Advises That Util 930610 Response to NRC Bulletin 93-02, Debris Plugging of Emergency Core Cooling Suction Strainers Acceptable
ML18100A686
Person / Time
Site: Salem, Hope Creek  
Issue date: 10/25/1993
From: Stone J
Office of Nuclear Reactor Regulation
To: Miltenberger S
Public Service Enterprise Group
References
IEB-93-002, IEB-93-2, TAC-M86571, TAC-M86610, TAC-M86611, NUDOCS 9311040123
Download: ML18100A686 (4)


Text

.. -1.-"!* ~Docket Nos. 50-272, 50-311, and 50-354 October 25. 1993 e

(

Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NOS. l & 2 AND HOPE CREEK GENERATING STATION; RESPONSE TO NRC BULLETIN 93-02, "DEBRIS PLUGGING OF EMERGENCY CORE COOLING SUCTION STRAINERS" {TAC NOS. M86610, M86611, M86571)

This letter acknowledges receipt of your response dated June 10, 1993, to NRC Bulletin 93-02, "Debris Plugging of Emer~ency Core Cooling Suction Strainers."

The bulletin was issued May 11, 1993, to all nuclear power reactor licensees.

It requested licensees to identify fibrous material in the primary containment, take any necessary compensatory measures, and remove any such material.

Your response stated-that fibrous filter material, such as described in the bulletin, was identified as being installed in the Containment Fan Coil Units {CFCUs) and the Containment Iodine Removal Units

{CIRUs) in the Salem l and 2 containments. However, you determined that the

  • fibrous filter material was adeq~at~ly contained within the CFCUs and CIRUs and the material would be highly unlikely to be dislodged in the event of a loss-of-coolant accident. Therefore, the material was left in place.. No fibrous filter material was found stored in either of the Salem containments.

For Hope Creek, your response stated that no fibrous filter material, such as.

described in the bulletin was identified as being used or stored in the containment.

Based on the above discussion, we consider your actions for Salem l and 2 and Hope Creek, to be complete.

Please retain any records of your aGtions in response to this bulletin, as subsequent inspection activities may be conducted in regard to. this issue.

Should you have any questions, please contact me at {301) 504-1419 or the Lead Project Manager for this issue, John B. Hickman, at {301) 504-3017.

9311040123 931025~~

PDR ADOCK 05000272

  • G.,

cc: See next page DI STR IBUTI ON :

c~ Docket-Ti re*- -

.. -.- -- -- --- - l NRC & Local PDRs SVar a OFFICE PDI-2: LA DATE JD I f 1~3

/jCalvo

/

/ LNicholson MO'Brien 2 OFFICIAL RECORD COPY FILENAME: A:\\SA86610.GEN Sincerely,

/SI James C. Stone, Senior Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

~a~o;i~ t;i~~ft! m; ~~~~~~~

f!~traf:W lil ~sU ~\\!l ~ i~l'!ll1 JStone JHickman/RBarrett OGC ACRS { 10)

EWenzinger, R-I JWhite, R-I

-(

,1 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

October 25. 1993

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 & 2 AND HOPE CREEK GENERATING STATION, RESPONSE TO NRC BULLETIN 93-02, "DEBRIS PLUGGING OF EMERGENCY CORE COOLING SUCTION STRAINERS" (TAC NOS. M86610, M86611, M86571)

This letter acknowledges receipt of your response dated June 10, 1993, to NRC Bulletin 93-02, "Debris Plugging of Emergency Core Cooling Suction Strainers."

The bulletin was issued May 11, 1993, to all nuclear power reactor licensees~

It requested licensees to identify fibrous material in the primary containment, take any necessary compensatory measures, and remove any such material.

Your response stated that fibrous filter material, such as described in the bulletin, was identified as being installed in the Containment Fan Coil Units (CFCUs) and the Containment Iodine Removal Units (CIRUs) in the Salem 1 and 2 containments.

However, you determined that the fibrous filter material was adequately contained within the CFCUs and CIRUs and the material would be highly unlikely to be dislodged in the event of a loss-of-coolant accident. Therefore, the material was left in place.

No fibrous filter material was found stored in either of the Salem containments.

For Hope Creek, your response stated that no fibrous filter material, such as described in the bulletin was identified as being used or stored in the containment.

Based on the above discussion, we consider your actions for Salem 1 and 2 and Hope Creek, to be complete.

Please retain any records of your actions in response to this,:bulletin, as subsequent inspection activities may be conducted in regard to this issue.

Should you have any questions, please contact me at (301) 504-1419 or the Lead Project Manager for this issue, John B. Hickman, at (301) 504-3017.

cc:

See next page Sincerely,

~c~

James C. Stone, Senior Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Mr. Steven E. Miltenberger Public Service Electric & Gas Company cc:

Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street NW Washington, DC 20005-3502 Richard Fryling, Jr., Esquire Law Department - Tower SE 80 Park Place Newark, NJ 07101 Mr. Calvin A. Vondra General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. J. Hagan Vice President - Nuclear Operations Nuclear Department

  • P.0. Box 236 Hancocks Bridge, New Jersey 08038 Mr. Charles S. Marschall, Senior Resident Inspector Salem Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental

. Protection.and Energy CN 415 Trenton, NJ 08625-0415 Maryland People's Counsel American Building, 9th Floor 231 East Baltimore Street Baltimore, Maryland 21202 Mr. J. T. Robb, Director Joint Owners Affairs Philadelphia Electric Company 955 Chesterbrook Blvd., 51A-13 Wayne, PA 19087 Salem Nuclear Generatin~ Station, Units 1 and 2, and Hope Creek Generating Station Richard Hartung Electric Service Evaluation Board of Regulatory Commissioners 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157

-Hancocks Bridge, NJ 08038 Mr. Frank X. Thomson, Jr., Manager*'

Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Mr. J. A. Isabella MGR. - Generation Department Atlantic Electric Company P.O. Box 1500 1199 Black Horse Pike Pleasantville, NJ 08232 Carl D. Schaefer External Operations - Nuclear Delmarva Power & Light Company P.0. Box 231 Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division ATTN:

Chief Engineer 231 E. Baltimore Street Baltimore, MD 21202-3486

    • J..

Mr. Steven E. Miltenberger Public Service Electric & Gas Company cc:

Hope Creek Resident Inspector U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, New Jersey 08038 Mr. R. Hovey General Manager - Hope Creek Operations Hope Creek Generating Station P.O. Box 236 Hancocks Bridge, New Jersey 08038 Salem Nuclear Generating Station, Unit 1 and 2, and Hope Creek Generating Station Mr. S. LaBruna Vice President - Nuclear Engineering Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038