,_

(

May 3, 1995 Mr. Leon R..El tason Chief Nuclear. Office.r & President -

Nuclear Business Unit Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, NJ.08038

SUBJECT:

'SALEM NUCLEAR GENERATING STATION, UNIT 1 - RELIEF REQUEST TO USE A PORTION OF THE 1992 EDITION OF THE ASME CODE SECTION XI (TAC NO.

M918S5)

Dear Mr. Eliason:

By letter dated Marc.h ~O, 1995, you requested approval to use a portion of the 1992 Edition of the American Society of Mechanical Engineers (ASME) Code Section XI pursuant to the provisions of 10. CFR 50.~5a(a)(3). Specifically, you tequested approval to us~ the automatic (ma~hine) Gas Tungsten Arc Welding process for S:alem Nuclear Generating Station, Unit 1.

The NRC staff has _*reyi*ewed your submittal and has concluded that, pursuant to 10 CFR 50.55a.(aJ{3}(i), thls weJd p.rocess may be used.

The staff's safety evaluatfon is enclosed.

Docket No *. 50... 272 Enclosure.: Safety Evaluation cc w/encl:

See next page DISTRIBUTION~

Docket File PUBLIC PDI-2 Rdg.

WRussell/FMir-ag.l ia, 0/1261_8 RZimmerman, 0/12G18 RSpessar-d, 0/9A2 JLieber-man, D OE Sincerely,

/SI Leonard N.

Ol~hari, Project Manager Proj~ct Directorate 1-2 Division of Reactor Projects - I/II Office ~f Nuclear Reactor Regulation svarga JZ~olinski JFStolz LOlshan OGC EJordan, D/AEOD GHill 2 ACRS(4)

OPA WDean, Ofl7G21 TMcLellan JWhite, RGN-1 OFFICE PDJ..,;2 PM LOl sh an :-mw 4 18/95 95050'90269 950503 PDR ADOCK 05000272 p

PDR

--- I

.. ' ~d

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555--0001 May 3, 1995 Mr. Leon R. Eliason Chief Nuclear Officer & President -

Nuclear Business Unit Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT 1 - RELIEF REQUEST TO USE A PORTION OF THE 1992 EDITION OF THE ASME CODE SECTION XI (TAC NO.

M91885)

Dear Mr. Eliason:

By letter dated March 20, 1995, you requested approval to use a portion of the 1992 Edition of the American Society of Mechanical Engineers {ASME) Code Section XI pursuant to the provisions of 10 CFR 50.55a{a){3). Specifically, you requested approval to use the automatic {machine) Gas Tungsten Arc Welding process for Salem Nuclear Generating Station, Unit 1.

The NRC staff has reviewed your submittal and has concluded that, pursuant to 10 CFR 50.55a{a){3){i), this weld process may be used.

The staff's safety evaluation is enclosed.

Docket No. 50-272

Enclosure:

Safety Evaluation cc w/encl:

S~e next page Sincerely,

<fa,.rt1 [/) eljlv Leonard N. Olshan, Project Manager Project Directorate 1-2 Division of Reactor Projects ~ I/II Office of Nuclear Reactor Regulation

Mr. Leon R. Eliason e Public Service Electric & Gas Company cc:

Mark J. Wetterhahn; Esquire Winston & Strawn 1400 L Street NW Washington, DC 20005-3502 Richard Fryling, Jr., Esquire Law Department - lower SE 80 Park Place Newark, NJ 07101 Mr. John Summers General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. J. Hagan Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Mr~ Charles S. Marschall, Sen~or Resident Inspector Salem Generating Station U.S. Nuclear Regulatory Convnission Drawer I Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Maryland Office of People's Counsel 6 St. Paul Street, 21st Floor Suite. 2102 Ba1timore, Maryland 21202 Ms. R. A. Kankus Joint Owner Affairs PECO Energy Company 965 Chesterbrook Blvd., 63C-5 Wayne, PA 19087 Mr. S. LaBruna Vice President - Nuclear Engineering Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Salem Nuclea~enerating Station, Units 1 and 2 Richard Hartung Electric Service Evaluation Board of Regulatory Commissioners 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Frank X. Thomson, Jr., Manager Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Ms. P. J. Curham MGR. Joint Generation Department Atlantic Electric Company P.O. Box 1500 6801.Black Horse Pike Pleasantville, NJ 08232 Carl D. Schaefer External Operations -

Nuclea~

Delmarva Power & Light Company P.O. Box 231 Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division Chief Engineer 6 St. Paul Centre Baltimore, MD 21202-6806