Forwards Revised Pages for 890623 Application for Amend to Licenses DPR-70 & DPR-75.Revised Pages Will Include Footnote to Identify That 1 Hr Thermal Soak Time Allowable at Power Levels Less than 50% Prior to Using Analog Rod Position
ML18094A447
Person / Time
Site: Salem  PSEG icon.png
Issue date: 05/22/1989
From: Miltenberger S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18094A448 List:
References
NLR-N89075, NUDOCS 8905310122
Download: ML18094A447 (2)


Text

..

Public Service Electric and Gas Company Steven E. Miltenberger Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4199 Vice President and Chief Nuclear Officer May 22, 1989 NLR-N89075 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

REQUEST FOR AMENDMENT SALEM GENERATING* STATION UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 Attached are revised pages for License Change Request (LCR 88-01), previously submitted via PSE&G letter NLR-N88083, dated June 23, 1988. The proposed changes are being submitted based upon the recommendation of Mr. Jim stone, NRC Licensing Project Manager.

The affected pages are being revised to include a footnote to identify that a one hour thermal "soak time" is allowable at power levels less than 50% prior to using the analog rod position indicators. "Soak time" refers to the time period which begins upon the completion of rod motion, to allow thermal equilibration to take place. This footnote'will alleviate the concern that PSE&G expressed in LCR 88-01 but maintain the intent behind LCR 85-12, which originally added the erroneous phrase "within one hour". Below 50% power the analog rod position indicators are susceptible to drift due to thermal transients. License Change Request 85-12 was originally submitted to address this problem.

Above 50% power levels rod motions are expected to be small and are not expected to induce significant thermal transients in the analog rod position channels. These proposed revisions are_

consistent with those proposed and approved for the Beaver Valley Power station, Unit 1. The proposed changes do not affect the previously submitted No Significant Hazards Consideration LCR 88-01.

I:

Document Control Desk 2 05-22-89 NLR-N89075 Should you have any questions, please do not hesitate to contact us.

Sincerely, Attachment C Mr. J. c. Stone Licensing Project Manager Ms. K. Halvey Gibson Senior Resident Inspector Mr. W. T. Russell, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 .

Trenton, NJ 08625