ML18092A329

From kanterella
Jump to navigation Jump to search
Application for Amend to Licenses DPR-70 & DPR-75,adding Tech Specs for Accident Monitoring Instrumentation & Radiation Monitoring Instrumentation,Per NUREG-0737 & Generic Ltr 83-37.Fee Paid
ML18092A329
Person / Time
Site: Salem  
Issue date: 09/21/1984
From: Liden E
Public Service Enterprise Group
To: Varga S
Office of Nuclear Reactor Regulation
Shared Package
ML18092A330 List:
References
RTR-NUREG-0737, RTR-NUREG-737 GL-83-37, LCR-83-14, NUDOCS 8410190339
Download: ML18092A329 (55)


Text

Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Nuclear Department Ref:

LCR-83-14 September 21, 1984 Director of Nuclear Reactor Regulation

u. s. Nuclear Regulatory Commission Washington, D. C.

20555 Attention:

Mr. Steven A. Varga, Chief Operations Reactors Branch 1 Division of Licensing Gentlemen:

REQUEST FOR AMENDMENT FACILITY OPERATING LICENSES UNIT NOS. 1 AND 2 SALEM GENERATING STATION DOCKET NOS. 50-272 AND 50-311 In accordance with the Atomic Energy Act of 1954, as amended and the regulations thereunder, we hereby transmit copies of our request for amendm~nt and our analyses of the changes to Facility Operating Licenses DPR-70 and DPR-75 for Salem Generating Station, Unit Nos. 1 and 2.

This amendment request consists of a revision to Technical Specifications, Appendix A, sections regarding Accident Monitoring Instrumentation and Radiation Monitoring Instrumentation.

In accordance with the fee requirements of 10CRF170.21, a check in the amount of $150.00 is enclosed.

Pursuant to the requirements of 10CFR50.91, a copy of this request for amendment has been sent to the State of New Jersey as indicated below.

8410190339 840921 PDR ADOCK 05000272 P

PDR The Energy People 95-2168 (25M) 6-84

Mr. Steven 9/21/84 This submittal includes three (3) signed originals and forty (40) copies.

Enclosure C

Mr. Donald C. Fischer Licensing Project Manager Mr. James Linville Senior Resident Inspector Sincerely, E. A. Liden Manager -

Nuclear Licensing and Regulation Mr. Frank Cosolito, Acting Chief Bureau of Radiation Protection Department of Environmental Protection 380 Scotch Road Trenton, New Jersey 08628 Honorable Charles M. Oberly, III Attorney General of the State of Delaware Department of Justice 820 North French Street Wilmington, Delaware 19801

\\

I Ref: LCR-83-14 STATE OF NEW JERSEY )

)

ss:

COUNTY OF SALEM COUNTY OF SALEM

)

RICHARD A. UDERITZ, being duly sworn according to law deposes and says:

I am a Vice President of Public Service Electric and Gas Company, and as such, I find the matters set forth in our Request for Amendment dated September 21, 1984, are true to the best of my knowledge, information and belief.

Subscribed and sworn to before me this a~

lj(...- day of ~4 e,.v1, 1984 Notary Public of New Jersey DDNMA G. Hl7CHNER NOTAHY PUBLIC OF NEW JERSEY My Commission expires on MyCnmmlssjonExpjresMarch24,1987 I

' I PROPOSED CHANGE TECHNICAL SPECIFICATIONS SALEM UNITS l AND 2 DESCRIPTION OF CHANGE To respond to NUREG-0737 requirements, make the following changes:

Add Noble Gas Effluent Monitors and Containment high range Area Monitors to Specification 3.3.3.6, Radiation Monitoring Instrumentation tables.

Remove from £Jnit No. 1 only, item 2.a.3 Pixed Filter Iodine Monitor from Tables 3.3-6 and 4.3-6.

The format and ACTION STATEMENTS of Technical Specification 3.3.3.7, Accident Monitoring Instrumentation, for Salem Unit No.

2 sho"uld be modified to agree with the format and ACTION STATE-MENTS used on Unit No. 1.

Limiting Conditions fpr Operation and surveillance Requirements for accident monitoring instrumentation should be included in Tables 3.3-lla, 3.3~llb, and 4.3-11 for both units.

REASON FOR CHANGE These proposed changes will add specifications for accident and radiation monitoring to provide assurance that the monitoring equipment installed at the facility is operated and maintained within acceptable limits.

This proposed change is the result of q review of NUREG-0737 Technical Specifications guidance provided in NRC Generi~ Letter 83-37 and an additional request (Varga to Uderitz, dated November 17, 1983) for Technical Specifications for ICCI equipment.

The Noble Gas Effluent Monitors and Containment high range Area Monitors are added to ensure that the monitors, installed in compliance with NUREG 0737 requirements, are operable in the appropriate MODES and receive proper surveillance attention.

The specifications for containment atmosphere radiation instrumentation in Tables 3.3-3 and 3.3-4 have been replaced by cross-references to the applicable specifications of Tables 3.3-6 and 4.3-6 with the purpose of eliminating duplication and assuring consistency in the requirements applicable to the containment noble gas monitor (RI2A) and the containment air particulate activity monitor (RllA).

Specifications for the containment iodine sampler (Rl2B) h~ve been deleted, acknowledging that the sampling medium is a cumulative sampler (charcoal cartridge) unsuitable of providing direct correlation to atmosphere concentration and therefore inappropriate for safety system actuation.

  • e LCR.83-14 (continued)

The original intent of the purge and exhaust isolation function of the containment atmosphere radioactive instrumentation as specified in Tables 3.3-3 and 3.3-4 was to provide isolation of any containment purges during plant operation (modes 1,2,3 and

4) in the event of increased airborne radioactivity representative of an abnormal condition.

However, per Specification 3.6.1.7 (as revised by Amendment #41), the containment purge supply and exhaust isolation valves shall be closed during modes 1,2,3 and 4 (valves immobilized in shut position with control air to valve operators isolated and tagged out of service).

The proposed revisions to the containment radiation monitoring instrumentation address its dual function:

1) providing the safety function of containment isolation at early indication of abnormal conditions during refueling; and 2) serving as an effluent monitor during periods of allowable containment purge and pressure/vacu1m relief with alarm/trip setpoints to ensure maximum release rates are not exceeded.

As proposed by this amendment request the intended safety function of the containment radiation monitoring instruments (specifically, Rl2A and RllA) are appropriately addressed in Tables 3.3-6 and 4.3-3.

Per Table 3.3-6 (as proposed),

~12A and RllA wili provide containment isolation at 2 x background during mode 6 in the event of increased containment airborne activity, indicative of an abnormal condition (e.g., fuel handling accident).

Also, as proposed by this amendment request, and addressed in Tables 3.3-13 and 4.3-13 (and cross-referenced in Table 3.3-6),

the.containment noble gas monitor (Rl2A) may function as an effluent monitor for containment purges during mode 5 and for pressure/vacuum reliefs during modes 1,2,3,4 and 5.

The alarm/trip setpoint of Rl2A when functioning as an effluent monitor is established per Specification 3.3.3.9 so as to ensure the dose rate at the site boundary does not exceed 500 mrem/year during the release (i.e., implementation of the Maximum Permissible Concentrations (MPC) as specified in 10 CFR 20, Appendix B, Table II, Column 1).

The removal of t~e*Fixed Filter Iodine (FFI) monitor from Tables 3.3-6 and 4.3-6 on Unit No. 1 is consistent with Unit No. 2 Technical Specifications and with Westinghouse PWR Standard Technical Specifications.

Technical Specifications issued with Unit No. 2 Facility Operating License and those provided as guidance in Generic Letter 83-27 do not take into consideration acceptable alternate plant Accident Monitoring Instrumentation capabilities as was done on Unit No. 1 Technical Specifications.

The existing

I JI

  • LCR 83-14 (continued) format used on Unit 1 Accident Monitoring was used for this change.

This format provides ACTION STATEMENTS for certain

.monitoring capabilities for which alternate methods of monitoring have been evaluated and approved by NRC in NUREG-0517, Safety Evaluation Report, Supplements 4 and 5 for Salem Unit 2 and in Amendment 39 to the Unit No. 1 license.

SIGNIFICANT HAZARDS EVALUATION A review of the TMI items for which Technical Specifications changes are required by the NRC shows that:

1.

The proposed changes to Technical Specifications are associated with specific design changes to the facility.

For each design change (DCR) adding equipment required to satisfy a NUREG-0737 item, an Engineering Safety Evaluation was completed in accordance with 10CFR 50.59.

Each of these Safety Evaluations indicated that no Unreviewed Safety Question was involved with the change.

2.

The Unit No. 2 Accident Monitoring Instrumentation Technical Specification modifications were worded to agree wrth Unit No. 1 Technical Specifications which have been previously reviewed and found acceptable by the_ NRC.

The additional requirements for ICCI equipment on both Salem units are worded to agree with the intent of the guidance provided in NRC Generic_ Letter 83-27, dated November 1, 1983.

3.

Where the proposed Technical Specification change varies from the guidance provided by NRC Generic Letter 83-27,

- regarding Containment Wide Range Water Level, a new ACTION (7) is introduced to provide for continued operations with one of the two W.R. instruments INOPERABLE until the next CHANNEL CALIBRATION, which must be done during MODE 5, COLD SHUTDOWN.

This.

variance is necessary due to the physical design relationship of the containment sump and the level detectors.

The removal of the containment sump screen to repair a containment water level instrument would render the containment sump and, consequently, the entire ECCS (recirculation mode)

INOPER~BLE, requiring plant shutdown within one hour.

This action, resulting from only one wide range containment water level instrument out of service, would result in a plant shutdown within one hour while redundant contain~ent water level indication is still available for post accident information.

_I

l

  • LCR 83-14 (continued)

Given the similarity of the two units and the fact that all design changes associated with the proposed Technical Specification modifications involve no Unreviewed Safety Question or were previously reviewed by the NRC and found acceptable, with the exception of item 3 above, the proposed Technical Specifications changes are deemed to involve no significant hazards consideration.

The new specifications requested constitute addition of limitations and surveillance requirements to existing specifications and thereby conform to example (ii) provided by NRC in 48FR14870 as guidance concerning the application of standards for a No Significant Hazards determination.

I -,-

---~ -

1 l t*

e*

c: z H

8 w

I I--'

co TABLE 3.3-3 (Continued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION MINIMUM TOTAL NO.

CHANNELS CHANNELS FUNCTIONAL UNIT OF CHANNELS TO TR IP OPERABLE

b.

Phase 11B 11 Isolation

1) Manual 2 sets of 2 1 set of 2 2 sets of 2
2) Automatic 2

1 2

Actuation Logic

3)

Containment 4

2 3

Pressure--High-High

c.

Purge and Exhaust Isolation l}

Manual 2

1 2

2)

Containment Atma-per table 3.3-6 sphere Radioactivity-High

4.

STEAM LINE ISOLATION

a.

Manual l/steam line l/steam line l/operat i ng steam line

b.

Autornat i c Actuation 2

1 2

Logic

c. Containment Pressure--

4 2

3 High-High

-~- 8410190341 840921


)

PDR ADOCK 05000272 p

PDR APPLICABLE MODES ACTION 1, 2' 3 ' 4 18 1, 2, 3' 4 13 -

1, 2, 3 16 1, 2, 3, 4 17 e

1, 2' 3 18 1, 2, 3 13 1 ' 2, 3 16

c:: z H

t-3 w

I N

U1 TABLE 3.3-4 *(Continued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION TRIP SETPOINTS FUNCTIONAL UNIT

2.

Containment Atmosphere Gaseous Radioactivity

4.

STEAM LINE ISOLATI-ON

a.

Manual

b.

Automatic Actuation Logic

c. Containment Pressure--High-High
d. Steam Flow in Two Steam Lines --

High Coincident. with Tavg -- low-low or Steam Line Pressure--low TRIP SETPOINT ALLOWABLE VALUES per Table 3. 3-6 Not Applicable Not Appl*i cable 5:_ 23.5 psig

< A function defined as follows:

A AP corresponding to 40% of full steam flow betweem 0% and 20% load and then a*AP increasing linearly to a AP correspond-ing to 110% of full steam flow at full load T avg ~ 543°F

~ 500 psig steam line pressure Not Applicable Not Applicable 5:_ 24 psig

<A function defined as.

follows:

A AP corresponding to 44% of full steam flow between 0% and 20% load and then a AP increasing linearly to a AP corresponding to 111.5% of full steam flow at full load Tavg ~ 541°F

~ 480 psig steam line pressure I

c::: z H

t-3 w

w I

w

°'

TABLE 3.3-6

~ADIATION MONITORING INSTRUMENTATION MINIMUM INSTRUMENT CHANNELS APPLICABLE ALARM/TRIP OPERA.BLE MODES SET POINT

1.

AREA MONITORS

a. Fuel Storage Area - R5/R9 1

< 15 mR/hr

b. Containment Area - R44 2

1, 2, 3 & 4

< 103 R/hr

2.

PROCESS MONITORS

a. Containment
1)

Gaseous Activity a)

Purge & Pressure -

1#

6 2_ 2 x background Vacuum Relief and Isolation - R12a 1, 2, 3, 4 & 5 per Specification b)

RCS Leakage 3.3.3.9 Detection - R12a 1, 2. 3 & 4 N/A

2) Air Particulate Activity a)

Purge & Pressure -

1 6

< 2 x background Vacuum Relief Isolation - Rlla b)

RCS Leakage 1, 2, 3 & 4 N/A Detection - Rlla

b.

Noble Gas Effluent Monitors

1)

Medium Range Auxiliary 1

1,* 2, 3 & 4

< *3.0 x 10-2 uCi/cm3 Building Exhaust System (A la rm only)

(Pl ant Vent) - R45B

2)

High Range Auxiliary 1.

1, 2, 3 & 4

< 1.0 x 102 uCi/cm3 Building Exhaust System (Alarm only)

(~ant Vent) - R45C

  • With fuel in the storage pool or building.
  1. The unit vent sampling monitor (R-4lc) may also function in this capacity when the purge/pressure-vacuum relief isolation valves are open.

MEASUREMENT RANGE ACTION 10-l 104 nR/hr 19 1

107 R/hr 23 e

101 - 106 cpm 22 & 23 101 - 106 cpm 20 101 - 106 cpm 22 101 106 cpm

. 20 e

10 101 uCi/cm3 23 10 rnn uCi /cm3 23

c z H

t-3 w

I w CJ'\\

Ill TABLE 3.3-6 (CONTINUED)

RADIATION MONITORING INSTRUMENTATION INSTRUMENT

2.

PROCESS MONITORS

b.

Noble Gas Effluent Monitors

3) Main Steamlina Discharge (Safety Valves and Atmospheric Steam Dumps) - R46
4)

Condenser Exhaust System - R 15 MINIMUM CHANNELS APPLICABLE OPERABLE MODES 1/

1, 2, 3 & 4 MS Line 1

1, 2, 3 & 4 ALARM/TIU P SETPOINT

< 10 mR/hr Talarm only)

< 1.27 x 104 cpm Ta l a rm only )

MEASUREMENT RANGE 1 - 104 ITT</hr 1 - 106 cpm ACTION 23

' \\

e TABLE 3.3-6 (Continued)

TABLE NOTATION ACTION 19 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, perform area surveys of the monitored area with portable monitoring instrumentation at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

ACTION 20 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, comply with the ACTION req~irements of Specification 3.4.6.1.

ACTION 22 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, comply with the ACTION requirements of Specification 3.9.9.

ACTION 23 -

With the number of OPERABLE Channels less than required by the Minimum Channels OPERABLE requirements, initiate the preplanned alternate method of monitoring the appropriate parameter(s), within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, and:

SALEM -

UN IT 1

1) either restore the inoperable Channel (s) to OPERABLE status within 7 days of the event, or
2) prepare and submit a Special Report to the Commission pursuant to Specification 6.9.2 within 14 days following the event outlining the action taken, the cause of the inoperability and the plans and schedule for restoring the system to OPERABLE status.

3/4 3-37 i

I

q z H

1-3 w

I w CXl ni

, 2.

TABLE 4.3-3 (CONTINUED)

RADIATION MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL INSTRUMENT CHANNELS SOURCE CHANNEL FUNCTIONAL CHECKS CHECKS CALI BRA TI ON TEST PROCESS MONITORS

b.

Noble Gas Effluent Monitors

3)

Main Steamline Discharge s

M R

Q (Safety valves

~

atmospheric dumps) - R46

4)

Condenser Exh. Sys. - Rl5 s

M R

Q MODES IN WHICH SURVEILLANCE REQUIRED 1, 2, 3 &.

1, 2, 3 & 4

e.

INSTRUMENTATION ACCIDENT MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.3.7 The accident monitoring instrumentation channels shown in Table 3.3-lla and Table 3.3-llb shall be operable.

APPLICABILITY:

MODES 1, 2, and 3.

ACTION:

a.

As shown in Table 3.3-lla and.Table 3.3-llb.

b.

The provisions of Specification 3.Q.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.3.3.7 Each accident monitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK AND CHANNEL CALIBRATION operations at the frequencies shown in Table 4.3-11.

SALEM - UNIT 1 3/4 3-53

~

TABLE 3.3-lla ACCIDENT MONITORING INSTRUMENTATION

~

8 TOTAL NO.

REQUIRED I-'

OF NO. OF INSTRUMENT CHANNELS CHANNELS ACTION

1.

Reactor Coolant Outlet Temperature -

4 ( 1 /loop) 2 1

T HOT (Wide Range}

2.

Reactor Coolant Inlet Temperature -

4 (1/loop) 2 T COLD (Wide Range}

3.

Reactor Coolant Pressure {Wide Range) 2 2

l.
4.

Pressurizer Water Level 3 {hot) 2 1

w 5

  • Steam Line Pressure 3/Steam Generator 2/Steam Generator 1
1.

.i::.

w Steam Generator \\4ater Level {Narrow 3/Steam Generator 2/Steam Generator 1*

I

6.

U1 Range)

.i::.

7.' Steam Generator Water Level {Wide 4/(1/Steam Generator) 4 (l/Steam Gener~tor) 1 Range)

8.

Refueling Water Storage Tank Water 2

2*

1 Level e

9. Boric Acid T~nk Solution Level.

2 (1/tank}

2 ( 1 /tank) 3

10. Auxiliary Feedwater Flow Rate 4 (l/Steam Generator) 4 (l/Steam Generator) 4
11.

Reactor Cool ant System Subcool i ng 2*

2*

5 Margin *Monitor

12.

PORV PositiQn Indicator 2/valve**

2/valve**

1

c::: z H

8 TABLE 3.3-lla (CONTINUED)

ACCIDENT MONITORING INSTRUMENTATION TOTAL NO.

OF I-'

INSTRUMENT

  • CHANNELS REQUIRED NO. OF CHANNELS ACTION 1

w I

U1

~

Ill

13.

PORV Block Valve Positi6n Indicator

14.

Pressurizer Safety Valve Pas it ion Indicator

15.

Containment Pressure - Narrow Range

16.

Containment Pressure - Wide Range 17 *. Containment Water Level -

Wide Range

18.

Core Exit Thermocouples 2/valve**

2/valve**

4 2

2 65 2/valve**

2/valve**

2 2

2 4/core quadrant 1

7 7

1

(*)Total number of channels is considered to be two (2) with one (1) of the chan.nels being manual e

calculation by licensed control room personnel using data from OPERABLE wide range Reactor Coolant Pressure and Temperature along with Steam Tables as described in ACTION 5.

(**)Total number of channels is considered to be two (2) with one (1) of the.channels being any one (1) of.the following alternate means of determining PORV, PORV Block, or Safety Valve position:

Tailpipe Temperatures for the valves, Pressurizer Relief Tank Temperature Pressurizer*Relief Tank Level Operable.

w

~

w I

lJ1 U1 TABLE 3.3-llb

  • .ACCIDENT MONITORING INSTRUMENTATION INSTRUMENT
l. Reactor Cool ant Outlet Temperature -

T HOT (Wide Range)

2.

Reactor Coolant Inlet Temperature -

T COLO (Wide Range)

3.

Reactor Coolant Pressure (Wide Range)

4.

Pressurizer Water Level

5.

Steam Line Pressure

6.

Steam Generator Water Le_vel (Narrow Range)

7.

Steam Generator Water Level (Wide Range)

8.

Refueling Water Storage Tank Water Level

9.

Boric Acid Tank Solution Level

10.

Auxiliary Feedwater Flow Rate

11. Reactor Coolant System Subcooling Margin Monitor
12.

PORV Position Indicator TOTAL NO.

OF CHANNELS 4 (1/loop) 4 (1/loop) 2 3 (hot) 3/Steam Generator 3/Steam Generator 4/(1/Steam Generator) 2*

2 (1/tank) 4 (1/Steam Generator) 2*

2/valve**

MINIMUM NO. OF CHANNELS ACTION 1

2 1

e 1

2 1

2 1/Steam Generator 2

l/Steam Generator 2

3. (1/Steam Generator) 2 1

1 ( 1/tank}

'3 3 (l/Steam Generator) 6 1

6 1

2

c: z H

1-3 I-'

w I

Ul Ul ni

13.
14.
15.
16.
17.
18.

TABLE 3.3-llb (CONTINUED)

ACCIDENT MONITORING INSTRUMENTATION TOTAL NO.

OF INSTRUMENT CHANNELS PORV Block Valve Position Indicator 2/valve**

Pressurizer Safety Valve. Position 2/valve**

Indicator Containment Pressure - Narrow Range 4

Containment Pressure - Wide Range 2

Containment Water Level -

2 Wide Range Core Exit Thermocouples 65 MINIMUM NO. OF CHANNELS 1

1 1

1 1

2/core quadrant

(*)Total number of channels is considered to be two (2) with one. (1) of the channels being manual calculation by licensed control room personnel using data from OPERABLE wide range Reactor Coolant Pressure and Temperature along with Stea~ Tables as described in ACTION 5.

ACTION 2

  • 2 2

2 2

(**)Total number of channels is considered to be two (2) with one (1) of the channels being any e _

one (1) of the following alternate means of determining PORV, PORV Block, or Safety Valve position:*

Tailpipe Temperatures for the valves, Pressurizer Relief Tank Temperature Pressurizer Relief Tank Level Operable.

)

. t TABLE 3.3-lla & b (continued)

TABLE NOTATION ACTION 1 With the number of OPERABLE accident monitoring channels less than the Required Number of Channels shown in Table 3.3-lla, restore the inoperable channel(s) to OPERABLE status within 7 days, or be in HOT SHUTDOWN with~n the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 2 With the number of OPERABLE accident monitoring channels less than the MINIMUM Number of Channels shown in Table 3.3-llb, restore the inoperable channel(s) to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 3 With the number of OPERABLE channels one less than the Required Number o~ Channels shown in Table

3. 3-lla, operation. may proceed provided that the Boric Acid Tank associated with the remaining OPERABLE-channel satisfies all requirements of Specification 3.1.2.8.a.

ACTION 4

~ith the number of OPERABLE channels one l*ess than the Required Number of Channels shown in Table 3.3.lla, operations may proceed provided that an OPERABLE Steam Generator Wide Range Level channel is available as an alternate means of indication for the Steam Generator with no OPERATABLE Auxiliary Feedwater Flow Rate channel.

ACTION 5 With the number of OPERABLE channels less than the Required Number of Channels show in Table 3.3-lla,

  • operation may proceed provided that Steam Tables are available in the Control Room and the following Required Channels shown in Table 3.3-lla are OPERABLE to provide an alternate means of calculating Reactor Coolant System subcooling margin:
a.

Reactor Coolant Outlet Temperature - THOT

(\\*il de Range)

b.

Reactor Coolant Pressure (Wide Range)

SALEM - UNIT 1 3/4 3-56

TABLE 3.3-lla & b (continued)

TABLE NOTATION ACTION 6 With the number of OPERABLE channels less than the Minimum Number of channels shown in Table 3.3-llb, restore the inoperable channel (s) to OPERABLE status within 7 days, or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 7 With the number of OPERABLE channels one less than the Required Number of Channels shown in Table 3.3-lla, operation may proceed until the next CHANNEL CALIBRATION (which shall be perform~d upon the next entry into MODE 5, COLD SHUTDOWN).

SALEM -

UN IT 1 3/4 3/56a

1.

w w

I U1

..._J TABLE 4.3-11 SURVEILLANCE REQUIREMENTS FOR ACCIDENT MONITORING INSTRUMENTATION INSTRUMENT

1. Reactor Coolant Outlet Temperature -

T HOT (Wide Range)

2.

Reactor Coolant Inlet Temperature -

T COLD (Wide Range)

J. Reactor Coolant Pressure (Wide Range)

4.

Pressurizer Water Level

5.

Steam Line Pressure

6.

Steam Generator Water Level (Narrow Range)

7.

Steam.Generator Water Level (Wide Range)

8.

Refueling Water Storage Tank Water Level

9.

Boric Acid Tank Solution Level

10.

Auxiliary Feedwater Flow Rate

11.

Reactor Coolant System Subcooling Margin Monitor CHANNEL CHECKS M

M M

M M

M M

M M

SU#

M CHANNEL CALIBRATION R

R R

R R

R R

R R

R N/A*

  1. Auxiliary Feedwater System *is used on each startup and flow rate indication is verified at that time.
  • The instruments used to develop RCS subcooling margin are calibrated on an 18 month cycle; the monitor will be compared quarterly with calculated subcooling margin for known input values.

CHANNEL FUNCT IONA1 TEST NA NA NA NA NA NA NA NA

~

TABLE 4.3-11 {CONTINUED)

SURVEILLANCE REQUIREMENTS FOR ACCIDENT MONITORING INSTRUMENTATION

~

H 1-3 CHANNEL I-'

CHANNEL CHANNEL FUNCTIONA11 INSTRUMENT CHECK CALI BRAT ION TEST

12.

PORV Position Indicator*

M NA Q

13.

PORV Block Valve Position Indicator M

NA

14.

Pressurizer Safety Valve Position M

NA R

Indicator

15. Conta:inment Pressure - Narrow Range M

NA NA

16. Containment Pressure - Wide Range M

R NA w

ii::.

17. Containment Water Level -

M R'

NA w

Wide Range

  • I Ul

-.J SU

18. Core Exit Thermocouples M

R NA

. INSTRUMENTATION RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.3.9 The radioactive gaseous effluent monitoring instrumentation channels shown in Table 3.3-13 shall be OPERABLE with their alarm/trip setpoints set to ensure that the limits of Specification 3.11.2.l are not exceeded.

The alarm/trip setpoints of these channels shall be determined in accordance with the (ODCM).

APPLICABILITY:

As shown in Table 3.3-13 ACTION:

a.

Wit~ a radioactive gaseous effluent monitoring

-instrumentation channel alarm/trip setpoint less conservative than required by the above specification,.

without delay suspend the release of radioactive gaseous effluents monitcreEi by the affected* channel or declare the channel inoperable or change the setpoint so it is acceptably conservative *

. b.

With less than the miniirum number of radioactive gaseous effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 3.3-13. Exert best efforts to return the instrument to operable status within 30 days and, if unsuccessful, explain in the next semi-annual radioactive effluent release report why the inoperability was not corrected in a timely manner.

c. The provisions of Specifications 3.~.3, 3.0.4, and 6.9.1.9.b are not applicable.

SURVEILLANCE REQUIREMENTS.

4.3.3.9 Each radioactive gaseous effluent monitoring instrumentation channel shall.be demonstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CALIBRATION, ANO CHANNEL FUNCTIONAL TEST operations at the f,requencies shown in Table 4.3-13.

SALEM - UN IT 1 3/4 3-64

c:::: z H

1-3 w

I CJ)

Ul TABLE 3.3-13.

RADIOACTIVE GASEOUS EFFLUENT MONITOR I NG INSTRUMENTATION INSTRUMENT

1.

WASTE GAS HOLDUP SYSTEM

a.

Noble Gas Activity Monitor - Providing

. Alarm and Automatic Termination of Rele~se (l-R41C)

b.

Oxygen Monitor

2.

CONTAINMENT PURGE AND PRESSURE - VACUUM RELIEF

3.
a.

Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release (l-R41C or l-Rl2A)

PLANT VENT HEADER SYSTEM#

a.

Noble Gas Activity Monitor (l-.Rl6 or l-R41C)

b.

Iodine Sampler

c. Particulate Sampler
d.

Flow Rate Monitor

  • e.

Sampler Flow Rate Monitor MINIMUM CHANNELS OPERABLE 1

1 1

1 1

1 1

1 APPLICABILITY

  1. The following process streams are routed to the plant vent where they are effectively monitored by the instruments described:

(a) Condenser Air Removal System (b)

Auxiliary Building Ventilation System (c) Fuel Handling Building Ventilation System (d)

Radwaste Area Ventilation System (e) Containment Purges Action item #34 applies to' the purging of the containment only.

ACTION 35 34 33

'\\

36

-36 32 32

TABLE 3.3-13 (Continued)

TABLE NOTATION ACTION 31 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, the contents of the tank(s) may be released to the environment provided that prior to initiating the release:

a. At least two independent samples of the tank's contents are analyzed, and
b.

At least.two technically qualified members of the Facility. Staff independently verify the release rate calculations and discharge valving lineup; Otherwise, suspend release of radioactive effluents.via-this pathway.

ACTION 32 -

With the number of channels OPERABLE less than

  • required by the Minimum Channels OPERABL~
  • requirement, effluent releases via this *pathway may continue provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

ACTION 33 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided grab samples are taken at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and these samples are analyzed for gross activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> *

. ACTION 34 -

With the number of channels OPERABLE less than required by the Mini mum Channels OPERABLE requirement, immediately suspend PURGING of radioactive effluents via this pathway.

  • At all ti mes, other than when the line is va 1 ved out and locked.
    • During waste gas holdup system operation.
      • During containment purges or*containment pressure vacuum re 1 i ef s.

SALEM - UNIT 1 3/4 3-66

TABLE 3.3~13 (Continued)

TABLE NOTATION ACTION 35 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, operation of the waste gas holdup

  • systeM may continue provided grab samples are collected at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and analyzed within the following 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

ACTION 36 -

With the number of channels OPERABLE less than required by the Mini!Tllm Channels OPERABLE requirement, effluent releases via this pathway may continue provided samples are continuously collected with _auxiliary sampling equipment as required in Table 4.11-2.

SALEM - UNIT 1 3/4 3-67

d z H

1-3 TABLE 4.3-13 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS INSTRUMENT CHANNELS OPERABLE SOURCE CHECK CHANNEL CALI BRA TI ON CHANNEL FUNCTIONAL TEST I-'

1.

WASTE GAS HOLDUP SYSTEM w

I O"I 00

2.
3.
a.

Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release (1-R41C)

b.

Oxygen Monitor CONTAINMENT PURGE ANO PRESSURE - VACUUM RELIEF

a.

Noble Gas Activity Monitor - Providing AlarJTI and Autom.atic;: Termination of Release (1-R41C or 1-Rl2A)

a.

Noble Gas Activity Monitor (1-Rl6 or 1-R41C)

b.

Iodine Sampler

c.

Par~iculate Sampler

d.

Flow Rate Monitor

e. Sampler Flow Rate.Monitor p

p R(3)

Q(l)

D N.A.

Q.( 4)

M p

p R(3)

Q(l)

D M

R(3)

Q(2) w N.A.

N.A.

N.A.

w N.A.

N.A.

N.A.

D N.A.

R N.A.

w N.A.

R N.A.

  1. The following process streams are routed to the plant vent where they are effectively monitored by the instruments described:

(a) Condenser Air Removal System (b) Auxiliary Building Ventilation System (c) Fuel Handling Building Ventilation System (d)

Radwaste Area Ventilation System (e) Containment Purges MODES IN WHICI SURVEILLANCE REQUIRED

  • e e

,).

TABLE 4.3-13 (Continued)

TABLE NOTATION (1)

The CHANNEL FUNCTIONAL TEST shall* also demonstrate that automatic isolation of this pathway and control room alarm annunciation occurs if any of the following conditions exist:

1.

Instrument indicates measured levels above the alarm/trip setpoint.

2.

Circuit failure.

(Loss of Power)

3.

Instrument indicates a downscale failure.

(Alarm Only)

(2)

The CHANNEL FUNCTIONAL TEST shall also demonstrate that control room alarm annunciation occurs if any of the following conditi.ons ex.ist:

1.

Instrument indicates measured levels above the alarm/trip setpoint.

2.

Circuit failure.

(Loss of Power)

3.

Instrument indicates a downscale failure.

4.

Instrument controls not set in operate mode.

(3)

The initial CHANNEL CALIBRATION was performed using appropriate liquid or gaseous calibration sources obtained from reputable suppliers.

The activity of the calibration sources were reconfirmed using a multi-channel analyzer which was calibrated using one or more NBS standards.

(4)

The CHANNEL CALIBRATION shall include the use of standard gas samples containing a nominal:

1.

One volume percent oxygen, balance nitrogen, and

2.

Four volume percent oxygen, balance nitrogen.

  • At a 11 ti mes
    • During waste gas holdup system opera~ion.
      • During containment purge or containment pressure -

vacuum relief.

SALEM - UNIT 1 3/4 3-69

(/)

TABLE 3.3-3 (Continued)

~

t-1 ti:l ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION

s:

MINIMUM c::

TOTAL NO.

CHANNELS CHANNELS APPLICABLE z

FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION H

~3 N

b. Phase 11B 11 Isolation
1)

Manual 2 sets of 2 1 set of 2 2 sets of 2 1, 2. 3, 4

.18

2)

Automatic 2

1 2

1, 2, 3, 4 13 -

Actuation Logic

3)

Containment 4

2 3

1, 2, 3 16 Pressure--High-High

c. Containment Ventilation w

Isolation w

1)

Manual 2

1 2

1, 2, 3, 4 17 I

f-'

00

2)

Automatic Actuation 2

1 2

1, 2, 3, 4 13 Logic

3)

Containment Atmo-per table 3.3-6 sphere Gaseous Radioactivity-High e

4.

STEAM LINE ISOLATION

a.

Manual 2/steam line l/steam line l/operating 1, 2. 3 21 steam line

b.

Automatic Actuation 2

1 2

1, 2, 3 20 logic

c.

Containment Pressure--

4 2

3 1, 2, 3 i6 High-High

c: z H

1-3 w

I N

°'

TABLE 3.3-4 (Continued).

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION TRIP SETPOINTS FUNCTIONAL UNIT

2.

Containment Atmosphere Gaseous Radioactivity

4.

STEAM LINE ISOLATION

a.

Manual

b. Automatic Actuation Logic
c.

Co~tainment Pressure--High-High

d. *Steam Flow iri Two Steam Lines ~

High Coincident with Tavg -- low-la.-1 or Steam Line Pressure--low TRIP SET POINT ALLOWABLE VALUES per Table 3.3-6 Not Applicable Not Applicable

~ 23.5..,sig

< A function defined as follows: A JYl corresponding to 40% of full steam flow bet~eem 0% and 20% load and then a AP increasing linearly to a AP correspond-ing to 110% of full steam flow at full load Ta g 2_ 543°F 2_ ~00 psig steam line pressure Not Applicable Not Applicable

< 24 psig

< A Junction defined as follows:

A /),p corresponding to 44% of full steam flow between 0% and 20% load and then a AP increasing linearly to a AP corresponding to 111.5% of full steam flow at fu 11 load Ta g 2_ 541 °F 2_ ~80 psig steam line pressure

c:: z H

t-3 w

I w

of::>

TABLE 4.3-2 (Continued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL FUNCTIONAL UNIT CHANNELS CHANNEL FUNCTIONAL CHECKS CALIBRATION TEST

3.

CONTAINMENT ISOLATION

a. Phase 11A 11 Isolation
1) Manual N.A.

N.A.

R

2)

From Safety Injection N.A.

  • N.A.

M(2)

Automatic Actuation Logic

b. Phase 11B 11 Isolation
1) Manual N.A.

N.A.

R

2) Automatic Actuation Logic N.A.

N.A.

M(2)

3) Containment Pressure--

s R

M(3)

High-High

c. Containment Ventilation Isolation
1)

Manual N.A.

N.A.

R

2)

Automatic Actuation Logic N.A.

N.A.

M(2)

3)

Containment Ra di oact i vi ty per table 4.3-3 High MODES IN WHICH SURVEILLANCE REQUIRED 1, 2, 3,.

1, 2, 3, 4 1, 2, 3' 4 1, 2, 3 ' 4 1, 2, 3 1, 2, 3,,_

i,*2, 3, 4

(/)

TABLE 3.3-6

t:"

t"-i trj RADIATION MONITORING INSTR UME NTA TI ON

~

c::::

Ml NIMUM z

H INSTRUMENT CHANNELS APPL IC ABLE ALARM/TRIP MEASUREMENT 8

0 PERABLE MODES SET POI NT RANGE ACTION l'V

1.

AREA MONITORS

a.

Fuel Storage Area - R5/R9 1

< 15 mR/hr 10-l - 104 mR/h r

23

b.

Containment Area - R44 2

1, 2. 3 & 4

< 103 R/hr 1 -

107 R/h r *

2.

PROCESS MONITORS

a. Containment
1)

Gaseous Activity a)

Purge & Pressure-.

1#

6 5_ 2 x background Vacuum Relief and 101 106 cpm 26 w

Isolation - Rl2a 1, 2, 3, 4 & 5 per Specification b). RCS Leakage 3~3.3.9 w

. Detection

- Rl2a 1, 2, 3 & 4 N/A 101 106 cpm 24 I w

~

2)

Air Particulate Activity iol - 106 a)

Purge & Pressure 1

6

< 2 x background cpm 25 Vacuum Relief Isolation - Rlla b)

RCS Leakage 1,2,3&4 N/A 101 - 106 cpm Detection - Rlla

b.

Noble Gas Effluent Monitors

1)

Medium Range Auxiliary 1

1, 2, 3 & 4

< 3.0 x l0-2 uCi/cm3 l0 101 uCi/cm3 26 Building Exhaust System (A la rm only)

(Plant Vent) - R45B

2)

High Range Auxiliary*

1 1, 2, 3 & 4

< 1.0 x 102 uCi/cm3 l0 105 uCi/cm3 26 Bu i l di n g E x ha u st Sys t em

-* (A la rm only)

(Pl ant Vent) - R45C

  • With fuel in the storage pool or building.
  1. The unit vent sampling monitor (R-4lc) may also function in this capacity when the purge/pressure-vacuum relief isolation valves are open.

~

H 1-3 N

2.

INSTRUMENT TABLE 3.3-6 (CONTINUED)

RADIATION MONITORING INSTRUMENTATION MINIMUM CHANNELS APPLICABLE ALARM/TRIP OPERABLE MODES SET POINT PROCESS MONITORS

b.

Noble Gas Effluent Monitors

3) Main Steamline 1/

1, 2, 3 & 4 10 mR/hr Discharge (Safety MS Line

( al a rm o n l y )

Valves and Atmospheric Steam Dumps) - R46

4) Condenser Exhaust 1

1, 2, 3 & 4

< 7.12 x 104 cpm System - R 15 (al arm only)

MEASUREMENT RANGE ACTION 1 - 104 mR/hr 26 I-1 - 106 cpm 26

  • TABLE. 3.3-6 (Continued)

TABLE NOTATION ACTION 23 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, perform area surveys of the monitored area with portable monitoring instrumentation at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

ACTION 24 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, comply with the ACTION requirements of Specification 3.4~6.l.

ACTION 25 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, comply with the ACTION requirements of Specification 3.9.9.

ACTION 26 -

With the. number of OPERABLE Channels less than required by the Minimum Channels OPERABLE requir:ements,. initiate t.he pr.eplanned alternate method of ITXlnitoring the appropriate parameter(s}, within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, and:

SALEM -

UN IT 2

1) eith~r restore the inoperable Channells) to OPERABLE status within 7 days of the event, or
2) prepare and submit a Special Report to the Commission pursuant to Specification 6.9.2 within 14 days following the event outlining the action taken, the cause of the inoperability and the plans and schedule for restoring the system to OPERABLE s*tatus.

3(4 3-40

c:: z H

1-3

. N

1.
2.

TABLE 4.3-3 RADIATION MONITORING INSTRUMENTATION SURVEILLANCE REQJIREMENTS CHANNEL INSTRUMENT CHANNELS SOURCE CHANNEL FUNCTIONAL CHECKS CHECKS CALI BRA TI ON TEST AREA MONITORS

a.

Fuel Storage Area - RS/R9 s

M R

Q

b.

Containment Area - R44 s

M R

Q PROCESS MONITORS

a. Containment Monitors
1)

Gaseous Activity a)

Purge & Pressure s

M R

Q Vacuum Relief Isolation - Rl2a b)

RCS Leakage s

M R

Q Detection - Rl2a

2) Air Particulate Activity.

a)

Purge & Pressure -

s M

R Q

Vacuum Relief Isolation - Rlla b)

RCS Leakage s

M R

Q Detection - Rlla

b.

Noble Gas Effluent Monitors

1)

Medium Range Auxiliary s

M R

Q Building Exhaust System (pl ant vent) - R45B

2)

High Range Auxiliary s

M R

Q Building Exhaust System (plant vent) - R45C

  • With fuel in the storage pool or building.

MODES IN WHICH SURVEILLANCE RE QJIRED 1, 2, 3 & 4 1, 2, 3, 4, 5 & 6 1, 2, 3 & 4 1, 2, 3' 4 & 6 1, 2, 3 & 4 e

1, 2' 3 & 4 1, 2, 3 & 4

c:::: z H

t-3 N

2.

TABLE 4.3-3 (CONTINUED)

RADIATION MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL INSTRUMENT CHANNELS SOURCE CHANNEL FUNCTIONAL CHECKS CHECKS CALIBRATION TEST PROCESS MONITORS

b.

Noble Gas Effluent Monitors

3)

Main Steamline Discharge s

M Q

(Safety va 1 ves &

atmospheric dumps) - R46

4)

Condenser Exh. Sys. - Rl5 s

M R

Q MODES IN WHICH*

SURVEILLANCE REQUIRED 1, 2, 3 &.

1, 2, 3 & 4

.e INSTRUMENTATION ACCIDENT MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.3.7 The accident monitoring instrumentation channels shown in Table 3.3-lla and Table 3.3-llb shall be operable.

APPLICABILITY:

MODES 1, 2, and 3.

ACTION:

a.

As shown in Table 3.3-lla and Table 3.3-llb.

b.

The provisions of Specification 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.3.3.7 Each accident monitoring instrumentation channel shall be demonstrated OPERABLE by performance ~

the CHANNEL CHECK AND CHANNEL CALIBRATION operations at the frequencies shown in Table 4.3-11.

SALEM - UNIT 2 3/4 3-50

TABLE 3.3-lla ACCIDENT MONITORING INSTRUMENTATION

. ~*

TOTAL NO.

REQUIRED N

OF NO. OF INSTRUMENT CHANNELS CHANNELS ACTION

1.

Reactor Coolant Outlet Temperature -

4 (1/loop) 2 1

T HOT (Wide Range)

2.

Reactor Coolant Inlet Temperature -

4 (l/loop) 2 T COLD (Wide Range)

. 3.

Reactor Coolant Pressure (Wide Range) 2 2..

1

4.

Pressurizer Water Level 3 (hot) 2 1

w

5.

Steam Line Pressure 3/Steam Generator 2/Steam Generator 1

w

6.

Steam Generator Water level (Narrow 3/Steam Generator 2/Steam Generator 1

I Ul Range)

I-'

7.

Steam Generator Water Level (Wide 4/(1/Steam Generator) 4 (l/Steam Generator) 1 Range*)

8.

Refueling Water Storage Tank Water 4

2 1

Level

9.

Boric Acid Tank Solution Level 2 ( l/tank) 2 ( 1 /tank) 3

10.

Auxiliary Feedwater Flow Rate 4 (l/Steam Generator) 4 (l/Steam Generator) 4

11.

Reactor Coolant System Subcooling 2*

2*

5 Margin Monitor

12.

PORV Pas it ion Indicator 2/valve**

2/valve**

1

c::: z H

t-3 N

w I

Ul f-'

PJ

13.
14.
15.
16.
17.
18.

TABLE 3.3-lla (CONTINUED)

ACCIDENT MONITORING INSTRUMENTATION TOTAL NO.

OF INSTRUMENT CHANNELS PORV Block Valve Position Indicator 2/valve**

Pressurizer Safety Valve Position 2/valve**

Indicator Containment Pres sure Narrow Range 4

Containment Pres sure - Hide Range 2

Containment Water Level -

2 Wide.Range co*re Exit Thermocouples 65 REQUIRED NO. OF CHANNELS

  • 2/val ve**

2/valve**

2 2

2 4/core quadrant

(*)Total number of channels is considered to be two (2) with one (1) of the charinels being manual calculation by licensed control room personnel using data from OPERABLE wide range Reactor Coolant Pressure and Temperature along with Steam Tables as described in ACTION 5.

ACTION 1

1 e 1

7 7

1

(**)Total number of channels is considered to be two (2) with one (1) of the channels bein.g any a

one (1) of the following alternate means of determining PORV, PORV Block,~r Safety Valve position:

W Tailpipe Temperatures for the valves, Pressurizer Relief Tank Temperature,Pressurizer Relief Tank Level Operable.

w

.i::.

w I

Ul EJ!

TABLE* 3.3-llb ACCIDENT MONITORING INSTRUMENTATION INSTRUMENT

1.

Reactor Coolant Outlet Temperature ~

T HOT (Wide Range)

2.

Reactor Coolant Inlet Temperature -

T COLD (Wide Range)

3.

Reactor Coolant Pressure (Wide Range)

4.

Pressurizer Water Level

5.

Steam Line Pressure

6.

Steam Generator Water Level (Narrow Range).

7.

Steam Generator Water Level (Wide Range)

8.

Refueling Water Storage Tank Water Level

9.

Boric Acid Tank.Solution Level

  • 10.

Auxiliary Feedwater Flow Rate

11.

Reactor Coolant System Subcooling Margin Monitor 12 *. PORV Position,Indicator TOTAL NO.

OF CHANNELS 4 (l/loop) 4 (1/loop) 2 3 (hot) 3/Steam Generator 3/Steam Generator 4/(1/Steam Generator) 4 2 ( 1/tank) 4 (l/Steam Generator) 2*

2/valve**

MINIMUM NO. OF CHANNELS

. ACTION 1

2 1

e 1

2 1

2 l/Steam Generator 2

l/Steam Generator 2

3 (l/Steam Generator) 2 1

2. e 1 ( l/tank) 3 3 (l/Steam Generator) 6 1

6 1

2 J

~

I I

-q 1-3 IV w

w I

lJl I-'

()

TABLE 3.3-llb (CONTINUED)

ACCIDENT MONITORING INSTRUMENTATION TOTAL NO.

MINIMUM OF NO. OF INSTRUMENT CHANNELS CHANNELS ACTION

13.

PORV Block Valve Posi~ion Indicator 2/valve**

1 2

14.

Pressurizer Safety Valve Position 2/valve**

1 Inqicator

15. Containment Pres sure - Narrow Range 4

1 2

16. Containment Pressure Wide Range 2

1 2

17. Containment Water Level -

2 1

2 Wide Range

18.

Core Exit Thermocouples 65 2/core quadrant 2

(*) Total number of channels is considered to be two (2) with one {1) of the channels being manual

~

calculation by licensed control room personnel using data from OPERABLE wide range Reactor Coolant Pressure and Temperature along with Steam Tables as described in ACTION 5.

(**)Total number of channels is considered to be two (2)*with one (1) of the channels being any one (1) of the following alternate means of determining PORV, PORV Block, or Safe~ Valve position:

Tailpipe Temperatures for the valves, Pressurizer R_elief Tank Temperature Pressurizer Relief Tank.

Level Operable.

l-.

TABLE 3.3-lla & b (continued)

TABLE NOTATION ACTION 1 With the number of OPERABLE accident monitoring channels less than the Required Number of Channels shown in Table 3.3-lla, restore the inoperable channel (s) to OPERABLE status within 7 days, or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 2 With the number of OPERABLE accident monitoring channels less than the MINIMUM Number of Channels shown in Table 3.3-llb, restore the inoperable channel (s) to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be

. in HOT SHUTDOWN withih the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 3 With the numbe~ of OPERABLE ch~nnels one less than the Required Number of Channels shown in Table 3.3-lla, operation may proceed provided that the Boric Acid. Tank associated with the remaining OPERABLE channel satisfies all requirements of Specification 3.1.2.S.a.

ACTION 4 With the number of OPERABLE channels one less than the Required Number of Channels shown in Table 3.3.lla, operations may proceed provided that an OPERABLE Steam Generator Wide Range Level channel is available as an alternate means of indication for the Steam Generator with no OPERATABLE Auxiliary Feedwater Flow Rate channel.

ACTION 5 With the number of OPERABLE channels less than the Required Number of Channels show in Table 3.3-lla~

operation may proceed provided that Steam Tables are available in the Control Room and the following Required Channels shown in Table 3.3-lla are OPERABLE to provide an alternate means of calculating Reactor Coolant System subcooling margin:

a.

Reactor Coolant Outlet Temperature - THOT (Wide Range)

b.

Reactor Coolant Pressure (Wide Range)

SALEM - UNIT 2 3/4 3-*Sld

'I TABLE 3.3-lla & b (continued)

TABLE NOTATION ACTION 6 With the number of OPERABLE channels less than the Minimum Number of channels shown in Table 3.3-llb, restore the inoperable channel(s) to OPERABLE status within 7 days, or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 7 With the number of OPERABLE ch~nnels one less than the Required Number of Channels shown in Table 3.3-lla, operation may proceed until the next*

CHANNEL CALIBRATION (which shall be performed upon the next entry into MODE 5, COLD SHUTDOWN).

SALEM - UNIT 2 3/4 3-Sle

I

  • N w

~

w I

Ul N

TABLE 4. 3-11 SURVEILLANCE REQUIREMENTS FOR

.ACCIDENT MONITORING INSTRUMENTATION INSTRUMENT

1. Reactor Coolant Outlet Temperature -

T HOT (Wide Range)

2.

Reactor Coolant Inlet Temperature -

T COLD (Wide Range)

3.

Reactor Coolant Pressure (Wide Range)

4.

Pressurizer Water Level

5.

Steam Line Pressure

6.

Steam Generator Water Level (Narrow Range)

7.

Steam Generator Water Level (Wide Range) 8 *. Refueling Water Storage Tank Water Level

9.

Boric Acid Tank Solution Level

10. Auxiliary Feedwate_r Fl ow Rate
11. Reactor Coolant System Subcooling Margin Monitor CHANNEL CHECKS M

M M

M M

M M

M M

SU#

M CHANNEL CALIBRATION R

R R

R R

R R

R R

R N/A*

  1. Auxiliary Feedv1ater System is used on each startup and flow' rate indication is verified at that time.
  • The instruments used to develop RCS subcooling margin are calibrated on an 18 month cycle; the monitor will be compared quarterly with calculated subcooling margin for known input values.

CHANNEL FUNCTIONAi TEST NA NA NA NA NA NA NA NA '

NA

~.

~.

~

TABLE 4.3-11 {CONTINUED}

SURVEILLANCE REQUIREMENTS FOR ACCIDENT MONITORING INSTRUMENTATION.

f-3 CHANNEL N

CHANNEL CHANNEL

  • FUNCTIONA INSTRUMENT CHECK CALIBRATION TEST-

'i 2 ~

PORV Position Indicator M

NA Q

13.

PORV Block Valve Position Indicator M

NA f4.

Pressurizer Safety Valve Position M

NA R

Indicator

15. Containment Pres sure - Narrow Range M

NA NA

16. Containment Pres sure - Wide Range M

R NA w

.i::.

17. Containment Water Level -

M R

NA w

Wide Range I

lJl N

Ill

18.

Core Exit Thermocouples M

R

  • NA

' "~

INSTRUMENTATION RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.3.9 The radioactive gaseous effluent ITX)nitoring instrumentation channels shown in Table 3.3-13 shall be OPERABLE with their alarm/trip setpoints set to ensure that the limits of Specification 3.11.2.1 are not exceeded.

The alarm/trip setpoints of these channels shall be determined in accordance with the (ODCM).

APPLICABILITY:

As shown in Table 3.3-13 ACTION:

a.

With a radioactive gaseous effluent monitoring instrumentation channel alarm/trip setpoint less

. conservative than required by the above specification, without delay suspend the release of radioactive g.aseous effluents monitored by the affected. channel or declare.

the channel inoperable or change the setpoint so it is ac~eptably conservative.

b.

With less than the minimum number of radioactive gaseous effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 3.3-13. Exert best efforts to return the instrument to operable status within 30 days and, if unsuccessful, explain in the next semi-annual radioactive effluent release report why the inoperability was not corrected in a timely manner.

c.

The provisions of Specifications 3.0.3, 3.0.4, and 6.9.1.9.b are not applicable.

SURVEILLANCE REQUIREMENTS 4.3.3.9 *Each radioactive gaseous effluent ITX)nitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CALIBRATION, AND CHANNEL FUNCTIONAL TEST operations at the frequencies shown in Table 4.3-13.

SALEM - UN IT 2 3/4 3-59

c:: z H

1-3 N

w w

I

°'

0 TABLE 3. 3-13 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION INSTRUMENT

1.

WASTE GAS HOLDUP SYSTEM

a.

Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of ~elease (2-R41C) *

b.

Oxygen Monitor

2.

CONTAINMENT PURGE AND PRESSURE - VACUUM RELIEF

3.
a.

Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release (2-R41C or 2-Rl2A)

PLANT VENT HEADER SYSTEM#.

a.

Noble Gas Activity Monitor. (2-Rl6 or 2-R41C)

b.

Iodine Sampler

c. Particulate Sampler
d.

Flow Rate Monitor

e.

S~mpler Flow Rate Monitor MINIMUM CHANNELS OPERABLE 1

1 1

1 1

1 1

1 APP LI CABI L ITV

  1. The following process streams are routed to the plant vent where they are effectively monitored by the instruments described:

(a) Condenser Air Removal System (b) Auxiliary Building Venti.lation System (c) Fuel Handling Building Ventilation System (d) Radwaste Area Ventilation System (e)

Contain~ent Purges Action item #34 applies to the purging of the containment only.

  • I ACTION 35 34 33 36

-36 32 32

I -

I I *f I

,, ~

M TABLE 3.3-13 (Continued).

TABLE NOTATION ACTION 31 -

With the number of channels OPERABLE less than required by the Mini mum Channels OPERABLE requirement, the contents of the tank(s) may be released to the environment provided that prior to initiating the release:

a.

At-least two independent samples of the tank 1s contents are analyzed, and

b.

At least two technically qualified members of the Facility Staff independently verify the release rate calculations and discharge valving lineup; Otherwise, suspend release of radioactive effluents via this pathway.

ACTION 32 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE-requirement, effluent releases via this pathway may continue provided the flCM rate is estimated at least once.per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

ACTION 33 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided grab samples are taken at least once pe~ 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and these samples are analyzed for gross activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

ACTION 34 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, immediately suspend PURGING of radioactive effluents via this pathway.

  • At all times, other than when the line is valved out and locked.

_** During waste gas holdup system operation.

      • During containment purges or containment pressure -

vacuum reliefs.

SALEM - UNIT 2 3/4 3-61.

TABLE 3.3-13 (Continued)

TABLE NOTATION ACTION 35 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, operation of the waste gas holdup system may continue provided grab samples are collected at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and analyzed within the following 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

ACTION 36 -

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided samples are continuously collected with auxiliary sampling equipment as required in Table 4.11-2.

SALEM - UNIT 2 3/4 3-62

c: z H

t-3 w

I

°'

w TABLE 4. 3-13 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS INSTRUMENT

1.

WASTE GAS HOLDUP SYSTEM

a.

Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release (2-R41C)

b.

Oxygen Monitor

2.

CONTAINMENT PURGE AND PRESSURE - VACUUM RELIEF

a.

Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release (2-R41C or 2-R12A)

3.

PLANT VENT HEADER SYSTEM#

a.

Noble Gas Activity* Monitor (2-R 16 or 2-R41C)

b.

Iodine Sampler

c. Particulate Sampler
d.

Flow Rate Monitor

e. Sampler Flow Rate Monitor
  1. The following process streams are routed to the plant the instruments described:

(a) Condenser Air Removal System (b) Auxiliary Building Ventilation System (c) Fuel Handlirig Building Ventilation System (d)

Radwaste Area Ventilation System

. ( e) Containment Purges CHANNELS OPERABLE p

D p

D w

~J D

w SOURCE CHECK p

N.A.

p M

N.A.

N.A.

N.A.

N.A.

CHANNEL CHANNEL FUNCTIONAL CALIBRATION TEST R(3)

Q(l)

Q(4)

M R(3)

Q(l)

R(3)

Q(2)

N.A.

N.A.

N.A.

N.A.

R N.A.

R N.A.

vent where they are effectively monitored by MODES IN WH IC SURVEILLANCE REQUIRED

    • e
  • e

41

~.,I TABLE 4.3-13 (Continued)

TABLE NOTATION (1)

The CHANNEL FUNCTIONAL TEST shall also demonstrate that automatic isolation of this pathway and control room alarm annunciation occurs if any of the following conditions exist:

1.

Instrument indicates measured levels above the alarm/trip setpoint.

2.

Circuit failure.

(Loss of Power)

3.

Instrument indicates a downscale failure.

(Alarm Only)

(2)

The CHANNEL FUNCTIONAL TEST shall also demonstrate that control room alarm annunciation occurs if any of the following conditions exist:

1.

Instrufllent indicates measured levels above the alarm/trip setpoint.

2.

Circuit failure.

(Loss of Power)

3.

Instrument indicates a. downscale failure.

4.

Instrument controls not set in operate mode.

(3)

The initial CHANNEL CALIBRATION was performed using appropriate liquid or gaseous calibration sources obtained from reputable suppliers.

The activity of the calibration sources were reconfirmed using a multi-channel analyzer which was calibrated using one or more NBS standards.

(4)

The CHANNEL CALIBRATION shall include the use of standard gas samples containing a nominal:

1.

One volume percent oxygen, balance nitrogen, and

2.

Four volume percent oxygen, balance nitrogen.

  • At all times
    • During waste gas holdup system operation *.
      • During containment purge or containment pressure -

vacuum reliefs

  • SALEM - UNIT 2 3/4 3-64.

I.