Industrial Process Wastewater Sludge Rept, for May 1995.W/
ML18101A856
Person / Time
Site: Salem  PSEG icon.png
Issue date: 05/31/1995
From: Hagan J, Quinn R
Public Service Enterprise Group
To: Caporale G
NEW JERSEY, STATE OF
References
RPC95-154, NUDOCS 9508020017
Download: ML18101A856 (8)


Text

r..

e

~~,:*~~. PSl§G Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit Chief George Caporale July 24, 1995 RPC95-154 NJ Department of Environmental Protection Bureau of Information Systems CN-029 Trenton, NJ 08625 SALEM GENERATING STATION NJPDES PERMIT NO. NJ0005622 INDUSTRIAL PROCESS WASTEWATER SLUDGE REPORT

Dear Sir:

so.. 2,~

3,,

Attached please find the Industrial Process Wastewater Sludge Report for the Non-Radiological Liquid Waste Disposal System (NRLWDS) for May 1995.

In accordance with the November 1, 1993 letter from the NJDEP -

Bureau of Pretreatment and Residuals, PSE&G is completing this report during months in which sludge is removed for disposal.

During the month of May, sludge was removed from the NRLWDS and shipped to American Ecology, Inc. in Tennessee for ultimate disposal as low level radioactive waste.

We are also providing the results of radiological and metals analyses for your information.

If you have any questions, please feel free to contact Pat McCabe*

of Licensing and Regulation at (609) 339-1245.

Attachments (2)

Form T-VWX-OlOA Form T-VWX-OlOB 0.10079

~-

9508020017 950531 PDR ADDCK 05000272 R

PDR

  • .r£~

1, '

95*2168 REV, 6/94

I

  • ~. -. ~

NJDEP -

SQAR May 1995 2

C USNRC -

Document Control Desk Manager - Licensing and Regulation M. Vaskis D. Hurka Central Record Facility File RPC95-154 f:S"'\\

  • e 7/24/95

Form T-VWX-014 2i92 NEW JERSEY DEPT. OF ENVIRONMENTAL PROTECTION AND ENERGY MONITORING REPORT - TRANSMITTAL SHEET NJPDES NO.

REPORTING PERIOD MO.

YA.

MO. YA.

THAU PERMITTEE:

Name Public Service Electric arid Gas Company Address P.O. Box 236 Hancock's Bridge, NJ 08038 FACILITY:

Name Salem Nuclear Generating Station Address Alloway Creek Neck Road Hancock's Bridge Telephone (609) 935-6000 FORMS ATTACHED (Indicate Quantity of Each)

SLUDGE REPORTS

  • Sanitary DT-VWX-007 D

T-VWX-008. D T-VWX-009 SLUDGE REPORTS

  • Industrial QJT-VWX-01 DA QlT-VWX-01 OB
  • WASTEWATER REPORTS DT-VWX-011 D

T-VWX-012 D T-VWX-013 GROUNDWATER REPORTS D VWX-015{A,8)

D VMX-016 D VMX-017 (County) Salem OPERATING EXCEPTIONS DYE TESTING TEMPORARY BYPASSING DISINFECTION INTERRUPTION MONITORING MALFUNCTIONS UNITS OUT OF OPERATION OTHER (Detail any "Yes" on reverse side in appropriate space.)

YES NO D *r21 D r2l D r2l D r2l D r2l D ~

NPDES DISCHARGE MONITORING REPORT DEPA FORM 3320-1 NOTE: The "Hours Attended at Plant" on the reverse of this sheet must also be completed.

AUTHENTICATION-I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

LICENSED OPERATOR Name(Printed)

. Ric.hard F *. Quinn Gcade & Re~~~:-N-<0944.

Sig~e~2~

Date

~'4-- ;;.._/ / * / C/1S-PRINCIPAL EXECUTIVE OFFICER or DULY AUTHORIZED REPRESENTATIVE Name (Printed)

Joseph J. Hagan Title (Printed)

VP - Nuclear Operations

&.1-r1"/15~..

. ""\\

~natu<e ~-

Date

~-

- Z

I OPERATING EXCEPTIONS DETAILED Page 2 HOURS ATTENDED AT PLANT Month ~

Year lli.§.J Day of Month 1

2 3

4 5

6 7

8 9 10 11 12 13 14 15 16 Licensed Operator 8

8 8

8 8

0 0

8 8

8 8

8 0

0 8

8 Others 4

4 4

4 4

0 0

4 4

4 4

4 0

0 4

4 Day of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Licensed Operator 8

8 8

0 0

8 8

8 8

8 0

0 0

8 8

Others 4 *4 4

0 0

4 4

4 4

4 0

0 0

4 4

INDUSTRIAL PROCESS WASTEWATER SLUDGE REPORT DISCHAl'GE PERMIT NO.

! o ! u ! o ! s ! 6 ! 2 *12 !

RE.PORTING PERIOD Mo.

Yr.

L..£.L:j 11 I 9 !9 I 5 I FACIL!I"Y NAME.:

Salem Non-Radiologieal Liquid Waste Disposal System' A. INFORMATION ON SLUDGE PRODUCED IN TREATMENT PROCESSES

l. A v1n11 Daily Sludp Prodw:ticn (Dry Tcm/Day)
2. Avcnp Daily Sludp Production (GailclmlOiy)
3. Awnp Total Solidi o! ShJdp

(~ byw.iaiX)

  • a. INFORMATION ON SLl!DGE REMOVED FOR ULTIMATE MANAGEMENT
1. A~1* Daily Slud1e Removal

<Dry r onslDay>

2. Aven&o Daily Slqe Removal (G&il~)
3. Toul Solids Before Oewau:rinJ

(%by waism)

4. Toul Solids Mt. Dewatsrin&

(% by Wlip)

5. pH (Stmdard unia)
6. COD (Chcmic:&l Oxnca Demand)

(mlfl)

7. Toul Oil am Greue

(% by-..ishl)

C. DISPOSAL METHOD(S)

(SI* cod* belo*)

LANDFILL HAULll METHOD DESCR.llTION CODE REGISnY R.l.G~Y

~ I A:"*~ E IR I I I c I A I NI jEICIOILIOll I I I

I II I I I

LJ I G I y I I I I I

I I

I I I I I

11 I

I I

I II I

I I LJ I

I I I I I

I l

I I

I I I I 11 I

I I I 11

  • 1 I I DISPOSAL METHOD CODES:

1 - Und Applicuioa at' NJPDES Permiueci SiLI 6 - Mm&pd u & Huardous W1111 2 - S~tc Approved Discnbwioa Permit 7

  • Other (S peci.ty:

I 3

  • Incinc:nti.aa 8
  • Nomi R.ano¥ed 4-0cemD~
9. Lmdfill 5 *Out of St.ua
    • o.
1. Tou.l Niao1cn rn~
2. Ammmia Nicropn m~
3. Niinta Nitro1m rnl/kl
4. ?hospboru

~Ii. SOLID WASTE CLAs.<IFICATION ID NUMBER ml/kl

  • M wst I>>,.. ptN1.l!4 olliy if sLJMJ.i* is rartOWfi /r0ttt,.TrltJlllWJfl W crli siU tbuilt1 IM nportiAi p#rio4.

-~llSt ~ nporwi olli'f ifs~ is apfXW:' ID laM/or so4J imprawtrtatt.

I I

I PapL!JoILJ I !< ! 0 I 1 *o 11 I I ! I. ! I I I I '* -

11

~ I 0 I I ! I I I I I I I. I I I I I 9 I 5 1.

11 1° I 0 I I 11a.o I I I 9 I 5 I I I I I I I '*

I I I I P!llMrr NO.

llRl 0 P 1°1 3 17 15 I 11 I

I I I I I

I 11 I I I I ! I I

)

I I I I I I '*

I I I I I I 1.

I I I I I I 1.

I I I I I I I.

LLJ I

I I

l

... ~.. 0.oe S/89 e

e

    • ew Jersey Dcparuncnc of Envir:mmcnta! Proc,ecuon Division of Water Rcsourt:C3 INDUSTRIAL PROCESS-WASTEWATER SLUDGE REPORT (Continued)

REPORTING PERIOD Mo.

Yr:

DISCHARGE PERMIT NO.

1010101sl6l2!21 I o I s I 11 19 19 I s I Page L:J of t.:J FACILITY NAME:

Salem Non-Radiological Liquid Waste Disposal System SLUDGE SAMPUNG LOCATION:

No. 1 Clarifier

~--~------~~~--~~----~-~~-~

STORET CODE op11101s op.

10 Io I 7 011101217 0111013 14 011101317 o I 1 Io 14 12 OiJlfOl416I O!Ol9l217l 011 o !6 17 I I o I 1 0 19 12 I I o I l 0 !5 5 I

-* 1 I

I PARAMETER Aluminum Ba!itum Cadmium Chromium Cobalt Copper Iron Magnesium Nickel Zinc Manganese CERTIFICATION OF AUTHENTICITY TOTAL PHASE (dry wei1ht basis, meJk1) 12 fO I 4 I I 2 10 IO I

I 1 1 o

  • I 21 o.

4121110.

a I 2 14 10

  • 1 1 s I 9, 9 16 17
  • 9 I 19 5
  • 8 I

. NONE.

DETECTED LJ LJ w LJ LJ LJ LJ LJ LJ LJ LJ*

LI LJ LJ LJ LJ LJ LJ LJ LJ LJ LJ LJ

~

1--rne of Auc.horized Agent (print) _ ___::J:.::,os:::.;e:.t:.ph:..:......::J;...

  • ..:..:.Ha::..::g!.:::an~---------------------

- *&nar.ure of Authorized Agent -------,~r'l-+-..:,...::;._.l,------------

Date I B'l/,c

, }

Title of Authorized Agent _....!V.!...'.i c:.:::e....!P...!..r.::..:es:..:,'.:::::..:.....:...~.;;;:L-.:'.!'...:.:..:::..:.:..:.:.:.:__ ___________

--:---:-----~

LaboralOry Name __

N_a_t_i o_na_l_E_

.. n_"v1_* r_on_m_~n_t_~1_Te_s_t1_*

n...;...g_, _rn_c_. ---------

Cert No... 08153

cc: MTSA00194 Parameter Radiological GENERAL ENGINEERING LABORATORIES Laboratory_Cerllflcallons Meeting today's needs with a vision for tomorrow.

CERTIFICATE OF ANALYSIS Client Contact Mountain States Analytical 1645 West 2200 South Salt Lake City, Utah 84119 Mr. Scott Fraser Report Date: January 18, 1995 Sample ID

6912-28315 Lab ID
9412450-08 Matrix
Soil Date Collected
12119194 Date Received
12127194 Priority
Routine Collector
Client Qualifier Result Unlts Method STATE GEL EPI FL E87156187294 E87472/87458 NC 233 SC 10120 10582 TN 02934 VA 00151 WI 99988779 Page 1 of2 Analyst Date Time Batch Gamma PHA - 49 items Actinium-228 3.49

+/-0.743 pCi/g EPIA-013B MDS 01/12195 '1148 59024 Americium-241 2.00

+/- 0.403 pCi/g EPIA-013B Antimony-124 1.00

+/- 0.187 pCi/g EPIA-013B Antimony-125 0.523

+/- 0.256 pCi/g EPIA-013B Barium-133 1.00

+/-0.145 pCi/g EPIA-013B Barium-140 2.01

+/- 1.06 pCi/g EPIA-013B Beryllium-7 1.93

+/-1.09 pCi/g EPIA-013B Bismuth-212 1.90

+/- 1.38 pCi/g EPIA-013B Bismuth-214 4.20 __, +!- 0.500 pCi/g EPIA-013B Cerium-139 1.bo

+/-0.112 pCi/g EPIA-013B Cerium-141 1.00

+/-0.223 pCi/g EPIA-013B Cerium-144 1.08

+/-0.637 pCi/g EPIA-013B Cesium-134 0.344

+/-0.144 pCi/g EPIA-013B Cesium-136 1.06

+/- 0.538 pCi/g EPIA-013B Cesium-137 1.30

+/- 0.261 pCi/g EPIA-013B Cbromium-51 237

+/- 1.34 pCi/g EPIA-013B Cobalt-56 1.00

+/- 0.136 pCi/g EPIA-013B Cobalt-57 0.141

+/-0.0742 pCi/g EPIA-013B Cobalt-58 1.00

+/-0.127 pCi/g EPIA-013B Cobalt-60 3.62

+/- 0.421 pCi/g EPIA-013B Europium-152 0.523

+/- 0.286 pCi/g EPIA-013B Europium-154 0.945

+/- 0.571 pCi/g EPIA-013B Europium-155 1.00

+/- 0.411 pCi/g EPIA-013B Iodine-131 5.00

+/- 0.709 pCi/g EPIA-013B Iridium-192 1.00

+/-0.107 pCi/g EPIA-013B Iron-59 1.00

+/- 0.264 pCi/g EPIA-013B Lead-212 4.68

+/- 0.382 pCi/g EPI A-013B Lead-214 5.38

+/-0.625 pCi/g EPIA-013B

.:;;~*:....

I llllll lllll lllll lllll lllll lllll lllll llll llllll lllfl 11111111 P 0 Box 30712

  • Charleston. SC 29417 * (80:'\\) 556-8171
  • Fax r80> l 766-I I 78*9412450-08*

GENERAL ENGINEERING LABORATORIES Laboratory Certlflcallons Client:

Contact:

Meeting today's needs with a vision for tomorrow.

CERTIFICATE OF ANALYSIS Mountain States Analytical 1645 West 2200 South Salt Lake City, Utah 84119 Mr. Scott Fraser cc: MTSA00194 Report Date: January 18, 1995 Sample ID

6912-28315 Parameter Qualifier Result Manganese-54 0.233

+!- 0.119 Mercury-203 1.00

+/- 0.132 Neodymium-147 4.25

+/-2.45 Neptunium-239 1.00

+/- 0.517 Niobium-94 1.00

+/- 0.101 Niobium-95 1.00

+/-0.269 Potassium-40 2.03

+/- 1.67 Promethium-144 0.161

+I- 0.0886 Promethium-146 0.232

+/-0.124 Radium-226 4.20

+/- 0.500 Radium-228 3.49

+!- 0.743 Ruthenium-106 1.64

+/- 0.927 Silver-HOM 1.00

+/- 0.122 Sod.ium-22 0.700

+/- 0.0834 Thallium-208 2.00

+/- 0.278 Thorium-234 5.82

+/- 3.37 Tin-113 1.QP

+/- 0.137 Uranium-235 1.00

+/- 0.586 Yttrium-88 0.217

+!- 0.109 Zinc-65 0.523

+/- 0319 Zirconium-95 1.00

+/~ 0.223 This data report has been prepared and reviewed in accordance with General Engineering Laboratories standard operating procedures. Please direct Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g any questions to your Projeet Manager, Nancy Slater at (803) 556-8171.

Analytical Report Specialist Method EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B EPIA-013B STATE GEL EPI FL E87 l 56187294 E87472187458 NC 233 SC 10120 10582 TN 02934 VA 00151 WI 999ssn9 Page 2 of 2 Analyst Date Time Batch MDS 01/12/95 1148 59024 P O Box 30712

  • Charleston. SC 29417 * <803 l 556-8171
  • Fax (803 l 766-1 I 7&9412450-08*