Text

t,*

,

' . *

February 21, 1995

Mr. Leon R. Eliason

President and Chief Nuclear Officer

Public Service Electric and Gas Company

P.O. Box 236

Hancocks Bridge, NJ

08038

SUBJECT:

NRC INSPECTION NOS.

50-272/~4-35; 50-311/94-35

Dear Mr. Eliason:

The enclosed report documents an inspection for public health and safety,

conducted by Mr. C. Marschall, Senior Resident Inspector and other members of

the NRC staff at the Salem Nuclear Generating Station for the period between

December 18, 1994 and January 28, 1995. These finding were previously

discussed with Mr. J. Summers, General Manger-Salem Operations, and other

members of your staff.

During this period, we noted performance improvement relative to system

engineering inspection activities and timely communication of related concerns

to operations.

We also observed that your Operations organization effectively

contributed to successful completion of complex safety-related maintenance

activities.

We also noted your safety conscious decision to fully resolve the

pressurizer safety relief valve leakage problems affecting Unit 2 before *

returning the unit to service.

We also observed your continued activities to resolve recurring Automatic Test

Insertion (ATI) faults within your Safeguard Equipment Control (SEC) system.

However, it appears that a more thorough root cause approach to previous ATI

test faults may have avoided the operational challenge to Unit 1 operators due

to the recurri.ng SEC operability problem.

Based on the results of this inspection, it appears that you failed to adhere

to the requirements of Technical Specification 3.3.2.1.b relative to

maintaining a minimum of one engineered safety feature actuation steam flow

instrumentation channel operable while Unit 2 was in Mode 3 on December 26,

1994.

However, since this violation was self-identified by your operating

organization, and our inspectors confirmed that you met the criteria for

enforcement discretion as specified in 10CFR2, Appendix C, Section VII, this

violation will not be cited.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice, a copy of

this letter will be pl aced in the NRC Pub l i c Dotument Room.

No response to

this letter is required.

9503010076 950221

PDR

ADOCK 05000277

G

PDR

,fiDI)'

  • -

Mr. Leon R. Eliason

2

Your cooperation with us is appreciated.

Docket Nos. 50-272; 50-311

Enclosures:

Sincerely,

ORIGINAL SIGNED BY:

John R. White, Chief

Projects Section No. 2A

Division of Reactor Projects

1.

NRC Inspection Report Nos. 50-272/94-35; 50-311/94-35

cc w/encl:

J. J. Hagan, Vice President-Operations

S. LaBruna, Vice President - Engineering and Plant Betterment

C. Schaefer, External Operations - Nuclear, Delmarva Power & Light Co.

P. J. Curham, Manager, Joint Generation Department,

Atlantic Electric Company

R. Burricelli, General Manager - Information Systems & External Affairs

J. Summers, General Manager - Salem Operations

J. Benjamin, Director of Quality Assurance and Safety Review

F. Thomson, Manager - Licensing and Regulation

R. Kankus, Joint Owner Affairs

A. C. Tapert, Program Administrator

R. Fryling, Jr., Esquire

M. J. Wetterhahn, Esquire

Consumer Advocate, Office of Consumer Advocate

William Conklin, Public Safety Consultant, Lower Alloways Creek Township

D. Screnci, PAO (2)

PUBLIC

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New Jersey

State of Delaware

.

~ Mr. Leon R. Eliason

3

bee w/encl:

Region I Docket Room (with concurrences)

K. Gallagher

bee w/encl: (Via E-Mail)

D. Moran, Project Manager, NRR

J. Stolz, PDI-2, NRR

Inspection Program Branch, NRR (IPAS)

DOCUMENT NAME:

a:9435.sal

To mceive a copy all this docummt. lndicat In

attachmentjenclosure "N' = No copy

OFFICE

p

NAME

chall

DATE

/95