P._VERAGE DAILY UNIT POWER LEVEL Completed by Pell White Docket No.
Unit Name Date Telephone Extension Month December 1987 Day Average Daily Power Level (MWe-NET}
Day Average Daily (MWe-NET}
1 0
17 82 2
0 18 751 3
0 19 1053 4
0 20 1096 5
0 21 1097 6
0 22 1179 7
0 23 1037 8
0 24 1068 9
0 25 1104 10 0
26 1092 11 0
27 1102 12 0
28 1105 13 0
29 1100 14 0
30 1106 15 0
31 1112 16 0
Pg. 8.1-7 Rl 50-311 Salem # 2 January 11, 1988 609-935-6000 4451 Power Level
OPERATING DATA REPORT Completed by Pell White 2E_~rating Status Docket No.
Date Telephone Extension 50-311 January 11,1988 935-6000 4451
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
Unit Name Salem No. 2 Notes Reporting Period December 1987 Licensed Thermal Power (MWt) 3411 Nameplate Rating (Gross MWe) 1170 Design Electrical Rating (Net MWe) 1115 Maximum Dependable Capacity(Gross MWe)ll49 Maximum Dependable Capacity (Net MWe) 1106 If Changes Occur in Capacity Ratings (Items 3 through 7) since Last Report, Give Reason N/A
~~~~~~~-~~~~~~~~~--~~~~----:.~~-~~~~~
- 9.
Power Level to Which Restricted, if any (Net MWe)
N/A
~~~~~~~~~~~-
- 10. Reasons for Restrictions, if any N/A
'~~~~~~~~~~~~~~~~~~-
- 11. Hours in Reporting Period
- 12. No. of Hrs. Reactor was Critical
- 13. Reactor Reserve Shutdovm Hrs.
- 14. Hours Generator On-Line
- 15. Unit Reserve Shutdown Hours
- 16. Gross Thermal Energy Generated (MWH)
- 17. Gross Elec. Energy Generated (MWH)
- 18. Net Elec. Energy Generated (MWH)
- 19. Unit Service Factor
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (using MDC Net)
- 22. Unit Capacity Factor This Month 744 355. 2 0
346.6 0
1135051 377410 355705 46.6
-46.6--
43.2 Year to Date 8760
-6423 ___ 0_
0 6343.4 0
19642049 6452330 6171973 7 2. 4 72.4 63.7 Cumulative 54505 32362.9 0
31281.8 0
45650521 31629470 30019378 57.4 57.4 49.8 (using DER Net) 42.9 63.2 49.4
- 23. Unit Forced Outage Rate 0
9.1 31.0
- 24. Shutdowns scheduled over next 6 months (type, date and duration of each)
N/A
- 25. If shutdown at end of Report Period, Estimated Date of Startup:
N/A 8-l-7.R2
Completed by No.
Date 0197 10-24-87 1
F: Forced S: Scheduled UNIT SHUTDOWN AND POWER REDUCTIONS REPORT MONTH DECEI'IBER 1987 Docket No.
Unit Name Date Telephone Extension 50-311 Salem No.2 Pell White Method of Duration Shutting Type Hours Reason Down 1
2 Reactor s
1305.7 B
1 2 Reason A-Equipment Failure-explain B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & Licensing F-Administrative G-Operational Error-explain H-Other-explain License Event Report Exam System Component Code 4 Code 5 ED CKTBRK 3' Method 1-Manual 2-Manual Scram.
3-Automatic Scram.
4-Continuation of Previous Outage 5-Load Reduction 9-0ther January 11, lB 8 8 609-935-6000 4451 Cause and Correptive Action to Prevent Recurrence Circuit Breaker Verification 4
Exhibit G Instructions for Prepara-tion of Data Entry Sheets for Licensee Event Report (LER) File (NUREG 0161) 5 Exhibit Salem as Source
WO NO 870506024 870901154 870930084 871014082 871030085 PSE&G SALEM GENERATING STATION SA.FETY RELATED WORK ORDER LOG SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
22CRDM VENT FAN FAILURE DESCRIPTION:
22CRDM VENT FAN TRIPPED ON OVERLOAD.
MOTOR AND ELEC. CIRCUIT.
2 2CN45 FAILURE DESCRIPTION:
2CN45 DEMAND IND = 100%.
VALVE IS CLOSED WITH BEZEL.
2 2CH61 FAILURE DESCRIPTION:
VALVE FAILED SURVEILLANCE A-142.
REMOVE VALVE.
INSPECT AND REPAIR AS NECESSARY.
2 RVLIS FAILURE DESCRIPTION:
RVLIS A, B, TRAIN/INVESTIGATE AND REWORK, REPAIR AS REQUIRED.
2
- 2 TURBINE CRANE FAILURE DESCRIPTION:
- 2 TURBINE CRANE/AUX HOIST CABLE IS KINKED.
REPLACE CABLE.
WO NO 871111052 871119127 871127101 871128023 SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
2SW319 FAILURE DESCRIPTION:
2SW319 CRACK IN THE NIPPLE.
NEED SCAFFOLD BUILT.
2 P250 HEAD CRASH FAILURE DESCRIPTION:
INVESTIGATE AND REPAIR P250 HEAD CRASH.
2 2SW180 FAILURE DESCRIPTION:
2SW180 WELD TO INLET FAILED.
REPAIR WELD PER DR SSP-87-5190 2
2B DIESEL GENERATOR OUTPUT BREAKER FAILURE DESCRIPTION:
2B DIESEL GENERATOR OUTPUT BREAKER TRIPPED ON REVERSE PO~'JER.
TROUBLESHOOT AND REWORK.
WO NO 871130170 871203148 871205042 871207127 871207176 SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
2 COMPUTER INVERTER FAILURE DESCRIPTION:
2 COMPUTER INVERTER WILL NOT GO IN SERVICE.
2 2 FP261 FAILURE DESCRIPTION:
DURING VALVE CYCLING UNABLE TO CLOSE VALVE COMPLETELY 2
- 21 BIOSHIELD DOOR FAILURE DESCRIPTION:
- 21 BIOSHIELD DOOR LOCK IS MALFUNCTIONING, TROUBLESHOOT.
2 22 SPENT FUEL PIT PUMP BREAKER FAILURE DESCRIPTION:
BREAKER WILL NOT CLOSE.
TROUBLESHOOT AND REPAIR PROBLEM WITH BREAKER NOT CLOSING.
2 PZR. 22 GROUP BACK UP HEATERS FAILURE DESCRIPTION:
TROUBLESHOOT AND CORRECT PROBLEM OF PZR. 22 GROUP HEATERS.
WO NO 871209064 871213137 871214118 871214124 871216081 SALEM UNIT 2 UNIT EQUIPMENT IDENTIFICATION 2
21 BAT PUMP FAILURE DESCRIPTION:
21 BAT PUMP HAS A BAD MECHANICAL SEAL LEAK.
REPLACE 2
23SW58/23 CFCU FAILURE DESCRIPTION:
2 21 ACCUMULATOR LEVEL CHANNEL A FAILURE DESCRIPTION:
2 21 ACCUMULATOR LEVEL CHANNEL B FAILURE DESCRIPTION:
2 REACTOR TRIP BYPASS BREAKERS 23SW58/23 CFCU INLET ISOLATION VALVE, VALVE EXCEEDED STROKE.
21 ACCUMULATOR LEVEL CHANNEL "A" IS GREATER THAN 22 ACCUMULATOR.
21 ACCUMULATOR LEVEL CHANNEL "B" IS LESS THAN 22 ACCUMULATOR.
FAILURE DESCRIPTION:
REACTOR TRIP BYPASS BREAKERS "A" AND "B", UNABLE TO VERIFY OPEN.
TROUBLESHOOT CONTACT INDICATIONS.
S~.LEM UNIT 2 WO NO UNIT EQUIPMENT IDENTIFICATION 871218083 2
21 GB924 FAILURE DESCRIPTION:
21 GB924 HAS A BAD BODY TO BONNET STEM LEAK.
REFURMANITE
M.P.JOR PLANT MODIFICATIONS REPORT MONTH DECEMBER 1987
- DCR NO.
PRINCIPAL SYSTEM DOCKET NO.~
50-272 UNIT NAM.E:
-S-a~l-e-m-~1------
DATE:
~anuary 11,1988 COMPLETED BY: J. Ronafalvy TELEPHONE:
609/339-4455 SUBJECT Information not available for this report due to changes in system.
This information will be included in next report.
- DCR - Design Change Request
SALEM GENERATING STATION MONTHLY OPERATING
SUMMARY
UNIT NO.,2 DECEMBER 1987 The Unit remained shutdown as modifications in support of the breaker coordination and electrical configuration issues were completed.
Following completion of the modifications, a Safety Evaluation Report was submitted to the NRC.
On December 11, 1987, start-up authorization for Salem Unit 2 was received from the NRC.
Start-up was commenced and Reactor criticality was achieved at 0451 hours0.00522 days <br />0.125 hours <br />7.457011e-4 weeks <br />1.716055e-4 months <br />, on December 17, 1987.
The Unit reached full power on December 18, 1987, and continued to operate at that level for the remainder of the period.
r REFUELING INFORMATION DOCKET NO.: 50-311 UNIT NAME: Salem 2 COMPLETED BY~ J. Ronafalvy DATE: Janua.ry 11, 1988 TELEPHONE: 609/935-6000 EXTENSION --.4~4~5~5:--~--~~~~
Month DECEMBER 1987 lo Refueling information has changed from last month:
YES NO X
- 2.
Scheduled date for next refueling:
September 3, 1988
- 3.
Scheduled date for restart following refueling: November 2,1988
- 4.
A)
Will Technical Specification changes or other license amendments be required?
YES NO X
B)
Has the reload fuel design been reviewed by the Station Operating Review Committee?
YES NO X
If no, when is it scheduled?
August, 1988
- 5.
Scheduled date(s) for submitting proposed licensing action:
August 1988 if required
- 6.
Important licensing considerations associated with refueling:
- 7.
- 8.
- 9.
NONE Number of Fuel Assemblies:
A)
Inc ore B)
In Spent Fuel Storage Present licensed spent fuel storage capacity~
Future spent fuel storage capacity:
Date of last refueling that can be discharged to spent fuel pool assuming the present licensed capacity:
8-l-7.R4 19 3 224 1170 1170 March 2003
0 l>S~G Publk Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
Dear Sir:
MONTHLY OPERATING REPORT SALEM NO. 2 DOCKET NO. 50-311 January 11, 1988 In compliance with Section 6.9.1.6, Reporting Requirements for the Salem Technical Specification, the original copy of the monthly operating reports for the month of December 1987 are being sent to you.
Average Daily Unit Power Level Operating Data Report Unit Shutdowns and Power Reductions Safety Related Maintenance Major Plant Modification Operating Summary Refueling Information Sincerely yours, 0-~Y-J. Mo Zupko, Jr.
General Manager -
Salem Operations RH:sl cc:
Mr. William T. Russell Regional Administrator USNRC Region I 631 Park Avenue King of Prussia, PA 19406 Enclosures 8-1-7.R4 The Energy People 95-2189 (11 M) 12-84