ML18101A641

From kanterella
Jump to navigation Jump to search

Forwards SE Re First ten-year Interval Inservice Insp Program Plan Final Requests for Relief for Salem Unit 2. Requests for Relief 1,2,3 & 5 Granted IAW 10CFR50.55a(g)(6) (I) & Request for Relief 4 IAW 10CFR50.55a(a)(3)(ii)
ML18101A641
Person / Time
Site: Salem 
Issue date: 04/13/1995
From: Stolz J
Office of Nuclear Reactor Regulation
To: Eliason L
Public Service Enterprise Group
Shared Package
ML18101A642 List:
References
TAC-M84658, NUDOCS 9504180354
Download: ML18101A641 (3)


Text

->Mr. Leon. R. Eliason A Chief Nuclear Officer~resident Nucl~ar Business Unit Public Service* Electric and Gas Company Post Office Box 236 Hancocks Bridge, NJ 08038

.il 13, 1995

SUBJECT:

EVALUATION OF THE FIRST IO-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN FINAL REQUESTS FOR RELIEF FOR SALEM GENERATING STATION, UNIT 2 (TAC NO. M84658)

The staff, with technical assistance from its contractor, the Idaho National Engineering Laboratory (INEL), has reviewed and evaluated the information that you provided in a letter dated September 28, 1992, related to the first ten-year interval inservice inspection program plan final requests for relief for the Salem Generating Plant, Unit 2. Additional information was provided in your letter dated December 10, 1993.

Based on the information submitted, the staff adopts the contractor's conclusions and recommendations presented in. the Technical Evaluation Report attached. Requests for Relief Nos. 1, 2, 3, and 5 are granted pursuant to 10 CFR 50.55a(g)(6)(i) and the alternative proposed in Relief No. 4 is authorized pursuant to 10 CFR 50.55a(a)(3)(ii). The staff's evaluation and conclusions are contained in the enclosed safety evaluation.

Docket No. 50-311

Enclosure:

Safety Evaluation cc w/encl: See next page DISTRIBUTION:

Sincerely,

/SI John F. Stolz, Director Project Directorate 1-2 Division of Reactor Projects - I/II Offi~e of Nuclear Reactor Regulation Docket File JLieberman, D/OE OGC WDean, ED00/17G21 JWhite, RI PUBLIC SVarga PDI-2 Rdg.

JZwolinski WRussell/FMiraglia JStolz RZimmerman MO'Brien RLSpessard, D/DOTS LOlshan DISK/DOCUMENT NAME:

a:\\SA84658.ISI

  • SEE PREVIOUS CONCURRENCE EJordan, D/AEOD GHil l (2)

ACRS(4)

OPA OC/LFDCB To receive a co y of this docunent, indicate in the box:

"C" = Co y w/o attachment, "E" = Co y w/attachment, "N" = No copy OFC PDl-2/LA

,DI-2/PM OGC NAME MO'Brien LOlshan:tlc MYoun DATE if/I} /tJ5 03/31/95 I I

~\\'

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555--0001 April 13, 1995 Mr. Leon R. Eliason Chief Nuclear Officer & President-Nuclear Buliness Unit.

Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

EVALUATION OF THE FIRST IO-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN FINAL REQUESTS FOR RELIEF FOR SALEM GENERATING STATION,

_UNIT 2 (TAC NO. M84658)

Dear Mr. Eliason:

The staff, with technical assistance from its contractor, the Idaho National Engineering laboratory {INEL), has reviewed and evaluated the information that you provided in a letter dated September 28, 1992, related to the first ten-year interval inservice inspection program plan final requests for relief for the Salem Generating Plant, Unit 2. Additional information was provided in your letter dated December 10~ 1993.

Based on the information submitted, the staff adopts the contractor's conclusions and reconvnendations presented in the Technical Evaluation Report attached. Requests for Relief Nos. 1, 2, 3, and 5 are granted pursuant to 10 CFR 50.55a(g)(6)(i) and the alternative proposed in Relief No. 4 is authorized pursuant to 10 CFR 50.55a(a)(3)(ii). *The staff's evaluation and conclusions are contained in the enclosed safety evaluation.

Docket No. 50-311

Enclosure:

Safety Evaluation cc w/encl:

See next page Sincerely, ao n F. Stolz, Directo '

Pr. ject Directorate 1-ivi sion of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation

  • Mr. Leon R. Eliason ~

Public Service Electric & Gas Company cc:

Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street NW Washington, DC 20005-3502 Richard Fryling, Jr., Esquire Law Department - Tower SE 80 Park Place Newark, NJ 07101 Mr. John Summers General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. J. Hagan Vice President - Nuclear Operations

  • Nuclear Department P.0. Box 236 **

Hancocks Bridge, New Jersey 08038 Mr. Charles S. Marschall, Senior Resident Inspector Salem Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Maryland Office of People's Counsel 6 St. Paul Street, 21st Floor Suite 2102 Baltimore, Maryland 21202 Ms. R. A. Kankus Joint Owner Affairs PECO Energy Company 965 Chesterbrook Blvd., 63C-5 Wayne, PA 19087 Mr. S. LaBruna Vice President - Nuclear Engineering Nuclear, Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Salem Nuclear Generating Station, Units 1 and 2 Richard Hartung Electric Service Evaluation Board of Regulatory Commissioners 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Frank X. Thomson, Jr., Manager Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Ms. P. J. Curham MGR. Joint Generation Department Atlantic Electric Company P.O. Box 1500 6801 Black Horse Pike Pleasantville, NJ 08232 Carl D. Schaefer External Operations ~ Nuclear*

Delmarva Power & Light Company P.O. Box 231 Wilmington, DE.19899 Public Service Commission of Maryland Engineering Division

  • Chief Engineer 6 St. Paul Centre Baltimore, MD 21202-6806