Text
l\\VERAGE DAILY UNIT POWER LEVEL Completed by Pell White Month January 1988 Day Average Daily Power Level (MWe-NET) 1 1083 2
1095 3
1047 4
1051 5
1065 6
1070 ----
7 1095 8
1070 9
1059 10 1108 11 1098 12 1105 13 1104 14 1102 15 1106 ----
16 1081 Pg. 8.1-7 Rl
,,-~----
8802230098 880131
- DR ADOCK 05000311
... DCD Day Docket No.
Unit Name Date Telephone Extension Average Daily (MWe-NET) 17 1106 18 1102 19 1105 20 1102 21 1110 22 1077 23 1095 24 1111 25 1105 26 1078 27 1096 28 1107 29 10 98 30 1099 31 313 50-311 Salem # 2 February 10, 1988 609-935-6000 4451 Power Level
e OPERATING DATA REPORT I
Completed by Pell White Operating Status Docket No. 50-311
~------o--~
Date
!ebruary 10,1988 Telephone 935-6000 Extension 4451
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
Unit Name Salem No. 2 Notes Reporting Period January 1988 Licensed Thermal Power (MWt) 3411 Nameplate Rating (Gross MWe)
TT7o Design Electrical Rating (Net MWe) 1115 Maximum Dependable Capacity(Gross MWe)IT49 Maximum Dependable Capacity (Net MWe) 1106 since Last N/A If Changes Occur in Capacity Ratings (items 3 through 7)
Report, Give Reason
~-----~-~
- 9.
Power Level to Which Restricted, if any (Net MWe)
N/A
~
- 10. Reasons for Restrictions, if any N/A
- 11. Hours in Reporting Period
- 12. No. of Hrs. Reactor was Critical
- 13. Reactor Reserve Shutdown Hrs.
- 14. Hours Generator On-Line
- 15. Unit Reserve Shutdown Hours
- 16. Gross Thermal Energy Generated (MWH)
- 17. Gross Elec. Energy Generated (MWH)
- 18. Net Elec. Energy Generated (MWH)
- 19. Unit Service Factor
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (using MDC Net)
- 22. Unit Capacity Factor This Month 744 74 4 0
740.26 0
2490826 831080 798650 99.5 99.5 97.1 Year to Date 744 744 0
740.26 0
2490826 831080 798650 99.5 99.5 97.1 Cumulative 55249 33106.9 0
32022.1 0
48141347 32460550 30818028 58.0 58.0 50.4 (using DER Net) 96.3 96.3 50.0
- 23. Unit Forced Outage Rate 0.5 0.5 30.5
- 24. Shutdowns scheduled over next 6 months (type, date and duration of each)
N/A
~
- 25. If shutdown at end of Report Period, Estimated Date of Startup:
N/A 8-l-7.R2
Completed by No.
Date 017 1-31-88 018 1-31-88 019 1-31-88 0 20 1-31-88 1
F: Forced S: Scheduled T1NIT SHUTDOWN AND POWER REDUCTIONS Docket No. 50-311 REPORT MONTH JANAURY 1988 Unit Name Salem No.2 Pell White Method of Duration Shutting License Type Hours Reason Down Event 1
2 Reactor Re:eort p
9.3 B
5 F
3.7 A
1 F
3.9 A
5 F
0.3 A
5 2 Reason A-Equipment Failure-explain B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & Licensing Exam F-Administrative G-Operational Error-explain H-Other-explain Date Februarl 10,1988 v
Telephone 609-935-6000 Extension 4451 System Component Code 4 Code 5 CH TURBIN HA MECFUN CH INSTRU CH INSTRU 3 Method 1-Manual 2-Manual Scram.
3-Automatic Scram.
4-Continuation of Previous Outage 5-Load Reduction 9-0ther Cause and Corrective Action to Prevent Recurrence STEAM GENERATOR FEED PUMP TURBINE MAINTENANCE MAIN TURBINE GOVERNOR CONTROL HYDRAULIC LEAK STEAM GENERATOR -
FEED PUMP LOCAL CONTROLS STEAM. GENERATOR FEED PUMP LOCAL CONTROLS 4
Exhibit G 5
Exhibit e Instructions for Prepara-tion of Data Entry Sheets for Licensee Event Report (LER) File (NUREG 0161)
Salem as Source
WO NO 870323040 870323041 870323042 870323044 870715033 PSE&G SALEM GENERATING STATION SAFETY RELATED WORK ORDER LOG SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
- 21 SWGR SUPPLY FAN FAILURE DESCRIPTION:
EXPANSION JOINTS ON INLET AND OUTLET SIDE OF 21 SWITCH GEAR TORN.
REPLACE 2
22 SWGR SUPPLY FAN FAILURE DESCRIPTION:
EXPANSION JOINTS ON INLET AND OUTLET SIDE OF 22 SWITCH GEAR TORN.
REPLACE.
2
- 23 SWGR SUPPLY FAN FAILURE DESCRIPTION:
EXPANSION JOINT ON INLET AND OUTLET SIDE OF 23 SWITCH GEAR TORN.
REPLACE.
2
- 22 FHB EXHAUST FAN FAILURE DESCRIPTION:
- 22 FUEL HANDLING EXHAUST FAN HAS A HOLE IN THE DISCHARGE FLEX JOINT.
PATCH.
2 2LA33 90 FAILURE DESCRIPTION:
2LA3390 CONTAINMENT SUMP LEVEL RECORDER CHART NOT ADVANCING.
WO NO 870901175 871026172 871026175 871105109 871106081 SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
2BRE16 FAILURE DESCRIPTION:
2BRE16 LEAK DOWN STREAM OF 2BR145 AT VESSEL.
2 23 SJ13 9 FAILURE DESCRIPTION:
23SJ19 FAILED LEAK RATE TEST.
GROUND OUT SEAL WELDED BONNET.
REPAIR MARK NO. FA-45.
2 24SJ139 FAILURE DESCRIPTION:
24SJ139 FAILED LEAK RATE TEST.
GROUND OUT SEAL WELDED BONNET.
REPAIR MARK NO. FA-45.
2 2C D/G SUMP PUMP FAILURE DESCRIPTION:
2C DIESEL ROOM SUMP PUMP STARTS BUT WILL NOT PUMP.
TROUBLESHOOT.
2 21 eves MONITOR PUMP FAILURE DESCRIPTION:
21 eves MONITOR TANK PUMP RUNS NOISILY AND TRIPS.
TROUBLESHOOT.
r WO NO 871202192 871203161 871208160 871228123 880102040 SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
2CV25 3 FAILURE DESCRIPTION:
2CV253, BORON BUILT UP, COVERS ENTIRE RELIEF VALVE.
2 HANGER MSG-268 FAILURE DESCRIPTION:
HANGER MSG-268, WELD REPAIR AND REINFORCE HANGER.
2 25 CFCU INBOARD FAN FAILURE DESCRIPTION:
25 CONTAINMENT FAN COIL UNIT INBOARD BEARING IS BAD.
2 22 RAD WASTE GAS COMPRESSOR PUMP REPLACE BEARING.
FAILURE DESCRIPTION:
22 RAD WASTE GAS COMPRESSOR PUMP: TRIPS.
INVESTIGATE AND REWORK.
2 22 SW PUMP FAILURE DESCRIPTION:
22 SERVICE WATER PUMP PACKING GLAND STUDS ARE SHEARED.
REPLACE STUDS.
WO NO 880104159 SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
2CC215 FAILURE DESCRfPTION:
2CC215 WILL NOT OPEN FROM CONTROL ROOM.
TROUBLESHOOT.
e MAJOR PLANT MODIFICATIONS REPORT MONTH -
JANAURY 1988
- DCR SAFETY EVALUATION 10 CFR 50.59 e
DOCKET NO: 50-272 UNIT NAME:
~S~a~l~e-m~~2~~~~
DATE:
February 10,1988 COMPLETED BY:J.Ronafalvy TELEPHONE: (609)339-4455 This information was not available at the time of this report, however, it will be included in future reports.
DCR - Design Change Request
\\
SALEM GENERATING STATION MONTHLY OPERATING
SUMMARY
UNIT NO. 2 JANAURY 1988 The Unit began the period operating at full power and continued to operate at that level unitl January 3, 1988, when a minor load reduction was performed to facilitate repairs to No. 23 Heater Drain Pump.
The repairs were completed and the Unit was restored to full power on January 4, 1988.
The Unit continued to operate at full power until January 31, 1988, when the Unit was removed from service at 1606 hours0.0186 days <br />0.446 hours <br />0.00266 weeks <br />6.11083e-4 months <br /> to repair a non-isolable turbine electro-hydraulic control system oil leak.
Following repairs, which were completed with the Reactor critical, the Unit was synchronized at 1950 hours0.0226 days <br />0.542 hours <br />0.00322 weeks <br />7.41975e-4 months <br /> the same day.
Power escalation was in progress when the period ended.
REFUEL ING INFORMATION DOCKET NO.:
UNIT NAME:
50-311 Salem 2 COMPLETED BY:
J. Ronafalvy DATE: February 10, 1988 609/935-6000 TELEPHONE:
EXTENSION 4455 Month JANAURY 1988
- 1.
Refueling information has changed from last month:
YES NO X
- 2.
Scheduled date for next refueling:
September 3, 1988
- 3.
Scheduled date for restart following refueling: November 2,1988
- 4.
A)
Will Technical Specification changes or other license amendments be required?
YES NO X
B)
Has the reload fuel design been reviewed by the Station Operating Review Committee?
YES NO X
If no, when is it scheduled?
August, 1988
- 5.
Scheduled date(s) for submitting proposed licensing action:
August 1988 if required
- 6.
Important licensing considerations associated with refueling:
- 7.
- 8.
- 9.
NONE Number of Fuel Assemblies:
A)
Inc ore B)
In Spent Fuel Storage Present licensed spent fuel storage capacity:
Future spent fuel storage capacity:
Date of last refueling that can be discharged to spent fuel pool assuming the present licensed capacity:
8-l-7.R4 19 3 224 11 70 1170 March 2003
. \\. -~* "
- ops~G Pu.blic Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
Dear Sir:
MONTHLY OPERATING REPORT SALEM NO. 2 DOCKET NO. 50-311 February 15, 1988 In compliance with Section 6.9.1.6, Reporting Requirements for the Salem Technical Specification, the original copy of the monthly operating reports for the month of January 1988 are being sent to you.
Average Daily Unit Power Level Operating Data Report Unit Shutdowns and Power Reductions Safety Related Maintenance Major Plant Modification Operating Summary Refueling Information Sincerely yours, tWl}1;J:/&
General Manager -
Salem Operations RH:sl cc:
Mr. William T. Russell Regional Administrator USNRC Region I 631 Park Avenue King of Prussia, PA 19406 Enclosures 8-l-7.R4 The Energy People 95-21 89 (11 M) 12-84