Docket Nos. 50-272 50-311 Public Service Electric and Gas Company ATTN:
Mr. Richard A. Uderitz Vice President - Nuclear P. 0. Box 236 Hancock 1 s Bridge, New Jersey 08038 Gentlemen:
NOV 2 7 1984
Subject:
10 CFR 50.54(a) Quality Assurance Program Description Review, Salem Generating Station, Units No. 1 a~d 2 In accordance with the requirements of 10 CFR 50.54(a), your letter of September 26,
- 1984, forwarded to us Chapter 17, Quality Assurance (QA),
Revision 3, of the updated Final Safety Analysis Report (FSAR).
We have reviewed this QA program description and found that the changes made do not reduce previously made commitments and therefore are acceptable provided the following items of concern are resolved, as discussed during the telephone conservation of November 16, 1984, between Mr. T. Shaub of our staff and your Mr. W. Shultz, by February 20, 1985.
- 1.
Revise section 17.2.1.2.4.1 to clarify the qualifications required for the Manager, Nuclear Operations Quality Assurance
- 2.
Establish responsibility for preparing and maintaining the Quality Assurance Manual
- 3.
In section 17.2.10, replace the word 11may 11 with 11 shall 11 in the paragraph describing the inspection of operatin~ activities We note that your submittal of September 26, 1984 includes neither the reasons for the changes to the QA program description nor for concluding that the revised program continues to meet Appendix B to 10 CFR 50 as re qui red by 10 CFR 50.54(3)(ii).
We will expect future submittals to provide this information.
-~~~ 2~i%Ea 0 o~~i~}l~
p OFFICIAL RECORD COPY QA PD FOR SALEM -
11/20/84 0001.0.0 /o Gl oa I -11""'-"'-
,pl Public Service Electric and Gas Co.
2 The effectiveness of your QA Program implementation will continue to be subject of routine regional inspections.
If you have any questions concerning the above, please contact Mr. T. Shaub of our staff (215) 337-5244.
cc:*.
Sincerely, Original Sigu*d JlYI # ~
homas T. Martin, Director ivision of Engineering and Technical Programs R. L. Mittl, General Manager - Nuclear Assurance and Regulation J.M. Zupko, Jr., General Manager - Salem Operations E. A. Liden, Manager - Nuclear Licensing and Regulation C. P. Johnson, Manager - Quality Assurance Nuclear Operations P. M. Krishna, Manager - Nuclear Review Board M. J. Wetterhahn, Esquire R. Fryling, Jr., Esq~ire Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector State of New Jersey QA Branch, IE bee:*:
Region I Docket Room (with concurrences)
Senior Operations Officer (w/o encls)
DPRP Section Chief NRC Resident Inspector QA Branch, IE RI:DETP Shaub/mlb
/it.M.
11/;t~/84
~£DETP
/Spraul 11/52~ /84
~~J
~ETP neter 11/).~ /84 OFFICIAL RECORD COPY QA PD FOR SALEM - 0001.1.0 11/20/84