Docket *Nos.

50-272

50-311

50-354

Public Service Electric ami Gas Company

ATTN: Mr. S. E. Miltenberger

. Vice President and Chier Nuclear Officer

P.O. Box 236

Han.cocks Bridge, NJ 08038

Gentlemen:

. Subject: NRC _Insp.ection Nos. 50-272/92-01; 50-3fl/92-01; 50-354/92-:-01

This letter transmits the findings of an inspection to assure public health and safety,

conducted by the .resident inspector staff including Mr. T. Johnson and others from

Deeember 29, 1991 tO February 8, i992 at the Salem and Hope Creek Nuclear Generating

Stations. The findings were discussed .. with Mr. C. Vondra and Mr. S. Funsten of your staff.*

Within the scope of this inspection, the inspectors did not find any vi,olations. No reply to

this.letter is required.-

As discussed. in the enclosed report,* a number of engineering design and installation issues.

were identified* by your staff during this inspection p~riod and remain unresolved. While the

. identification of these items is indicative of a good questioning_ attitude and attention to detail,

.action should be taken to assure timely resolution of this matter.

Your cooperation with us is appreciated .

.

Sincerely,

A. Randolph Blough, Chief

Projects Branch No. 2

Division of Reactor Projects

Enclosure:

NRC Inspection Report Nos. 50-272/92-01; 50~311/92-01; 50-354/92-01

9203100196 920302

PDR

ADOCK 05000272

G

PDR

Public Service Electric

and Gas Company

cc w/encl:

2

S. LaBruna, Vice President - Nuclear Operations

C. Vondra, General Manager, Salem *Operations

/1. *Hagan, General Manager, Hope Creek Operations

C. Schaefer, External Operations - Nuclear, Delmarva Power & Light Co.

F. *Thomson, Manager, Licensing and Regulation

J. Robb, Director, Joint Owner Affairs

A. Tape!t, Program Administrator

L. Reiter; General Manager, QA and Nuclear Safety Review

M. Wetterhahn, Esquire

R. Fryling, Jr., Esquire

.

.

J. Isabella1 Director, Generation Projects Department, Atlantic Electric D. Wersan, Assistant

D. Wersan, Assistant Consumer Advocate, Office of Consumer Advocate

/J. Lipoti, State of New Jersey

Lower Alloways Creek Township

K. Abraham, PAO

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New Jersey

Public Service Electric

and Gas Company

bee w/encl:

Region I Docket Room (with concurren_ces)

Management Assistant, DRMA (w/o encl)

J. Joyner, DRSS

R. Blough, DRP

J. White, DRP

J. Stone, NRR

S. Dembek, NRR

B. Norris, DRP

L. Cheung, DRS

DRS SALP Coordinator

DRSS SALP Coordinator

R. Lobel, EDO

C. Miller, PDI-2, NRR

bee w/letter and Executive Summary Only:

W. Hehl, DRP

J. Wiggins, DRP _

W. Hodges, DRS

W. Lanning, DRS

J. Durr, DRS

L. Bettenhausen, DRS

M. Knapp, DRSS

,/)l><_'f *

D~&'

J. R.lwh te

Ii I

~/92

3 '

(~

\\/

\\DRP_:RI

A. R. Blough

_J> I '</92