ML18101A451
| ML18101A451 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 12/22/1994 |
| From: | Modes M NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Eliason L Public Service Enterprise Group |
| Shared Package | |
| ML18101A453 | List: |
| References | |
| NUDOCS 9501110001 | |
| Download: ML18101A451 (2) | |
See also: IR 05000272/1994029
Text
December 22, 1994
Mr. Leon R. Eliason
Chief Nuclear Officer & President
Nuclear Business Unit
Public Service Electric and Gas Company
P. 0. Box 236
Hancocks Bridge, New Jersey 08038
SUBJECT:
COMBINED INSPECTION REPORT NOS. 50-272/94-29 AND 50-311/94-29
Dear Mr. Eliason:
This letter refers to the announced safety inspection conducted by
Ms. C. D. Beardslee of this office from November 7-18, 1994, at Salem Nuclear
Generating Station, Units 1 and 2.
Ms. Beardslee discussed the findings of
the inspection with members of your staff at the conclusion of the inspection.
Areas examined during this inspection are described in the NRC Region I
Inspection Report, which is enclosed with this letter. The inspection was
directed toward inservice inspection (ISI) activities. Within these areas,
the inspection consisted of examinations of procedures and representative
records, interviews with personnel, and observations by the inspector.
Within the scope of this inspection, no violations or deviations were
observed. Overall, the portions of the ISI program implementation that were
reviewed were good.
In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of
this letter and its enclosures will be placed in the NRC Public Document Room.
You need not respond to this letter. Your cooperation is appreciated.
Sincerely,
(ll*igj aal Signe(! }Jp_
Michael C. Modes, Chief
Materials Section
Division of Reactor Safety
Enclosure:
Inspection Report Nos. 50-272/94-29
and 50-311/94-29 w/Attachment 1
Docket Nos. 50-272; 50-311
1lDI~
9501110001 941222
ADOCK 05000272
G
December 22, 1994
Mr. Leon R. Eliason
2
cc w/encl:
J. J. Hagan, Vice President-Operations/General Manager-Salem Operations
S. LaBruna, Vice President - Engineering and Plant Betterment
C. Schaefer, External Operations - Nuclear, Delmarva Power & Light Co.
R. Hovey, General Manager - Hope Creek Operations
F. Thomson, Manager, Licensing and Regulation
J. Robb, Director, Joint Owner Affairs
A. Tapert, Program Administrator
A. Giardino, Acting Manager, Quality Assurance
B. Hall, Acting Manager, Nuclear Safety Review
R. Fryling, Jr., Esquire
M. Wetterhahn, Esquire
P. J. Curham, Manager, Joint Generation Department,
Atlantic Electric Company
Consumer Advocate, Office of Consumer Advocate
William Conklin, Public Safety Consultant, Lower Alloways Creek Township
Public Service Commission of Maryland
K. Abraham, PAO (2)
PUBLIC
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector
State of New Jersey
State of Delaware
bee w/encl:
Region I Docket Room {with concurrences)
J. Wiggins, DRS
Kay Gallagher; DRP
DRS Fil es (2)
bee w/encl: (Via E-Mail)
L. 01 sh an, NRR
W. Dean, OEDO
J. Stolz, PDl-2, NRR
M. Shannon, ILPB
M. Callahan, OCA
C. D. Beardslee, DRS
K. Battige, EMCB/NRR
DOCUMENT NAME:
A:SAL9429.INS
To receive a copy of this document, indicate in the box: "C' = Copy without attachmentjenclosure "E' = Copy with attachment/enclosure "N" = No
copy
OFFICE
RI/DRS
I
NAME
Beardslee/dm
DATE
12/19/94
12/
/94
12/
/94
12/
/94