Monthly Operating Rept for Jan 1994 for Salem Unit 1.W/
ML18100A874
Person / Time
Site: Salem 
Issue date: 01/31/1994
From: Hagan J, Heller R, Morroni M
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9402180104
Download: ML18100A874 (11)


Text

Public*Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Salem Generating Station February 14, 1994 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Dear Sir:

MONTHLY OPERATING REPORT SALEM NO. 1 DOCKET NO. 50-272 In compliance with Section 6.9.1.6, Reporting Requirements for the Salem Technical Specifications, the original copy of the monthly operating reports for the month of January 1994 are being sent to you.

Average Daily Unit Power Level Operating Data Report Unit Shutdowns and Power Reductions Safety Related Maintenance 10CFR50.59 Evaluations Operating Summary Refueling Information Sincerely yours, RH:pc cc:

Mr. Thomas T. Martin Regional Administrator USNRC Region I 631 Park Avenue King of Prussia, PA 19046 Enclosures 8-1-7.R4 The Energy People 0p*~~21~g5g~ 6~86~~72 1

PDR R

--~*~~-*-;;;:.

ager -

tions 95-2189 (10M) 12-89

~VERAGE DAILY UNIT POWER L~L Docket No.:

50-272 Unit Name:

Salem #1 Date:

02/10/94 Completed by:

Mike Morroni Telephone:

339-2122 Month January 1994 Day Average Daily Power Level Day Average Daily Power Level (MWe-NET)

(MWe-NET) 1 0

17 0

2 0

18 0

3 0

19 0

4 0

20 0

5 0

21 0

6 0

22 0

7 0

23 0

8 0

24 0

9 0

25 0

10 0

26 0

11 0

27 0

12 0

28 0

13 0

29 0

14 0

30 0

15 0

31 0

16 0

P. 8.1-7 Rl

e OPERATING DATA REPORT e Docket No:

Date:

Completed by:

Mike Morroni Telephone:

Operating Status

1.

Unit Name Salem No. 1 Notes

2.

Reporting Period January 1994

3.

Licensed Thermal Power (MWt) 3411

4.

Nameplate Rating (Gross MWe) 1170

5.

Design Electrical Rating (Net MWe) 1115

6.

Maximum Dependable capacity(Gross MWe) 1149

7.

Maximum Dependable Capacity (Net MWe) 1106

8.

If Changes Occur in Capacity Ratings (items 3 through 7)

Report, Give Reason NA

9.

Power Level to Which Restricted, if any (Net MWe)

10. Reasons for Restrictions, if any
12. Hours in Reporting Period
12. No. of Hrs. Rx. was Critical
13. Reactor Reserve Shutdown Hrs.
14. Hours Generator On-Line
15. Unit Reserve Shutdown Hours
16. Gross Thermal Energy Generated (MWH)
17. Gross Elec. Energy Generated (MWH)
18. Net Elec. Energy Gen.

(MWH)

19. Unit Service Factor
20. Unit Availability Factor
21. Unit Capacity Factor (using MDC Net)
22. Unit Capacity Factor (using DER Net)
23. Unit Forced Outage Rate This Month 744 118.2 0

0 0

6895.2 0

-17717 0

0 0

0 0

N/A Year to Date 744 118.2 0

0 0

6895.2 0

-17717 0

0 0

0 0

50-272 02/10/94 339-2122 since Last NIA Cumulative 145441 95250.17 0

91887.84 0

290779209.2 96535970 91919836 63.2 63.2 57.1 56.7 21.0

24. Shutdowns scheduled over next 6 months (type, date and duration of each)

None.

25. If shutdown at end of Report Period, Estimated Date of Startup:

Unit returned to service on 2/2/94.

8-1-7.R2

NO.

DATE 0135 01/01/94 1

2 F:

Forced S:

Scheduled DURATION TYPE1 (HOURS)

REASON 2 s

744 Reason A-Equipment Failure (explain)

B-Maintenance or Test C-Refueling D-Requlatory Restriction c

UNIT SHUTDOWN AND POWER REDUCTIONS REPORT MONTH JANUARY 1994 METHOD OF SHUTTING DOWN REACTOR 4

LICENSE EVENT REPORT #

3 Method:

1-Manual 2-Manual Scram SYSTEM CODE4 RC E-Operator Training & License Examination F-Administrative 3-Automatic Scram 4-Continuation of Previous Outage 5-Load Reduction 9-0ther G-Operational Error (Explain)

H-Other (Explain) 4 DOCKET NO. :_,5'"-"0;..,-*=27'-=2..,,..,._ __ _

UNIT NAME:

Salem #1 DATE:

02-08-94 COMPLETED BY:

Mike Morroni TELEPHONE:

339-2122 COMPONENT CAUSE AND CORRECTIVE ACTION CODE5 TO PREVENT RECURRENCE FUELXX NUCLEAR NORMAL REFUELING Exhibit G - Instructions for Preparation of Data Entry Sheets for Licensee Event Report CLER) File (NUREG-0161) 5 Exhibit 1 - same Source

SA.~ETY -RELATED MAINT,ANCE MdNTH: -

JANUARY 1994 DOCK' NO:

UNIT NAME:

50-272 SALEM 1 DATE:

COMPLETED BY:

TELEPHONE:

FEBRUARY 10, 1994 R. HELLER (609)339-5162 WO NO UNIT 931116130 1

931214109 1

931214205 1

931229159 1

940103180 1

940110247 1

940117073 1

940122099 1

940122100 1

EQUIPMENT IDENTIFICATION VALVE 12MS15 FAILURE DESCRIPTION:

PLUG THREADS INSIDE BODY DAMAGED DURING REMOVAL -

REPLACE SOLID STATE PROTECTION SYSTEM TRAIN "A" FAILURE DESCRIPTION:

OUTPUT TEST READS LOW -

INVESTIGATE 11 AUXILIARY FEEDWATER PUMP FAILURE DESCRIPTION:

MOTOR SLINGER NOT SLINGING -

INVESTIGATE 13 REACTOR COOLANT LOOP FAILURE DESCRIPTION:

FLOW CHANNEL 2 READS 18% WITH NO LOOP FLOW -

INVESTIGATE 12 AUXILIARY FEEDWATER PUMP FAILURE DESCRIPTION:

ERRONEOUS INDICATION -

INVESTIGATE VALVE 13SJ54 FAILURE DESCRIPTION:

VALVE OFF NORMAL INDICATION DID NOT CLEAR -

INVESTIGATE VALVE 12MS10 FAILURE DESCRIPTION:

VALVE FAILED TO FULLY CLOSE -

TROUBLESHOOT VALVE 11BF40 FAILURE DESCRIPTION:

VALVE POSITION WILL NOT REACH 10'0% OPEN, IT WILL ONLY REACH 95%

INVESTIGATE VALVE 13BF40 FAILURE DESCRIPTION:

VALVE DOES NOT REACH THE OPEN LIMIT -

REWORK

10,CFR.50. 59 EVALUATIOI MdNTH: -

JANUARY 1994 DOCK' NO:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

50-272 SALEM 1 FEBRUARY 10, 1994 R. HELLER (609)339-5162 The following items were evaluated in accordance with the provisions of the Code of Federal Regulations 10CFR50.59.

The Station Operations Review Committee has reviewed and concurs with these evaluations.

ITEM A.

Design Change Packages lEC-3208 Pkg 2

SUMMARY

11.salem Fire Damper Upgrade" - The design scope for this package includes the replacement, relocation and/or modification of existing fire dampers of Unit l's Auxiliary Building Ventilation (ABV)

Containment Purge System.

The function, basic configuration and operation of the system will not be altered and the codes, standards, qualification and design criteria of the original system will apply.

Fire dampers lABF-016 and lABF-024 will be modified in place in accordance with the results of the manufacturer's (PREFCO) fire test report recommendations to obtain a 1.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> fire rating.

The existing fire protective coating will not be necessary, and later replaced to facilitate damper modification.

Fire dampers lABF-222 and lABF-228 will be replaced with new Ruskin 1.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> rated fire damper and moved into the fire barrier, eliminating the need for existing fire protective coatings.

The reason for this change is to abide by the PSE&G commitment to the NRC and compliance with the requirements to 10CFR50, Appendix R.

The margin of safety is not reduced because we are merely enhancing the Fire Protection System to meet the criteria of 10CFR50, Appendix "R".

These modifications will not reduce the margin of safety for the Auxiliary Building Ventilation System or the Fire Protection System.

(SORC 94-008)

\\

' \\

10~FR50.59 EVALUATIO' MdNTH: -

JANUARY 19~4 (cont'd)

ITEM DOCK' NO:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

SUMMARY

50-272 SALEM 1 FEBRUARY 10, 1994 R. HELLER (609)339-5162 B.

Procedures and Revisions NC.NA-AP.ZZ-0027(Q)

"Inservice Inspection Program" -

The revision summary is as follows:

1.) This is a Limited Revision; 2.) The following technical changes was made at Step 5.4:

Deleted requirement for SORC review of ISI program submittals to the NRC; 3.) The following minor, editorial changes were made to reflect the recent organization changes: a.) Changed "Nuclear Services" to "Nuclear Support and Services; b.) Changed "Site Services" to "Reliability and Assessment."; c.) Added "Manager Planning and Scheduling (Salem only)", and d.) Step 5.7.2:

Changed history file location.

4.)

Procedure was reformatted to comply with requirements of NC.NA-AP.ZZ-0032(Q) and NC.NA-AS.ZZ-0001.

5.)

Revision bars were not used for typographical errors.

6.)

This revision meets the biennial review requirements of NC.NA-AP.ZZ-0032(Q).

The Salem and Hope Creek Technical Specifications were reviewed, including Sections 4.0 and 6.0.

The Technical Specification review did not uncover any inconsistencies with this procedure revision.

Therefore, the proposal can not change the margin of safety as defined in the basis for any Technical Specification.

(SORC 94-008)

10.c;,:FRSO... 59. EVALUATION' M~NTH: -

JANUARY 1994 (cont'd)

ITEM DOCK.NO:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

SUMMARY

50-272 SALEM 1 FEBRUARY 10, 1994 R. HELLER (609)339-5162

c.

Temporary Modifications T-Mod 94-006 "Installation of Temporary Space Heaters" - This T-Mod will provide additional necessary heating to the Unit 1 Auxiliary Feedwater Storage Tank and Refueling Water Storage Tank level instrumentation lines to prevent these instrument and sample lines from freezing.

The T-Mod will install a temporary enclosure heated by space heaters.

The temporary enclosure will be constructed of scaffold material enclosed by Herculite.

The existing heat trace system is not adequate for the present cold spell at Salem Station.

This T-Mod will be monitored hourly by Maintenance when the temporary heaters are in service, and removed when weather conditions permit.

There is no reduction in the margin of safety as defined in the basis for any Technical Specification.

(SORC 94-007)

D.

Deficiency Report (Use-As-Is)

SMD 94-009 "Operability of the 11, 12, 13 and 14 GB4 Valves" The 11, 12, 13 and 14 GB4 Valve actuator diaphragms may have reduced reliability due to a manufacturing defect with the actuators and a procedure error.

The manufacturing error results in the diaphragm being compressed in the area of the bolt circle which may result in the diaphragm tearing.

The procedure error addresses the torque value specified in procedure SC.IC-PM.ZZ-0003(Q) and results in the actuator lid bolting being torqued to a value double that recommended by the vendor.

This may aggravate the manufacturing defect in tearing the diaphragms along the bolt circle.

The GB-4 valves are air operated valves.

The valves provide containment isolation for the Steam Generator Blowdown System.

A diaphragm failure of this type will result in a tear along the bolt hole circle where the actuator lids and diaphragm are bolted together.

This would result in the valve being unable to maintain an open position and would result in the valve closing.

Since the valve is a spring assist to close valve and valve closure is based on the spring assist

109FR50.* 59 EVALUATIO,,

MONTH: -

JANUARY 1994 (cont'd)

ITEM DOCK. NO:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

SUMMARY

50-272 SALEM 1 FEBRUARY 10, 1994 R. HELLER (609)339-5162 and evacuation of air from under the actuator diaphragm, the safety function of the valve to close is not affected.

Loss of blowdown, in itself, is not a concern and is governed by chemistry concerns if blowdown is unavailable for long periods of time.

The Technical Specification requirements for the GB-4 valves are to provide containment isolation.

The failure of the diaphragm valve will result in the valve failing closed.

The ability to satisfy the Technical Specification requirements is not affected during the time that the diaphragm fails since the ability of the valve to close is based on the spring assist and actuator air evacuation from under the diaphragm.

There is no reduction in the margin of safety as defined in the basis for any Technical Specification.

(SORC 94-008)

SALEM UNIT NO. 1 SALEM GENERATING STATION MONTHLY OPERATING

SUMMARY

UNIT 1 JANUARY 1994 The Unit began the period shutdown for the eleventh refueling outage.

The Unit entered Mode 2 "Hot Standby" on January 24, 1994.

Low Power Physics Tests were completed on January 25, 1994 and preparations for increasing power to Mode 1, "Power Operation" were performed.

A Reactor Trip occurred on January 27, 1994, due to Lo-Lo Level in #14 Steam Generator.

The reactor achieved criticality on January 30, 1994, and preparation for increasing power continued throughout the remainder of the period.

RE~UELING INFORMATION~

MONTH: -

JANUARY 1994 MONTH JANUARY 1994 DOCK.NO:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

1.

Refueling information has changed from last month:

YES X

NO

2.

Scheduled date for next refueling:

MARCH 4, 1995 50-272 SALEM 1 FEBRUARY 10, 1994 R. HELLER (609)339-5162

3.

Scheduled date for restart following refueling:

MAY 2. 1995

4.

a)

Will Technical Specification changes or other license amendments be required?:

YES NO NOT DETERMINED TO DATE X

b)

Has the reload fuel design been reviewed by the Station Operating Review Committee?:

YES NO X

If no, when is it scheduled?:

MARCH 1995

5.

Scheduled date(s) for submitting proposed licensing action:

N/A

6.

Important licensing considerations associated with refueling:

7.

Number of Fuel Assemblies:

a.

Incore 193

b.

In Spent Fuel Storage 732

8.

Present licensed spent fuel storage capacity:

1170 Future spent fuel storage capacity:

1170

9.

Date of last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity:

September 2001 8-1-7.R4