Primary containment not required OR Purge and Vent valves shut and clearance applied), only 1 High Range Monitor and 1 Low Range monitor are required to satisfy the monitoring function. The functionality and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63 and 64 of Appendix A to 1 OCFR Part 50. The purpose of tank level indicating devices is to assure the detection and control of leaks that if not controlled could potentially result in the transport of radioactive materials to unrestricted areas. IB 3.l-l CY-NM-170-301 Revision 36 May2017
BASES FOR DLCO 3.6.15 AND DSR 4.6.15 RADIOACTIVE EFFLUENTS Liquid Concentration RADIOACTIVE EFFLUENT INSTRUMENTATION, RADIOACTIVE EFFLUENTS-LIQUID CONCENTRATION B 3/4.6.15 This control is provided to ensure that the concentration of radioactive materials released in liquid waste effluents to unrestricted areas will be less than ten times the concentration levels specified in 10CFR Part 20, Appendix B, Table 2, Column 2. This limitation provides additional assurance that the levels of radioactive materials in bodies of water in unrestricted areas will result in exposures within ( 1) the Section I I.A design objectives of Appendix I, 1 OCFR Part 50, to a member of the public and (2) the limits of 10 CFR 20.1301 (e) to the population. The concentration limit for dissolved or entrained noble gases is based upon the assumption that Xe-135 is the controlling radioisotope and its effluent concentration in air (submersion) was converted to an equivalent concentration in water using the methods described in International Commission on Radiological Protection (ICRP) Publication 2. The required detection capabilities for radioactive materials in liquid waste samples are tabulated in terms of the lower limits of detection (LLDs ). Detailed discussion of the LLD and other detection limits can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, L. A., "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry," Anal. Chem. 40. 586-93 (1968), and Hartwell, J. K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975). Because tritium was identified in the Reactor Building Perimeter Drains, (2012), a non-radioactive system which discharges to the storm drains, the discharge from the Reactor Building Perimeter Drains will be sampled while the sump pumps are running and a composite sample analyzed for radioactivity. The source of the radioactivity has been determined to be discharges from the Emergency Condenser Vents during surveillance testing and actual events. The radioactivity released, dose rates and doses have been, and will continue to be, determined for each release using existing Chemistry Surveillance Procedures and reported in the Radioactive Effluent Release Report (RERR). Because the radioactivity detected in the perimeter drain has already been accounted for in the liquid releases, discharges from the drains will be reported in the RERR as a separate item. Monitoring this pathway is to validate that the radioactivity released via this pathway is equal to or less than the quantity accounted for as released via the Emergency Condenser Vents. IB3.l-2 CY-NM-170-301 Revision 36 May 2017
BASES FOR DLCO 3.6.15 AND DSR 4.6.15 RADIOACTIVE EFFLUENTS Liquid Dose RADIOACTIVE EFFLUENTS - LIQUID DOSE B 3/4.6.15 This control is provided to implement the requirements of Section II.A, Ill.A and IV.A of Appendix I, 10CFR.,Part 50. The controls expressed as quarter and annual limits are set at those values found in Section II.A. of Appendix I, in accordance with Section IV.A. The action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents to unrestricted areas will be kept "as low as is reasonably achievable." There are no drinking water supplies that can be potentially affected by plant operations. The dose calculation methodology and parameters in Part II implement the requirements in Section Ill.A of Appendix I that conformance with the guides of Appendix I be shown by calculation procedures based on models and data, such that the actual exposure of a member of the public through appropriate pathways is unlikely to be substantially underestimated. The equations specified in Part II for calculating the doses due to the actual release rates of radioactive materials in liquid effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 1 OCFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.113, "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," April 1977. IB3.l-3 CY-NM-170-301 Revision 36 May 2017
Gaseous Dose Rate RADIOACTIVE EFFLUENTS - GASEOUS DOSE RATE B 3/4.6.15 BASES FOR DLCO 3.6.15 ANO DSR 4.6.15 RADIOACTIVE EFFLUENTS This control is provided to ensure that the dose at any time at or beyond the site boundary from gaseous effluents from all units on the site will be within the annual dose limits of 1 OCFR Part 20 to unrestricted areas. The annual dose limits are the doses associated with the concentrations of 1 OCFR Part 20, Appendix B, Table 2, Column 1. These limits provide reasonable assurance that radioactive material discharged in gaseous
- effluents will not result in the exposure of a member of the public in an unrestricted area, either within or outside the site boundary, to annual average concentrations exceeding the limits specified in Appendix B, Table 2 of 1 OCFR Part 20 or as governed by 10 CFR 20.1302(c). For members of the public who may at times be within the site boundary, the occupancy of that member of the public will usually be sufficiently low to compensate for any increase in the atmospheric diffusion factor above that for the site boundary. The specified release rate limits restrict, at all times, the corresponding gamma and beta dose rates above l::>ackground to a member of the public at or beyond the site boundary to less than or equal to 500 mrems/year to the total body or to less than or equal to 3000 mrems/year to the skin. These release rate limits also restrict, at all times, the corresponding thyroid dose rate above background to a child via the inhalation pathway to less than or equal to 1500 mrems/year.
The required detection capabilities for radioactive materials in gaseous waste samples are tabulated in terms of the lower limits of detection (LLOs). Detailed discussion of the LLD and other detection limits can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, L.A., "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry," Anal. Chem. 40, 586-93 (1968), and Hartwell, J. K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975). I B 3.1-4 CY-NM-170-301 Revision 36 May 2017
Dose - Noble Gases RADIOACTIVE EFFLUENTS - DOSE - NOBLE GASES B 3/4.6.15 BASES FOR DLCO 3.6.15 AND DSR 4.6.15 RADIOACTIVE EFFLUENTS This control is provided to implement the requirements of Sections 11.B, Ill.A and IV.A of Appendix I, 10CFR Part 50. The controls expressed as quarter and annual limits are set at those values found in Section 11.B of Appendix I in accordance with the guidance of Section IV.A. The action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV-A of Appendix I to assure that the releases of radioactive material in gaseous effluents to unrestricted areas will be kept "as low as is reasonably achievable." The Surveillance Requirement implements the requirements in Section Ill.A of Appendix I that conform with the guides of Appendix I be shown by calculational procedures based on models and data such that the actual exposure of a member of the public through appropriate pathways is unlikely to be substantially underestimated. The dose calculation methodology and parameters established in Part II for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR Part 50, Appendix I, "Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water Cooled Reactors," Revision 1, July 1977. The Offsite Dose Calculation Manual Part II equations provided to determine the air doses beyond the site boundary are based upon the historical average atmospheric conditions. I B 3.1-5 CY-NM-170-301 Revision 36 May2017
RADIOACTIVE EFFLUENTS - DOSE - IODINE -131, IODINE -133, TRITIUM AND RADIONUCLIDES IN PARTICULATE FORM B 3/4.6.15 BASES FOR DLCO 3.6.15 AND DSR 4.6.15 RADIOACTIVE EFFLUENTS Dose - Iodine-131, Iodine-133, Tritium and Radionuclides in Particulate Form This control is provided to implement the requirements of Sections 11.C, Ill.A and IV.A of Appendix I, 10CFR Part 50. The controls expressed as quarter and annual limits are set at those values found in Section 11.C of Appendix I in accordance with the guidance of Section IV.A. The action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive materials in gaseous effluents to unrestricted areas will be kept "as low as is reasonably achievable." The Part II calculational methods specified in the Surveillance Requirement implements the requirements in Section Ill.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a member of the public through appropriate pathways is unlikely to be substantially underestimated. The Part II calculational methodology and parameters for calculating the doses due to the actual release rates of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors," Revision 1, July 1977. These equations also provide for determining the actual doses based upon the historical average atmospheric conditions. The release rate specifications for iodine-131, iodine-133, tritium and radionuclides in particulate form with half lives greater than 8 days are dependent upon the existing radionuclide pathways to man, in the areas beyond the site boundary. The pathways that were examined in the development of these calculations were: 1) individual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man and 4) deposition on the ground with subsequent exposure of man. I B 3.1-6 CY-NM-170-301 Revision 36 May 2017
RADIOACTIVE EFFLUENTS-TOTAL DOSE-URANIUM FUEL CYCLE B 3/4.6.15 BASES FOR DLCO 3.6.15 AND DSR 4.6.15 RADIOACTIVE EFFLUENTS Total Dose - Uranium Fuel Cycle This control is provided to meet the dose limitations of 40CFR Part 190 that have been incorporated into 1 OCFR Part 20 by 46FR 18525. The control requires the preparation and submittal of a Special Report whenever the calculated doses from plant generated radioactive effluents and direct radiation exceed 25 mrems to the whole body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems. For sites containing up to 4 reactors, it is highly unlikely that the resultant dose to a member of the public will exceed the dose limits of 40CFR Part 190 if the individual reactors remain within twice the dose design objectives of Appendix I and if direct radiation doses from the reactor units, the on-site Independent Spent Fuel Storage Installation (ISFSI), and outside storage tanks are kept small. The Special Report will describe a course of action that should result in the limitation of the annual dose to a member of the public to within the 40CFR Part 190 limits. For the purposes of the Special Report, it may be assumed that the dose commitment to a member of the public from other uranium fuel cycle sources is negligible, with the exception that dose contribution from other nuclear fuel cycle facilities at the same site or within a radius of 8 km must be considered. If the dose to any member of the public is estimated to exceed the requirements of 40CFR Part 190, the Special Report with a request for variance (provided the release conditions resulting in violation of 40CFR Part 190 have not already been corrected), in accordance with the provisions of 40CFR Part 190.11 and 1 O CFR Part 20.2203(a)(4) is considered to be a timely request and fulfills the requirements of 40CFR Part 190 until NRC staff action is completed. The variance only relates to the limits of 40CFR Part 190 and does not apply in any way to the other requirements for dose limitation of 10CFR Part 20, as addressed in Controls DLCO 3.6.15.a.(1) and DLCO 3.6.15.b.(1 ). An individual is not considered a member of the public during any period in which he/she is engaged in carrying out any operation that is part of the nuclear fuel cycle. IB3.l-7 CY-NM-170-301 Revision 36 May 2017
RADIOACTIVE EFFLUENT TREATMENT SYSTEMS - LIQUID AND GASEOUS B 3/4.6.16 BASES FOR DLCO 3.6.16 AND DSR 4.6.16 RADIOACTIVE EFFLUENT TREATMENT SYSTEMS Liquid Radwaste Treatment System The requirement that the appropriate portions of this system be used provides assurance that the releases of radioactive inaterials in liquid effluents will be kept "as low as is reasonably achievable." This control implements the requirements of 1 O CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR 50 and the design objective given in Section 11.D of Appendix I to 10 CFR Part 50. Projected doses are calculated on a batch rather than every 31 days due to the low frequency of releases. Gaseous Effluent Treatment Systems The functionality of the Gaseous Radwaste Treatment System and the-Vemilation Exhaust Treatment System ensures that the systems will be available for use whenever gaseous effluents require treatment prior to release to the environment. The requirement that appropriate portions of these systems be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable." This control implements the requirements of 1 O CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR 50 and the design objectives given in Section 11.D of Appendix I to 10 CFR Part 50. The control governing the use of appropriate portions of the Gaseous Radwaste Treatment System is based on time without treatment rather than dose, due to the wide variability in effluent with changing power conditions. Since the capability exists to operate within specification without use of the Gaseous Radwaste Treatment System, it is conceivable that due to unforeseen circumstances, limited operation without the system may be made sometime during the life of the plant. The control governing the use of appropriate portions of the Ventilation Exhaust Treatment System was specified as a suitable fraction of the dose design objectives set forth in 11.C of Appendix I, 10CFR Part 50, for gaseous effluents. I B 3.1-8 CY-NM-170-301 Revision 36 May 2017
MARK I CONTAINMENT, LIQUID HOLDUP TANKS B 3/4.6.18, B 3/4.6.19 BASES FOR DLCO 3.6.18 AND DSR 4.6.18 MARK I CONTAINMENT This control provides reasonable assurance that releases from drywell purging operations will not exceed the annual dose limits of 1 OCFR Part 20 for unrestricted areas: BASES FOR DLCO 3.6.19 AND-DSR4.6.19 LIQUID HOLDUP TANKS This control applies to any outdoor tank that is not surrounded by liners, dikes or walls capable of holding the tank contents and that does not have tank overflows and surrounding areas drains connected to the liquid radwaste treatment system. Restricting the quantity of radioactive material contained in the specified tanks provides assurance that in the event of an uncontrolled release of the tanks' contents, the resulting concentrations would be less than ten times the concentrations of 1 OCFR Part 20, Appendix B, Table 2, Column 2, at the nearest potable water supply and the nearest surface water supply in an unrestricted area. I B 3.1-9 CY-NM-170-301 Revision 36 May 2017
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM B 3/4.6.20 BASES FOR DLCO 3.6.20 AND DSR 4.6.20 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM The radiological environmental monitoring program required by this control provides representative measurements of ra9iation and of radioactive materials in those exposure pathways and for those radionuclides that lead to the highest potential radiation exposures of members of the public resulting from the station operation. This monitoring program implements Section IV.8.2 of Appendix I to 10CFR Part 50 and thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways. Guidance for this monitoring program is provided by the Radiological Assessment Branch Technical Position on Environmental Monitoring. The initially specified monitoring program will be effective for at least the first three years of commercial operation. Following this period, program changes may be initiated based on operational experience.
- The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs). The LLDs requked by Table D 4.6.20-1 are considered optimum for routine environmental measurements in industrial laboratories. It should be recognized
- that the LLD is defined as a before the fact limit representing the capability of a measurement system and not as an after the fact limit for a particular measurement.
Detailed discussion of the LLD, and other detection limits, can be found in HASL Procedures Manuaf, HASL-300 (revised annually), Currie, L.A., "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry," Anal. Chem 40, 586-93 (1968) and Hartwell, J.K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975). I B 3.1-10 CY-NM-170-301 Revision 36 May 2017
INTERLABORATORY COMPARISON PROGRAM B 3/4.6.21 BASES FOR DLCO 3.6.21 AND DSR 4.6.21 INTERLABORATORY COMPARISON PROGRAM The requirement for participation in an approved lnterlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring for the purposes of Section IV.8.2 of Appendix I to 1 OCFR Part 50. IB3.l-1I CY-NM-170-301 Revision 36 May 2017
BASES FOR DLCO 3.6.22 AND DSR 4.6.22 LAND USE CENSUS LAND USE CENSUS 8 3/4.6.22 This control is provided to ensure that changes in the use of areas at and beyond the site boundary are identified and that modifications to the radiological environmental monitoring program are made if required by the results of this census. The best survey information such as from a door- . to-door survey(s}, from an aerial survey or from consulting with local agricultural authorities shall be used. This census satisfies the requirements of Section IV.8.3 of Appendix I to 1 OCFR Part 50. In lieu of a garden census, the significance of the exposure via the garden pathway can be evaluated by the sampling of vegetation as specified in Table D 3.6.20-1. A milk sampling location, as defined in Section 1, requires that at least 10 milking cows are present at a designated milk sample location. It has been found from past experience, and as a result of conferring with local farmers, that a minimum of 1 O milking cows is necessary to guarantee an adequate supply of milk twice per month for analytical purposes. Locations with less than 1 O milking cows are usually utilized for breeding purposes which eliminates a stable supply of milk for samples as a result of suckling calves and periods when the adult animals are dry. I B 3.1-12 CY-NM-170-301
- Revision 36 May 2017
PART I-RADIOLOGICAL EFFLUENT CONTROLS Section 6.0 Administrative Controls I 6.0-0 CY-NM-170-301 Revision 36 May 2017
6.0 ADMINISTRATIVE CONTROLS Administrative Controls 6.0 The ODCM Specifications are subject to Technical Specification Section 6.6.2, "Annual Radiological Environmental Operating Report," Section 6.6.3, "Radioactive Effluent Release Report," Section 6.5.1, "Offsite Dose Calculation Manual (ODCM);" and Section 6.5.3, "Radioactive Effluent Contr6ls Program." 1 i 6.0-1 CY-NM-170-301 Revision 36 May 2017
D 6.9 Reporting Requirements REPORTING REQUIREMENTS D6.9.1.d D.6.9.1.e D 6.9.1.d Annual Radiological Environmental Operating Report The Annual Radiological Environmental Operating Report shall include a comparison with operational controls as appropriate, and with environmental surveillance reports from the previous 5 years, and an assessment of the observed impacts of the plant operation on the environment. The report shall also include the results of lanctuse censuses required by Control DLCO 3.6.22. The report shall also include the following: a summary description of the radiological environmental monitoring program; at least two legible maps** covering all sampling locations keyed to a table giving distances and directions from the centerline of one reactor; the results of licensee participation in the lnterlaboratory Comparison Program, required by Control DLCO 3.6.21; discussion of all deviations from the sampling schedule of Table D 3.6.20-1; and discussion of all analyses in which the LLD required in Table D 4.6.20-1 was not achievable.
- One map shall cover stations near the site boundary; a second shall include the more distant stations.
D 6.9.1.e Radioactive Effluent Release Report The Radioactive Effluent Release Report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste releases from the unit as outlined in Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants", Revision 1, June 1974, with data summarized on a quarterly basis following the format of Appendix B thereof. The Radioactive Effluent Release Report shall include an annual summary of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability, and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability.* This same report shall include an assessment of the radiation doses from radioactive liquid and gaseous effluents to members of the public due to their activities inside the site boundary (Part II Figure 5.1.3-1) during the reporting period. All assumptions used in making these assessments, i.e., specific activity, exposure time and location, shall be included in these reports. The assessment of radiation doses shall be performed in aceor-dance with the methodology and parameters-in Part 11. The Radioactive Effluent Release Report shall also include an assessment of radiation doses to the likely most exposed member of the public from reactor releases and other nearby uranium fuel cycle sources, including doses from primary effluent pathways and direct radiation, for the previous calendar year to show conformance with 40 CFR Part 190, Environmental Radiation Protection Standards for Nuclear Power Operation. Acceptable methods for calculating the doses from liquid and gaseous effluents are given in Part II. In lieu of submission with the Radioactive Effluent Release Report, the licensee has the option of retaining this summary of required meteorological data on site in a file that shall be provided to the NRG upon request. I 6.0-2 CY-NM-170-301 Revision 36 May 2017 -~I
REPORTING REQUIREMENTS D 6.9.1.e The Radioactive Effluent Release Reports shall include a list of unplanned releases from the site to unrestricted areas of radioactive materials in gaseous and liquid effluents made during the reporting period. The Radioactive Effluent Release Reports shall include the following information for each class of solid waste (as defined by 1 O CFR Part 61) shipped offsite during the report period.
- a.
Container volume,
- b.
Total curie quantity (specify whether determined by measurement or estimate),
- c.
Principal radionuclides (specify whether determined by measurement or estimate),
- d.
Source of waste and processing employed (e.g., dewatered spent resin, compacted dry waste, evaporator bottoms),
- e.
Type of container (e.g., LSA, Type A, Type 8, Large Quantity), and,
- f.
Solidification agent or absorbent (e.g., cement) The Radioactive Effluent Release Reports shall include any changes made during the reporting period to the Process Control Program (PCP) and to the Offsite Dose Calculation Manual (ODCM), as well as a listing of new locations for dose calculations and/or environmental monitoring identified by the land use census pursuant to *Control DLCO 3.6.22. Changes to the Process Control Program (PCP) shall be reported to the Commission in the Radioactive Effluent Release Report for the period in which the change(s) was made. This submittal shall contain:
- a.
Sufficiently detailed information to totally support the rationale for the change without benefit of additional or _s~pplemental information;
- b.
A determination that the change did not reduce the overall conformance of the solidified waste product to existing criteria for solid wastes; and
- c.
Documentation of the fact that the change has been reviewed and found acceptable. Changes to the Offsite Dose Calculation Manual (ODCM) shall be in accordance with Technical Specification 6.5.1, "Offsite Dose Calculation Manual (ODCM)". I 6.0-3 CY-NM-170-301 Revision 36 May 2017
SPECIAL REPORTS D 6.9.3 D 6.9.3Special Reports Special reports shall be submitted in accordance with 10 CFR 50.4 to the Regional Office within the time period specified for each report. These reports shall be submitted covering the activities identified below pursuant to the requirements of the applicable reference specification:
- a. ~
- b.
C.
- d.
- e.
- f.
Not applicable to RETS
- g. ~--------------
- h.
Calculate Dose from Liquid Effluent in Excess of Limits, Control DLCO 3.6.15.a(2) (30 days from the end of the affected calendar quarter).
- i.
Calculate Air Dose from Noble Gases Effluent in Excess of Limits, Control DLCO 3.6.15.b(2) (30 days from the end of the affected calendar quarter).
- j.
Calculate Dose from 1-131, H-3 and Radioactive Particulates with half lives greater than eight days in Excess of Limits, Control DLCO 3.6.15.b(3)(b) (30 days from the end ofthe affected calendar quarter).
- k.
Caculated Doses from Uranium Fuel Cycle Source in Excess of Limits, Control DLCO 3.6.15.d (30 days from the end of the affected calendar year). I. Nonfunctional Gaseous Radwaste Treatment System, Control DLCO 3.6.16.b (30 days from the end of the affected calendar year).
- m.
Environmental Radiological Reports. With the level of radioactivity (as the result of plant effluents) in an environmental sampling media
- exceeding the reporting level of Table D 6.9.3-1, when averaged over any calendar quarter, in lieu of a Licensee Event Report, prepare and submit to the Commission within thirty (30) days from the end of the calendar quarter a special report identifying the cause(s) for exceeding the limits, and define the corrective action to be taken.
I 6.0-4 CY-NM-170-301 Revision 36 May 2017
Table D 6.9.3-1 REPORTING LEVEL FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES REPORTING LEVELS Water Airborne Particulate or Fish Milk Food Products Analysis (pCi/1) Gases (pCi/m 3 ) --(pCi/kg, wet) (pCi/1) (pCi/kg, wet) H-3 20,000* Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-95, Nb-95 400 1-131 2 *
- 0.9 3
100 Cs-134 30 10.0 1,000 60 1,000 Cs-137 50 20.0 2,000 70 2,000 Ba/La-140 200 300 SPECIAL REPORTS D 6.9.3 For drinking water samples. This is a 40 CFR 141 value. If no drinking water pathway exists, a value of 30,000 pCi/liter may be used. If no drinking water pathway exists, a value of 20 pCi/lileuilay be used. I 6.0-5 CY-NM-170-301 Revision 36 May 2017
PART II-CALCULATION METHODOLOGIES II 1 CY-NM-170-301 Revision 36 May 2017
1.0 LIQUID EFFLUENTS 1.1 Setpoint Determinations 1.1.1 Basis Monitor setpoints will be established such that the concentration of radionuclides in the liquid effluent releases in the discharge canal shall be limited to ten times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-04 µCi/ml total activity. Setpoints for the Service Water System Effluent Line will be calculated quarterly based on the radionuclides identified during the previous year's releases from the liquid radwaste system or the isotopes identified in the most recent rad waste release or other identified probable source. Setpoints for the Liquid Radwaste Effluent Line will be based on the radionuclides identified in each batch of liquid waste prior to its release. After release, the Liquid Radwaste monitor setpoint may remain as set, or revert back to a setpoint based on a previous Radioactive Effluent Release Report, or install blank flange in the discharge line and declare nonfunctional in accordance with the ODCM Part I. Since the Service Water System effluent monitor and Liquid Radwaste effluent monitor can only detect gamma radiation, the alarm setpoints are calculated by using the concentration of gamma emitting isotopes only ( or the corresponding Maximum Effluent Concentration (MEC) values for the same isotopes, whichever are higher) in the L i(µCi/ml)iy expression (Section 1.1.2, 1.1.3). The Required Dilution Factor (RDF) is calculated using concentrations of all isotopes present ( or the corresponding MEC values for the same isotopesJ whichever are higher) jncluding tritium and other non-gamma emitters to ensure that all radionu lides in the discharge canal do not exceed Technical Specifications Radioactive Effluent C ntrols Program limits. 1.1.2 Service Water System Effluent Line Alarm Setpoint The detailed methods for establishing setpoints for the Service Water System Effluent Line Monitor shall be contained in the Nine Mile Point Station Procedures. These methods shall be in accordance with the following: The General Setpoint Equation is Setpoint < (Conservative Factor) (Concentration)(ADF)(CF) RDF From the above General Setpoint Equation the Hi and Alert alarms are calculated as follows: L. (µCi I ml). /CF)TEDF IF Setpomt (Hi alarm)< 0.9 '
- r 1' sw + background Li [(µCi I mlJ;r I MEC;]
S (Al 1 ) Li (µCi I ml)ir (CF) TEDF I F sw b k d etpomt ert a arm < O. 7 + ac groun Li [(µCi I ml);r I MECi) (µCi/ml)ir= concentration of gamma emitting isotope i in the sample, or the corresponding MEC of gamma emitting isotope i (MEC)i, whichever is higher (units= µCi/ml). II 2 CY-NM-170-301 Revision 36 May 2017
1.1.2 Service Water System Effluent Line Alarm Setpoint (Cont'd) (µCi/ml)iT = concentration of any radioactive isotope i in the sample including tritium and other non-gamma emitters or corresponding MEC of isotope i, MECi, whichever is higher (units = µCi/ml). TF = Tempering Fraction TDF = Total Dilution Flow (units= gallons/minute). TEDF = Total Effective Dilution Flo~= TDF (1-TF) (units= gallons/minute) Fsw = Service Water Flow (units= gallons/minute). CF = Monitor calibration factor (units= net cpm/µCi/ml). MECi = Maximum Effluent Concentration, ten times the Effluent Concentration for radionuclide i as specified in 10 CFR 20, Appendix B, Table 2, Column 2 (units µCi/ml). Sample = Those nuclides present in the previous batch release from the liquid radwaste effluent system or those nuclides present in the last Radioactive Effluent Release Report (units= µCi/ml) or those nuclides present in the service water system.** (MEC)iy = same as MECi but for gamma emitting nuclides only. 0.9 and 0.7= factors of conservatism to account for inaccuracies. RDF Required Dilution Factor, rl i [(µCi/ml) iT/MECi]. IfMEC values are used in the (µCi/ml)iy, they must also be used in calculating RDF (numerator). RDF= FMEC (See Section II-1.2). ADF = Actual Dilution Factor, TEDF!Fsw
- For periods with known reactor water to Reactor Building Closed Loop Cooling (RBCLC) system leakage, RBCLC concentration may be prudently substituted for the above.
1.1.3 Liquid Radwaste Effluent Line Alarm Setpoint The detailed methods for establishing setpoints for the Liquid Radwaste Effluent Line Monitor shall be contained in the Nine Mile Point Station Procedures. These methods shall be in accordance with the following: The General Setpoint Equation in Section II-1.1.2 is used to develop the Hi-Hi and Hi alarm setpoints below: Li (µCi I ml)i (CF) TEDF I Fre Setpoint (Hi-Hi alarm) < 0.9 . Y + background . Li [(µCz I ml)iT I MECi J II 3 CY-NM-170-301 Revision 36 May 2017
1.1.3 Liquid Radwaste Effluent Line Alarm Setpoint (Cont'd) Li (µCi I ml)i (CF)TEDF I Fre Setpoint (Hi alarm) < 0. 7 Y + background Li [(µCi I ml)iT I MECi J (µCi/ml)i1 = concentration of gamma emitting isotope i in the sample or the corresponding MEC of gamma emitting isotope i, (MEC)i whichever is higher. (µCi/ml)iT - concentration of any radioactive isotope i in the sample including tritium and other non-gamma emitters or the corresponding MEC of isotope i, MECi, whichever is higher. (units= µCi/ml). TF TDF TEDF Pre CF MECi (MEC)iy 0.9 and 0.7 RDF = Tempering Fraction = Total Dilution Flow (units= gallons/minute). = Total Effective Dilution Flow= TDF (1-TF) (units = gallons/minute) Radwaste Effluent Flow (units= gallons/minute). Monitor calibration factor (units = net cps/µCi/ml). Maximum Effluent Concentration, ten times the Effluent Concentration for radionuclide i as specified in IO CPR 20, Appendix B, Table 2, Column 2, for those nuclides detected by spectral analysis of the contents of the rad waste tanks to be released. (units = µCi/ml) same as MECi bL for gamma emitting nuclide only. = factors of conservatism to account for inaccuracies. = Required Dilution Factor, L i [(µCi/ml) iT/MECi]. IfMEC values are used in the (µCi/ml)iy, they must also be used in calculating RDF (numerator). ADP Actual Dilution Factor= TEDF!Fre Notes: (a) IfTEDF!Fre = L i [(µCi/ml) iT/MECi](if ADP= RDF) the discharge could not be made, since the monitor would be continuously in alarm. To avoid this situation, Pre will be reduced (normally by a factor of 2) to allow setting the alarm point at a concentration higher than tank concentration. This will also result in a discharge canal concentration at approximately 50% Maximum Effluent Concentration. (b) TF is tempering fraction (i.e., diversion of some fraction of discharge flow to the intake canal for the purpose of temperature control). II 4 CY-NM-170-301 Revision 36 May 2017
1.1.4 1.1.4.1 1.1.4.2 1.1.4.3 Discussion Control of Liquid Effluent Batch Discharges At Nine Mile Point Unit 1 Liquid Radwaste Effluents are released only on a batch mode. To prevent the inadvertent release of any liquid radwaste effluents, radwaste discharge is mechanically isolated (blank flange installed or discharge valve chain-locked closed) following the completion of a batch release or series of batch releases. This mechanical isolation remains in place and will only be removed prior.to the next series of liquid radwaste discharges after all analyses required in station procedures and Table D 4.6.15-lA of Part I are performed and monitor setpoints have been properly adjusted. Simultaneous Discharges of Radioactive Liquids If during the discharge of any liquid rad waste batch, there is an indication that the service water canal has become contaminated (through a service water monitor alarm or through a grab sample analysis in the event that the service water monitor is nonfunctional) the discharge shall be terminated immediately. The liquid radwaste discharge shall not be continued until the cause of the service water alarm (or high grab sample analysis result) has been determined and the appropriate corrective measures taken to ensure ten times the effluent concentrations specified in 1 OCFR20, Appendix B, Table 2, Column 2 (Section D 3.6.15.a(l) of Part I) are not exceeded. In accordance with Liquid Waste procedures, controls are in place to preclude a simultaneous release of liquid rad waste batch tanks. In addition, an independent verification of the discharge valve line-up is performed prior to discharge to ensure that simultaneous discharges are prevented. Sampling Representativeness I This section covers Part I Table D 4.6.15-1 Note b concerning thoroughly mixing of each batch of liquid rad waste prior to sampling. Liquid Rad waste Tanks scheduled for discharge at Nine Mile Point Unit 1 are isolated (i.e. inlet valves marked up) and at least three tank volumes of entrained fluids are recirculated prior to sampling. Minimum recirculation time is calculated as follows: Minimum Recirculation Time= 3.0(T/R) Where: 3.0 = Plant established mixing factor, unitless T = Tank volume, gal R = Recirculation flow rate, gpm Additionally, the Hi Alarm setpoint of the Liquid Radwaste Effluent Radiation Monitor is set at a value corresponding to not more than 70% of its calculated response to the grab sample or corresponding MEC values. Thus, this radiation monitor will alarm if the grab sample, or corresponding MEC value, is significantly lower in activity than any part of the tank contents being discharged. II 5 CY-NM-170-301 Revision 36 May 2017
1.1.4.4 Liquid Radwaste System Operation Part I Section DLCO 3.6.16.a requires that the liquid rad waste system shall be used to reduce the radioactive materials in liquid wastes prior to their discharge, as necessary, to meet the concentration and dose requirements of Section DLCO 3.6.15. Utilization of the radwaste system will be based on the capability of the indicated components of each process system to process contents of the respective low conductivity and high conductivity collection tanks: 1). Low Conductivity (Equipment Drains): Radwaste Filter and Radwaste Demin. (See Fig. D-1) or modular waste water technology ("THERMEX")
- 2)
High Conductivity (Floor Drains): Waste Evaporator (See Fig. D-1) or modular waste water technology ("THERMEX") directly to the Waste Collector Tank or the Waste Sample Tanks. Cumulative dose contributions from liquid effluents for the current calendar quarter and the current calendar year shall be determined as described in Section II-1.3 of this manual prior to the release of each batch of liquid waste. This same dose projection of Section II-1.3 will also be performed in the event that untreated liquid waste is discharged, to ensure that the dose limits of Part I DLCO 3.6.15.a(2) are not exceeded. (Thereby implementing the requirements of 10CFR50.36a, General Design Criteria 60 of Appendix A and the Design Objective given in Section II-D of Appendix I to 10 CFR50). For the purpose of dose projection, the following assumptions shall be made with regard to concentrations of non-gamma emitting radionuclides subsequently analyzed: a) I [H-3]
- H-3 Concentration found recent condensate stlrage tank analysis b)
[Sr-89] c) [Sr-90] d) [Fe-55]
- 4 x Cs-137 Concentration
- 0.5 x Cs-137 Concentration
- 1 x Co-60 Concentration Assumed Scaling Factors used in b, c, and d above represent conservative estimates derived from analysis of historical data from process waste streams. Following receipt ofH-3, Sr-89, Sr-90 and Fe-55 analysis information, dose estimates shall be revised using actual radionuclide concentrations and actual tank volumes discharged.
II 6 CY-NM-170-301 Revision 36 May 2017
1.1.4.5 1.2 Service Water System Contamination Service water is normally non-radioactive. If contamination is suspected, as indicated by a significant increase in service water effluent monitor response, grab samples will be obtained from the service water discharge lines and a gamma isotopic analysis meeting the LLD requirements of Part I Table D 4.6.15-1 completed. If it is determined that an inadvertent radioactive discharge is occurring from the service water system, then: a) A 10CFR 50.59 review shall be performed (ref. l&E Bulletin 80-10), b) daily service water effluent samples shall be taken and analyzed for principal gamma emitters until the release is terminated, c) an incident composite shall be prepared for H-3, gross alpha, Sr-89, Sr-90 and Fe-55 analyses and, d) dose projections shall be performed in accordance with Section 11-1.3 of this manual (using estimated concentrations for H-3, Sr-89, Sr-90 and Fe-55 to be conservatively determined by supervision at the time of the incident). Additionally, service water effluent monitor setpoints may be recalculated using the actual distribution of isotopes found from sample analysis. When contamination is indicated by quantitative non-gamma emitter results, sample and analyze gamma and non-gamma emitters weekly. Reactor Building Perimeter Drain Discharges I The Reactor Building Perimeter Drain became contamtnated to detectable levels with tritium, due to discharges from the Emergency Condenser (EC) Vents. This pathway has been evaluated by extensive sampling and analysis. It has been determined that any discharge to the environment via this pathway will be well within regulatory limits. Discharges via this pathway will be monitored by composite sampling and laboratory analysis. The discharges will be tracked and reported annually in the Radioactive Effluent Release Report (RERR). Because the radioactive discharge from the EC Vents are evaluated each time the ECs are actuated and the results reported in the ~RR, the activity detected in the perimeter drain discharge will be reported separately from other liquid discharges. Liquid Effluent Concentration Calculation This calculation documents compliance with Part I Section DLCO 3.6.15,a (1). The concentration of radioactive material released in liquid effluents to unrestricted areas (see Figure 5.1.3-1) shall be limited to ten times the effluent concentrations specified in 1 OCFR20, Appendix B, Table 2, Column 2, for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2 E-4 microcurie/milliliter (µCi/ml) total activity at the point of discharge. For dissolved and entrained noble gases, this limit may also be satisfied by using 2E-4 µCi/ml as the MEC for each noble gas. The concentration of radioactivity from Liquid Rad waste batch releases and, if applicable, Service Water System and emergency condenser start-up vent discharges are included in the II 7 CY-NM-170-301 Revision 36 May2017
1.2 Liquid Effluent Concentration Calculation (Cont'd) calculation. The calculation is performed for a specific period of time. No credit taken for averaging. The limiting concentration is calculated as follows: Where: FMEC Cis=(µCi/ml)is The fraction of Maximum Effluent Concentration, the ratio at the point of discharge of the actual concentration to ten times the Effluent Concentration of 10 CPR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For noble gases, the concentration shall be limited to 2 E-4 microcurie/ml total activity. The concentration of nuclide i in particular effluent stream s, µCi/ml. The flow rate of a particular effluent streams, gpm. Maximum Effluent Concentration, ten times the Effluent Concentration of a specific nuclide i from 1 OCFR20, Appendix B, Table 2, Column 2 (noble gas limit is 2E-4 µCi/ml). The total activity rate of nuclide i, in all effluent streams s. The total flow cate lf all effiuent streams s, gpm (including those streams which do not contain radioactivity). A value of less than one for FMEC is considered acceptable for compliance with Part I Section DLCO 3.6.15.a.(l). 1.3 Dose Determinations 1.3.1 Maximum Dose Equivalent Pathway A dose assessment report was prepared for the Nine Mile Point Unit 1 facility by Charles T. Main, Inc., of Boston, MA. This report presented the calculated dose equivalent rates to individuals as well as the population within a 50-mile radius of the facility based on the radionuclides released in liquid and gaseous effluents during the time periods of 1 July 1980 through 31 December 1980 and from January 1981 through 31 December 1981. The rad waste liquid releases are based on a canal discharge rate of 590 ft3 /sec which affects near field and far field dilution; therefore, this report is specific to this situation. Utilizing the effluent data contained in the Annual Radioactive Effluent Release Reports as source terms, dose equivalent rates were determined using the environmental pathway models specified in Regulatory Guides 1.109 and 1.111 as incorporated in the NRC computer codes LADT AP for liquid pathways, and XOQDOQ and GASPAR for gaseous effluent pathways. Dose equivalent rates were calculated for the total body as well as seven organs and/or tissues for the adult, teen, child, and infant age groups. From the standpoint of liquid effluents, the pathways evaluated included fish and drinking water ingestion, and external exposure to water and sediment. II 8 CY-NM-170-301 Revision 36 May 2017
1.3.1 Maximum Dose Equivalent Pathway (Cont'd) The majority of the dose for a radwaste liquid batch release was received via the fish pathway. However, to comply with Part I Specifications for dose projections, the drinking water and sediment pathways are included. Therefore, all doses due to liquid effluents are calculated monthly for the fish and drinking water ingestion pathways and the sediment external pathway from all detected nuclides in liquid effluents released to the unrestricted areas to each organ. The dose projection for liquid batch releases will also include discharges from the emergency condenser vent as applicable, for all pathways. Each age group dose factor, Aiat, is given in Tables 2-1 to 2-8. To expedite time, the dose is calculated for a maximum individual instead of each age group. This maximum individual will be a composite of the highest dose factor of each age group for each organ, hence Ait. The following expression from NUREG 0133, Section 4.3 is used to calculate dose: Where: D1 = L\\TL = CiL = Ai1 The cumulative dose commitment to the total body or any organ, from the liquid effluents for the total time period (L\\ TL), mrem. The length of the L th time period over which CiL and FL are averaged for all liquid releases, hours. The average concentration ofradionuclide, i, in undiluted liquid effluents during time period L\\ TL from any liquid release, µCi/ml. The site related iJgestion dose commitment factor to the total body or any organ t for each identified principal gamma or beta emitter for a maximum individual, mrem/hr per µCi/ml. FL = The near field average dilution factor for CiL during any liquid effluent release. Defined as the ratio of the maximum undiluted liquid waste flow during release to the average flow from the site discharge structure to unrestricted receiving waters, unitless. Aiat values for radwaste liquid batch releases at a discharge rate of295 ft3/sec (one circulating water pump in operation) are presented in tables 2-1 to 2-4. Aiat values for an emergency condenser vent release are presented in tables 2-5 to 2-8. The emergency condenser vent releases are assumed to travel to the perimeter drain system and released from the discharge structure at a rate of.33 ft3/sec. See Appendix A for the dose factor Aiat derivation. To expedite time the dose is calculated to a maximum individual. This maximum individual is a composite of the highest dose factor Aiat of each age group a for each organ t and each nuclide i. If a nuclide is detected for which a factor is not listed, then it will be calculated and included in a revision to the ODCM. All doses calculated in this manner for each batch of liquid effluent will be summed for comparison with quarterly and annual limits, added to the doses accumulated from other releases in the quarter and year of interest. In all cases, the following relationships will hold: II 9 CY-NM-170-301 Revision 36 May 2017
1.3.1 Maximum Dose Equivalent Pathway (Cont'd) For a calendar quarter: D1 _:s 1.5 mrem total body D1 _:s 5 mrem for any organ For the calendar year: Where: D1.:S 3.0 mrem total body D1 _:s 10 mrem for any organ D1 total dose received to the total body or any organ due to liquid effluent releases. If these limits are exceeded, a special report will be submitted to the NRC identifying the cause and proposed corrective actions. In addition, if these limits are exceeded by a factor of two, calculations shall be made to determine if the dose limits contained in 40 CFR 190 have been exceeded. Dose limits, as contained in 40 CFR 190 are total body and organ doses of25 mrem per year and a thyroid dose of75 mrem per year. These calculations will include doses as a result of liquid and gaseous pathways as well as doses from direct radiation. The liquid pathway analysis will only include the fish and sediment pathways since the drinking water pathway is insig!ificant. This pathway is only included in the station's effluent dose projections to comply ith Part I Specifications. Liquid, gaseous and direct radiation pathway doses will cons der the James A. FitzPatrick and Nine Mile Point Unit 2 facilities as well as Nine Mile Point Unit 1 Nuclear Station and the on-site ISFSI facilities. In the event the calculations demonstrate that the 40 CFR 190 dose limits, as defined above, have been exceeded, then a report shall be prepared and submitted to the Commission within 30 days as specified in Part I Section DLCO 3.6.15.d. Section 3.0 of the ODCM contains more information concerning calculations for an evaluation of whether 40 CFR 190 limits have been exceeded. II 10 CY-NM-170-301 Revision 36 May2017
1.3.2 1.3.2.1 1.3.2.2 1.3.2.3 Dose Projections - Determinations of the Need to Operate the Liquid Radwaste Treatment System Requirements DLCO 3.6.16.a requires that the liquid rad waste system be used to reduce the radioactive materials in liquid wastes prior to their discharge when the projected doses due to the liquid effluent would exceed 0.06 mrem to the total body or 0.2 mrem to any organ for the batch. This Control implements Technical Specification 6.5.3.f that requires the Radioactive Effluent Controls Program to include limitations on the functional capability and use of the liquid effluent treatment system to ensure the appropriate portion of this system is used to reduce releases ofradioactivity. This is required when the projected doses would exceed 0.06 mrem to the total body and 0.2 mrem to any organ. Since releases are performed much less frequently than once per month, doses are to be projected prior to each release and the above limits will be applied on a batch basis. Methodology The dose projection for each batch is calculated in the same manner as cumulative dose calculations for the current calendar quarter and current calendar year. See II-1.1.4.4 and II-1.3.1. If the calculated dose is greater than 0.06 mrem to the total body or 0.2 mrem to any organ, the appropriate subsystems of the liquid rad waste system shall be used to reduce the radioactivity levels of the batch prior to release. Continuous Liquid Release Dose Projections Each month that a continuous liquid release is infprogress, or is anticipated, the expected dose to man can be accounted for or projected. ince a continuous release does not result from not operating a portion of the Liquid Radw ste System, projections are not required to determine or evaluate Radwaste System Functionality. Dose projections may be relevant to planning repairs, and in reporting intended actions. See II-1.1.4.5. II 11
- CY-NM-170-301 Revision 36 May2017
2.0 GASEOUS EFFLUENTS 2.1 Setpoint Determinations 2.1.1 Basis Stack gas monitor setpoints will be established such that the instantaneous release rate of radioactive materials in gaseous effluents does not exceed the 10 CPR 20 limits for annual release rate. The setpoints will be activated if the instantaneous dose rate at or beyond the (land) site boundary would exceed 500 mrem/yr to the whole body or 3000 mrem/yr to the skin from the continuous release of radioactive noble gas in the gaseous effluent. The offgas (condenser air ejector activity) monitor setpoints provide assurance that the total body exposure to an individual at the exclusion area boundary does not exceed a small fraction of the dose guidelines of IO CPR 100. Emergency condenser vent monitor setpoints will be established such that the release rate for radioactive materials in gaseous effluents do not exceed the Technical Specification dose rate limits, Monitor setpoints for emergency condenser vent monitors are.conservatively fixed at 5 mr/hr for reasons described in Section 11-2.1.4 and therefore do not require periodic recalculations. Monitor setpoints from continuous release points will be determined once per quarter under normal release rate conditions and will be based on the isotopic composition of the actual release in progress, or an offgas isotopic distribution or a more conservative default composition specified in the pertinent procedure. If the calculated setpoint is higher than the existing setpoint, it is not mandatory that the setpoint be changed. Under abnormal site release rate conditions, monitor alarm setpoints from continuous release points will be recalculated a9d, if necessary, reset at more frequent intervals as deemed necessary by Chemistry Su~ervision. In particular, contributions from both JAP and NMP-2 and the Emergency Condenser Vents shall be assessed. During outages and until steady state power operation is again realized, the last operating stack and off gas monitor alarm setpoints shall be used. Since monitors respond to noble gases only, monitor alarm points are set to alarm prior to exceeding the corresponding whole body dose rates. The skin dose rate limit is not used in setpoint calculations because it is never limiting. 2.1.2 Stack Monitor Setpoints The detailed methods for establishing setpoints shall be contained in the station procedures. These methods shall apply the following general criteria: (1) Rationale for Stack monitor settings is based on the general equation: release rate, actual corresp. dose rate, actual L;Qi L;Qi (¥'; + (SF)K; (X/Q)s) release rate, max. allowable corresp. dose rate, max. allowable (Q)max = 500mrem/ yr II 12 CY-NM-170-301 Revision 36 May 2017
2.1.2 Stack Monitor Setpoints (Cont'd) Where: Q; (Q)max release rate for each isotope i, µCi/sec. gamma whole body dose factor in units of mrem/yr per µCi/sec. (See Table 3-2). instantaneous release rate limit µCi/sec. SF, K;, X/Q = See Section 11-2.2.1.1. (2) (3) (4) (5) To ensure that Part I dose rate limits are not exceeded, the Hi Hi alarms on the stack monitors shall be set lower than or equal to (0.9) (Q)max* }ii alarms shall be set lower than or equal to (0.5) (Q)max* Based on the above conservatism, the dose contribution from JAF and NMP-2 can usually be ignored. During Emergency Classifications at JAF or NMP-2 due to airborne effluent, or after emergency condenser vent releases of significant proportions; the 500 mrem/yr value may be reduced accordingly. To convert monitor gross count rates to µCi/sec release rates, the following general formula shall be applied: (Cm-B) Ks = Q = µCi/sec, release rate Where: Cm B Ks monitor gross count rate in cps or cpm monitor bacW12:round count rate stack monitof efficiency factor with units of µCi/sec-cps or µCi/sec-cpm Monitor Ks factors shall be determined using the general formula: Where: Q; individual radionuclide stack effluent release rate as determined by isotopic analysis. Ks factors more conservative than those calculated by the above methodology may be assumed. Alternatively, when stack release rates are near the lower limit of detection, the following general formula may be used to calculate Ks: Where: f E = 1/K = E s f (2: ; F; L k Yk Ek) (3. 7E4 dis/sec per µCi) f stack flow in cc/sec. efficiency in units of cpm-cc/µCi or cps-cc/µCi ( cpm = counts per minute; cps = counts per second). cpm-cc/bps or cps-cc/yps. From energy calibration curve produced during NIST traceable primary gas calibration or transfer source calibration (bps = beta per second;yps = gammas per second). II 13 CY-NM-170-301 Revision 36 May 2017
2.1.2 Stack Monitor Setpoints (Cont'd) Yk b/d (betas/disintegration) or y/d (gammas/disintegration). Fi Activity fraction of nuclide i in the mixture. = nuclide counter. k discrete energy beta or gamma emitter per nuclide counter. s seconds. This monitor calibration method assumes a noble gas distribution typical of a recoil release mechanism. To ensure that the calculated efficiency is conservative, beta or gamma emissions whose energy is above the range of calibration of the detector are not included in the calculation. 2.1.3 Recombiner Discharge (Off Gas) Monitor Setpoints (1) The Hi-Hi alarm points shall activate with recombiner discharge rates equal to or less than 500,000 µCi/sec. This alarm point inay be set equal to or less than 1 Ci/sec for a period of time not to exceed 60 days provided the offgas treatment system is in operation. According to Part I, Note (c) to Table D 4.6.14-2, the channel functional test of the condenser air ejector radioactivity monitor shall demonstrate that automatic isolation of this pathway occurs if either of the following conditions exist: i) Instruments indicate two channels above the Hi-Hi alarm setpoint, ii) Instruments indicate one channel above Hi-Hi alarm setpoint and one channel downscale. Thil~ automatic isolation function is tested once per operating cycl.J in accordance with stalon procedures. l (2) The Hi alarm points shall be set to activate at equal to or less than five (5) times normal full power background. If the monitor alarms at this setpoint, the offgas will be immediately sampled and analyzed, followed by an analysis ofreactor coolant sample. (3) To convert monitor mR/hr readings to µCi/sec, the formula below shall be applied: (R)(KR) = QR µCi/sec recombiner discharge release rate Where: R mR/hr monitor indicator. KR efficiency factor in units of µCi/sec/mR/hr determined prior to setting monitor alarm points. (4) Monitor KR factors shall be determined using the general formula: Where: Qi = individual radionuclide recombiner discharge release rate as determined by isotopic analysis and flow rate monitor. KR factors more conservative than those calculated by the above methodology may be assumed. II 14 CY-NM-170-301 Revision 36 May 2017
2.1.3 Recombiner Discharge (Off Gas) Monitor Setpoints (Cont'd) (5) The setpoints chosen provide assurance that the total body exposure to an individual at the exclusion area boundary will not exceed a very small fraction of the limits of 1 OCFR Part 100 in the event this effluent is inadvertently discharged directly to the environment without treatment (thereby implementing the requirements of General Design Criteria 60 and 64 of Appendix A to 10CFR Part 50). Additionally, these setpoints serve to limit buildup of fission product activity within the station systems which would result if high fuel leakage were to be permitted over extended periods. 2.1.4
- Emergency Condenser Vent Monitor Setpoint 2.1.5 2.1.5.1 2.1.5.2 The monitor setpoint was established by calculation ("Emergency Condenser Vent Monitor Alarm Setpoint", January 13, 1986, NMPC File Code # 16199). Assuming a hypothetical case with (1) reactor water iodine concentrations higher than the Technical Specification Limit, (2) reactor water noble gas concentrations higher than would be expected at Technical Specification iodine levels, and (3) leakage ofreactor steam into the emergency condenser shell at 300% of rated flow (or 1.3 E6 lbs/hr), the calculation predicts an emergency condenser vent monitor response of20 mR/hr. Such a release would result in less than 10 CFR 20 dose rate values at the site boundary and beyond for typical emergency condenser cooldown periods.
Since a 20 mR/hr monitor response can, in theory, be achievable only when reactor water iodines are higher than permitted by Technical Specifications, a conservative monitor setpoint of 5 mr/hr has been adopted. Discussion !stack Effluent Monitoring System Description The NMP-1 Stack Effluent Monitoring System consisted of two subsystems; the Radioactive Gaseous Effluent Monitoring System (RA GEMS) and the Offgas Effluent Stack Monitoring System (OGESMS). The OGESMS shall be used to monitor station noble gas effluents and collect particulates and iodine samples in compliance with Part I requirements. The RA GEMS was designed to be promptly activated from the Main Control Room for use in high range monitoring during accident situations in compliance with NUREG 0737 criteria. In accordance with a letter dated September 11, 2002 from the NRC to NMPNS, LLC, "Nine Mile Point Nuclear Station Unit 1 - Use of the Offgas Effluent Stack Monitoring System to Meet Regulatory Guide 1.97, Revision 2 and NUREG-073 7," OGESMS meets the objective and purpose ofNUREG-0737 and RG 1.97. The sample line to RAGEMS will now be used as an additional auxiliary sample point. Stack Sample Flow Path - RAGEMS Auxiliary Sample Point The effluent sample is obtained inside the stack at elevation 530' using an isokinetic probe with four orifices. The sample line then bends radially out and back into the stack; descends down the stack and out of the stack at approximately elevation 257'; runs horizontally (enclosed in heat tracing) some 270' along the off gas tunnel; and enters Turbine Building 250' and Offgas Building 247'. II 15 CY-NM-170-301 Revision 36 May 2017
2.1.5.3 2.1.5.4 2.1.5.5 Stack Sample Flow Path - OGESMS The OGESMS sample is obtained from the same stack sample probe as the RAGEMS Auxiliary Sample Point. From the exit of the stack at elevation 257', the sample line runs east approximately 20' and then vertically approximately 8' to the OGESMS skid. In the OGESMS, sample flows thru a particulate/iodine cartridge housing and four noble gas scintillation detectors (i.e., 07 and 08 low range beta detectors and RN-03A and RN-03B high range gamma detectors). From OGESMS, the stack sample flows back into the stack at approximately elevation 257'. All OGESMS detector outputs are monitored and recorded remotely in the Main Control Room. Alarming capabilities are provided to alert Operators of high release rate conditions prior to exceeding Part I Control DLCO 3.6.15.b (l)(a) whole body dose rate limits. Stack particulate and iodine samples are retrieved manually from the OGESMS and analyzed in the laboratory using gamma spectroscopy at frequencies and LLDs specified in Part I Table D 4.6.15-2. Sampling Frequency/Sample Analysis Radioactiv~ gaseous wastes shall be sampled and analyzed in accordance with the sampling and analysis program specified in Part I Table D 4.6.15-2. Noble gas sample and analysis frequencies are increased during elevated release rate conditions. Noble gas sample and analysis are also performed following startup, shutdown and in conjunction with each drywell purge. Particulate samples are saved and analyzed for principal gamma emitters, gross alpha, Fe-55, Sr-89, Sr-90 at monthly intervals minimally, and in response to an increase in noble gas release rate. The latter three analyses are performed off-site from a composite sample. Consistent with Part I Table D 4.6.15-2, stack ef:flJnt tritium is sampled monthly, during each drywell purge, and weekly when fuel is off loaded until stable release rates are demonstrated. Samples may be analyzed on-site or off-site. Line loss correction factors are applied to all particulate and iodine results. Correction factors of2.0 and 1.5 are used for data obtained from RAGEMS Auxiliary Sample Point and OGESMS respectively. These correction factors are based on empirical data from sampling conducted at NMP-1 in 1985 (memo from J. Blasiak to RAGEMS File, 1/6/86, "Stack Sample Representativeness Study: RAGEMS versus In-Stack Auxiliary Probe Samples"). 1-133 and 1-135 Estimates Monthly, the stack effluent shall be sampled for iodines over a 24 hour period and the 1-135/1-131 and the 1-133/I-13 l ratios calculated. These ratios shall be used to calculate 1-133, 1-135 release for longer acquisition samples collected during the month. II 16 CY-NM-170-301 Revision 36 May 2017
2.1.5.5 2.1.5.6 1-133 and 1-135 Estimates (Cont'd) Additionally, the 1-135/1-131 and 1-133/1-131 ratios should also be determined after a significant change in the ratio is suspected ( eg, plant status changes from prolonged shutdown to power operation or fuel damage has occurred). 1-135 will be included in the Radioactive Effluent Release Report in accordance with Regulatory Guide 1.21 but it will not be included when totaling dose rate or dose. Gaseous Radwaste Treatment System Operation Part I Control DLCO 3.6.16.b requires that the gaseous radwaste treatment system shall be functional and shall be used to reduce radioactive materials in gaseous waste prior to their discharge as necessary to meet the requirements of Part I Control DLCO 3.6.15.b. To ensure Part I Control DLCO 3.6.15.b limits are not exceeded, and to confirm proper radwaste treatment system operation as applicable, cumulative dose contributions for the current calendar quarter and current calendar year shall be determined monthly in accordance with section 2.2 of this manual. When actual results for the gross alpha, particulate, iodine, H-3, Sr-89, Sr-90 and Fe-55 concentrations are not available, dose contributions are calculated using concentration estimates. The doses are revised when actual results are obtained. 2.2 Dose and Dose Rate Determinations In accordance with Technical Specifications 6.5.3, "Radioactive Effluent Controls Program, and ODCM Part I Controls DSR 4.6.15.b.(1), DSR 4.6.15.b.(2), and DSR 4.6.15.b.(3) dose and dose rate determinations will be made monthly to determine: (1) (2) (3) Whole body dose rates and gaplma air doses at the maximum X/Q land sector site boundary interface. I Skin dose rates and beta air doses at the maximum X/Q land sector site boundary interface. The critical organ dose and dose rate at a critical receptor location beyond the site boundary. Average meteorological data (ie, maximum five year annual average X/Q and D/Q values in the case of elevated releases or 1985 annual average X/Q and D/Q values, in the case of ground level releases) shall be utilized for dose and dose rate calculations. Where average meteorological data is assumed, dose and dose rates due to noble gases at locations beyond the site boundary will be lower than equivalent site boundary dose and dose rates. Therefore, under these conditions, calculations of noble gas dose and dose rates beyond the maximum X/Q land sector site boundary locations can be neglected. II 17 CY-NM-170-301 Revision 36 May 2017
2.2 Dose and Dose Rate Determinations (Cont'd) The frequency of dose rate calculations will be upgraded when elevated release rate conditions specified in subsequent sections II-2.2.1.1 and 11-2.2.1.2 are realized. I In accordance with Technical Specification 6.5.3.g, noble gas dose rate to the whole body and skin will be calculated at the site boundary. In accordance with Technical Specification 6.5.3.h, gamma and beta air doses may be calculated at a point beyond the site boundary. To demonstrate compliance with Technical Specification 6.5.3, "Radioactive Effluent Controls Program", critical organ doses and dose rates may be conservatively calculated by assuming the existence of a maximum individual. This individual is a composite of the highest dose factor of each age group, for each organ and total body, and each nuclide. It is assumed that all pathways are applicable and the highest X/Q and/or D/Q value for actual pathways as noted in Table 3-1 are in effect. The maximum individual's dose is equal to the same dose that person would receive if they were simultaneously subjected to the highest pathway dose at each critical receptor identified for each pathway. The pathways include grass-(cow and goat)-milk, grass-cow-meat, vegetation, ground plane and inhalation. To comply with Part I requirements the maximum individual dose rate will be calculated at this hypothetical critical residence. If dose or dose rates calculated, using the assumptions noted above, reach Part I limits, actual pathways will be evaluated, and dose/dose rates may be calculated at separate critical receptor locations and compared with applicable limits. Emergency condenser vent release contributions to the monthly dose and dose rate determinations will be considered only when the emergency condenser return isolation valves have been opened for reactor cooldown, if Emergency Condenser tube leaks develop with or without the system's return isolation valve opened, or if significant activity is detected in the Emergency Condenser Sh,11. I Without tube leakage, dose contributions from emergency condenser vent releases are to be determined based on condensate storage tank and emergency condenser shell isotopic distributions. When releases from the emergency condenser have occurred, dose rate and dose determinations shall be performed using methodology in 11-2.2.1 and II-2.2.2. Furthermore, environmental sampling may also be initiated to refine any actual contribution to doses. See Section II-2.4. 2.2.1 Dose Rate Dose rates will be calculated monthly, at a minimum, or when the Hi-Hi stack monitor alarm setpoint is reached, to demonstrate that dose rates resulting from the release of noble gases, tritium, iodines, and particulates with half lives greater than 8 days are within the limits specified in Technical Specifications Section 6.5.3, "Radioactive Effluent Controls Program". These limits are: Noble Gases Whole Body Dose Rate: Skin Dose Rate.: Tritium, Iodines and Particulates Organ Dose Rate: 1500 mrem/yr 500 mrem/yr 3000 mrem/yr II 18 CY-NM-170-301 Revision 36 May2017
2.2.1.1 Noble Gases The following noble gas dose rate equation includes the contribution from the stack (s) elevated release and the emergency condenser vent (v) ground level release when applicable (See section 11-2.2). For whole body dose rates (mrem/sec): DRy (mrem/sec) = 3. l 7E-8 L ; [(V; Q;s + (SF) K; (X/Q)s) Q;s + (SF)K; (X/Q)vQ;v] For skin dose rates (mrem/sec): DRy+p(mrem/sec)= 3.17E-8 L ; [(L;(X/Q)s + 1.1 l(SF)(B; + M;(X/Q)s))Q;5 + Where: DRy = DRy+p = V; K; = Q;s,Qiv = SF = XIQ = L; = B;. = (L; + 1.11 (SF)M;)(X/Q)vQiv] whole body gamma dose rate (mrem/sec). skin dose rate from gamma and beta radiation (mrem/sec). the constant accounting for the gamma whole body dose rate from stack radiation for an elevated finite plume release for each identified noble gas nuclide, i. Listed on Table 3-2 in mrem/yr per µCi/sec. the constant accounting for the gamma whole body dose rate from lmmersion in the semi-infinite cloud for each identified noble gts uclide, i. Listed in Table 3-3 in mrem/yr per µCi/m 3 (from Re. Guide 1.109) the release rate of isotope i from the stack(s) or emergency condenser vent(v); (µCi/sec) structural shielding factor (dimensionless). A shielding factor of 0.7 is discussed in Table E-15 ofRegulatory Guide 1.109 Revision 1. the relative plume concentration (in units of sec/m3) at the land sector site boundary or beyond. Average meteorological data (Table 3-1) is used. "Elevated" X/Q values are used for stack releases (s = stack); "Ground" X/Q values are used for Emergency Condenser Vent releases (v = vent). the constant accounting for the beta skin dose rate from immersion in the semi-infinite cloud for each identified noble gas nuclide, i. Listed in Table 3-3 in mrem/yr per µCi/m3 (from Reg. Guide 1.109) the constant accounting for the gamma air radiation from the elevated Finite plume resulting from stack releases for each identified noble gas nuclide, i. Listed in Table 3-2 in mrad/yr per µCi/sec. II 19 CY-NM-170-301 Revision 36 May 2017
2.2.1.1 2.2.1.2 Noble Gases (Cont'd) the constant accounting for the gamma air dose rate from immersion in the semi-infinite cloud for each identified noble gas nuclide, i. Listed in Table 3-3 in mrad/yr per µCi/m 3 (from Reg. Guide 1.109) See Appendix B for derivation of Bi and Vi, To ensure that the site noble gas dose rate limits are not exceeded, the following procedural actions are taken if the offsite dose rates from Unit 1 exceed 10% of the limits:
- 1)
Notify Unit 1 SM (Shift Manager) and Supervisor Chemistry.
- 2)
Notify Unit 2 SM and Supervisor Chemistry and request the Unit 2 contribution to offsite dose rate.
- 3)
Notify SM of the James A. Fitzpatrick Nuclear Plant and request the Fitzpatrick contribution to offsite dose rate.
- 4)
Increase the frequency of performing noble gas dose and dose rate calculations, if necessary, to ensure Site (Nine Mile Point Units 1 and 2 and Fitzpatrick) limits are not exceeded. Additionally, alarm setpoints are set at 90% of the dose rate limit to ensure that site limits are not exceeded. This alarm setpoint is adjusted if the noble gas dose rate from Unit 1 is greater than 10% of the limit. Tritium, Iodines and Particulates To ensure that the 1500 mrem/year site dose )ate limit is not exceeded, offsite dose rates for tritium, iodine and particulates with half lives greater than 8 days shall be calculated monthly and when release rates (Q) exceed 0.34 µCi/sec using the following equation. Dak (mrem/sec) = 3.17E-8L JL i Rijak [Ws Qis + Wv Qiv)) Where: Dak = Total dose rate to each organ k of an individual in age group a (mrem/sec). Wi dispersion parameter either X/Q (sec/m3) or D/Q (1/m2) depending on pathway and receptor location assumed. Average meteorological data is used (Table 3-1). "Elevated" Wi values are used for stack releases (s = stack); "Ground" Wj values are used for Emergency Condenser Vent releases (v = vent). Qi = the release rate of isotope i, from the stack (s) or vent(v); (µCi/sec). II 20 CY-NM-170-301 Revision 36 May 2017
2.2.1.2 Tritium, Iodines and Particulates (Cont'd) Rijak the dose factor for each isotope i, pathway j, age group a, and organ k (Table 3-4, through 3-22; m2-mrem/yr per µCi/sec for all pathways except inhalation, mrem/yr per µCi/m3* The R values contained in Tables 3-4 through 3-22 were calculated using the methodology defined in NUREG-0133 and parameters from Regulatory Guide 1.109,Revision 1; as presented in Appendix C.
- 3. l 7E-8 = the inverse of the number of seconds in a year.
The use of the 0.34 µCi/sec relea'se rate threshold to perform Unit 1 dose rate calculations is justified as follows: (a) The 1500 mrem/yr organ dose rate limit corresponds to a minimum release rate limit of 0.34 µCi/sec calculated using the equation: 1500 = (Q, µCi/sec) x (RijWj)max Where: 1500 (RijWj)max = site boundary dose rate limit (mrem/year). the maximum curie-to-dose conversion factor equal to 4.34E3 mrem-sec/µCi-yr for Sr-90, child bone for the vegetation pathway at the critical residence receptor location beyond the site boundary for an elevated release. (b) The use of0.34 µCi/sec release rate threshold and the 4.34E3 mrem-sec/µCi-yr curie-tr-dose conversion factor is conservative since curie-to-dose conversion factors for other isotopes likely to be present are significantly lower. If the organ dose rate exceeds 5% of the annual limit, the following procedural actions will be taken:
- 1)
Notify Unit 1 SM (Shift Manager) and Supervisor Chemistry.
- 2)
Notify Unit 2 SM and Supervisor Chemistry and request the Unit 2 contribution to offsite dose rate.
- 3)
Notify SM of James A. Fitzpatrick Nuclear Plant and request JAF's contribution to offsite dose rate.
- 4)
Increase the frequency of performing dose and dose rate calculations if necessary to ensure site (Nine Mile Point Units 1 and 2 and Fitzpatrick) limits are not exceeded. II 21 CY-NM-170-301 Revision 36 May 2017
2.2.2 Dose 2.2.2.1 Calculations will be performed monthly at a minimum, to demonstrate that doses r~sulting from the release of noble gases, tritium, iodines, and particulates with half lives greater than 8 days are within the limits specified in 10 CFR 50, Appendix I. These limits are: Noble Gases 5 mR gamma/calendar quarter 10 mrad beta/calendar quarter 10 mR gamma/calendar year 20 mrad beta/calendar year Tritium, Iodines and Particulates 7.5 mrem to any organ/calendar quarter 15 mrem to any organ/calendar year Noble Gas Air Dose The following Noble Gas air dose equation includes contributions from the stack (s) elevated release and the emergency condenser vent (v) ground level release when applicable (see section II-2.2): For gamma radiation1 (mrad): Dy (mrad) = 3.17E-8 L ; [(Bi+ Mi(.X/Q)s) Qis + Mi(X/Q)v Qiv] t For beta radiation (m~ad): Dp ( mrad) = 3.17E-8 I i N[ (X/Q)s Qis + (X/Q)v Qiv ] t Where: Dy Dp = gamma air dose (mrad). beta air dose (mrad). Note that the units for the gamma air dose are in mrad compared to the units for the limits are in mR. The NRC recognizes that 1 mR=l mrad, for gamma radiation. the constant accounting for the gamma air radiation from the elevated finite plume resulting from stack releases for each identified noble gas nuclide, i. Listed in Table 3-2 in mrad/yr per µCi/sec. the constant accounting for the beta air dose from immersion in the semi-infinite cloud for each identified noble gas nuclide, i. Listed on Table 3-3 in mrad/yr per µCi/m3 (from Reg. Guide 1.109). the release rate of isotope i, from the stack (s) or vent (v); (µCi/sec). II 22 CY-NM-170-301 Revision 36 May2017
2.2.2.1 2.2.2.2 Noble Gas Air Dose (Cont'd) 3.17E-8 t the inverse of the number of seconds in a year. the constant accounting for the gamma air dose from immersion in the semi-infinite cloud for each identified noble gas nuclide, i. Listed on Table 3-3 in mrad/yr per µCi/m3 (from Reg. Guide 1.109). total time during release period, sec. All othe;* parameters are as defined in section II-2.2.1.1. Tritium, Iodines and Particulates To ensure that the 15 mrem/yr facility dose limit is not exceeded, offsite doses for tritium, iodines, and particulates with half lives greater than 8 days shall be calculated monthly using the following equation: Where: Dak 3.17E-8 t Dak (mrem) = 3.17E-8 L iL i Rijak [Ws Qis + Wv Qiv)) t total dose to each organ k of an individual in age group a(mrem). dispersion parameter either X/Q (sec/m3) or D/Q (1/m2) depending on pathway and receptor location assumed. Average meteorological data is used (Table 3-1). "El,vated" Wj values are used for stack releases (s = stack); "Grou~td" Wj values are used for Emergency Condenser Vent releases (v = vent). the release rate of isotope i from stack(s) or vent (v); (µCi/sec). the dose factor for each isotope i, pathway j, age group a, and organ k (Tables 3-4 through 3-7, mrem/yr per µCi/m 3
- Tables 3-8 through 3-22, m2-mrem/yr per µCi/sec). R values contained in Tables 3-4 through 3-22 were calculated using the methodology defined in NUREG-0133 and parameters from Regulatory Guide 1.109, Revision 1; as presented in Appendix C.
the inverse of the number of seconds in a year. total time during the release period, sec. II 23 CY-NM-170-301 Revision 36 May 2017
2.2.2.3 2.2.3 2.2.3.1 Accumulating Doses Doses will be calculated monthly, at a minimum, for gamma air, beta air, and the critical organ for each age group. Dose estimates will, also, be calculated monthly prior to receipt of any offsite or onsite analysis data i.e., strontium, tritium, and iron-55. Results will be summed for each calendar quarter and year. The critical doses are based on the following: noble gas plume air dose direct radiation from ground plane deposition inhalation dose cow milk ingestion dose goat milk ingestion dose cow meat ingestion dose vegetation (food crops) ingestion dose The quarterly and annual results shall be compared to the limits listed in paragraph II-2.2.2. If the limits are exceeded; special reports, as required by Part I Section D 6.9.3 shall be submitted. Dose Projections - Determination of Need to Operate Gaseous Radwaste Treatment System and Ventilation Exhaust Treatment System Requirement DLCO 3.6.16. b requires that the Gaseous Rad waste Treatment System be used to reduce the radioactive materials in gaseous waste prior to their discharge as necessary to meet the requirements ofDLCO 3.6.15. DLCO 3.6.16.b(2) requires that the Ventilation Exhaust Treatment System be used to reduce releases of radioactivity when the projected doses in 31 days would exceed 0.3mrem to any organ. These Controls implement Technical Specification 6.5.3.fthat requires the Radioactive Effluent Control Program to include limitations on the functional capability and use of the gaseous effluent treatment systems (Gaseous Radwaste Treatment System AND Ventilation Exhaust Treatment System) to ensure the appropriate portions of these systems are used to reduce releases ofradioactivity. The Gaseous Radwaste Treatment System is expected to be in service. For the Ventilation Exhaust Treatment $ystem, use is required when the projected doses in a period of 31 days would exceed 2% of the guidelines for the annual dose or dose commitment, conforming to 10CFR50, Appendix I, i.e., 3 mrem to any organ. When Treatment systems are not in use, doses are to be projected every 31 days. The appropriate components, which affect iodine or particulate release, to be in use are: Rad Waste Building FLT-204-24 FLT-204-25 FLT-204-69 FLT-204-70 RSSB FLT-204-147 II 24 CY-NM-170-301 Revision 36 May 2017
2.2.3.2 2.3 Methodology Due to system design and operating procedures the charcoal beds are always operated when the offgas system is in operation. Therefore, dose projection is not relevant to determining need to operate. If the Gaseous Radwaste Treatment System becomes nonfunctional for more than seven days a Special Report to the NRC is required. This report will include appropriate dose assessments ( cumulative and projected). If Ventilation Exhaust Treatment System components become nonfunctional which prevent building effluent from being filtered, dose projections will be performed monthly using the methodology of Section 11-2.2.2.2. Assumptions for released activity will be added to historical routine stack emissions for calculating dose during the anticipated period of component unavailability. The calculated projected doses for iodine and particulates will be compared to the DLCO 3.6.15. b limits and Technical Specifications Section 6.5.3.f limit, 0.3 mrem to any organ. Critical Receptors In accordance with the provisions of 10 CFR 20 and 10 CFR 50, Appendix I, the critical receptors have been identified and are contained in Table 3-1. For elevated noble gas releases the critical receptor is the site boundary. When 1985 average annual X/Q values are used for ground level noble gas releases, the critical receptor is the maximum X/Q land sector site boundary interface. For tritium, iodines, and particulates with halflihs greater than eight days, the critical pathways are grass-( cow and goat)-milk, grass-~ow meat, vegetation, inhalation and direct radiation (ground plane) as a result of ground deposition. The grass-( cow and goat)-milk, and grass-cow-meat pathways will be based on the greatest D/Q location. This location has been determined in conjunction with the land use census (Part I Control DLCO 3.6.22) and is subject to change. The vegetation (food crop) pathway is based on the greatest D/Q garden location from which samples are taken. This location may also be modified as a result of vegetation sampling surveys. The inhalation and ground plane dose pathways will be calculated at the critical residence. Because Part I states to calculate "at the site boundary or beyond", the doses and/or dose rates must be calculated for a maximum individual who is exposed to applicable pathways at the critical residence. The maximum individual is a composite of the highest dose factor of each age group, for each organ and total body, and each nuclide. II 25 CY-NM-170-301 Revision 36 May 2017
2.4 Refinement of Offsite Doses Resulting from Emergency Condenser Vent Releases The doses resulting from the operation of the emergency condensers and calculated in accordance with II-2.2.2 may be refined using data from actual environmental samples. Ground deposition samples will be obtained from an area or areas of maximum projected deposition. These areas are anticipated to be at or near the site boundary and near projected plume centerline. Using the methodology found in Regulatory Guide 1.109, the dose will be calculated to the maximum exposed individual. This dose will then be compared to the dose calculated in accordance with II-2.2.2. The comparison will result in an adjustment factor of less than or greater than one which will be used to adjust the other doses from other pathways. Other environmental samples may also be collected and the resultant calculated doses to the maximum exposed individual compared to the dose calculated per II-2.2.2. Other environmental sample media may include milk, vegetation (such as garden broadleafvegetables), etc. The adjustment factors from these pathways may be applied to the doses calculated per II-2.2.2 on a pathway by pathway basis or several pathway adjustment factors may be averaged and used to adjust calculated doses. Doses calculated from actual environmental sample media will be based on the methodology presented in Regulatory Guide 1.109. The regulatory guide equations may be slightly modified to account for short intervals of time (less than one year) or modified for simplicity purposes by deleting decay factors. Deletion of decay factors would yield more conservative results. II 26 CY-NM-170-301 Revision 36 May2017
3.0 40 CFR 190 REQUIREMENTS The "Uranium Fuel Cycle" is defined in 40 CFR Part 190.02 (b) as follows: "Uranium fuel cycle means the operations of milling of uranium ore, chemical conversion of uranium, isotopic enrichment of uranium, fabrication of uranium fuel, generation of electricity by a light-water-cooled nuclear power plant using uranium fuel, and reprocessing of spent uranium fuel, to the extent that these directly support the production of electrical power for public use utilizing nuclear energy, but excludes mining operations, operations at waste disposal sites, transportation of any radioactive material in support of these operations, and the reuse of recovered non-uranium special nuclear and by-product materials from the cycle." Control DLCO 3.6.15.d of Part I requires that when the calculated doses associated with the effluent releases exceed twice the applicable quarter or annual limits, the licensee shall evaluate the calendar year doses and, if required, submit a Special Report to the NRC and limit subsequent releases such that the dose commitment to a_real individual from all uranium fuel cycle sources is limited to 25 mrem to the total body or any organ ( except the thyroid, which is limited to 75 mrem). This report is to demonstrate that radiation exposures to all real individuals from all uranium fuel cycle sources (including all liquid and gaseous effluent pathways and direct radiation) are less than the limits in 40 CFR Part 190. Ifreleases that result in doses exceeding the 40 CFR 190 limits have occurred, then a variance from the NRC to permit such releases will be requested and if possible, action will be taken to reduce subsequent releases. The report to the NRC shall contain:
- 1)
Identification of all uranium fuel cycle facilities or operations within 5 miles of t~b nuclear power reactor units at the site that contribute to the annual dose of the maximum exposed member of the public.
- 2)
Identification of the maximum exposed member of the public and a determination of the total annual dose to this person from existing pathways and sources of radioactive effluents and direct radiation. The total body and organ doses resulting from radioactive material in liquid effluents from Nine Mile Point Unit 1 will be summed with the maximum doses resulting from the releases of noble gases, radioiodines, and particulates for the other calendar quarters (as applicable) and from the calendar quarter in which twice the limit was exceeded. The direct dose components will be determined by either calculation or actual measurement. Actual measurements will utilize environmental TLD dosimetry. Calculated measurements will utilize engineering calculations to determine a projected direct dose component. In the event calculations are used, the methodology will be detailed as required in Part I Section D 6.9.l.e. II 27 CY-NM-170-301 Revision 36 May 2017
3.0 40 CFR 190 REQUIREMENTS (Cont'd) The doses from Nine Mile Point Unit 1 (including the on-site ISFSI) will be added to the doses to the maximum exposed individual that are contributed from other uranium fuel cycle operations within 5 miles of the site. Other uranium fuel cycle facilities within 5 miles of the Site include Nine Mile Point Nuclear Station Unit 2 and the James A. Fitzpatrick Nuclear Power Plant (including its on-site ISFSI). Doses from other facilities will be calculated in accordance with each facilities' ODCM. For the purpose of calculating doses, the results of the Radiological Environmental Monitoring Program may be included for providing more refined estimates of doses to a real maximum exposed individual. Estimated doses, as calculated from station 1 effluents, may be replaced by doses calculated from actual environmental sample results. Reports will include all significant details of the dose determination if radiological sampling and analyses are used to determine if the dose limits of 40CFR190 are exceeded. 3.1 Evaluation of Doses From Liquid Effluents For the evaluation of doses to real members of the public from liquid effluents, the fish consumption and shoreline sediment ground dose will be considered. Since the doses from other aquatic pathways are insignificant, fish consumption and shoreline sediment are the only two pathways that will be considered. The dose associated with fish consumption may be calculated using effluent data and Regulatory Guide 1.109 methodology or by calculating a dose to man based on actual fish sample analysis data. Because of the nature of the receptor location and the extensive fishing in the area, the critical individual may be a teenager or an adult. The dose associated with shoreline sediment is based on the assumption that the shoreline would be utilized as a recreational area. This dose may be derived frox liquid effluent data and Regulatory Guide 1.109 methodolog~I or from actual shoreline sldiment sample analysis data. Equations used to evaluate doses from actual fish and shoreline sediment samples are based on Regulatory Guide 1.109 methodology. Because of the sample medium type and the half-lives of the radionuclides historically observed, the decay corrected portions of the equations are deleted. This does not reduce the conservatism of the calculated doses but increases the simplicity from an evaluation point of view. Table 3-23 presents the parameters used for calculating doses from liquid effluents. The dose from fish sample media is calculated as: Rapj = L i [Cir(U)(Daipj) f] (1E+3) Where: Rapj The total annual dose to organj, of an individual of age group a, from nuclide i, via fish pathway p, in mrem per year. Cir The concentration of radionuclide i in fish samples in pCi/gram. U The consumption rate offish in kg/yr. 1E + 3 Grams per kilogram. II 28 CY-NM-170-301 Revision 36 May 2017
3.1 Evaluation of Doses From Liquid Effluents (Cont'd) (Daipj) The ingestion dose factor for age group a, nuclide i, fish pathway p, and organj, (Reg. Guide 1.109, Table E-11) (mrem/pCi). f = The fractional portion of the year over which the dose is applicable. The dose from shoreline sedim~nt sample media is calculated as: Rapj = L i [Cis (U)(4E+4)(0.3)(Daipj) fJ Where: Rapj = The total annual dose to organ j, of an individual of age group a, from nuclide i, via the sediment pathway p, in mrem per year. Cis = The concentration of radionuclide i in shoreline sediment in pCi/gram. U The usage factor, (hr/yr) (Reg. Guide 1.109). 4E+4 = The product of the assumed density of shoreline sediment (40 kilogram per square meter to a depth of 2.5 cm) times the number of grams per kilogram. 0.3 = The shore width factor for a lake. Daipj The dose factor for age group a, nuclide i,I sediment pathway s, and organj. (Reg. Guide 1.109, Table E-6)(rnrem/hr per pCi/m2). f = The fractional portion of the year over which the dose is applicable. 3.2 Evaluation of Doses From Gaseous Effluents For the evaluation of doses to real members of the public from gaseous effluents, the pathways contained in section II-2.2.2.3 of the ODCM will be considered. These include the deposition, inhalation cows milk, go/its milk, meat, and food products (vegetation). However, any updated field data may be utilized that concerns locations of real individuals, real time meteorological data, location of critical receptors, etc. Data from the most recent census and sample location surveys should be utilized. Doses may also be calculated from actual environmental sample media, as available. Environmental sample media data such as TLD, air sample, milk sample and vegetable (food crop) sample data may be utilized in lieu of effluent calculational data. Doses to member of the public from the pathways contained in ODCM section II-2.2.2.3 as a result of gaseous effluents will be calculated using the dose factors of Regulatory Guide 1.109 or the methodology of the ODCM, as applicable. Doses calculated from environmental sample media will be based on the methodologies found in Regulatory Guide 1.109. II 29 CY-NM-170-301 Revision 36 May 2017
3.3 Evaluation of Doses From Direct Radiation The dose contribution as a result of direct radiation shall be considered when evaluating whether the dose limitations of 40 CFR 190 have been exceeded. Direct radiation doses as a result of the reactor, turbine and radwaste buildings, the Independent Spent Fuel Storage Installation (ISFSI), and outside radioactive storage tanks (as applicable) may be evaluated by engineering calculations or by evaluating environmental TLD results at critical receptor locations, site boundary or other special interest locations. For the evaluation of direct radiation doses utilizing environmental TLDs, the critical receptor in question, such as the critical residence, etc., will be compared to the control locations. The comparison involves the difference in environmental TLD results between the receptor location and the average control location result. 3.4 Doses to Members of the Public Within the Site Boundary The Radioactive Effluent Release Report shall include an assessment of the radiation doses from radioactive liquid and gaseous effluents to members of the public due to their activities inside the site boundary as defined by Figure 5.1-1 of the Technical Specifications. A member of the public, as defined in Part I, would be represented by an individual who visits the site's Energy Center for the purpose of observing the educational displays or for picnicking and associated activities. Fishing is a major recreational activity in the area and on the Site as a result of the salmonoid and trout populations in Lake Ontario. Fishermen have been observed fishing at the shoreline near the Energy Center from April through December in all weather conditions. Thus, fishing is the major activity performed br members of the public within the site boundary. Based on the nature of the fishermen and t ndocumented observations, it is conservatively assumed that the maximum exposed individua spends an average of 8 hours per week fishing from the shoreline at a location between the Energy Center and the Unit 1 facility. This estimate is considered conservative but not necessarily excessive and accounts for occasions where individuals may fish more on weekends or on a few days in March of the year. The pathways considered for the evaluation include the inhalation pathway, the ground dose pathway with the resultant whole body and skin dose and the direct radiation dose pathway with the associated whole body dose. The direct radiation dose pathway, in actuality, includes several pathways. These include: the direct radiation gamma dose to an individual from an overhead plume, a gamma submersion plume dose (as applicable), possible direct radiation dose from the facility (including the on-site ISFSI) and a ground plane dose ( deposition). Because the location is in close proximity to the site, any beta plume submersion dose is felt to be insignificant. Other pathways, such as the ingestion pathway, are not applicable since these doses are included under calculations for doses to members of the public outside of the site boundary. In addition, pathways associated with water related recreational activities, other than fishing, are not applicable here. These include swimming, boating and wading which are prohibited at the facility. II 30 CY-NM-170-301 Revision 36 May 2017
3.4 Doses to Members of the Public Within the Site Boundary (Cont'd) The inhalation pathway is evaluated by identifying the applicable radionuclides (radioiodine, tritium and particulates) in the effluent for the appropriate time period. The radionuclide concentrations are then multiplied by the appropriate X/Q value, inhalation dose factor, air intake rate, and the fractional portion of the year in question. Thus, the inhalation pathway is evaluated using the following equation adapted from Regulatory Guide 1.109. Table 3-23 presents the reference for the parameters used in the following eqmition. . NOTE: Where: F X/Q The following equation is adapted from equations C~3 and C-4 of Regulatory Guide 1.109. Since many of the factors are in units ofpCi/m3, m3/sec., etc., and since the radionuclide decay expressions have been deleted because of the short distance to the receptor location, the equation presented here is not identical to the Regulatory Guide equations. L i [(Ci)F (X/Q)(DFA)ija(BR)at] The maximum dose from all nuclides to the organ j and age group (a) in mrem/yr. The average concentration in the stack release of nuclide i for the period in pCi/m 3 Unit 1 average stack flowrate in m3/sec. The plume dispersion parameter for a location approxim!ately 0.50 miles west ofNMP-1; the plume dispersion parameter is 8.9E-06 sec/m3 (stack) and was obtained from the C.T. Main five year average annual X/Q tables. The stack ( elevated) X/Q is conservative when based on 0.50 miles because of the close proximity of the stack and the receptor location. (DFA)ija The dose factor for nuclide i, organj, and age group a in mrem per pCi (Reg. Guide 1.109, Table E-7). (BR)a t Annual air intake for individuals in age group a in m3 per year (obtained from Table E-5 of Regulatory Guide 1.109). Fractional portion of the year for which radionuclide i was detected and for which a dose is to be calculated (in years). II 31 CY-NM-170-301 Revision 36 May 2017
3.4 Doses to Members of the Public Within the Site Boundary (Cont'd) The ground dose pathway (deposition) will be evaluated by obtaining at least one soil or shoreline sediment sample in the area where fishing occurs. The dose will then be calculated using the sample results, the time period in question, and the methodology based on Regulatory Guide 1.109 as presented in Section 11-3.1. The resultant dose may be adjusted for a background dose by subtracting the applicable off-site control soil or shoreline sediment sample radionuclide activities. In the event it is noted that fishing is not performed from the shoreline, but is instead performed in the water (i.e., the use of waders), then the ground dose pathway ( deposition) may not be evaluated. The direct radiation gamma dose pathway includes any gamma doses from an overhead plume, potential submersion in the plume, possible direct radiation from the facility (including the on-site ISFSI) and ground plane dose (deposition). This general pathway will be evaluated by average environmental TLD readings. At least two environmental TLDs will be utilized at one location in the approximate area where fishing occurs. The TLDs will be placed in the field on approximately the beginning of a calendar quarter and removed on approximately the end of the calendar quarter. For the purposes *of this evaluation, TLD data from quarters 2, 3, and 4 will be utilized. The average TLD readings will be adjusted by the average control TLD readings. This is accomplished by subtracting the average quarterly control TLD value from the average fishing location TLD value. The applicable quarterly control TLD values will be utilized after adjusting for the appropriate time period ( as applicable). In the event of loss or theft of the TLDs, results from a TLD or TLDs in a nearby area may be utilized. II 32 CY-NM-170-301 Revision 36 May 2017
4.0 ENVIRONMENTAL MONITORING PROGRAM 4.1 Sampling Stations The current sampling locations are specified in Table 5-1 and Figures 5.1-1, 5.1-2. The meteorological tower is shown in Figure 5.1-1. The location is shown as TLD location 17. The Radiological Environmental Monitoring Program is a joint effort between the owners and operators of the Nine Mile Point Unit 1 and the James A. FitzPatrick Nuclear Power Plant. Sampling locations are chosen on the basis of historical average dispersion or deposition parameters from both units. The environmental sampling location coordinates shown on Table 5-1 are based on the NMP-2 reactor centerline. The average dispersion and deposition parameters have been calculated for a 5 year period, 1978 through 1982. These average dispersion or deposition parameters for the site are used to compare results of the annual land use census. If it is determined that sample loc_ations required by Part I are unavailable or new locations are identified that yield a significantly higher (e.g. 50%) calculated D/Q value, actions will be taken as required by Controls DLCO 3.6.20 and DLCO 3.6.22, and the Radiological Environmental Monitoring program updated accordingly. 4.2 Interlaboratory Comparison Program Analyses shall be performed on samples containing known quantities of radioactive materials that are supplied as part of a Commission approved or sponsored Interlaboratory Comparison Program, such as the EPA Crosscheck Program. Participation shall be only for those media, e.g., air, milk, water, etc., that are included in the Nine Mil:1* Point Environmental Monitoring Program and for which crosscheck samples are available. n attempt will be made to obtain a QC sample to program sample ratio of 5% or better. The si e identification symbol or the actual Quality Control sample results shall be reported in the Annual Radiological Environmental Operating Report so that the Commission staff may evaluate the results. Specific sample media for which EPA Cross Check Program samples are available include the following: - gross beta in air particulate filters - gamma emitters in air particulate filters - gamma emitters in milk - gamma emitters in water - tritium in water - I -13 1 in water II 33 CY-NM-170-301 Revision 36 May 2017
4.3 Capabilities for Thermoluninescent Dosimeters Used for Environmental Measurements Required detection capabilities for thermoluminescent dosimeters used for environmental measurements required by Table D 4.6.20-1, footnote b of Part I are based on ANSI Standard N545, section 4.3. TLDs are defined as phosphors packaged for field use. In regard to the detection capabilities for thermoluminescent dosimeters, only one determination is required to evaluate the above capabilities per type ofTLD. Furthermore, the above capabilities may be determined by the vendor who supplies the TLDs. Required detection capabilities are as follows: 4.3.1 Uniformity shall be determined by giving TLDs from the same batch an exposure equal to that resulting from an exposure rate of 10 mR/hr during the field cycle. The responses obtained shall have a relative standard deviation of less than 7.5%. A total of at least 5 TLDs shall be evaluated. 4.3.2 4.3.3 4.3.4 4.3.5 4.3.6 Reproducibility shall be determined by giving TLDs repeated exposures equal to that resulting from an exposure rate of 10 uR/hr during the field cycle. The average of the relative standard deviatfons of the responses shall be less than 3.0%. A total of at least 4 TLDs shall be evaluated. Dependence of exposure interpretation on the length of a field cycle shall be examined by placing TLDs for a period equal to at least a field cycle and a period equal to half the same field cycle in an area where the exposure rate is known to be constant. This test shall be conducted under approximate average winter temperatures and approximate average summer temperatures. For these tests, the ratio of the response obtained in the field cycle to twice that obtained for half the field cycle shall not be less than 0.85. At least 6 TLDs shall be evaluated. I Energy dependence shall be evaluated by the response ofTLDs to photons for several energies between approximately 30 keV and 3 MeV. The response shall not differ from that obtained with the calibration source by more than 25% for photons with energies greater thap 80 keV and shall not be enhanced by more than a factor of two for photons with energies less than 80 keV. A total ofat least 8 TLDs shall be evaluated. The directional dependence of the TLD response shall be determined by comparing the response of the TLD exposed in the routine orientation with respect to the calibration source with the response obtained for different orientations. To accomplish this, the TLD shall be rotated through at least two perpendicular planes. The response averaged over all directions shall not differ from the response obtained in the standard calibration position by more than 10%. A total of at least 4 TLDs shall be evaluated. Light dependence shall be determined by placing TLDs in the field for a period equal to the field cycle under the four conditions found in ANSI N545, section 4.3.6. The results obtained for the unwrapped TLDs shall not differ from those obtained for the TLDs wrapped in aluminum foil by more than 10%. A total of at least 4 TLDs shall be evaluated for each of the four conditions. II 34 CY-NM-170-301 Revision 36 May 2017
4.3.7 Moisture dependence shall be determined by placing TLDs (that is, the phosphors packaged for field use) for a period equal to the field cycle in an area where the exposure rate is known to be constant. The TLDs shall be exposed under two conditions: (1) packaged in a thin, sealed plastic bag, and (2) packaged in a thin, sealed plastic bag with sufficient water to yield observable moisture throughout the field cycle. The TLD or phosphor, as appropriate, shall be dried before readout. The response of the TLD exposed in the plastic bag containing water shall not differ from that exposed in the regular plastic bag by more than 10%. A total of at least 4 TLDs shall be evaluated for each condition. 4.3.8 Self irradiation shall be determined by placing TLDs for a period equal to the field cycle in an area where the expo'sure rate is less than 10 uR/hr and the exposure during the field cycle is known. If necessary, corrections shall be applied for the dependence of exposure interpretation on the length of the field cycle (ANSI N545, section 4.3.3). The average exposure inferred from the responses of the TLDs shall not differ from the known exposure by more than an exposure equal to that resulting from an exposure rate of 10 uR/hr during the field cycle. A total of at least 3 TLDs shall be evaluated. II 35 CY-NM-170-301 Revision 36 May 2017
TABLE 1-1 Average Energy Per Disintegration ISOTOPE Eymev/dis !Rill E~mev/dis<4l .IB!ill. Ar-41 1.294 (3) 0.464 (3) Kr-83m 0.00248 (1) 0.0371 (1) Kr-85 0.0022 (1) 0.250 (1) Kr-85m 0.159 (1) 0.253 (1) Kr-87 0.793 (1) 1.32 (1) Kr-88 1.95 (1) 0.377 (1) Kr-89 2.22 (2) 1.37 (2) Kr-90 2.10 (2) 1.01 (2) Xe-131m 0.0201 (1) 0.143 (1) Xe-133 0.0454 (1) 0.135 (1) Xe-133m 0.042 (1) 0.19 (1) Xe-135 0.247 (1) 0.317 (1) Xe-135m 0.432 (1) 0.095 (1) Xe-137 0.194 (1) 1.64 (1) Xe-138 1.18 (1) 0.611 (1) (1) ORNL-4923, Radioactive Atoms - Supplement I, M.S. Martin, November 1973. (2) NED0-12037, "Summary of Gamma and Beta Emitters and Intensity Data"; M.E. Meek, R.S. Gilbert, January 1970. (The average energy was computed from the maximum energy using the ICRP II equation, not the 1/3 value assumption used in this reference). (3) NCRP Report No. 58, "A Handbook of Radioactivity Measurements Procedures"; 1978 (4) The average energy includes conversion electrons. II 36 CY-NM-170-301 Revision 36 May 2017
TABLE2-1 A;.1 VALUES - LIQUID* RADWASTE TANK INFANT mrem -ml hr - µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 2.90E-l 2.90E-l 2.90E-l 2.90E-l 2.90E-l 2.90E-l Cr 51 l.29E-2 8.39E-3 l.83E-3 l.63E-2 3.75E-l Cu 64 l.13E-l 5.23E-2 l.91E-l 2.32 Mn54 l.87E+l 4.23 4.14 6.86 Fe 55 1.3 lE+ 1 8.44 2.26 4.13 1.07 Fe59 2.84E+l 4.96E+l l.96E+l 1.47E+l 2.37E+l Co 58 3.34 8.34 8.33 Co 60 l.02E+l 2.40E+ 1 2.42E+l. Zn65 1.72E+l 5.91E+l 2.73E+l 2.87E+l 5.00E+l Sr 89 2.32E+3 6.66E+l 4.77E+l Sr 90 l.74E+4 4.43E+3 2.17E+2 Zr95 1.91E-l 4.66E-2 3.30E-2 5.02E-2 2.32E+l Mn56 2.40E-4 4.15E-5 2.07E-4 2.18E-2 Mo99 2.34E+l 4.57 3.50E+l 7.71 Na24 2.37 2.37 2.37 2.37 2.37 2.37 2.37 I 131 3.03E+l 3.57E+l l.57E+l l.17E+4 4.l 7E+ 1 1.28 I 133 4.22 6.15 1.80 I.l2E+3 7.23 1.04 Ni65 1.33E-3 1.51E-4 6.85E-5 l.15E-2 I 132 l.58E-4 3.21E-4 1.14E-4 l.50E-2 3.58E-4 2.60E-4 Cs 134 3.54E+2 6.60E+2 6.67E+l 1.70E+2 6.97E+l 1.79 Cs 136 4.05E+l 1.19E+2 4.45E+l 4.75E+l 9.71E+l 1.81 Cs 137 4.91E+2 5.75E+2 4.07E+l 1.54E+2 6.24E+l 1.80 Ba 140 l.50E+2 l.50E-1 7.74 3.57E-2 9.23E-2 3.69E+l Ce 141 7.21E-2 4.40E-2 5.17E-3 l.36E-2 2.27E+l Nb95 3.85E-2 1.59E-2 9.18E-3 1.14E-2 l.34E+l La 140 l.18E-2 4.67E-3 1.20E-3 5.48E+ 1 Ce 144 2.79 1.14 l.57E-1 4.62E-1 l.60E+2 Calculated in accordance with NUREG 0133, Section 4.3.1; and Regulatory Guide 1.109, Regulatory position C, Section 1. II 37 CY-NM-170-301 Revision 36 May 2017
TABLE2-2 A;a1 VALUES - LIQUID* RADWASTE TANK CHILD mrem -ml hr - µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 4.39E-1 4.39E-1 4.39E-1 4.39E-1 4.39E-1 4.39E-1 Cr 51 2.13E-2 2.13E-2 1.40 7.86E-1 2.30E-1 1.42 7.3IE+l Cu64 2.51E-6 2.70 1.63 2.5IE-6 6.52 2.5IE-6 1.27E+2 Mn54 6.92 3.38E+3 9.06E+2 6.92 9.53E+2 6.92 2.84E+3 Fe 55 9.2IE+2 4.88E+2 1.5IE+2 2.76E+2 9.05E+l Fe 59 I.30E+3 2.1IE+3 1.05E+3 1.34 1.34 6.12E+2 2.19E+3 Co 58 1.89 7.46E+l 2.24E+2 1.89 1.89 1.89 4.26E+2 Co 60 1.12E+2 3.28E+2 7.48E+2 1.12E+2 l.12E+2 1.12E+2 l.3IE+3 Zn 65 2.15E+4 5.73E+4 3.56E+4 3.85 3.6IE+4 3.85 1.0IE+4 Sr 89 3.26E+4 1.IOE-4 9.32E+2 1.IOE-4 1.IOE-4 l.IOE-4 l.26E+3 Sr 90 4.26E+5 1.08E+5 5.74E+3 Zr95 1.70 1.33 1.32 1.23 1.38 1.23 l.08E+2 Mn56 l.65E-1 3.73E-2 2.00E-1 2.39E+l Mo99 5.35E-3 9.57E+l 2.37E+l 5.35E-3 2.04E+2 5.35E-3 7.9IE+l Na24 1.52E+2 l.52E+2 l.52E+2 ~.52E+2 1.52E+2 1.52E+2 l.52E+2 I 131 2.09E+2 2.IOE+2 l.19E+2 .94E+4 3.45E+2 5.60E-2 1.87E+l I 133 3.39E+l 4.19E+l 1.59E+l 7.78E+3 6.98E+l l.38E-4 l.69E+l Ni65 2.67E-1 2.5IE-2 1.47E-2 3.08 I 132 6.13E-3 l.13E-2 5.18E-3 5.22E-1 1.72E-2 l.32E-2 Cs 134 3.68E+5 6.04E+5 1.27E+5 3.54E+l 1.87E+5 6.72E+4 3.29E+3 Cs 136 3.52E+4 9.67E+4 6.26E+4 6.2IE-1 5.15E+4 7.68E+3 3.40E+3 Csl37 5.15E+5 4.93E+5 7.28E+4 5.37E+l 1.6IE+5 5.78E+4 3.14E+3 Ba 140 3.6IE+2 3.96E-1 2.IIE+l 7.96E-2 l.82E-l 2.68E-l l.83E+2 Ce 141 I.SOE-I l.07E-l 6.99E-2 6.34E-2 8.24E-2 6.34E-2 5.40E+l Nb 95 5.2IE+2 2.03E+2 l.45E+2 6.39E-l l.9IE+2 6.39E-l 3.75E+5 La 140 I.SOE-I 5.93E-2 2.68E-2 l.03E-2 1.03E-2 1.03E-2 l.36E+3 Ce 144 5.00 1.81 6.06E-1 3.58E-1 1.16 3.58E-1 3.80E+2 Calculated in accordance with NUREG 0133, Section 4.3.1; and Regulatory Guide 1.109, Regulatory position C, Section 1. II 38 CY-NM-170-301 Revision 36 May 2017
TABLE2-3 A;.1 VALUES - LIQUID* RADWASTE TANK TEEN mrem - ml hr - µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 3.28E-1 3.28E-1 3.28E-1 3.28E-1 3.28E-1 3.28E-1 Cr 51 l.02E-1 1.02E-1 1.39 8.16E-1 3.84E-1 1.94 2.16E+2 Cu 64 l.20E-5 2.89 1.36 l.20E-5 7.32 1.20E-5 2.24E+2 Mn54 3.31E+l 4.34E+3 8.87E+2 3.31E+l 1.32E+3 3.31E+l 8.86E+3 Fe 55 6.94E+2 4.92E+2 1.15E+2 3.12E+2 2.13E+2 Fe 59 l.07E+3 2.49E+3 9.64E+2 6.41 6.41 7.89E+2 5.87E+3 Co 58 9.03 9.82E+l 2.15E+2 9.03 9.03 9.03 l.24E+3 Co 60 5.J6E+2 7.96E+2 l.12E+3 5.36E+2 5.36E+2 5.36E+2 3.93E+3 Zn65 2.10E+4 7.28E+4 3.40E+4 l.84E+ 1 4.66E+4 l.84E+l 3.08E+4 Sr 89 2.44E+4 5.24E-4 6.98E+2 5.24E-4 5.24E-4 5.24E-4 2.90E+3 Sr 90 4.66E+5 1.15E+5 1.31E+4 Zr95 6.20 6.00 5.97 5.90 6.04 5.90 2.28E+2 Mn56 1.8 lE-1 3.22E-2 2.29E-1 1.19E+l Mo99 2.56E-2 9.22E+l 1.76E+l 2.56E-2 2.11E+2 2.56E-2 l.65E+2 Na24 1.39E+2 l.39E+2 11"39E+2 l.39E+2 l.39E+2 l.39E+2 l.39E+2 I 131 1.55E+2 2.I7E+2 l.16E+2 6.31E+4 3.73E+2 2.68E-1 4.30E+l I 133 2.53E+l 4.29E+l 1.31E+l 5.99E+3 7.52E+l 6.60E-4 3.25E+l Ni65 2.08E-1 2.66E-2 1.21E-2 1.44 I 132 4.90E-2 l.28E-2 4.60E-3 4.32E-1 2.02E-2 5.59E-3 Cs 134 3.05E+5 7.18E+5 3.33E+5 l.69E+2 2.28E+5 8.73E+4 9.10E+3 Cs 136 2.98E+4 1.17E+5 7.88E+4 2.97 6.38E+4 1.01E+4 9.44E+3 Cs 137 4.09E+5 5.44E+5 1.90E+5 2.57E+2 1.85E+5 7.21E+4 7.99E+3 Bal40 2.35E+2 4.lOE-1 1.55E+ 1 3.81E-1 4.79E-1 5.75E-1 3.63E+2 Ce 141 3.46E-1 3.32E-1 3.07E-1 3.04E-1 3.17E-1 3.04E-1 8.16E+l Nb95 4.44E+2 2.48E+2 1.18E+2 3.06 2.40E+2 3.06 1.05E+6 Lal40 l.57E-1 l.02E-1 6.35E-2 4.94E-2 4.94E-2 4.94E-2 3.05E+3 Ce 144 3.99 2.65 1.83 1.71 2.27 1.71 5.74E+2 Calculated in accordance with NUREG 0133, Section 4.3.1; and Regulatory Guide 1.109, Regulatory position C, Section 1. II 39 CY-NM-170-301 Revision 36 May 2017
TABLE2-4 A;01 VALUES - LIQUID* RADWASTE TANK ADULT mrem -ml hr- µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 Cr 51 Cu 64 Mn54 Fe 55 Fe 59 Co 58 Co 60 Zn65 Sr 89 Sr 90 Zr95 Mn56 Mo99 Na24 I 131 I 133 Ni65 I 132 Cs 134 Cs 136 Cs 137 Ba 140 Ce 141 Nb95 Lal40 Ce144 4.45E-l 4.45E-l 4.45E-l 4.45E-l 4.45E-l 4.45E-l l.82E-2 1.82E-2 1.27 7.64E-1 2.93E-1 1.67 3.14E+2 i75 1.29 6.94 2.35E+2 5.94 4.38E+3 8.4IE+2 5.94 I.31E+3 5.94 l.34E+4 6.64E+2 4.58E+2 l.07E+2 2.56E+2 2.63E+2 1.03E+3 2.43E+3 9.3IE+2 1.15 1.15 6.79E+2 8.09E+3 1.62 9.15E+l 2.03E+2 1.62 1.62 1.62 l.82E+3 9.60E+l 3.57E+2 6.7IE+2 9.60E+l 9.60E+l 9.60E+l 4.99E+3 2.3IE+4 7.36E+4 3.32E+4 3.30 4.92E+4 3.30 4.63E+4 2.25E+4 9.39E-5 6.45E+2 9.39E-5 9.39E-5 9.39E-5 3.60E+3 5.60E+5 l.37E+5 l.62E+4 1.36 1.15 1.12 1.06 1.21 1.06 3.06E+2 l.73E-1 3.07E-2 2.20E-1 5.52 4.58E-3 8.70E+l l.66E+l 4.58E-3 l.97E+2 4.58E-3 2.02E+2 l.35E+2 l.t5E+2 l.35E+2 l.35E+2 l.35E+2 l.35E+2 l.35E+2 l.45E+2
- 2. 7E+2 l.19E+2 6.79E+4 3.55E+2 4.80E-2 5.47E+ 1 2.35E+l 4.09E+l l.25E+l 6.02E+3 7.14E+l 1.18E-4 3.68E+l l.93E-1 2.5IE-2 l.14E-2 6.36E-1 4.68E-3 l.25E-2 4.38E-3 4.38E-l 2.00E-2 2.35E-3 2.98E+5 7.08E+5 5.79E+5 3.03E+l 2.29E+5 7.6IE+4 l.24E+4 2.96E+4 l.17E+5 8.42E+4 5.32E-1 6.51E+4 8.93E+3 l.33E+4 3.82E+5 5.22E+5 3.42E+5 4.60E+l 1.77E+5 5.90E+4 l.02E+4 2.24E+2 3.49E-l 1,47E+l 6.83E-2 l.64E-1 2.29E-1 4.6IE+2 9.53E-2 8.20E-2 5.75E-2 5.44E-2 6.72E-2 5.44E-2 1.06E+2 4.39E+2 2.44E+2 l.32E+2 5.47E-1 2.41£+2 5.47E-1 l.48E+6 l.llE-1 6.03E-2 2.24E-2 8.84E-3 8.84E-3 8.84E-3 3.78E+3 2.48 1.22 4.24E-1 3.07E-1 8.47E-1 3.07E-1 7.37E+2 Calculated in accordance with NUREG 0133, Section 4.3.1; and Regulatory Guide 1.109, Regulatory position C, Section 1.
II 40 CY-NM-170-301 Revision 36 May 2017
TABLE2-5 Aiat VALUES - LIQUID* EMERGENCY CONDENSER VENT INFANT mrem -ml hr- µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 7.43E-4 7.43E-4 7.43E-4 7.43E-4 7.43E-4 7.43E-4 Cr51 3.30E-5 2.15E-5 4.70E-6 4.18E-5 9.61E-4 Cu64 2.89E-4 l.34E-4 4.89E-4 5.94E-3 Mn54 4.79E-2 l.08E-2 l.06E-2 l.76E-2 Fe 55 3.35E-2 2.16E-2 5.78E-3 l.06E-2 2.75E-3 Fe 59 7.29E-2 l.27E-1 5.02E-2 3.76E-2 6.08E-2 Co 58 8.58E-3 2.14E-2 2.14E-2 Co 60 2.60E-2 6.15E-2 6.19E-2 Zn65 4.42E-2 l.52E-1 6.99E-2 7.35E-2 l.28E-1 Sr 89 5.95 l.71E-1 l.22E-1 Sr 90 4.46E+l l.14E+ 1 5.57E-1 Zr 95 4.90E-4 l.19E-4 8.47E-5 l.29E-4 5.95E-2 Mn56 6.17E-7 l.06E-7 5.30E-7 5.60E-5 Mo99 6.00E-2 l.17E-2 8.97E-2 1.98E-2 Na24 6.07r3 6.07E-3 6.07E-3 6.07E-3 6.07E-3 I ~~07E-3 6.07E-3 I 131 7.77 -2 9.16E-2 4.03E-2 3.0lE+l l.07E-1 3.27E-3 I 133 1.08E-2 l.58E-2 4.62E-3 2.87 l.85E-2 2.67E-3 Ni65 3.41E-6 3.86E-7 l.76E-7 2.94E-5 I 132 4.05E-7 8.22E-7 2.93E-7 3.85E-5 9.l 7E-7 6.66E-7 Cs 134 9.08E-1 1.69 l.71E-1 4.36E-1 1.79E-1 4.60E-3 Cs 136 l.04E-1 3.06E-1 l.14E-1 l.22E-1 2.49E-2 4.64E-3 Cs 137 1.26 1.47 l.04E-1 3.95E-1 1.60E-1 4.61E-3 Bal40 3.85E-1 3.85E-4 l.99E-2 9.15E-5 2.37E-4 9.47E-2 Ce 141 l.85E-4 l.13E-4 l.33E-5 3.48E-5 5.82E-2 Nb95 9.88E-5 4.07E-5 2.35E-5 2.92E-5 3.43E-2 La 140 3.03E-5 l.20E-5 3.08E-6 l.41E-1 Ce144 7.16E-3 2.93E-3 4.02E-4 l.19E-3 4.llE-1 Calculated in accordance with NUREG 0133, Section 4.3.l; and Regulatory Guide 1.109, Regulatory position C, Section 1. II 41 CY-NM-170-301 Revision 36 May 2017
- TABLE2-6 Aiat VALUES - LIQUID*
EMERGENCY CONDENSER VENT CHILD mrem -ml hr- µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 l.44E-1 l.44E-1 1.44E-1 l.44E-1 l.44E-1 l.44E-1 Cr 51 3.78E-5 3.78E-5 1.37 7.58E-1 2.07E-1 1.38 7.24E+l l Cu64 2.63 1.59
- 6.35 l.23E+2 Mn54 1.23E-2 3.36E+3 8.95E+2 1.23E-2 9.42E+2 l.23E-2 2.82E+3 Fe 55 9.04E+2 4.79E+2 l.49E+2 2.71E+2 8.88E+ 1 Fe 59 l.28E+3 2.07E+3 l.03E+3 2.38E-3 2.38E-3 6.00E+2 2.15E+3 Co 58 3.36E-3 7.0lE+l 2.15E+2 3.36E-3 3.36E-3 3.36E-3 4.09E+2 Co 60 l.99E-1 2.08E+2 6.14E+2 l.99E-l 1.99E-l l.99E-l l.15E+3 Zn65 2.15E+4 5.73E+4 3.56E+4 6.84E-3 3.61E+4 6.84E-3 l.01E+4 Sr 89 3.07E+4 8.78E+2 l.19E+3 Sr 90 4.01E+5 l.02E+5 5.40E+3 Zr95 3.0lE-1 6.78E-2 6.06E-2 2.19E-3 9.61E-2 2.19E-3 6.84E+l Mn56 l.65E-1 3.73E-2 2.00E-1 2.39E+l Mo99 8.16E+l 2.02E+l l.74E+2 6.75E+l Na24 l.50E+2 l.50E+2 l.50E+2 l.50E+2 t.50E+2 l.50E+2 l.50E+2 I 131 l.86E+2 l.87E+2 l.06E+2 6.19E+4
.08E+2 1.67E+l I 133 3.08E+l 3.81E+l l.44E+l 7.07E+3 6.35E+l l.53E+l Ni65 2.66E-1 2.50E-2 1.46E-2 3.07 I 132 6.0lE-3 l.lOE-2 5.08E-3 5.12E-1 l.69E-2 l.30E-2 Cs 134 3.68E+5 6.04E+5 l.27E+5 6.29E-2 l.87E+5 6.71E+4 3.25E+3 Cs 136 3.51E+4 9.66E+4 6.25E+4 l.lOE-3 5.14E+4 7.67E+3 3.40E+3 Cs 137 5.14E+5 4.92E+5 7.27E+4 9.55E-2 1.60E+5 5.77E+4 3.08E+3 Ba 140 2.48E+2 2.17E-1
- 1.45E+l l.42E-4 7.09E-2 1.30E-1 1.26E+2 Ce 141 3.08E-2 l.54E-2 2.39E-3 l.13E-4 6.83E-3 l.13E-4 1.91E+l Nb95 5.21E+2 2.03E+2 1.45E+2 l.14E-3 l.90E+2 1.14E-3 3.75E+5 La 140 1.31E-l 4.59E-2 l.55E-2 l.83E-5 l.83E-5 I.83E-5 l.28E+3 Ce 144 1.64 5.15E-1 8.81E-2 6.36E-4 2.85E-1 6.36E-4 l.34E+2 Calculated in accordance with NUREG 0133, Section 4.3.1; and Regulatory Guide 1.109, Regulatory position C, Section 1.
II 42 CY-NM-170-301 Revision 36 May 2017
TABLE2-7 A;at VALUES - LIQUID* EMERGENCY CONDENSER VENT TEEN mrem - ml hr - µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 l.74E-1 l.74E-1 1.74E-1 l.74E-1 l.74E-1 l.74E-1 Cr 51 l.81E-4 l.81E-4 1.28 7.12E-1 2.81E-1 1.83 2.15E+2 Cu 64 2.86 1.35 7.24 2.22E+2 Mn54 5.89E-2 4.29E+3 8.52E+2 5.89E-2 l.28E+3 5.89E-2 8.81E+3 Fe 55 6.89E+2 4.88E+2 l.14E+2 3.10E+2 2.l 1E+2 Fe 59 l.05E+3 2.46E+3 9.50E+2 l.14E-2 1.14E-2 7.76E+2 5.82E+3 Co 58 l.61E-2 8.78E+l 2.02E+2 l.61E-2 l.61E-2 l.61E-2 l.21E+3 Co 60 9.53E-1 2.57E+2 5.78E+2 9.53E-1 9.53E-1 9.53E-1 . 3.34E+3 Zn 65 2.10E+4 7.28E+4 3.39E+4 3.28E-2 4.66E+4 3.28E-2 3.08E+4 Sr 89 2.38E+4 6.81E+2 2.83E+3 Sr 90 4.54E+5 l.12E+5 l.27E+4 Zr95 2.56E-1 8.80E-2 6.38E-2 l.05E-2 l.24E-1 l.05E-2 l.79E+2 Mn56 l.81E-1 3.22E-2 2.29E-1 1.19E+l Mo99 8.57E+l l.63E+l l.96E+2 1.54E+2 Na24 l.38E+2 l.38E+2 l.38E+2 l.tE+2 1.38E+2 l.38E+2 1.38E+2 I 131 l.47E+2 2.06E+2 l.10E+2 6.. OE+4 3.54E+2 4.77E-4 4.07E+l I 133 2.42E+l 4.1 lE+l 1.25E+l 5.74E+3 7.21E+l 3.llE+l Ni65 2.08E-1 2.66E-2 1.21E-2 1.44 I 132 4.86E-3 l.27E-2 4.56E-3 4.29E-1 2.00E-2 5.54E-3 Cs 134 3.05E+5 7.18E+5 3.33E+5 3.0lE-1 2.28E+5 8.71E+4 8.93E+3 Cs 136 2.98E+4 1.17E+5 7.87E+4 5.28E-3 6.38E+4 l.01E+4 9.43E+3 Cs 137 4.09E+5 5.44E+5 1.89E+5 4.57E-1 l.85E+5 7.19E+4 7.73E+3 Ba 140 1.96E+2 2.47E-2 l.27E+ 1 6.77E-4 8.23E-2 1.62E-1 3.03E+2 Ce 141 2.43E-2 1.64E-2 2.36E-3 5.40E-4 8.02E-3 5.40E-4 4.54E+l Nb95 4.41E+2 2.45E+2 1.15E+2 5.43E-3 2.37E+2 5.43E-3 l.05E+6 La 140 l.05E-1 5.17E-2 1.38E-2 8.78E-5 8.78E-5 8.78E-5 2.96E+3 Ce 144 1.27 5.28E-1 7.12E-2 3.04E-3 3.l 7E-1 3.04E-3 3.19E+2 Calculated in accordance with NUREG 0133, Section 4.3.1; and Regulatory Guide 1.109, Regulatory position C, Section 1. II 43 CY-NM-170-301 Revision 36 May2017
I TABLE2-8 Aiat VALUES - LIQUID* EMERGENCY CONDENSER VENT ADULT mrem -ml hr - µCi NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-TRACT H3 2.27E-l 2.27E-l 2.27E-l 2.27E-l 2.27E-l 2.27E-l Cr 51 3.24E-5 3.24E-5 1.24 7.43E-l 2.74E-l 1.65 3.12E+2 Cu64 2.72 1.28 6.86 2.32E+2 Mn54 l.06E-2 4.37E+3 8.33E+2 l.06E-2 l.30E+3 l.06E-2 l.34E+4 Fe 55 6.58E+2 4.55E+2 l.06E+2 2.54E+2 2.61E+2 Fe 59 l.02E+3 2.41E+3 9.22E+2 2.04E-3 2.04E-3 6.72E+2 8.02E+3 co*58 2.88E-3 8.83E+ 1 l.98E+2 2.88E-3. 2.88E-3 2.88E-3 l.79E+3 Co 60 l.71E-l 2.56E+2 5.65E+2 I.71E-l l.71E-l l.71E-l 4.81E+3 Zn 65 2.31E+4 7.36E+4 3.32E+4 5.87E-3 4.92E+4 5.87E-3 4.63E+4 Sr 89 2.18E+4 6.27E+2 3.50E+3 Sr 90 5.44E+5 l.34E+5 l.57E+4 Zr95 2.40E-l 7.81E-2 5.35E-2 l.88E-3 l.22E-l l.88E-3 2.42E+2 Mn56 l.73E-l 3.07E-2 2.20E-l 5.52 Mo99 8.04E+l l.53E+l l.82E+2 l-~34Et l.86E+2 Na24 l.34E+2 l.34E+2 l.34E+2 l.34E+2 l.34E+2 l.34E+2 I 131 l.37E+2 l.96E+2 l.12E+2 6.43E+4 3.36E+2 5.l 7E+l I 133 2.25E+l 3.91E+l 1.19E+l 5.75E+3 6.82E+l 3.51E+l Ni65 l.93E-l 2.50E-2 l.14E-2 6.36E-l I 132 4.64E-3 1.24E-2 4.34E-3 4.34E-l l.98E-2 2.33E-3 Cs 134 2.98E+5 7.08E+5 5.79E+5 5.39E-2 2.29E+5 7.61E+4 l.24E+4 Cs 136 2.96E+4 l.17E+5 8.42E+4 9.46E-4 6.51E+4 8.92E+3 l.33E+4 Cs 137 3.82E+5 5.22E+5 3.42E+5 8.19E-2 l.77E+5 5.89E+4 l.01E+4 Ba 140 l.84E+2 2.32E-l l.21E+l l.21E-4 7.88E-2 l.33E-l 3.79E+2 Ce 141 2.21E-2 l.50E-2 l.78E-3 9.67E-5 7.00E-3 9.67E-5 5.68E+l Nb95 4.38E+2 2.44E+2 l.31E+2 9.73E-4 2.41E+2 9.73E-4 l.48E+6 La 140 9.90E-2 4.99E-2 l.32E-2 l.57E-5 l.57E-5 l.57E-5 3.66E+3 Ce 144 1.17 4.89E-l 6.33E-2 5.45E-4 2.90E-l 5.45E-4 3.95E+2 Calculated in accordance with NUREG 0133, Section 4.3.1; and Regulatory Guide 1.109, Regulatory position C, Section 1. CY-NM-170-301 Revision 36 II 44
- May2017
TABLE3-1 Critical Receptor Dispersion Parametersa For Ground Level and Elevated Releases ELEVATED ELEVATED GROUND" GROUND" LOCATION DIR MILES X/0 {sec/m3} D/0 (m-2} X/O{sec/m 3 } D/0 (m-2} Residences E (98°) 1.4 1.8 E-07b 5.2 E-09b 4.02 E-07 8.58 E-09 Dairy.Cowl SE (130°) 2.6 2.2 E-08c 7.0 E-IOC 6.00 E-08 1.64 E-09 MilkGoatl SE (130°) 2.6 2.2 E-08c 7.0 E-IOC 6.00 E-08 1.64 E-09 Meat Animals ESE (115°) 1.8 5.1 E-08c 1.7 E-09c 1.16 E-07 3.54 E-09 Gardens E (97°) 1.8 1.0 E-07c 3.5 E-09c 2.53 E-07 5.55 E-09 Site Boundary ENE (67°) 0.4 2.4 E-06b,d 4.4 E-08c,d 6.63 E-06 6.35 E-08
- a.
These values will be used in dose calculations beginning in April 1986 but may be revised periodically to account for changes in locations of farms, gardens or critical residences.
- b.
Values based on 5 year annual meteorological data (C.T. Main, Rev. 2)
- c.
Values based on 5 year average grazing season meteorological data.(.C..T. Main Rev. 2)
- d.
Values are based on most restrictive X/Q land-based sector (ENE). (C.T. Main, Rev. 2)
- e.
Values are based on average annual meteorological data for the year 1985.
- f.
Conservative location based on past dairy cow and goat milk history. II 45 CY-NM-170-301 Revision 36 May 2017
Nuclide ! Kr-85 Kr-85m Kr-87 Kr-88 Kr-89 Kr-83m Xe-133 Xe-I33m Xe-135 'Xe-135m Xe-137 Xe-138 Xe-I31m Ar-41 TABLE3-2 Gamma Air and Whole Body Plume Shine Dose Factors* For Noble Gases Gamma Air Bi mrad/yr µCi/sec 2.23E-6 l.75E-3 l.02E-2 2.23E-2 2.50E-2 2.26E-6 2.91E-4 2.27E-4 2.62E-3 5.20E-3 2.30E-3 1.54E-2 l.74E-5 1.64E-2
- Calculated in accordance with Regulatory Guide 1.109. (See Appendix B.)
II 46 Gamma Whole Body Vi ~rem/yr µCi/sec l.68E-3 9.65E-3 2.17E-2 l.71E-2 l.75E-4 l.87E-4 2.50E-3 4.89E-3 2.20E-3 l.03E-2 l.47E-6 l.57E-2 CY-NM-170-301 R~vision 36 .May2017
TABLE3-3 IMMERSION DOSE FACTORS FOR NOBLE GASES* Nuclide
- Kr(x-Body)**
Lj{6-Skin)** M,(y-Air)*** Kr83m 7.56E-02 1.93El Kr85m l.17E3 l.46E3 l.23E3 Kr85 l.61El l.34E3 l.72El Kr87 5.92E3 9.73E3 6.17E3 Kr88 l.47E4 2.37E3 l.52E4 Kr89 l.66E4 l.01E4 l.73E4 Kr90 l.56E4 7.29E3 l.63E4 Xe 131m 9.15El 4.76E2 l.56E2 Xe 133m 2.51E2 9.94E2 3.27E2 Xe 133 2.94E2 3.06E2 3.53E2 Xe 135m 3.12E3 7.11E2 3.36E3 Xe 135 l.81E3 l.86E3 I l.92E3 Xe 137 l.42E3 l.22E4 1.51E3 Xe 138 8.83E3 4.13E3 9.21E3 Ar41 8.84E3 2.69E3 9.30E3 From, Table B-1.Regulatory Guide 1.109 Rev. 1 mrem/yr per µCi/m 3*
- mrad/yr per µCi/m 3*
II 47 N;(D-Air)*** 2.88E2 l.97E3 l.95E3 1.03E4 2.93E3 l.06E4 7.83E3 l.11E3 1.48E3 l.05E3 7.39E2 2.46E3 l.27E4 4.75E3 3.28E3 CY-NM-170-301 Revision 36 May 2017
TABLE3-4 DOSE AND DOSE RATE Ri VALUES-INHALATION - INFANT1 mrem/yr µCi/m 3 NUCLIDE BONE LIVER TBODY THYROID KIDNEY LUNG GI-LLI H3 6.47£2 6.47£2 6.47£2 6.47£2 6.47£2 6.47E2 C 14 2.65£4 5.31E3 5.31E3 5.31E3 5.31E3 5.31E3 5.31E3 Cr 51 8.95El 5.75El l.32El l.28E4 3.57E2 Mn54 2.53E4 4.98£3 4.98£3 1.00E6 7.06E3 Fe 55 1.97E4 1.17E4 3.33E3 8.69E4 1.09E3 Fe 59 l.36E4 2.35E4 9.48E3 1.02E6 2.48E4 Co 58 1.22£3 l.82E3 7.77E5 l.11E4 Co 60 8.02E3 l.18E4 4.51E6 3.19£4 Zn65 1.93£4 6.26£4 3.l 1E4 3.25E4 6.47E5 5.14£4 Sr 89 3.98E5 1.14E4 2.03E6 6.40E4 Sr 90 4.09E7 2.59£6 1.12£7 l.31E5 Zr95 l.15E5 2.79£4 2.03E4 3.11E4 1.75E6 2.17E4 Nb 95 l.57E4 6.43E3 3.78E3 4.72E3 4.79E5 1.27E4 Mo99 l.65E2 3.23El 2.65E2 l.35E5 4.87E4 1-131 3.79E4 4.44E4 l.96E4 1.48E7 5.18E4 1.06£3 I 133 1.32£4 1.92£4 5.60t3 3.56£6 2.24E4 2.16E3 Cs 134 3.96E5 7.03£5 7.45 4 1.90E5 7.97E4 l.33E3 Cs 137 5.49E5 6.12E5 4.55E4 1.72E5 7.13E4 l.33E3 Ba 140 5.60E4 5.60El 2.90£3 l.34El 1.60£6 3.84£4 La 140 5.05E2 2.00E2 5.15El 1.68E5 8.48E4 Ce 141 2.77E4 1.67£4 1.99£3 5.25£3 5.17E5 2.16E4 Ce 144 3.19E6 1.21E6 1.76E5 5.38E5 9.84E6 l.48E5 Nd 147 7.94E3 8.13E3 5.00E2 3.15E3 3.22E5 3.12E4 1 _This and following R; Tables Calculated in accordance with NUREG 0133, Section 5.3.1, except C 14 values in accordance with Regulatory Guide 1.109 Equation C-8. II 48 CY-NM-170-301 Revision 36 May2017
NUCLIDE BONE LIVER H3 1.12E3 C 14 3.59E4 6.73E3 Cr 51 Mn54 4.29E4 Fe 55 4.74E4 2.52E4 Fe 59 2.07E4 3.34E4 Co 58 1.77E3 Co 60 l.31E4 Zn 65 4.26E4 l.13E5 Sr 89 5.99E5 Sr 90 1.0IE8 Zr95 1.90E5 4.18E4 Nb 95 2.35E4 9.18E3 Mo99 1.72E2 I 131 4.81E4 4.8IE4 I 133 1.66E4 2.03E4 I Cs 134 6.5IE5 1.0IE6 Cs 137 9.07E5 8.25E5 Ba 140 7.40E4 6.48El La 140 6.44E2 2.25E2 Ce 141 3.92E4 1.95E4 Cei44 6.77E6 2.12E6 Nd 147 1.08E4 8.73E3 TABLE3-5 DOSE AND DOSE RA TE Ri VALUES - INHALATION - CHILD mrem/yr µCi/m3 TBODY THYROID KIDNEY l.12E3 1.12E3 l.12E3 6.73E3 6.73E3 6.73E3 l.54E2 8.55El 2.43El 9.5IE3 l.OOE4 7.77E3 l.67E4 3.16E3 2.26E4 7.03E4 7.14E4 1.72E4 6.44E6 3.70E4 5.96E4 6.55E3 8.62E3 4.26El 3.92E2 2.73E4 1.62E7 7.88E4 7.70E3 3.85E6 3.38E4 2.25E5 3.30E5 l.28E5 2.82E5 4.33E3 2.1 lEl 7.55El 2.90E3 8.55E3 3.6IE5 l.17E6 6.8IE2 4.81E3 II 49 LUNG GI-LLI 1.12E3 l.12E3 6.73E3 6.73E3 1.70E4 l.08E3 1.58E6 2.29E4 l.11E5 2.87E3 1.27E6 7.07E4 1.l 1E6 3.44E4 7.07E6 9.62E4 9.95E5 l.63E4 2.16E6 1.67E5 1.48E7 3.43E5 2.23E6 6.1IE4 6.14E5 3.70E4 l.35E5 l.27E5 2.84E3 1.2IE5 I 5.48E3 3.85E3 l.04E5 3.62E3 1.74E6 l.02E5 l.83E5 2.26E5 5.44E5 5.66E4 1.20E7 3.89E5 3.28E5 8.21E4 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H3 1.27E3 C 14 2.60E3 4.87E3 Cr 51 Mn54 5.IIE4 Fe 55 3.34E4 2.38E4 Fe 59 l.59E4 3.70E4 Co 58 2.07E3 Co 60 l.51E4 Zn 65 3.86E4 l.34E5 Sr 89 4.34E5 Sr 90 l.08E8 Zr95 l.46E5 4.58E4 Nb 95 l.86E4 l.03E4 Mo99 l.69E2 I 131 3.54E4 4.91E4 I 133 1.22E4 2.05E4 Cs 134 5.02E5 l.13E6 Cs 137 6.70E5 8.48E5 Ba 140 5.47E4 6.70EI La 140 4.79E2 2.36E2 Ce 141 2.84E4 l.90E4 Ce144 4.89E6 2.02E6 Nd 147 7.86E3 8.56E3 TABLE3-6 DOSE AND DOSE RA TE R; VALUES - INHALATION -TEEN mrem/yr µCi/m 3 TBODY THYROID KIDNEY 1.27E3 1.27E3 L27E3 4.87E3 4.87E3 4,87E3 l.35E2 7.50EI 3.07El 8.40E3 1.27E4 5.54E3 1.43E4 2.78E3 l.98E4 6.24E4 8.64E4 l.25E4 6.68E6 3.15E4 6.74E4 5.66E3 l.OOE4 3.22EI 4.11E2 2.64E4 l.46E7 8.40E4 6.22E3 2.92E6 3.59E4 5.49E5 3.75E5 3.11E5 3.04E5 3.52E3 2.28EI 6.26EI 2.17E3 8.88E3 2.62E5 l.21E6 5.13E2 5.02E3 II 50 LUNG GI-LLI 1.27E3 l.27E3 4.87E3 4.87E3 , 2.10E4 3.00E3 1.98E6 6.68E4 l.24E5 6.39E3 1.53E6 1.78E5 l.34E6 9.52E4 8.72E6 2.59E5 1.24E6 4.66E4 2.42E6 3.71E5 l.65E7 7.65E5 2.69E6 l.49E5 7.51E5 9.68E4 l.54E5 2.69E5 6.49E3 l~-.46E5 l.03E4 9.76E3 l.21E5 8.48E3 2.03E6 2.29E5 2.14E5 4.87E5 6.14E5 1.26E5 l.34E7 8.64E5 3.72E5 1.82E5 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H3 l.26E3 C 14 l.82E4 3.41E3 Cr 51 Mn54 3.96E4 Fe 55 2.46E4 l.70E4 Fe 59 1.18E5 2.78E4 Co 58 l.58E3 Co 60 1.15E4 Zn 65 3.24E4 l.03E5 Sr 89 3.04E5 Sr 90 9.92E7 Zr95 l.07E5 3.44E4 Nb95 l.41E4 7.82E3 Mo99 l.21E2 I 131 2.52E4 3.58E4 I 133 8.64E3 1.48E4 Cs 134 3.73E5 8.48E5 Cs 137 4.78E5 6.21E5 Ba 140 3.90E4 4.90El La 140 3.44E2 l.74E2 Ce 141 l.99E4 l.35E4 Ce 144 3.43E6 l.43E6 Nd 147 5.27E3 6.IOE3 TABLE3-7 DOSE AND DOSE RA TE R; V ALOES - INHALATION - ADULT mrem/yr µCi/m3 TBODY THYROID KIDNEY l.26E3 l.26E3 l.26E3 3.41E3 3.41E3 3.41E3 l.OOE2 5.95El 2.28El 6.30E3 9.84E3 3.94E3 l.06E4 2.07E3 l.48E4 4.66E4 6.90E4 8.72E3 6.10E6 2.33E4 5.42E4 4.21E3 7.74E3 2.30El 2.91E2 2.05E4 l.19E7 6.13E4 4.52E3 2.15E6 2.l8E4 7.28E5
- 2. 7E5 4.28E5 2.22E5 2.57E3 l.67El 4.58El 1.53E3 6.26E3 l.84E5 8.48E5 3.65E2 3.56E3 II 51 LUNG GI-LLI l.26E3 l.26E3 3.41E3 3.41E3 l.44E4 3.32E3 1.40E6 7.74E4 7.21E4 6.03E3 l.02E6 l.88E5 9.28E5 l.06E5 5.97E6 2.85E5 8.64E5 5.34E4 l.40E6 3.50E5 9.60E6 7.22E5 l.77E6 l.50E5 5.05E5 l.04E5 9.12E4 2.48E5 6.28E3 8.88E3 9.76E4 l.04E4 7.52E4 8.40E3 1.27E6 2.18E5 1.36E5 4.58E5 3.62E5 1.20E5 7.78E6 8.16E5 2.21E5 l.73E5 CY-NM-170-301 Revision 36 May 2017
NUCLIDE H3 C 14 Cr 51 Mn54 Fe 55 Fe 59 Co58 Co 60 Zn65 Sr 89 Sr90 Zr95 Nb95 Mo99 I 131 I 133 Cs 134 Cs 137 Ba 140 La 140 Ce 141 Ce 144 Nd 147 TABLE3-8 DOSE AND DOSE RATE R; VALUES - GROUND PLANE ALL AGE GROUPS m2-mrem/yr µCi/sec TOTAL BODY 4.65E6 l.40E9 2.73E8 3.80E8 2.15EI0 7.46E8 2.16E4 2.45E8 l.36E8 3.99E6 l.72E7 2.39E6 6.83E9 l.03EI0 2.05E7 l.92E7 l.37E7 6.96E7 8.46E6 II 52 SKIN 5.50E6 l.64E9 3.20E8 4.45E8 2.53EI0 8.57E8 2.51E4 2.85E8 l.61E8 4.63E6 2.09E7 2.91E6 7.97E9 l.20EI0 2.35E7 2.18E7 1.54E7 8.07E7 l.OIE7 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H3* 2.38E3 C 14* 3.23E6 6.89E5 I Cr51 I Mn54 2.5IE7 Fe 55 8.43E7 5.44E7 I Fe 59 l.22E8 2.13E8; Co 58 1.39E7 Co 60 5.90E7 Zn65 3.53E9 l.21EIO Sr 89 6.93E9 Sr 90 8.19El0 Zr 95 3.85E3 9.39E2 Nb95 4.2IE5 l.64E5 Mo99 l.04E8 I 131 6.8IE8 8.02E8
- I 133 8.52E6 l.24E7 Cs 134 2.4IE10 4.49E10 Cs 137 3.47EI0 4.06EI0 Ba 140 l.2IE8 l.2IE5 La 140 2.03El 7.99 Ce 141 2.28E4 1.39E4 Ce 144 l.49E6 6.10E5 Nd 147 4.43E2 4.55E2
- mi:em!yr per µCi/m3*
TABLE3-9 DOSE AND DOSE RATE Ri VALUES-COW MILK-INFANT m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 2.38E3 2.38E3 2.38E3 6.89E5 6.89E5 6.89E5 8.35E4 5.45E4 l.19E4 I 5.68E6 5.56E6 1.45E7 8.38E7 3.46E7 l.39E8 5.58E9 5.87E9 l.99E8 2.09EI0 6.66E2 l.OIE3 l.17E5 l.54E5 2.03E7 l.55E8 3.53E8 2.64Ell 9.37E8 3.63E61 2.26E9 1.46E7 4.54E9 1.16EI0 2.88E9 l.09EI0 6.22E6 2.87E4 2.06 1.64E3 4.28E3 8.34E4 2.46E5 2.79El l.76E2 II 53 LUNG GILLI 2.38E3 2.38E3 6.89E5 6.89E5 l.06E5 2.43E6 9.2IE6 2.66E7 6.9IE6 6.29E7 l.02E8 3.46E7 l.40E8 l.02E10 l.42E8 l.02E9 4.68E5 3.03E8 3.43E7 2.86E7 2.IOE6 4.74E9 l.22E8 4.4IE9 l.27E8 7.42E4 2.97E7 9.39E4 7.18E6 8.54E7 2.89E5 CY-NM-170-301 Revision 36 May2017
NUCLIDE BONE LIVER H3* l.57E3 C 14* l.65E6 3.29E5 Cr 51 Mn54 l.35E7 Fe 55 6.97E7 3.07E7 Fe 59 6.52E7 l.06E8 Co 58 6.94E6 Co 60 2.89E7 Zn65 2.63E9 7.00E9 Sr 89 3.64E9 Sr 90 7.53E10 Zr95 2.17E3 4.77E2 Nb95 1.86E5 l.03E4 Mo99 4.07E7 I 131 3.26E8 3.28E8 I 133 4.04r 4.99E6 Cs 134 1.50 10 2.45EI0 Cs 137 2.l 7EI0 2.08EI0 Ba 140 5.87E7 5.I4E4 La 140 9.70 3.39 Ce 141 l.15E4 5.73E3 Ce 144 l.04E6 3.26E5 Nd 147 2.24E2 1.8IE2
- mrem/yr per µCi/m3*
TABLE3-10 DOSE AND DOSE RATE Ri VALUES - COW MILK - CHILD m 2-mrem/yr µCi/sec TBODY THYROID KIDNEY l.57E3 l.57E3 l.57E3 3.29E5 3.29E5 3.29E5 5.27E4 2.93E4 7.99E3 3.59E6 3.78E6 l.15E7 5.26E7 2.13E7 8.52E7 4.35E9 4.4IE9 l.04E8 l.91EIO 4.25E2 6.83E2 5.69E4 l.OOE5 l.OIE7 8.69E7 l.86E8 l.08EI1 5.39E8 l.89E6 9.27E8 8.32E6 5.I8E9 7.6IE9 3.07E9 6.78E9 3.43E6 l.67E4 1.14 8.5IE2 2.5IE3 5.55E4 l.80E5 l.40El 9.94El II 54 LUNG GI-LLI l.57E3 l.57E3 3.29E5 3.29E5 5.34E4 2.80E6 l.13E7 2.09E7 6.85E6 3.06E7 l.IOE8 4.05E7 l.60E8 l.23E9 l.4IE8 1.0IE9 4.98E5 4.42E8 3.37E7 2.92E7 2.0IE6 2.73E9 l.32E8 2.44E9 I.30E8 3.07E4 2.97E7 9.45E4 7.15E6 8.49E7 2.87E5 CY-NM-170-301 Revision 36 . May 2017
NUCLIDE BONE LIVER Hf 9.94E2 C 14* 6.70E5 l.34E5 Cr 51 Mn54 9.01E6 Fe 55 2.78E7 l.97E7 Fe 59 2.81E7 6.57E7 Co 58 4.55E6 Co 60 l.86E7 Zn65 l.34E9 4.65E9 Sr 89 1.47E9 Sr 90 4.45El0 Zr95 9.34E2 2.95E2 Nb95 l.86E5 l.03E5 Mo99 2.24E7 I 131 l.34E8 l.88E8 I 133 I l.66E6 2.82E6 Cs 134 6.49E9 l.53E10 Cs 137 9.02E9 l.20EIO Ba 140 2.43E7 2.98E4 La 140 4.05 1.99 Ce 141 4.67E3 3.12E3 Ce 144 4.22E5 l.74E5 Nd 147 9.12El 9.91El
- mrem/yr per µCi/m3*
TABLE 3-11 DOSE AND DOSE RA TE R; VALVES - COW MILK - TEEN m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 9.94E2 9.94E2 9.94E2 l.34E5 l.34E5 l.34E5 2.58E4 l.44E4 5.66E3 l.79E6 2.69E6 4.59E6 2.54E7 l.05E7 4.19E7 2.17E9 2.97E9 4.21E7 1.lOElO 2.03E2 4.33E2 5.69E4 1.00E5 4.27E6 5.12E7 l.01E8 5.49E10 3.24E8 8.59E5 3.93E8 4.94E6 7.08E9 4.85E9 4.18E9 4.08E9 l.57E6 l.01E4 5.30E-1 3.58E2 l.47E3 2.27E4 l.04E5 5.94EO 5.82El II 55 LUNG GI-LLI 9.94E2 9.94E2 l.35E5 l.34E5 3.69E4 4.34E6 l.85E7 1.25E7 8.52E6 2.07E7 l.55E8 6.27E7 2.42E8 l.97E9 l.75E8 1.25E9 6.80E5 4.42E8 4.01E7 3.72E7 2.13E6 1.85E9 l.90E8 1.59E9 1.71E8 2.00E4 3.75E7 1.14E5 8.91E6 1.06E8 3.58E5 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER Hf 7.63E2 C 14* 3.63E5 7.26E4 Cr 51 Mn54 5.41E6 Fe 55 l.57E7 l.08E7 Fe 59 l.61E7 3.79E7 Co 58 2.70E6 Co 60 l.10E7 Zn 65 8.71E8 2.77E9 Sr 89 7.99E8 Sr 90 3.15El0 Zr 95 5.34E2 l.71E2 Nb95 1.09E5 6.07E4 Mo99 1.24E7 I 131 7.41E7 l.06E8 I 133 9.09E5 1.58E6 Cs 134 3.74E9 8.89E9 Cs 137 4.97E9 6.80E9 Ba 140 l.35E7 l.69E4 La 140 2.26 1.14 Ce 141 2.54E3 l.72E3 Ce144 2.29E5 9.58E4 Nd 147 4.74El 5.48El
- mrem/yr per µCi/m 3
TABLE3-12 DOSE AND DOSE RATE R; VALUES - COW MILK - ADULT m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 7.63E2 7.63E2 7.63E2 7.26E4 7.26E4 7.26E4 1.48E4 8.85E3 3.26E3 l.03E6 l.61E6 2.52E6 1.45E7 6.05E6 2.42E7 1.25E9 l.85E9 2.29E7 7.74E9 l.16E2 2.69E2 3.27E4 6.00E4 2.36E6 2.81E7 6.08E7 3.47E10 l.82E8 4.82E5 ) 2.32E8 2.76E6 7.27E9 2.88E9 4.46E9 2.31E9 8.83E5 5.75E3 3.0lE-1 l.95E2 7.99E2 l.23E4 5.68E4 3.28EO 3.20El II 56 LUNG GI-LLI 7.63E2 7.63E2 7.26E4 7.26E4 1.96E4 3.72E6 l.66E7 6.04E6 6.21E6 1.06E7 l.26E8 5.47E7 2.06E8 l.75E9 1.28E8 9.11E8 5.43E5 3.69E8 2.87E7 2.80E7 l.42E6 9.55E8 l.56E8 7.68E8 l.32E8 9.69E3 2.77E7 8.35E4 6.58E6 7.74E7 2.63E5 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER Hf 6.33E3 C 14* 3.23E6 6.89E5 Cr 51 Mn54 3.01E6 Fe 55 1.10E6 7.08E5 Fe 59 1.59E6 2.78E6 Co 58 l.67E6 Co60 7.08E6 Zn65 4.24E8 1.45E9 Sr 89 l.48El0 Sr 90 l.72Ell Zr95 4.66E2 l.13E2 Nb 95 9.42E4 3.88E4 Mo99 l.27E7 I 131 8.17E8 9.63E8 Il33 l.02E7 l.49E7 Cs 134 7.23E10 l.35Ell Cs 137 l.04Ell l.22El 1 Ba 140 l.45E7 l.45E4 La 140 2.43EO 9.59E-l Ce 141 2.74E3 l.67E3 Ce 144 l.79E5 7.32E4 Nd 147 5.32El 5.47El
- mrem/yr per µCi/m 3
TABLE3-13 DOSE AND DOSE RATE R; VALUES - GOAT MILK-INFANT m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 6.33E3 6.33E3 6.33E3 6.89E5 6.89E5 6.89E5 l.OOE4 6.56E3 1.43E3 6.82E5 6.67E5 1.89E5 l.09E6 4.16E6 l.67E7 6.70E8 7.04E8 4.24E8 4.38EIO 8.04El l.22E2 2.24E4 2.78E4 2.47E6 1.89E7 4.23E8 3.16El 1 l.12E9 4f 36E6 2.71E9 1.75E7 l.36EI0 3.47EI0 8.63E9 3.27EI0 7.48E5 3.44E3 2.47E-l l.96E2 5.14E2 1.00E4 2.96E4 3.35EO 2.1 lEl II 57 LUNG GI-LLI 6.33E3 6.33E3 6.89E5 6.89E5 l.28E4 2.93E5 j l.11E6 3.46E5 8.98E4 8.21E5 l.33E6 4.16E6 l.68E7 l.23E9 3.04E8 2.15E9 5.65E4 3.27E7 4.17E6 3.44E7 l.42EI0 2.52E6 I 3.66E8 l.32EI0 3.81E8 8.91E3 3.56E6 l.13E4 8.62E5 l.03E7 3.46E4 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H3* 4.17E3 C 14* l.65E6 3.29E5 Cr 51 Mn54 l.62E6 Fe 55 9.06E5 4.8IE5 Fe 59 8.52E5 l.38E6 Co 58 8.35E5 Co 60 3.47E6 Zn 65 3.15E8 8.40E8 Sr 89 7.77E9 Sr 90 1.58Ell Zr95 2.62E2 5.76El Nb95 5.05E4 l.96E4 Mo99 4.95E6 I 131 3.9IE8 3.94E8 I 133 4.84E6 5.99j6 Cs 134 4.49E10 7.37 10 Cs 137 6.52E10 6.24E10 Ba 140 7.05E6 6.18E3 La140 l.16EO 4.07E-1 Ce 141 l.38E3 6.88E2 Ce144 l.25E5 3.9IE4 Nd 147 2.68El 2.17El
- mrem/yr per µCi/m3
- TABLE3-14 DOSE AND DOSE RA TE Ri VALUES - GOAT MILK-CHILD m
2-mrem/yr µCi/sec TBODY THYROID KIDNEY 4.17E3 4.17E3 4.17E3 3.29E5 3.29E5 3.29E5 6.34E3 3.52E3 9.62E2 4.3IE5 4.54E5 l.49E5 6.86E5 2.56E6 1.02E7 5.23E8 5.29E8 2.22E8 4.0IE10 5.13El 8.25El 1.40E4 l.85E4 l.22E6 1.06E7 2.24E8 l.30Ell 6.46E8 2.27E6 l.11E9 9.98E6 l.55EI0 2.28El0 9.2IE9 2.03E10 4.12E5 2.0IE3 l.37E-1 1.02E2 3.02E2 6.66E3 2.16E4 1.68EO l.19El II 58 LUNG GI-LLI 4.17E3 4.17E3 3.29E5 3.29E5 6.43E3 3.36E5 l.36E6 2.72E5 8.9IE4 3.99E5 l.43E6 4.87E6 l.92E7 1.48E8 3.0IE8 2.13E9 6.0IE4 3.63E7 4.09E6 3.50E7 2.4IE6 8.19E9 3.97E8 7.32E9 3.9IE8 3.68E3 3.57E6 l.13E4 8.59E5 1.02E7 3.44E4 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER Hf 2.64E3 C 14* 6.70E5 1.34E5 Cr 51 Mn54 l.08E6 Fe 55 3.61E5 2.56E5 Fe 59 3.67E5 8.57E5 Co 58 5.46E5 Co 60 2.23E6 Zn65 l.61E8 5.58E8 Sr 89 3.14E9 Sr 90 9.36E10 Zr95 l.13E2 3.56El Nb95 2.23E4 1.24E4 Mo99 2.72E6 I 131 l.61E8 2.26E8 I 133 1.99E6 j 3.38E6 Cs 134 l.95El 4.58E10 Cs 137 2.71El0 3.60E10 Ba 140 2.92E6 3.58E3 La 140 4.86E-1 2.39E-1 Ce 141 5.60E2 3.74E2 Ce 144 5.06E4 2.09E4 Nd 147 l.09El l.19El
- mrem/yr per µCi/m3
- TABLE3-15 DOSE AND DOSE RA TE Ri VALUES - GOAT MILK - TEEN m2-mrem/yr
µCi/sec TBODY THYROID KIDNEY 2.64E3 2.64E3 2.64E3 l.34E5 1.34E5 l.34E5 3.11E3 l.73E3 6.82E2 2.15E5 3.23E5 5.97E4 3.31E5 l.26E6 5.03E6 2.60E8 3.57E8 8.99E7 2.31El0 2.45El 5.23El 6.82E3 l.20E4 5.19E5 6.23E6 l.21E8 6.59E10 3.89E8 l.03E6 4.72E8 5.93E6 2.13El0 l.46E10 l.25El0 l.23El0 l.88E5 l.21E3 6.36E-2 4.30El l.76E2 2.72E3 1.25E4 7.13E-l 6.99EO II 59 LUNG GI-LLI 2.64E3 2.64E3 l.35E5 l.34E5 4.44E3 5.23E5 2.22E6 l.62E5 l.11E5 2.70E5 2.03E6 7.53E6 2.91E7 2.36E8 3.74E8 2.63E9 8.22E4 5.30E7 4.87E6 4.47E7 2.56~6 5.56E9 5.70~8 4.76E9 5.12E8 2.41E3 4.50E6 l.37E4 1.07E6 1.27~7 4.29E4 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H 3* 2.03E3 Clf 3.63E5 7.26E4 Cr 51 Mn54 6.50E5 Fe 55 2.04E5 l.41E5 Fe 59 2.IOE5 4.95E5 Co 58 3.25E5 Co60 1.32E6 Zn 65 l.05E8 3.33E8 Sr 89 l.70E9 Sr 90 6.62El0 Zr95 6.45El 2.07El Nb 95 l.31E4 7.29E3 Mo99 l.51E6 I 131 8.89E7 1.27E8 I 133 l.09E6 l.90E6 Cs 134 1.12E10 2.67El0 Cs 137 l.49E10 2.04El0 Ba 140 l.62E6 2.03E3 Lal40 2.71E-l l.36E-1 Ce 141 3.06E2 2.07E2 Ce144 2.75E4 I.l5E4 Nd 147 5.69EO 6.57EO
- mrem/yr per µCi/m3*
TABLE3-16 DOSE AND DOSE RA TE Ri VALUES - GOAT MILK - ADULT m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 2.03E3 2.03E3 2.03E3 7.26E4 7.26E4 7.26E4 l.78E3 l.06E3 1 3.92E2 l.24E5 l.93E5 3.28E4 l.90E5 7.27E5 2.91E6 l.51E8 2.23E8 4.89E7 l.63El0 l.40El 3.25El 3.92E3 7.21E3 2.87E5 3.41E6 7.29E7 4.17E10 2.18E8 5.79E5 2.79E8 I 3.31E6 2.18E10 8.63E9 l.34E10 6.93E9 l.06E5 6.91E2 3.61E-2 2.34El 9.60El l.48E3 6.82E3 3.93E-l 3.84EO II 60 LUNG GI-LLI 2.03E3 2.03E3 7.26E4 7.26E4 2.36E3 4.48E5 l.99E6 7.85E4 8.07E4 l.38E5 l.65E6 6.58E6 2.48E7 2.IOE8 2.73E8 l.91E9 6.56E4 4.42E7 3.49E6 3.36E7 l.71E6 2.86E9 4.67E8 2.30E9 3.95E8 1.16E3 3.33E6 1.00E4 7.90E5 9.30E6 3.15E4 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER Hf 2.34E2 C 14* 5.29E5 l.06E5 Cr 51 Mn54 5.15E6 Fe 55 2.89E8 l.53E8 Fe 59 2.04E8 3.30E8 Co 58 9.41E6 Co 60 4.64E7 Zn65 2.38E8 6.35E8 Sr 89 2.65E8 Sr 90 7.01E9 Zr 95 l.51E6 3.32E5 Nb 95 4.10E6 l.59E6 Mo99 5.42E4 I 131 4.15E6 4.18E6 I 133 9.38E-2 l.16E-1 Cs 134 6.09E8 l.OOE9 Cs 137 8.99E8 8.60E8 Ba 140 2.20E7. l.93E4 La 140 2.80E-2 9.78E-3 Ce 141 l.17E4 5.82E3 Ce 144 l.48E6 4.65E5 Nd 147 5.93E3 4.80E3
- mrem/yr per µCi/m 3*
TABLE 3-17 DOSE AND DOSE RA TE R; VALUES - COW MEAT-CHILD m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 2.34E2 2.34E2 2.34E2 l.06E5 l.06E5 l.06E5 4.55E3 2.52E3 6.90E2 l.37E6 l.44E6 4.74E7 l.65E8 2.88E7 l.37E8 3.95E8 4.00E8 7.57E6 l.78E9 2.95E5 4.75E5 l.14E6 l.50E6 l.34E4 l.16E5 2.37E6 l.38E9 6.86E6 4.39E-2 2j15El l.93E-l 2.11E8 3.10E8 l.27E8 2.80E8 l.28E6 6.27E3 3.30E-3 8.64E2 2.55E3 7.91E4 2.57E5 3.72E2 2.64E3 II 61 LUNG GI-LLI 2.34E2 2.34E2 l.06E5 l.06E5 4.61E3 2.41E5 4.32E6 8.66E7 2.84E7 9.58E7 3.44E8 5.49E7 2.57E8 l.12E8 l.03E7 9.44E7 3.46E8 2.95E9 4.48E4 3.72E5 4.67E-2 l.11E8 5.39E6 l.01E8 5.39E6 l.15E4 l.11E7 2.73E2 7.26E6 l.21E8 7.61E6 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H3* 1.94E2 C 14* 2.81E5 5.62E4 Cr 51 Mn54 4.50E6 Fe 55 l.50E8 1.07E8 Fe 59 1.15E8 2.69E8 Co 58 8.05E6 Co 60 3.90E7 Zn65 l.59E8 5.52E8 Sr 89 l.40E8 Sr 90 5.42E9 Zr95 8.50E5 2.68E5 Nb95 2.37E6 l.32E6 Mo99 3.90E4 I 131 2.24E6 3.13E6 I 133 5.05E-2 8.57E-2 Cs 134 3.46E8 8.13E8 Cs 137 4.88E8 6.49E8 Ba 140 1.19E7 1.46E4 La 140 l.53E-2 7.5IE-3 Ce 141 6.19E3 4.14E3 Ce 144 7.87E5 3.26E5 Nd 147 3.16E3 3.44E3
- mrem/yr per µCi/m3*
TABLE3-18 DOSE AND DOSE RA TE Ri VALUES - COW MEAT - TEEN m2-mrem/yr µCi/sec TBODY THYROID KIDNEY l.94E2 l.94E2 l.94E2 5.62E4 5.62E4 5.62E4 2.93E3 l.62E3 6.39E2 \\ 8.93E5 1.34E6 2.49E7 l.04E8 l.86E7 8.80E7 2.57E8 3.53E8 4.01E6 l.34E9 l.84E5 3.94E5 7.24E5 l.28E6 7.43E3 8.92E4 l.68E6 9.15E8 5.40E6 2.6jE-2 l.20El l.50E-1 3.7 E8 2.58E8 2.26E8 2.21E8 7.68E5 4.95E3 2.00E-3 4.75E2 l.95E3 4.23E4 l.94E5 2.06E2 2.02E3 II 62 LUNG GI-LLI 1.94E2 l.94E2 5.62E4 5.62E4 4.16E3 4.90E5 9.24E6 6.77E7 4.62E7 8.47E7 6.36E8 1.11E8 5.09E8 2.34E8 l.67E7 1.52E8 6.19E8 5.63E9 6.98E4 6.20E5 6.48E-2 9.87E7 l.01E7 8.58E7 9.24E6 9.81E3 l.84E7 4.31E2 1.18E7 l.98E8 l.24E7 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H3* 3.25E2 C 14* 3.33E5 6.66E4 Cr 51 Mn54 5.90E6 Fe 55 1.85E8 1.28E8 Fe 59 l.44E8 3.39E8 Co 58 1,04E7 Co 60 5.03E7 Zn65 2.26E8 7.19E8 Sr 89 1.66E8 Sr 90 8.38E9 Zr95 1.06E6 3.40E5 Nb 95 3.04E6 l.69E6 Mo99 4.71E4 I 131 2.69E6 3.85E6 I 133 6.04E-2 1.05E-11 Cs 134 4.35E8 1.03E9 Cs 137 5.88E8 8.04E8 Ba 140 1.44E7 l.81E4 La140 1.86E-2 9.37E-3 Ce 141 7.38E3 4.99E3 Ce 144 9.33E5 3.90E5 Nd 147 3.59E3 4.15E3
- mrem/yr per µCi/m3*
TABLE3-19 DOSE AND DOSE RA TE R; VALUES - COW MEAT-ADULT m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 3.25E2 3.25E2 3.25E2 6.66E4 6.66E4 6.66E4 3.65E3 2.18E3 8.03E2 1.13E6 1.76E6 2.98E7 1.30E8 2.34E7 l.11E8 3.25E8 4.81E8 4.76E6 2.06E9 2.30E5 5.34E5 9.08E5 1.67E6 8.97E3 1.07E5 2.21E6 1.26E9 6.61E6 3.20E-2 1.54El l.83E-1 8.45E8 3.35E8 5.26E8 2.73E8 9.44E5 6.15E3 2.48E-3 5.66E2 2.32E3 5.01E4 2.31E5 2.48E2 2.42E3 \\ II 63 LUNG GI-LLI 3.25E2 3.25E2 6.66E4 6.66E4 4.84E3 9.17E5 l.81E7 7.14E7 7.34E7 9.46E7 l.13E9 2.12E8 9.45E8 4.53E8 2.66E7 2.42E8 l.08E9 1.03E10 l.09E5 1.02E6 9.44E-2 l.11E8 l.81E7 9.07E7 l.56E7 1.04E4 2.97E7 6.88E2 l.91E7 3.16E8 l.99E7 CY-NM-170-301 Revision 36 May 2017
NUCLIDE BONE LIVER H3* 4.0IE3 C 14* 3.50E6 7.0IE5 Cr 51 Mn54 6.65E8 Fe 55 7.63E8 4.05E8 Fe 59 3.97E8 6.42E8 Co 58 6.45E7 Co 60 3.78E8 Zn 65 8.12E8 2.16E9 Sr 89 3.59El0 Sr 90 l.24El2 Zr95 3.86E6 8.50E5 Nb 95 l.02E6 3.99E5 Mo99 7.70E6 I 131 7.16E7 7.20E7 I 13t, l.69E6 2.09E6 Cs 134 l.60El0 2.63El0 Cs 137 2.39El0 2.29El0 Ba 140 2.77E8 2.43E5 La 140 3.25E3 l.13E3 Ce 141 6.56E5 3.27E5 Ce 144 l.27E8 3.98E7 Nd 147 7.23E4 5.86E4
- mrem/yr per µCi/m3*
TABLE3-20 DOSE AND DOSE RA TE R; VALUES-VEGETATION-CHILD m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 4.0IE3 4.0IE3 4.0IE3 7.01E5 7.0IE5 7.0IE5 1.17E5 6.49E4 I l.77E4 l.77E8 l.86E8 l.25E8 3.20E8 l.97E8 1.12E9 l.35E9 l.36E9 l.03E9 3.15El 1 7.56E5 1.22E6 2.85E5 3.75E5 l.91E6 l.65E7 4.09E7 2.38El0 l.18E8 7.92E5 ~--89E8, I 3.49E6 5.55E9 8.15E9 3.38E9 7.46E9 l.62E7 7.90E4 3.83E2 4.85E4 1.43E5 6.78E6 2.21E7 4.54E3 3.22E4 II 64 LUNG GI-LLI 4.0IE3 4.01E3 7.0IE5 7.0IE5 l.18E5 6.20E6 5.58E8 2.29E8 7.50E7 l.86E8 6.69E8 3.76E8 2.10E9 3.80E8 l.39E9 l.67El0 8.86E8 7.37E8 6.37E6 6.41E6 8.44E5 2.93E9 l.42E8 2.68E9 l.43E8 l.45E5 l.40E8 3.16E7 4.08E8 1.04El0 9.28E7 CY-NM-170-301 Revision 36 May2017
NUCLIDE BONE LIVER Hf 2.59E3 C 14* 1.45E6 2.9IE5 Cr 51 Mn54 4.54E8 Fe 55 3.I0E8 2.20E8 Fe 59 1.79E8 4.18E8 Co 58 4.37E7 Co 60 2.49E8 Zn 65 4.24E8 1.47E9 Sr 89 1.5IE10 Sr 90 7.5IE11 Zr95 l.72E6 5.44E5 Nb95 4.80E5 2.66E5 Mo99 5.64E6 I 131 3.85E7 5.39E7 I 133 9.29E5 1.58E6 Cs 134 7.IOE9 1.67EIO Cs 137 1.0IE10 1.35EI0 Ba 140 l.38E8 1.69E5 La 140 l.8IE3 8.88E2 Ce 141 2.83E5 1.89E5 Ce 144 5.27E7 2.18E7 Nd 147 3.66E4 3.98E4 'mrem/yr per µCi/rii3 TABLE3-21 DOSE AND DOSE RA TE Ri VALUES - VEGETATION -TEEN m2-mrem/yr µCi/sec TBODY THYROID KIDNEY 2.59E3 2.59E3 2.59E3 2.9IE5 2.9IE5 2.9IE5 6.16E4 3.42E4 1.35E4 9.0IE7 l.36E8 5.13E7 1.6IE8 l.OIE8 5.60E8 6.86E8 9.4IE8 4.33E8 l.85Ell 3.74E5 7.99E5 1.46E5 2.58E5 1.08E6 1.29E7 2.89E7 1.57E10 9.28E7 4.80E5 2.20E8 2.76E6 7.75E9 5.3IE9 4.69E9 4.59E9 8.9IE6 5.74E4 2.36E2 2.17E4 8.89E4 2.83E6 1.30E7 2.38E3 2.34E4 II 65 LUNG GI-LLI 2.59E3 2.59E3 2.9IE5 2.9IE5 8.79E4 l.03E7 9.32E8 l.40E8 9.53E7 1.32E8 9.89E8 6.02E8 3.24E9 6.23E8 1.80E9 2.llElO l.26E9 l.14E9 1.0IE7 l.07E7 l.19E6 2.03E9 2.08E8 1.78E9 l.92E8 l.14E5 2.13E8 5.10E7 5.40E8 l.33El0 1.44E8 CY-NM-170-301 Revision 36 May2017
NUCLIDE BONE LIVER H3 2.26E3 C 14* 8.97E5 l.79E5 Cr51 Mn54 3.13E8 Fe 55 2.00E8 1.38E8 Fe 59 l.26E8 2.96E8 Co 58 3.08E7 Co 60 l.67E8 Zn 65 3.I7E8 l.01E9 Sr 89 9.96E9 Sr 90 6.05EI 1 Zr 95 1.18E6 3.77E5 Nb 95 3.55E5 l.98E5 Mo99 6.14E6 I 131 4.04E7 5.78E7 I 133 l.OOE6 l.74E6 Cs 134 4.67E9 l.llEIO Cs 137 6.36E9 8.70E9 Ba 140 1.29E8 l.61E5 La 140 l.98E3 9.97E2 Ce 141 1.97E5 1.33E5 Ce 144 3.29E7 1.38E7 Nd 147 3.36E4 3.88E4
- mrem/yr per µCi/m 3 TABLE3-22 DOSE AND DOSE RA TE R; VALUES - VEGETATION - ADULT m2-mrem/yr
µCi/sec T.BODY THYROID KIDNEY 2.26E3 2.26E3 2.26E3 l.79E5 l.79E5 l.79E5 4.64E4 2.77E4 l.02E4 5.97E7 9.31E7 3.22E7 1.13E8 6.90E7 3.69E8 4.56E8 6.75E8 2.86E8 l.48EI 1 2.55E5 5.92E5 l.06E5 l.95E5 1.17E6 1.39E7 3.31E7 l.90E10 9.91E7 5.30E5 2.56E8 3.03E6 9.08E9 3.59E9 5.70E9 2.95E9 8.42E6 5.49E4 2.63E2 l.51E4 6.19E4 1.77E6 8.16E6 2.32E3 2.27E4 II 66 LUNG GI-LLI 2.26E3 2.26E3 l.79E5 l.79E5 6.15E4 l.17E7 9.58E8 7.69E7 7.91E7 8.27E7 l.02E9 6.24E8 3.14E9 6.36E8 1.60E9 l.75El0 l.20E9 l.20E9 l.42E7 l.53E7 l.19E9 l.56J6 1.94 8 9.81E8 l.68E8 9.25E4 2.65E8 7.32E7 5.09E8 1.llElO l.86E8 CY-NM-170-301 Revision 36 May 2017
Pathway Fish Fish Shoreline Shoreline Inhalation TABLE3-23 PARAMETERS FOR THE EVALUATION OF DOSES TO REAL MEMBERS OF THE PUBLIC FROM GASEOUS AND LIQUID EFFLUENTS Parameters Value U (kg/yr) - adult 21 Daipj (mrem/pCi) Each Radionuclide U (hr/yr) - adult 67 - teen 67 Daipi Each Radionuclide (mrem/hr per pCi/m2) DFAiia Each Radionuclide II 67 Reference Reg. Guide 1.109 Table E-5 Reg. Guide 1.109 Table E-11 Reg. Guide 1.109 Assumed to be same as Adult Reg. Guide 1.109. Table E-6 Reg. Guide 1.109 Table E-7 CY-NM-170-301 Revision 36 May 2017 I
L TyQe ofSamQle Radioiodine and Particulates (air) Radioiodine and Particulates (air) Radioiodine and Particulates (air) Radioiodine and Particulates (air) Radioiodine and Particulates (air) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TJD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) Direct Radiation (TLD) TABLE 5.1 NINE MILE POINT NUCLEAR STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLING LOCATIONS
- ~ap Collection Site Location
{Env. Program No.} Location 1 Nine Mile Point Road 1.8 mi@92°E North (R-1) 2 Co. Rt. 29 & Lake Road (R-2) 1.1 mi@ 106° ESE 3 Co. Rt. 29 (R-3) 1.4 mi @ 134° SE 4 Village of Lycoming, NY (R-4) 1.8 mi@ 145° SE 5 Montario Point Road (R-5) 16.2 mi@ 42° NE 6 North Shoreline Area (75) 0.1 mi@354°N 7 North Shoreline Area (76) 0.1 mi@27°NNE 8 North Shoreline Area (77) 0.2 mi@ 37° NE 9 North Shoreline Area (23) 0.8 mi@ 74° ENE 10 JAF East Boundary (78) 1.0 mi@86°E l1 Rt. 29 (79) 1.2 mi@ 121° ESE 12 Rt. 29 (80) 1.5 mi @ 136° SE 13 Miner Road (81) 1.7 mi@ 160° SSE 14 Miner Road (82) 1.6 mi@ 180° S 15 Lakeview Road (83) 1.2 mi@ 203° SSW 16 Lakeview Road (84) 1.1 mi @ 225° SW 17 Site Meteorological Tower (7) 0.7 mi@ 244° WSW 18 Energy Information Center (18) 0.5 mi@266° W
- Map
= See Figures 5.1-1 and 5.1-2 II 68 CY-NM-170-301 Revision 36 May 2017
TABLE 5.1 NINE MILE POINT NUCLEAR STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLING LOCATIONS
- Map Collection Site Type of Sample Location (Env. Program No.)
Direct Radiation (TLD) 19 North Shoreline (85) Direct Radiation (TLD) 20 North Shoreline (86) Direct Radiation (TLD) 21 North Shoreline (87) Direct Radiation (1LD) 22 Hickory Grove (88) Direct Radiation (TLD) 23 Leavitt Road (89) Direct Radiation (TLD) 24 Rt. 104 (90) Direct Radiation (TLD) 25 Rt. 51A (91) Direct Radiation (TLD) 26 Maiden Lane Road (92) Direct Radiation (TLD) 27 Co. Rt. 53 (93) Direct Radiation (TLD) 28 Co. Rt. 1 (94) Direct Radiation (TLD) 29 Lake Shoreline (95) 1irect Radiation (TLD) 30 Phoenix, 1 Control (49) Direct Radiation (TLD) 31 S. W. Oswego, Control (14) Direct Radiation (TLD) 32 Scriba, NY (96) Direct Radiation (TLD) 33 Novelis, Rt. IA (58) Direct Radiation (TLD) 34 Lycoming, NY (97) Direct Radiation (TLD) 35 New Haven, NY (56) Direct Radiation (TLD) 36 W. Boundary, Bible Camp (15) Direct Radiation (TLD) 37 Lake Road (98) Surface Water 38 OSS Inlet Canal (NA) Surface Water 39 JAFNPP Inlet Canal (NA) (NA) = Not applicable
- Map = See Figures 5.1-1 and 5.1-2 II 69 Location 0.2 mi @ 290° WNW 0.1 mi@310° NW 0.1 mi@ 332° NNW 4.5 mi@97°E 4.3 mi @ 112° ESE 4.2 mi@ 135° SE 4.9 mi@ 157° SSE 4.5 mi@ 183° S 4.4 mi@ 206° SSW 4.4 mi @ 224° SW 3.7 mi@ 239° WSW 19.7 mi@ 168° SSE 12.5 mi @ 227° SW 3.7 mi@ 199° SSW 3.0 mi@222° SW 1.8 mi@ 145° SE 5.2 mi@ 124° SE 0.9 mi@ 239° WSW 1.2 mi @ 103° ESE 7.6 mi@ 236° SW 0.5 mi@ 71° ENE CY-NM-170-301 Revision 36 May 2017
Ty[!e of Sam[!le TABLE 5.1 (Cont'd) NINE MILE POINT NUCLEAR STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLING LOCATIONS
- Map Collection Site Location (Env. Program No.)
Location Shoreline Sediment 40 Sunset Bay Shoreline (NA) 1.2 mi@84° E Fish Fish Fish Milk Milk (CR) Food Product Food Product Food Product Food Product Food Product
- Map (NA)
CR 41 NMP Site Discharge Area (NA) 0.3 mi@315°NW (and/or) 42 NMP Site Discharge Area (NA) 0.6 mi @ 55° NE 43 Oswego Harbor Area (NA) 5.9 mi@237°WSW 64 Milk Location #55 8.8 mi@97°E 77 Milk Location 16.0 mi@ 190° S (Summerville) 48 Produce Location #6 *
- 1.9 mi@ 143° SE (Bergenstock) (NA) 49 Tduoo Location #1 *
- 1.6 mi@ 84° E
( uleton) (NA) 50 Produce Location #2 *
- 1.9 mi@ 101° E (Vitullo) (NA) 51 Produce Location #5 *
- 1.5 mi@ 116° ESE (C.S. Parkhurst) (NA) 52 Produce Location #3 *
- 1.5 mi@84°E (C. Narewski) (NA)
See Figures 5.1-1 and 5.1-2 Food Product Samples need not necessarily be collected from all listed locations. Collected samples will be of the highest calculated site average D/Q. Not applicable Control Result (location) II 70 CY-NM-170-301 Revision 36 May2017
TABLE 5.1 (Cont'd) NINE MILE POINT NUCLEAR STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLING LOCATIONS
- Map Collection Site Ty11e of Sam11Ie Location (Env. Program No.}
Location Food Product 53 Produce Location #4 *
- 1.7 mi@ 126° SE (P. Parkhurst) (NA)
Food Product (CR) 54' Produce Location #7*
- 15.I mi @222° SW (Mc Millen) (NA)
Food Product (CR) 55 Produce Location #8 *
- 12.5 mi @ 22?° SW (Denman) (NA)
Food Product 56 Produce Location #9 *
- 1.6 mi@ 171° S (O'Connor) (NA)
Food Product 57 Produce Location #10*
- 2.3 mi@ 124° SE (C. Lawton) (NA)
Food Product 58 Produce Location #11 *
- 2.0 mi @ 112° ESE (C. R. Parkhurst) (NA)
Food Product 59 Produce Location #12 *
- 2.0 mi@ 110° ESE (Barton) (NA)
Food Product (CR) 60 I Produce Location # 13 *
- 15.4 mi@222° sr (Flack) (NA)
Food Product 61 Produce Location #14 *
- 1.9 mi@97°E (Koeneke) (NA)
Food Product 62 Produce Location #15 *
- 1.6 mi @ 139° SE (Whaley) (NA)
Food Product 63 Produce Location # 16 *
- 1.2 mi @ 209° SSW (Murray) (NA)
Food Product 67 Produce Location #17** 1.7mi@98°E (Battles) Food Product 68 Produce Location # 18 *
- 1.5 mi@84°E (Kronenbitter)
Food Product 69 Produce Location #119*
- 1.4 mi@ 132° SE (O'Connor)
See Figures 5.1-1 and 5.1-2
- Map Food Product Samples need not necessarily be collected from all listed locations. Collected samples will be of the highest calculated site average D/Q.
(NA) CR Not applicable = Control Result (location) II 71 CY-NM-170-301 Revision 36 May 2017
-..J N ~ (l) p:, < '-< ~: NO o::i ...... w --..i 0\\ n I z ~ I...... --..i 0 I w 0...... Site Map 1 Mile Radius SW(L) FIGURE 5.1-1 NINE MILE POINT ON-SITE MAP D,. ENVIRONMENTAL SAMPLE LOCATIONS 26.25' 3.75' Lake Ontario ESECF) 123.75' SECG) 2 146.25' gJ t SSE(H) 0 t) ~"'~ 0,$' ",{; 3 .1 0 Scale (Miles) 1
FIGURE 5.1-2 NINE MILE POINT OFF-SITE MAP D ENVIRONMENTAL SAMPLE LOCATIONS Scale(Miles) 0 2 3 4 5 Lake Ontario NMP U1 Rx N
FIGURE 5.1-2a NINE MILE POINT OFF-SITE MAP . D. ENVIRONMENTAL SAMPLE LOCATIONS \\ \\ L- \\ 8 OSWEGO COUNTY ONONDAGA COUNTY SCALE (MILES) L:-:-+,:d b;..,,1\\d j
-..J .j::,. n ~z ~ ~ s:: ~ II-'* I '< ~- ~ Noo o::l w ...... l;J 0 ......:i O'\\ - FIGURE 5.1.3-1 Sile Boundaries .1 NIFUrlt2 ~Llld E*dllJIIII., I J.. *I I.,c! I
- I L, c,!
L ***I o Scale(Miles) 1
- ~
- a.a,.,.
JAF!ipd
- c.llSIII
.'~ II ..,1* L.yGClllll'l!I Lake Ontarto J i J,JI,,,...... 11 11
- ~
N Note: NaUonaJ Grtd retsina ownership In certain transmsslon line and switchyerd facilitiee within th& exclusion area. boundary. Aoo8Bs end usage ere oomrolled by Nm Mlle Point Nucm statiGRrl.LC by agreement.
APPENDIX A LIQUID DOSE FACTOR DERIVATION II 75 CY-NM-170-301 Revision 36 May 2017
Appendix A Liquid Effluent Dose Factor Derivation, Aiat Aiat (mrem/hr per µCi/ml) which embodies the dose conversion factors, pathway transfer factors (e.g., bioaccumulation factors), pathway usage factors, and dilution factors for the points of pathway origin takes into account the dose from ingestion of fish and drinking water and the sediment. The total body and organ dose conversion factors for each radionuclide will be used from Table E-11 of Regulatory Guide 1.109. To expedite time, the dose is calculated for a maximum individual instead of each age group. The maximum individual dose factor is a composite of the highest dose factor Aiat of each nuclide i age group a, and organ t, hence A1*1* It should be noted that the fish ingestion pathway is the most significant pathway for dose from liquid effluents. The water consumption pathway is included for consistency with NUREG 0133. The equation for calculating dose contributions given in section 1.3 requires the use of the composite dose factor Air for each nuclide, i. The dose factor equation for a fresh water site is: Where: Ko Ur Us (BF)i (DFL)iat (DFS)i Is the dose factor for nuclide i, age group a, total body or organ t, for all appropriate pathways, (mrem/hr per µCi/ml). Is the unit conversion factor, 1. ltE5=1E6pCi/µCi x 1E3 ml/kg-:- 8760 hr/yr. Water consumption (I/yr); from Table E-5 of Reg. Guide 1.109. Fish consumption (Kg/yr); from Table E-5 of Reg. Guide 1.109. Sediment Shoreline Usage (hr/yr); from Table E-5 of Reg. Guide 1.109. Bioaccumulation factor for nuclide, i, in fish, (pCi/kg per pCi/1), from Table A-1 of Reg. Guide 1.109. Dose conversion factor for age, nuclide, i, group a, total body or organ t, (mrem/pCi); from Table E-11 of Reg. Guide 1.109. Dose conversion factor for nuclide i and total body, from standing on contaminated ground (mem/hr per pCi/m2); from Table E-6 of Reg. Guide 1.109. Dilution factor from the near field area within one-quarter mile of the release point to the potable water intake for the adult water consumption. This is the Metropolitan Water Board, Onondaga County intake structure located west of the City of Oswego; (unitless). II 76 CY-NM-170-301 Revision 36 May 2017
Appendix A (Cont'd) 69.3 w Example Calculation Dilution factor from the near field area within one quarter mile of the release point to the shoreline deposit (taken at the same point where we take environmental samples 1.5 miles; unitless). conversion factor.693 x 100, 100 = Kc (L/kg-hr) *40*24 hr/day/.693 in L/m 2 -d, and Kc = transfer coefficient from water to sediment in L/kg per hour. Average transit time required for each nuclide to reach the point of exposure for internal dose, it is the total time elapsed from release of the nuclides to either ingestion for water (w) and fish (f) or shoreline deposit (s), (hr). Length of time the sediment is exposed to the contaminate_d water, nominally 15 yrs (approximate midpoint of facility operating life), (hrs). decay constant for nuclide i (hr"1). Shore width factor (unitless) from Table A-2 of Reg. Guide 1.109. For I-131 Thyroid Dose Factor for an Adult fror a Radwaste liquid effluents release: (DFS)i = 2.80E-9 mrem/hr per pCi/m2 (DFL)i.t = l.95E-3 mrem/pCi tpw = 30 hrs. (w = water) BFi = 15 pCi/Kg per pCi/L tpf = 24 hrs. (f= fish) Ur = 21 Kg/yr th = l.314E5 hrs. (5.48E3 days) Dw = 40 unitless Uw = 730 L/yr Ds = 12 unitless Ko = 1.14E5 (QCi/b!,Ci)(ml/kg)
- u.
= 12 hr/yr (hr/yr) w = 0.3 Ai = 3.6IE-3hr"1 tps =5.5 hrs (s = Shoreline Sediment) These values will yield an Aiat Factor of 6. 79E4 mrem-ml per µCi-hr as listed in Table 2-4. It should be noted that only a limited number of nuclides are listed on Tables 2-1 to 2-8. These are the most common nuclides encountered in effluents. If a nuclide is detected for which a factor is not listed, then it will be calculated and included in a revision to the ODCM. In addition, not all dose factors are used for the dose calculations. A maximum individual is used, which is a composite of the maximum dose factor of each age group for each organ as reflected in the applicable chemistry procedures. II 77 CY-NM-170-301 Revision 36 May 2017
APPENDIXB PLUME SHINE oosk FACTOR DERIVATION II 78 CY-NM-170-301 Revision 36 May 2017
APPENDIXB For elevated releases the plume shine dose factors for gamma air (Bi) and whole body (Vi), are calculated using the finite plume model with an elevation above ground equal to the stack height. To calculate the plume shine factor for gamma whole body doses, the gamma air dose factor is adjusted for the attenuation of tissue, and the ratio of mass absorption coefficients between tissue and air. The equations are as follows: Gamma Air Bi = :Es Kg~E I1 Where: K' = conversion factor (see Rev. below for actual value). µ. = mass absorption coefficient (cm2/g; air for Bi, tissue for Vi) E Energy of gamma ray per disintegration (Mev) Vs = average wind speed for each stability class (s), mis R = downwind distance (site boundary, m) e = sector width (radians) s = subscript for stability class Is = I function= 11 + kI2 for each stability class. ( unitless, see Regulatory Guide 1.109) k2 = Fraction of the attenuated energy that is I actually absorbed in air (see Regulatory Guide 1.109, see below for equation) Whole Body - µ.td vi 1.1 lSFBie Where: td = tissue depth (g/cm2) Sp shielding factor from structures (unitless) 1.11 Ratio of mass absorption coefficients between tissue and air. Where all other parameters are defined above. 1K = conversion factor [3.7 ElO dis] 1.6 E-6 gg] Ci-sec Mev= 0.46 [ 1293 g 1 [ 100.§:g ] m g-rad Where: µ mass attenuation coefficient (cm2/g; air for Bi, tissue for Vi) µ. defined above II 79 CY-NM-170-301 Revision 36 May 2017
APPENDIX B (Cont'd) There are seven stability classes, A thru F. The percentage of the year that each stability class occurs is taken from the U-2 FSAR. From this data, a plume shine dose factor is calculated for each stability class and each nuclide, multiplied by its respective fraction and then summed. The wind speeds corresponding to each stability class are, also, taken from the U-2 FSAR. To confirm the accuracy of these values, an average of the 12 month wind speeds for 1985, 1986, 1987 and 1988 was compared to the average of the FSAR values. The average wind speed of the actual data is equal to 6.78 mis, which compared favorably to the FSAR average wind speed equal to 6.77 mis. The average gamma energies were calculated using a weighted average of all gamma energies emitted from the nuclide. These energies were taken from the handbook "Radioactive Decay Data Tables", David C. Kocher. The mass absorption (µa) and attenuation(µ) coefficients were calculated by multiplying the mass . absorption (µalµ) and mass attenuation (µIp) coefficients given in the Radiation Health Handbook by the air density equal to 1.293 E-3 glee or the tissue density of 1 glee where applicable. The tissue depth is 5glcm2 for the whole body. The downwind distance is the site boundary. II 80 CY-NM-170-301 Revision 36 May 2017
APPENDIX B (Cont'd) SAMPLE CALCULATION Ex. Kr-89 F STABILITY CLASS ONLY - Gamma Air -DATA E = 2.22MeV µa = 2.943 E-3m-1 µ = 5.5064E-3m-1 e = o.39 k = 1!:J!a =.871 µa R = 644m K = 0.46 VF = 5.55 m/sec az = 19m....... vertical plume spread taken from "Introduction to Nuclear Engineering", John R. LaMarsh -I Function Ucr2 = 0.06 11 = 0.33 Ii = 0.45 I = 11 + kl2 = 0.33 + (0.871) (0.45) = 0.72 dis. Bi = 0.46 Ci-sec CirY..) (g/m3) (ergs) (5.55 m/s) (.39) (644m) I (g-rad) = 1.55(-6) rad/s (3600 s/hr) (24 h/d) (365 d/y) (1E3mrad/rad) = = = Ci/s (1E6µCi) 2.76(-2) mrad/yr µCi/sec Ci 1.11(.7) [2.76(-2) mrad/yr] µCi/sec 1.89(-2) mrad/yr µCi/sec -(.0253 cm2/g)(5g/cm2) [e ] NOTE: The above calculation is for the F stability class only. For Table 3-2 and procedure values, a weighted fraction of each stability class was used to determine the Bi and Vi values. II 81 CY-NM-170-301 Revision 36 May 2017
APPENDIXC ORGAN DOSE PARAMETERS FORIIODINE 131 and 133, PARTICULATES AND TRITIUM II 82 CY-NM-170-301 Revision 36 May 2017
APPENDIXC ORGAN DOSE PARAMETERS FOR IODINE - 131 AND - 133, PARTICULATES AND TRITIUM This appendix contains the methodology which was used to calculate the organ dose factors for 1-131, 1-133, particulates, and tritium. The dose factor, R;, was calculated using the methodology outlined in NUREG-0133. The radioiodine and particulate ODCM Part I (Control DLCO 3.6.15) is applicable to the location in the unrestricted area where the combination of existing pathways and receptor age groups indicates the maximum potential exposure occurs, i.e., the critical receptor. Washout was calculated and determined to be negligible. Ri values have been calculated for the adult, teen, child and infant age groups for all pathways. However, for dose compliance calculations, a maximum individual is assumed that is a composite of highest dose factor of each age group for each organ and pathway. The methodology used to calculate these values follows: C. l. Inhalation Pathway R;(I) where: R;(I) K' (BR). (DFA)ija K'(BR).(DF A)ija dose factor for each identified radionuclide i of the organ of interest (units= mrem/yr per µCi/m3); a constant of unit conversion, IE6 pCi/µCi Breathing rate of the receptor of age group a, (units= m3/yr); The inhalation dose factor for nuclide i, organ j and age group a, and organ t (units= mrem/pCi). The breathing rates (BR). for the various age groups, as given in Table E-5 of Regulatory Guide 1.109 Revision 1, are tabulated below. Age Group (a) Infant Child Teen Adult Breathing Rate (m3 /yr) 1400 3700 8000 8000 Inhalation dose factors (DF A)ija for the various age groups are given in Tables E-7 through E-10 of Regulatory Guide 1.109 Revision 1. II 83 CY-NM-170-301 Revision 36 May 2017
APPENDIX C (Cont'd) C.2 Ground Plane Pathway Where: Ri(G) K' K" "-i t (DFG)i Dose factor for the ground plane pathway for each identified radionuclide i for the organ of interest (units= m2-mrem/yr per µCi/sec) A constant of unit conversion, 1E6 pCi/µCi A constant of unit conversion, 8760 hr/year The radiological decay constant for radionuclide i, (units= sec-1) The exposure time, sec, 4.73E8 sec (15 years) The ground plane dose conversion factor for radionuclide i; (units= mrem/hr per pCi/m2) SF r The shielding factor (dimensionless) I A shielding actor of0.7 is discussed in Table E-15 of Regulatory Guide 1.109 Revision 1. A tabulation ofDFGi values is presented in Table E-6 ofRegulatory Guide 1.109 Revision 1. II 84 CY-NM-170-301 Revision 36 May 2017
C.3 Where: K' . Qr r (DFL\\a1 APPENDIX C (Cont'd) Grass-(Cow or Goat)-Milk Pathway = Dose factor for the cow milk or goat milk pathway, for each identified radionuclide i for the organ of interest, (units== m 2 -mrem/yr per µCi/sec) A constant of unit conversion, 1E6 pCi/µCi The cow's or goat's feed consumption rate, (units= kg/day-wet weight) The receptor's milk consumption rate for age group a, (units== liters/yr) The agricultural productivity by unit area of pasture feed grass, (units== kg/m2) The agricultural productivity by unit area of stored feed, (units = kg/m2) The stable element transfer coefficients, (units== pCi/liter per pCi/day) Fraction of deposited activity retained on cow's feer grass The ingestion dose factor for nuclide i, age group a, and total body or organ t (units== mrem/pCi) The radiological decay constant for radionuclide i, (units==sec -1) The decay constant for removal of activity on leaf and plant surfaces by weathering equal to 5.73E-7 sec -I (corresponding to a 14 day half-life) The transport time from pasture to cow or goat, to milk, to receptor, (units= sec) The transport time from pasture, to harvest, to cow or goat, to milk, to receptor (units== sec) Fraction of the year that the cow or goat is on pasture (dimensionless) Fraction of the cow feed that is pasture grass while the cow is on pasture (dimensionless) II 85 CY-NM-170-301 Revision 36 May 2017
APPENDIX C (Cont'd) Milk cattle and goats are considered to be fed from two potential sources, pasture grass and stored feeds. Following the development in Regulatory Guide 1.109 Revision 1, the value offs is considered unity in lieu of site specific information. The value of fv is 0.5 based on 6 month grazing period. This value for f P was obtained from the environmental group. Table C-1 contains the appropriate values and their source in Regulatory Guide 1.109 Revision 1. 1 The concentration of tritium in milk is based on the airborne concentration rather than the deposition. Therefore, the RT(C) is based on X/Q: Where: K"' H 0.75 0.5 = Dose factor for the cow or goat milk pathway for tritium for the organ of interest, (units = mrem/yr per µCi/m 3) A constant of unit conversion, 1E3 g/kg Absolute humidity of the atmosphere, (units= g/m3) The fraction of total feed that is water The ratio of the specific activi1t7 of the feed grass water to the atmospheric water I Other values are given previously. A site specific value ofH equal to 6.14 g/m3 is used. This value was obtained from the environmental group using actual site data. II 86 CY-NM-170-301 Revision 36 May 2017
APPENDIX C (Cont'd) C.4 Grass-Cow-Meat Pathway Ri(M) Dose factor for the meat ingestion pathway for radionuclide i for any organ of interest, (units= m2-mrem/yr per µCi/sec) The stable element transfer coefficients, (units= pCi/kg per pCi/day) The receptor's meat consumption rate for age group a, (units= kg/year) The transport time from harvest, to cow, to receptor, (units = sec) The transport time from pasture, to cow, to receptor, (units = sec) All other terms remain the same as defined for the milk pathway. Table C-2 contains the values which were used in calculating Ri(M). The concentration of tritium in meat is based on airborne concentration rather than deposition. Therefore, the RT(M) is based on X/Q. Where: Dose factor for the meat ingestion pathway for tritium for any organ of interest, (units= mrem/yr per µCi/m 3) All other terms are defined above. II 87 CY-NM-170-301 Revision 36 May 2017
APPENDIX C (Cont'd) C.5 Vegetation Pathway Where: The integrated concentration in vegetation consumed by man follows the expression developed for milk. Man is considered to consume two types of vegetation (fresh and stored) that differ only in the time period between harvest and consumption, therefore: Dose factor for vegetable pathway for radionuclide i for the organ of interest, (units= m2-mrem/yr per ~LCi/sec) The consumption rate of fresh leafy vegetation by the receptor in age group a, (units= kg/yr) The consumption rate of stored vegetation by the receptor in age group a (units = kg/yr) The fraction of the annual intake of fresh leafy vegetation grown locally The fraction of the annual intake of stored vegetation grown locally The average time between harvest of leafy vegetation and its consumption, (units = sec) I I The average time between harvest of stored vegetation and its consumption, (units= sec) The vegetation areal P density, (units= kg/m 2 ) All other factors have been defined previously. Table C-3 presents the appropriate parameter values and their source in Regulatory Guide 1.109 Revision 1. In lieu of site-specific data, values for FL and Fg of, 1.0 and 0.76, respectively, were used in the calculation. These values were obtained from Table E-15 of Regulatory Guide 1.109 Revision 1. The concentration of tritium in vegetation is based on the airborne concentration rather than the deposition. Therefore, the RT(V) is based on X/Q: Where: dose factor for the vegetable pathway for tritium for any organ of interest, (units= mrem/yr per µCi/m3). All other terms are defined in preceeding sections. II 88 CY-NM-170-301 Revision 36 May 2017
Parameter Qr(kg/day) r (DFL\\a (mrem/pCi) Fm (pCi/liter per pCi/day) Ys (kg/m2) Yv (kg/m2) th (seconds) tr (seconds) Uap (liters/yr) TABLE C-1 Parameters for Grass-(Cow or Goat)-Milk Pathways Value 50 (cow) 6 (goat) 1.0 (radioiodines) 0.2 (particulates) Each radionuclide Each stable element 2.0 0.7 7.78 x 10 6 (90 days)
- 1. 73 x 10 5 (2 days) 330 infant 330 child 400 teen 310 adult II 89 Reference (Reg. Guide 1.109 Rev. 1)
Table E-3 Table E-3 Table E-15 Table E-15 Tables E-11 to E-14 Table E-1 ( cow) Table E-2 (goat) Table E-15 Table E-15 Table E-15 Table E-15 Table E-5 Table E-5 Table E-5 Table E-5 CY-NM-170-301 Revision 36 May2017
L Parameter r Fr (pCi/Kg per pCi/day) Uap (Kg/yr) (DFL)ija (mrem/pCi) Yp (kg/m2) Ys (kg/m 2 ) t11 (seconds) tr (seconds) Qr (kg/day) TABLEC-2 Parameters for the Grass-Cow-Meat Pathway Value 1.0 (radioiodines) 0.2 (particulates) Each stable element 0 infant 41 child 65 teen 110 adult Each radionuclide 0.7 2.0 7.78E6 (90 days) l.73E6 (20 days) soJ II 90 Reference (Reg. Guide 1.109 Rev. 1) Table E-15 Table E-15 Table E-1 Table E-5 Table E-5 Table E-5 Table E-5 Tables E-11 to E-14 Table E-15 Table E-15 Table E-15 Table E-15 Table E-3 CY-NM-170-301 Revision 36 May 2017
Parameter r ( dimensionless) (DFL)ija (mrem/pCi) UL)a (kg/yr) - infant - child - teen - adult U 8)a (kg/yr) - infant - child k (seconds) th (seconds) - teen - adult TABLEC-3 Parameters for the Vegetable Pathway Value 1.0 (radioiodines) 0.2 (particulates) Each radionuclide 0 26 42 64 0 520 630 520 8.6E4 (1 day) 5.18E6 (60 days) 2.0 II 91 Reference (Reg. Guide 1.109 Rev. 1) Table E-1 Table E-1 I Tables E-11 to E-14
- Table E-5 Table E-5 Table E-5 Table E-5 Table E-5 Table E-5 Table E-5 Table E-5 Table E-15 Table E-15 Table E-15 CY-NM-170-301 Revision 36 May 2017
APPENDIXD DIAGRAMS OF RADIOACTIVE LIQUID AND GASEOUS EFFLUENT TREATMENT SYSTEMS AND I MONITORING SYSTEMS II 92 CY-NM-170-301
- Revision 36 May2017
\\~ tl:tfllWLllOCl ~ I i l ~ i i i 2 ~ M I i f ~ f I g I I * ~ 11 i ~ l l r I § ~ 3 > ~ g. ~ ~
- RC
- IC.,... '" '*
- I..
CIXllCmm C C~ C:IC Clff.,*US. ..,..., (lf'IC etc arw cr1 , nc tic " "'...
- 111 m " " " "
HUMtC:UY 11 lt'IC NC m " ,11,MC. Jl!ilC,HC .,.,~, l L~C "" " "' tAtl1!.fll: "'l'laC,1e ,c "" "' "'* rem,~ """,1 ...Ct1tl(>>I. M " liWP!UI.JII' Tl, TIC " '" WIWIAIIC~. ,~ l(.IIC\\/IJII WIIC.WIC '"... ,ag:am, 111:c.~.,..,., ..:U,Jl"'tLUI 1l1¥t,(.. o.... Ill vrn~ Sill 1,I t, I DOIIJT? M OU M1'1t)C[N H,..,.. 0 INST[lUMENT SYM~Ql,S CONTROL VAbVE OPERAT[ON [I;'~ k.O.*~OT!llt Cl'll.*nwc r,i OCI ~.o.**in ~1110,, ~u. tLO..+iYWlllCrlSl()l,ll7~11. P,D.of'0"4ROl'U. ~ ~ Ol~OHllillllfO ~~ f:M:~tcS"Jr:?c-ifi:u c£1ctl i'lfU:E~~l!~!.I' ~~ CIN'tlAACH OPlAAJ[ll 1i111tt,am1avi ~ $(1.[JCl!DUU[ n I ~ ~ ~.i:~~--::STEM s:: (1) ~ I en - o* -..J N 0
- s I
0 w v.) 0 FSM 1"1 .....:i 0\\ - A* 13S01 r IICM:lfl:K-\\NIJAI.CCtlfllf>>.. U:Ol11Ml.1100HI OCUT Al Nll/UI 01/'(IIWll! '? ll[l"()TC fWl!JliL CCNU\\tl... ILOC.U.J I 1Vlt[ll ~ e i ' I l ~ I i I ~ X on 0-11,.. n " m " LI ti ,011,m ,,~. ~rnri::;::~:=.~rn I FLOW DEVICES ~l~Pllel'IG. LDll[\\.DWl"JWltt l*I ~!t.~l;:"ot':it, ~C~fntCCIII. Lehi Wt-INT t<Jlr~r -eJ PILOJ T(f:H PUMPS AND FANS ~u,murucAL,IIM' ~ ll!CIPll!lCUiflOIPlnP\\W CIM'IILS11111 @fAHCllill.WUI 0 ROfA~fU),lfP\\Jk9 &1.0"'11,~nrcq &LIW<I i ~ ~ i I ! ! i ~ d *
- CA
[A. CA tll tlP*~..., ,.,~ L u
- ~..
,a r*..,_ lA y,.. T* 1... P[P!NG SYMBOLS -+<;;'"" STIUo/wta nlUII y __:fr_ stl'MATCl'I 0 t,,CwYfilf ? Ci'UDIWII -D- --{ ~r.,.., -~ ICIV.:-.tOC" --1 11[1.DmCN' "1:*JUcw.Ne(lt !l::ll nlH:,111'00l.1!tCt - lL(CIRICHCum 0-- sra*~ lfCIULt Cl\\,tlJll'j',!ff VALVE SYMBOLS Dll&.L -(><j-C,UC -C CL1l;( --l>1-tJ<tC!IJf.UM.1.Tl\\llWOT\\'*[I t.l'f(M(O( lfll' D((I( --f"u..1-- BUT1[!n't lCU!.1£1 -;-1-- IIUntcnT WOil f t'1 si.:£n OR Rn1tr ~ Tl9'1['s.llY ~~ ,001111.-v ~ Jl'tAICOC:IC.'1.U:. Qlilill.J.V"'-\\t -{9-- tlf11C""1'.lllfCOCl( + ,o.,n.,mr -COOi' -~ FLOW a,(CW: 'fM.l't -i.... SllllDtRSl'I( LINE SYMBOLS PAJMAA't' n.W UC1l!(11.R'/fLDW Mfl'IUMtl(I',uiet~AI~ Ml~JCQl,ltllCl,,111" (MSflWHlNTR.ECf.ltllllDS l'llf~t CAl'fl.LMT JUBI~ C(NICCCIIO>t tMftlNO -n.C\\'DJUCT[OII M:&TULII,££ -<])- SALL JCINT -{J)- Dl~tvW.M 5'1\\L SPECIAL NQJL --lXl-VENTllAf!ON DAMPERS ..co!illl.O.L...Ylll.YL DE s TQNA T ION VAL VE POSITIONS CONTROL VALVE OPEAATIQJ:L_ EXPANSION JOINTS -'"\\..,- -<>"\\.,.... -a- -:i- ,u*etl);J' l\\[Vlf;l(H:)I[ l!ILLC~JOINI ~ll'JOl,.f FIGURED-0 PIPING INSTRUMENT AND EOUIPMENT SYMBOLS NINE MILE POINf UNIT 1 OFFSITE DOSE CALC. MANUAL t-17 FIGURE I
- I REV.J (lqB51
'**----*--~--... - ___.. __ _ I I I I I I I I l I I I .l I I I I I
tl I N n ?O ~ ~ (1) < I ~ r;;*...... 5* -..J N 0
- i I
0 w ...... t,.) 0 -..J °' MAIN CONDENSER AIR REMOVAL AND OFF GAS SYSTEM c.i.uno~ 11,.,.. ~
- r... a.;.,.
D02~1! E..,,.,....n.......... _""" I FIGURED-2 STM PACKING, EXHAUSTER, AND RECOMilINER NINE MILE POINT UNIT 1 OFFSITE DOSE CALC. MANUAL XH
REACTOR BUILDING VENT!LA TION SYSTEM t) I l,J I L~-*"'-~------ VI*63 fUX'.11 n, Ill' J,<11 CIM <N<N:J"" I fJN UN UM aN FIGURED-3 REACTOR BUILDING VENT SYSTEM NINE MILE POINT UNIT 1 OFFSITE DOSE CALC. MANUAL
("') ~ ~ ~ I ~ ;;;* - 5* -..J N 0
- i I
0 w ...... v.) 0 -...,l 0\\ - WASTE DISPOSAL BUILDING VENTILATION SYSTEM --*~*-! i -fr* ~ I: latfta.1111 ~=* l!.NCftl J.i~f~lE!it. t11tt~~,:,r,r~ T*d!:111:HfJt ... _,~ l'IIM' "II °"'r~" 0~:r: 0 I I I I I l-----.. -e. e-.. ---...... 1 CJ'AIIIIJG,la.I
- ..................................... *........................................... 1------*----s f~_tJ 1~,i.
~J't"' ndW~~ r-., r.w *n
- . -------------------------------------r-*---**----~
f~_tJ '~:1 Jflff~; ~un,.,. *u ITC.11MT,f!001tllt FIGURED-4 WASTE DISPOSAL BUILDING VENT SYSTEM NINE MILE POINT UNIT 1 OFFSITE DOSE CALC. MANUAL
STACK - PLAN AND. ELEVATION ~..... 0 1:LE.VATION G'RA?HIC FlGURED-5 NMP-1 STACK KlAGARA MOHA V.'K POWER CORPORA TIO!',; N1NE 1vfILE POINT UNIT 1 OFFSITE DOSE CALC. MANUAL D-5 llOCJ( l:~.?17-c:,- """------'-""-l ~!...£VATION LOOO:l"-IC. NORTl-4 CY-NM-170-301 Revision 36 May 2017
OFF GAS BUILDING VENTILATION SYSTEM ) rni~**u d
- 1~,,
h**etl&t. C~II ti I O'\\ (J ~ ~ ~ ~ r;;* I..... o* -..J N 0 0
- s I w
.... w 0 -..J 0\\..... IHUH HllCOIU(... Ill UM mow
- w1m,
.,~ h,U1'*r I I I ~---4r-L0
- *************************---~
I I !1 r----------L
- t---~
i ~ l I I ,_ _____ 4-___..L,, FIGURED-6 OFFGAS BUILDING VENT SYSTEM NINE 'MILE POINT UNIT 1 OFFSITE DOSE CALC. MANUAL
This Page and Figure Deleted. D-7 CY-NM-170-301 Revision 36 May 2017
112-31 D-8 RA GEMS AAGEMS Auxiliary Sample ~ ---,~--+-- Point Rellrn
- 112-13,1
- I 112-52 Flourt [). B Staci< Sanipkl and Sample Return NIAGARA MO-IAWK POWER CORPORATION NINE MILE POINT
- UNIT 1
.
- OFFSITE DOSE CAlC. MANUAL CY-NM-170-301 Revision 36 May2017
This Page and Figure Deleted. D-9 CY-NM-170-301 Revision 36 May 2017
This Page and Figure Deleted. D-10 CY-NM-170-301 Revision 36 May 2017
112-i2 112-1:Je 11:2-155 112-U2 l!J 112-12 112-&c 112-M L!J l.!.I PSl 112-152 112-L!I e2 112-ts.4 112-137 112-1-41 L!J 112-21 Fl3 Fi ure 0- 1 OGESMS Schematic NIAGARA MOHAWK POWER CORPOR.ATION NINE MILE POINT - UNIT 1 OFFSITE DOSE CALC. MANUAL.
ATTACHMENT 13 Page 1 of 1 Unit 1 Unit2 X Reporting Period: January - December 2017 Off-Site Dose Calculation Manual (ODCM) There was no revision to the Off-Site Dose Calculation Manual for 2017. _}}