TABLE 4,3-13 !Continued)

TABLE NOTATION

( 1)

The CHANNEL FUNCTIONAL TEST shall also demonstrate tnat automatic isolation of this pathway and control roo~

alarm annunciation occurs if any of the following conditions exist:

1.

Instrument indicates measured levels above the alarm/trip setpoint.

2.

Circuit failure.

(Loss of Power).

3.

(2) demonstrate that control room alarm annunciation occurs i~ any of the following conditions exist:

1.

Instrument indicates 1TP.asured levels above the alarm/trip setpoint.

2. Circuit failure.

(Loss of Power)

3. _...!.,~~~~~~~~~~~~=--.:.~~~
4.

~I~~~:_.::~~~~~~-!..!.!--~~~

OA I (3)

The initial CHANNEL CALIBRATION was performed using appropriate liq~id or gaseous calibration sources obtained from reputable suppliers. The activity of the calibration sources were reconfirmed using a multi-channel analyzer which was calibrated using one or more NBS standards.

(4)

The CHANNEL CALIBRATION shall include the use of standard gas samples containing a nominal:

1 *. One volume percent oxygen, balance nitrogen, and

2.

Four volume percent oxygen, balance nitrogen.

  • At al 1 times

'*During waste gas holdup system.operation.

      • During containment purge or containment pressure -

vacuum relief.

SALEt UNIT l 9001310530 900122 PDR A:OOC:I< 0500~E1t?

p 3/4 3-69.

Amendment No. 79