Monthly Operating Rept for Aug 1988 for Salem Unit 2
ML18093B184
Person / Time
Site: Salem 
Issue date: 08/31/1988
From: Jackson J, Miller L, White P
Public Service Enterprise Group
To:
References
NUDOCS 8810040158
Download: ML18093B184 (13)


Text

Completed by Pe 1 1 Month AUGUST 1988 AVERAGE DAILY UNIT POWER LEVEL White Docket No.

Unit Name Date Telephone Extension Day Average Daily Power Level Day Average Daily (MWe-NET) 1 517 2

950 3

931 4

936 5

93 8 6

933 7

928 8

903 9

899 1 0 877 11 902 12 877 13 851 14 847 15 891 1 6 784 Pg. 8.1-7 Rl (MWe-NET) 17 821 18 812 19 806 20 817 21 799 22 790 23 775 24 759 25 743 26 754 27 745 28 735 29 704 30 738 31 134

~LE-2(;

J~

50-311 Salem # 2 9-8-88 609-935-6000 4451 Power Level

e OPERATING DATA REPORT 50-311 9-8-88 Docket No.

Date Telephone Extension 935-6000 Completed by Pell White Operating Status Unit Name Salem No. 2 Notes Reporting Period August 1988 Licensed Thermal Power (MWt) 3411 Nameplate Rating (Gross MWe) 1170 Design Electrical Rating (Net MWe) 1115 Maximum Dependable Capacity(Gross MWe)1149 Maximum Dependable Capacity (Net MWe) 1106 4451

1.

2

  • 3 *
4.

5

  • 6.

7 *

8.

If Changes Occur in Capacity Ratings (items 3 through 7) since Last Report, Give Reason N/A

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

9.

Power Level to Which Restricted, if any (Net MWe)

N/A

~~~~~~~~~~~~

10. Reasons for Restrictions, if any N/A

~---'~~~~~~~~~~~~~~~~~~~~

11. Hours in Reporting Period
12. No. of Hrs. Reactor was Critical
13. Reactor Reserve Shutdown Hrs.
14. Hours Generator On-Line
15. Unit Reserve Shutdown Hours
16. Gross Thermal Energy Generated (MWH)
17. Gross Elec. Energy Generated This Month 744 72 5. 9 0

720.5 0

2012440.8 Year to Date 5855 5688.6 0

5633.7 0

18464736 Cumulative 60360 38051.5 0

36915.5 0

64115257 (MWH) 603350 6084970 37714440

18. Net Elec. Energy Generated (MWH) 597546 5826660 35846038
19. Unit Service Factor 96.8 96.2 61.2
20. Unit Availability Factor 96.8 96.2 61.2
21. Unit Capacity Factor

(:using MDC Net) 72.6 89.9 53.7

22. Unit Capacity Factor (using DER Net) 72.0 89.3 53.3
23. Unit Forced Outage Rate 3.2 3.8 27.9
24. Shutdowns scheduled over next 6 months (type, date and duration of each)

Refueling Outage starting Sept. 2, 1988 and lasting for approximately 52 days.

25. If shutdown at end of Report Period, Estimated Date of Startup:

Unit 2 currently in its 4th refueling outage.

Schedule startup Oct. 26, 1988 8-l-7.R2

Completed by No.

Date 0174 8-01-88 0179 8-02-88 0187 8-06-88 0193 8-10-88 0195 8-12-88 0196 8-12-88 0198 8-14-88 0199 8-15-88 0200 8-16-88 0201 8-17-88 0202 8-18-88 0204 8-18-88 0 205 8-20-88 1

F: Forced S: Scheduled UNIT SHUTDOWN AND POWER REDUCTIONS REPORT MONTH AUGUST 1988 Docket No.

Unit Name Date Telephone Extension 50-311 Salem No.2 Pell White Type 1

F s

s s

s s

s s

s s

s s

s Duration Hours 5.40 3.82 3.93 48.75 10.75 28.77 24.98 28.17 27.58 13.50 19.50 48.83 50.68 Reason 2

A H

H H

H H

H H

H H

H H

H Method of Shutting Down Reactor 3

5 5

5 5

5 5

5 5

5 5

5 5

License Event Report 2 Reason A-Equipment Failure-explain B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & Licensing Exam F-Administrative G-Operational Error-explain H-Other-explain System Code 4 EB RC RC RC RC RC RC RC RC RC RC RC RC 3 Method 1-Manual Component Cod-e 5 TRAN SF FUELXX FUELXX FUEL XX FUELXX FUEL XX FUEL XX FUEL XX FUEL XX FUEL XX FUEL XX FUEL XX FUELXX 2-Manual Scram.

3-Automatic Scram.

4-Continuation of Previous Outage 5-Load Reduction 9-0ther 4

August 4, 1988 609-935-6000 4451 Cause and Corrective Action to Prevent Recurrence "C" Vital Instrument Bus Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Nuclear Core Coast Down Exhibit G 5

Exhibit Instructions for Prepara-tion of Data Entry Sheets for Licensee Event Report (LER) File (NUREG 0161)

Salem as Source

1 UNIT SHUTDOWN AND POWER REDUCTIONS Docket No. 50-311 REPORT MONTH AUGUST 1988 Unit Name Salem No.2

  • Date August 4' 1988 Completed by Pell White Telephone 609-935-6000 Extension 4451 Method of Duration Shutting License Cause and Corrective No.

Date Type Hours Reason Down Event System Component Action to 1

2 Reactor Report Code 4 Code 5 Prevent Recurrence Nuclear -Core 0 210 8-23-88 s

34.23 H

5 RC FUELXX Coast Down Nuclear Core 0211 8-24-88 s

19.75 H

5 RC FUELXX Coast Down Nuclear Core -

0212 8-25-88 s

2.82 H

5 RC FUELXX Coast Down Nuclear Core 0213 8-25-88 s

4.18 H

5 RC FUEL XX Coast Down Nuclear Core 0214 8-25-88 s

30.83 H

5 RC FUELXX Coast Down Nuclear Core 0217 8-26-88 s

34.17 H

5 RC FUEL XX Coast Down Nuclear Core 0 219 8-28-88 s

29.50 H

5 RC FUELXX Coast Down Nuclear Core 0220 8-29-88 s

42.40 H

5 RC FUELXX Coast Down Rx Trip 0 222 8-31-88 F

18.10 A

3 HH VALVEX SG LVL 23BF19

WO NO 870909070 880122112 880122148 880601153 880711082 PSE&G SALEM GENERATING STATION SAFETY RELATED WORK ORDER LOG SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2

22MS119 FAILURE DESCRIPTION:

REMOVE INSULATION.

INVESTIGATE AND REPAIR LEAK.

2 2CV63 FAILURE DESCRIPTION:

CHECK VALVE DOES NOT CLOSE/REPAIR/FA-33.

2 FUEL TRANS WINCH FAILURE DESCRIPTION:

REPLACE BRAKE PARTS 2

2S27C FAILURE DESCRIPTION:

22 CHG. PUMP CLR. OUTLET PIPE LEAK/REPLACE.

2 2SW218 FAILURE DESCRIPTION:

DOWNSTREAM FLANGE LEAK/REPAIR.

SALEM UNIT 2 WO NO UNIT EQUIPMENT IDENTIFICATION 880718148 2

2BR39 FAILURE DESCRIPTION:

DIAPHRAGM LEAK/REPLACE/MARK NO. M-61.

880720054 2

2BR172 FAILURE DESCRIPTION:

SPINDLE SHAFT BROKEN OFF/REPLACE.

880726154 2

2S27C FAILURE DESCRIPTION:

WELD LEAK UPSTREAM OF 21SW126/REPAIR.

880726187 2

23 CHG. PUMP FAILURE DESCRIPTION:

THE HORZINAL COVER ON NUMBER 2 CYLINDER ON 23 CHARGING PUMP LEAKS/REWORK.

880727071 2

2CC216 FAILURE DESCRIPTION:

LEAKING THRU/DISASS & INSPECT/MARK NO. D-77.

WO NO 880804061 880809057 880815195 880817095 880822099 SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2

2C DIESEL GEN.

FAILURE DESCRIPTION:

TROUBLESHOOT EXCESSIVE BRUSH ARCING ON 2C DIESEL GEN.

2 2A DIESEL GEN FAILURE DESCRIPTION:

2A DIESEL WILL NOT LOAD CORRECTLY/TROUBLESHOOT.

2 22 CHILLED WTR PUMP MTR FAILURE DESCRIPTION:

TRIPPED/TROUBLESHOOT AND REWORK.

2 IN-CORE FLUX DETECT.10 PATH FAILURE DESCRIPTION~

WILL NOT OPERATE/TROUBLESHOOT.

2 2Rl3C FAILURE DESCRIPTION:

MONITOR IS FAILED/REPAIR.

WO NO 880822119 880824098 880825097 SALEM UNIT 2 UNIT

~QUIPMENT IDENTIFICATION 2

S/G BLOWDOWN FLOW CONSOLE INDICATOR 2

FAILURE DESCRIPTION:

STM GEN BLOWDN FLOW CONSOLE INDICATOR FAILED LOW/TROUBLESHOOT.

2Rl3C FAILURE DESCRIPTION:

MONITOR IS FAILED/REPAIR.

2 2FA5838 FAILURE DESCRIPTION:

23 S/G BLOWDOWN FLOW INDICATION/FAILED/

REPAIR.

MAJOR PLANT MODIF-TIONS REPORT MONTH AUGUST 1988

  • OCR NO.

PRINCIPAL SYSTEM None for this period.

Design Change Request DOCKET re:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

DESCRIPTION 50-311 Salem 2 September 10,1988 J. Jackson 609/339-4455

e I1AJOR PLANT MODIFICATIONS REPORT MONTH -

AUGUST 1988 e

DOCKET NO:

UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

DCR -

Design Change Request 50-272 Salem 2 September 10, 19 88 J. Jackson (609)339-4455

I L SALEM UNIT NO. 2 SALEM GENERATING STATION MONTHLY OPERATING

SUMMARY

UNIT 2 AUGUST 1988 The Unit was restored to operation on August 1, 1988, and continued its end-of-cycle coastdown operation.

The coastdown continued until August 31, 1988, when a reactor trip occurred due to the failure of a valve position feedback indicator linkage on a feedwater regulating valve.

The reactor trip resulted in the Unit entering its refueling/maintenance outage two days early.

REFUELING INFORMATION DOCKET NO.: 50-311 UNIT NAME: Salem 2 COMPLETED BY:

J. Jackson DATE: September 10, 1988 TELEPHONE: 609/935-6000 EXTENSION 4455 Month AUGUST 1988

1.

Refueling information has changed from last month:

YES NO X

2.

Scheduled date for next refueling:

September 2, 1988

3.

Scheduled date for restart following refueling:

October 26,1988

4.

A)

Will Technical Specification changes or other license amendments be required?

YES NO NOT DETERMINED TO DATE X

B)

Has the reload fuel design been reviewed by the Station Operating Review Committee?

YES NO X

If no, when is it scheduled?

September, 1988

5.

Scheduled date(s) for submitting proposed licensing action:

August 1988 if required

6.

Important licensing considerations associated with refueling:

NONE

7.
8.
9.

8-l-7.R4 Numqer of Fuel Assemblies:

A)

Inc ore B)

In Spent Fuel Storage Present licensed spent fuel storage capacity:

Future spent fuel storage capacity:

Date of last refueling that can be discharged to spent fuel pool assuming the present licensed capacity:

193 224

'1170 1170 March 2003

e PS~G Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Nuclear Department U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Dear Sir:

MONTHLY OPERATING REPORT SALEM NO. 2 DOCKET NO. 50-311 September 10, 1988 In compliance with Section 6.9.1.6, Reporting Requirements for the Salem Technical Specification, the original copy of the monthly operating reports for the month of August 1988 are being sent to you.

Average Daily Unit Power Level Operating Data Report Unit Shutdowns and Power Reductions Safety Related Maintenance Major Plant Modification Operating Surrnnary Refueling Information Sincerely yours, U:'.~/,ip/