August 7, 1991 Docket No. 50-272 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038
Dear Mr. Miltenberger:
DISTRIBUTION:
Docket File NRC & Local PDRs PDI-2 Reading SVarga JCalvo WButler M0 1Brien(2)
JS tone OGC EJordan, 3701 ACRS(lO)
NBLe, 14B-20 RPerch, 8H-3 RBlough, RGN-I JWhite, RGN-I
SUBJECT:
WITHDRAWAL OF CLOSEOUT OF BULLETIN 90-01, 11 LOSS OF FILL-OIL IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT 11
, SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 76605)
Your letter dated July 18, 1990, responded to Bulletin 90-01 for the Salem and Hope Creek Nuclear Generating Stations. Your response stated that Salem Unit 1 does not have any Rosemount transmitters from the manufacturing lots identified by Rosemount as having a high failure rate due to loss of fill-oil, installed in either safety-related systems or systems installed in accordance with 10 CFR 50.62 (ATWS Rule).
The NRC letter of July 24, 1991, stated that the July 18, 1990, letter provided an adequate basis to consider NRC 1 s review to be complete. That statement did not consider the fact that Salem 1 had 117 transmitters manufactured prior to July 11, 1989, installed in safety-related systems or systems installed in accordance with 10 CFR 50.62. Because of these additional transmitters,Bulletin 90-01 cannot be closed at this time.
We regret any inconvenience this has caused.
cc:
See next page
- Previously Concurred Sincerely,
/S/
James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation OFC-- :PDr:27[--------:"Pin:27i5M-~:*PDII-I/LPM :-
- PDI-2/D
'\\ Pl NAME--~MO;B, -------~jSTONE;t1f:---:NBLE~;Ji:-----:RPERCH-~--~WBUTLER--\\:J"-"
. d-..... ---------. ----*----------. -**------------. --------------. --------------
DATE
- "\\;]/
/91
- %""I~ /91
- 08/05/91
- '8!7 /91
- ~I i/91
OFF1CT7i:l-fH'.CORIT-ccwv--------------------------------*
Document Name:
- ~
9108140068 910007
'\\
PDR ADOCK 05000272 Q
PDR 090038 J)Fo i l \\ c)
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 August 7, 1991 Mr. Steven E. Miltenberger Vice President and Chief Nucl~ar Officer Public Service Electric and Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038
Dear Mr. Miltenberger:
SUBJECT:
WITHDRAWAL OF CLOSEOUT OF BULLETIN 90-01, "LOSS OF FILL-OIL IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT, SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 76605)
Your letter dated July 18, 1990, responded to Bulletin 90-01 for the Salem and Hope Creek Nuclear Generating Stations~ Your response stated that Salem Unit 1
- does not have any Rosemount transmitters from the manufacturing lots identified by Rosemount as having a high failure rate due to loss of fill-oil, installed in either safety-related systems or systems installed in accordance with 10 CFR 50.62 (ATWS Rule).
The NRC letter of July 24, 1991, stated that the July 18, 1990, letter provided an adequate basis to consider NRC's review to be complete. That statement did not consider the fact that Salem 1 had 117 transmitters manufactured prior to July 11, 1989, installed in safety-related systems or systems installed in accordance with 10 CFR 50.62. Because of these additional transmitters,Bulletin 90-01 cannot be closed at this time.
We regret any inconvenience this has caused.
cc:
See next page Sincerely,
~-~tol!::Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
~
.J-.,
I
'\\..,.
\\..),
i Mr. Steven E. Miltenberger Public Service Electric & Gas Company cc:
Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street NW Washington, DC 20005-3502 Richard Fryling, Jr., Esquire Law Department - Tower 5E 80 Park Place Newark, NJ 07101 Mr. Calvin A. Vondra General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. S. LaBruna Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Mr. Thomas P. Johnson, Senior Resident Inspector Salem Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Dr. Jill *Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection CN 415 Trenton, NJ 08625-0415 Maryland People's Counsel American Building, 9th Floor 231 East Baltimore Street Baltimore, Maryland 21202 Mr. J. T. Robb, Director Joint Owners Affairs Philadelphia Electric Company 955 Chesterbrook Blvd., 51A-13
.Wayne, PA 19087 Salem Nuclear Generating Station Richard B. McGlynn, Commission Department of Public Utilities State of New Jersey 101 Commerce Street
- Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Frank X. Thomson, Jr., Manager Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA* 17120 Mr. Scott B. Ungerer MGR. - Joint Generation Projects Atlantic Electric Company P.O. Box 1500 1199 Black Horse Pike Pleasantville, NJ 08232 Mr. Jack Urban General Manager, Fuels Department Delmarva Power & Light Company 800 King Street Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division ATTN:
Chief Engineer 231 E. Baltimore Street
. Baltimore, MD 21202-3486