ML18096B128

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-272/92-18 & 50-311/92-18 on 921116-17. No Violations Noted
ML18096B128
Person / Time
Site: Salem  
Issue date: 11/27/1992
From: Joyner J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Miltenberger S
Public Service Enterprise Group
Shared Package
ML18096B129 List:
References
NUDOCS 9212080030
Download: ML18096B128 (3)


See also: IR 05000272/1992018

Text

Docket Nos. 50-272

50-311

Mr. Steven E. Miltenberger

Vice President and Chief Nuclear Officer

Public Service Electric and Gas Company

P. 0. Box 236

Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

NOV. 27 1992

SUBJECT:

Combined Inspection Report Nos. 50-272/92-18 and 50-311/92-18

This letter refers to the safety inspection conducted by Dr. Jason C. Jang and Ms. Laurie

Peluso of this office.on November 16-17, 1992, of activities authorized by NRC License

Numbers DPR-70 and DPR-75, and to the discussions of our findings held by Dr. Jang and

Ms. Peluso with Mr. V. Polizzi and other members of your staff at the conclusion of the

inspection.

Areas examined during this inspection are described in the NRC Region* I Inspection Report

which is enclosed with this letter. Within these areas, the inspection consisted of selective

examinations of procedures and representative records~ interviews with personnel, and

observations by the inspectors.

Within the scope of this inspection, we noted that the Chemistry Department staff had

excellent knowledge of the radioactive liquid and gas~us effluent control programs. Also,

the completion of the short-term project for the radiation monitoring system* (RMS) was

noteworthy. No safety concerns or violations of regulatory requirements were identified.

No reply to this letter is requirefl. Your cooperation with us in this matter is appreciated.

~F9igned By:

James H. Joyner

James H. Joyner, Chief

Facilities Radiological Safety

and Safeguards Branch

Division of Radiation Safety

and Safeguards

Enclosure: Combined NRC Inspection Report Nos. 50-272/92:-18 and 50-311/92-18

9212080030 921127

PDR

ADOCK 05000272

G

PDR

OFFICIAL RECORD COPY

06

-*

NOV. 271992

Public Service Electric & Gas

2

cc w/encl:

S. LaBruna, Vice President, Nuclear Operations

C. Schaefer, External Operations - Nuclear, Delmarva Power & Light Co.

C. Vondra, General Manager - Saiem Operations

F. Thomson, Manager, Licensing and Regulation

L. Reiter, General Manager - QA and Nuclear Safety Review

  • J. Robb, Director, Joint Owner Affairs

A. Tapert, Program Administrator

- R. Fryling, Jr., Esquire

M. Wetterhahn, Esquire

J. Isabella, Director, Generation Projects Department,

Atlantic Electric Company

Consumer Advocate, Office of Co_nsumer Advocate

Tom Dwyer, Public Safety Consultant, Lower Alloways Creek Township

K. Abraham, PAO (2)

Public Document Room (PDR)

Local Public Docum_ent Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New Jersey

OFFICIAL RECORD COPY

NOV. 27 1992

Public Service Electric & Gas

3

  • bee *w /encl:

Region .I Docket Room (with concurrences).

E. Wenzinger, DRP

J. White, DRP

. J. Stone, NRR

S. Dembek, NRR .

V. Mccree, OEDO

DRSS:RI

JANG 11/ ~ f'lg2

DRSS:RI

DRSS:RI

DRSS:RI

PELUSO l 1/o2fi92

l\\.11LLER 11/:Af /92

JOYNER 11/t. "7 /92

OFFICIAL RECORD COPY