- UNITED STATES NUCLEAR REGULATORY COMMISSION Mr. Harold W. Keiser Executive Vice President -
Nuclear Business Unit Public Service Electric & Gas Company Post Office Box 236 Hancocks Bridge, NJ 08038 WASHINGTON, D.C. 20555-0001 February 4, 1998
SUBJECT:
COMPLETION OF LICENSING ACTION FOR GENERIC LETTER 96-01, "TESTING OF SAFETY-RELATED LOGIC CIRCUITS," DATED JANUARY 10, 1996, SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 (TAC NOS. M94726 AND M94727)
Dear Mr. Keiser:
On January 10, 1996, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 96-01, "Testing of Safety-Related Logic Circuits," to all holders of operating licenses or construction permits. The NRC issued GL 96-01 for three principal reasons:
- 1.
Notify addressees about problems with testing of safety-related logic circuits;
- 2.
Request that all addressees implement the actions described within the generic letter; and
- 3.
Require that all addressees submit to the NRC a written response regarding implementation of the requested actions.
In GL 96-01, the NRC staff specifically requested that licensees take the following actions:
- 1.
Compare electrical schematics and logic diagrams for the reactor protection system, emergency diesel generator load shedding and sequencing, and actuation logic for the engineered safety feature systems against plant surveillance test procedures to ensure that all portions of the logic circuitry, including the parallel logic, interlocks, bypasses, and inhibit circuits, are adequately covered in the surveillance procedures to fulfill the technical specification requirements. This review should also include relay contacts, control switches, and other relevant electrical components within these systems, utilized in the logic circuits performing a safety function; and
- 2.
Modify the surveillance procedures as necessary for complete testing to comply with the technical specifications. Additionally, the licensee may request an amendment to the technical specifications if relief from certain testing requirements can be justified.
r
-~---*--- - -~-~
9802240084 980204 II PDR ADOCK 05000272 P
PDR J
- lllll/l lllll lllll llllll lllllllllllll/111 '
'(
5 8
1 E
Mr. Harold Furthermore, the NRC staff required that addressees prepare and submit the following:
- 1.
A written response indicating whether or not the licensee would implement the actions requested above or propose an alternative action;
- 2.
A schedule for completing the requested actions or proposed alternative; and
- 3.
A response confirming completion of the requested actions.
In response to GL 96-01, you provided letters dated April 16, 1996, and January 15, 1998, for the Salem Nuclear Generating Station. These submittals provided both the information requested and the responses required by GL 96-01; therefore TAC Nos. M94726 and M94727 are closed.
If you have any questions regarding this matter, please contact Mr. Patrick Milano at 301-415-1457.
Docket Nos. 50-272 and 50-311 cc: See next page Sincerely, Patrick D. Milano, Senior Project Manager Project Directorate 1-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Mr. Harold Furthermore, the NRC staff required that addressees prepare and submit the following:
- 1.
A written response indicating whether or not the licensee would implement the actions requested above or propose an alternative action;
- 2.
A schedule for completing the requested actions or proposed alternative; and
- 3.
A response confirming completion of the requested actions.
In response to GL 96-01, you provided letters dated April 16, 1996, and January 15, 1998, for the Salem Nuclear Generating Station. These submittals provided both the information requested and the responses required by GL 96-01; therefore TAC Nos. M94726 and M94727 are closed.
If you have any questions regarding this matter, please contact Mr. Patrick Milano at 301-415-1457.
Docket Nos. 50-272 and 50-311 cc: See next page DISTRIBUTION Dockef File PUBLIC PDl-2 Reading OFFICE POI-~ PM JZwolinski JStolz JWermeil NAME
~*
PMilano:cw TLCICl,rK DATE d-13 /98 OFFICIAL RECORD COPY DOCUMENT NAME: SA94726.L TR Sincerely,
/SI Patrick D. Milano, Senior Project Manager Project Directorate 1-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation PMilano WHehl, RGN-1 JLinville, RGN-1 HGarg
]- I 2:, /98 TClark JMoore, OGC GKelly ACRS
Mr. Harold W. Keiser Public Service Electric.& Gas Company cc:
Jeffrie J. Keenan, Esquire Nuclear Business Unit-N21 P.O. Box236 Hancocks Bridge, NJ 08038 General Manager - Salem Operations Salem Nuclear Generating Station P.O. Box236 Hancocks Bridge, NJ 08038 Mr. Louis Storz Sr. Vice President - Nuclear Operations Nuclear Department P.O. Box236 Hancocks Bridge, NJ 08038 Senior Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer0509 Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN415 Trenton, NJ 08625-0415 Maryland Office of People's Counsel 6 St. Paul Street, 21st Floor Suite 2102 Baltimore, MD 21202 Ms. R. A. Kankus Joint Owner Affairs PECO Energy Company 965 Chesterbrook Blvd., 63C-5 Wayne, PA 19087 Mr. Elbert Simpson Senior Vice President-Nuclear Engineering Nuclear Department P.O. Box236 Hancocks Bridge, NJ 08038 Salem Nuclear Generating Station, Units 1and2 Richard Hartung Electric Service Evaluation Board of Regulatory Commissioners 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of-Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Manager-Licensing and Regulation Nuclear Busienss Unit - N21 P.O. Box236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Manager - Joint Generation Atlantic Energy 6801 Black Horse Pike Egg HarborTwp., NJ 08234-4130 Carl D. Schaefer External Operations - Nuclear Delmarva Power & Light Company P.O. Box231 Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division Chief Engineer 6 St. Paul Centre Baltimore, MD 21202-6806