ML18100A591

From kanterella
Jump to navigation Jump to search

Forwards SE Concluding That Notrum Code Can Be Used to Demonstrate Compliance W/Requirements in 10CFR50.46 for Plant
ML18100A591
Person / Time
Site: Salem  
Issue date: 08/25/1993
From: Stone J
Office of Nuclear Reactor Regulation
To: Miltenberger S
Public Service Enterprise Group
Shared Package
ML18100A592 List:
References
TAC-M86144, TAC-M86145, NUDOCS 9309090440
Download: ML18100A591 (3)


Text

Docket Nos. 50-272 and 50-311 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

August 25, w

SUBJECT:

SMALL BREAK LOSS OF COOLANT ACCIDENT NOTRUMP ANALYSIS METHODOLOGY, SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2 (TAC NOS. M86144 AND M86145)

By letter dated April 2, 1993, Public Service Electric and Gas Company (PSE&G) submitted the Small Break Loss of Coolant Accident (LOCA) Analysis Report (WCAP-13657).

WCAP-13657 incorporates the NOTRUMP analysis methodology for use at Salem, Units 1 and 2.

The evaluations described in the report were performed in support of the Salem Fuel Upgrade and Margin Recovery Project.

The NRC staff has reviewed the submittal and concludes that the NOTRUMP code can be used to demonstrate compliance with the requirements in 10 CFR 50.46 for Salem, Units 1 and 2.

A copy of our safety evaluation is enclosed.

Enclosure:

Safety Evaluation cc w/enclosure:

See next page DI STR IBUTI ON Docket* File NRC & Local PDRs PDI-2 Reading SVarga JCalvo MBoyle OFFICE Sincerely,

/Sf James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation 270062.

JStone JZimmerman MO' Brien

EWenzinger, RGN-I PDI-2/PE JStone

~ /~0/93 JWhite, RGN-I SBrewer PDI-2/D MBoyl e #\\

~1i~/93 OFFICIAL RECORD COPY DOCUMENT NAME:

SA86144.GEN

~

UNITED STATES NUCLEAR RE~ULATORY COMMISSION WASHINGTON, D.C. 20555--0001 Docket Nos. 50-272 and 50-311 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

August 25, 1993

SUBJECT:

SMALL BREAK LOSS OF COOLANT ACCIDENT NOTRUMP ANALYSIS METHODOLOGY, SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2 (TAC NOS. M86144 AND M86145)

By letter dated April 2, 1993, Public Service Electric and Gas Company (PSE&G) submitted the Small Break Loss of Coolant Accident (LOCA) Analysis Report (WCAP-13657).

WCAP-13657 incorporates the NOTRUMP analysis methodology for use ~t Salem, Units 1 and 2.

The evaluations described in the report were performed in support of the Salem Fuel Upgrade and Margin Recovery Project.

The NRC staff has reviewed the submittal and concludes that the NOTRUMP code can be used to demonstrate compliance with the requirements in 10 CFR 50.46 for Salem, Units 1 and 2.

A copy of our safety evaluation is enclosed.

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Sincerely,

~t.~

James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

' I I

Mr. Steven E. Miltenberger Public Service Electric & Gas Company cc:

Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street NW Washington, DC 20005-3502 Richard Fryling, Jr., Esquire Law Department-- Tower SE 80 Park Place Newark, NJ 07101 Mr. Calvin A. Vondra General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. J. Hagan Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Mr. Thomas P. Johnson, Senior Resident Inspector Salem Generating Station U.S. Nuclear Regulatory CommissiOn Drawer I Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Maryland People's Counsel American Building, 9th Floor 231 East Baltimore Street Baltimore, Maryland 21202 Mr. J. T. Robb, Director Joint Owners Affairs Philadelphia Electric Company 955 Chesterbrook Blvd., 51A-13 Wayne, PA 19087 Salem Nuclear Generating Station, Units 1 and 2 Richard Hartung Electric Service Evaluation Board of Regulatory Commissioners 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Frank X. Thomson, Jr., Manager Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Mr. J. A. Isabella MGR. - Generation Department Atlantic Electric Company P.O. Box 1500 1199 Black Horse Pike Pleasantville, NJ 08232 Carl D. Schaefer External Operations - Nuclear Delmarva Power & Light Company P.0. Box 231 Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division ATTN:

Chief Engineer 231 E. Baltimore Street Baltimore, MD 21202-3486