ML18087A638

From kanterella
Jump to navigation Jump to search
Advises That NRC Unable to Determine Acceptability of 821203 Request to Modify Fuel Enrichment to 4.05% by Weight U-235, Based on Info Provided.Request for Addl Info Encl.Info Needed to Meet 830128 Target Date for Review Completion
ML18087A638
Person / Time
Site: Salem  
Issue date: 01/21/1983
From: Varga S
Office of Nuclear Reactor Regulation
To: Uderitz R
Public Service Enterprise Group
References
NUDOCS 8301260272
Download: ML18087A638 (3)


Text

Docket Nos. 50-272 and 50-311 Mr. R. A. Uderitz Vice President - Nuclear Public Service Electric and Post Office Box 236 Hancocks Bridge~ New Jersey

Dear Mr. Uderitz:

Gas Company 08038 DISTRIBUTION Dockets NRC PDR L PDR NSIC ORB#l Rdg DEisenhut OELD JMTaylor ELJordan ACRS-10 CParrish DFischer Gray

SUBJECT:

REQIJEST 10".: MODIFY THE FUEL ENRICHMENT FOR THE REACTOR CORES AND THE NEW AND SPENT FUEL RACKS TO 4.05 HEIGHT PERCENT U-235 The staff has reviewed the information provided in your submittal dated December 3 !) 1982.

We are unable to determine the acceptability of your request to modify fuel enrichment to 4.05 weight percent U-235 based on the information provided and request additional clarification.

We will complete our review and issue a final Safety Evaluation upon resol-ution of the concerns identified in the enclosure.

The completion target date for our review is January 28, 1983.

In order for us to meet this date, it is necessary that your response to this 1 etter receive immediate attention.

Enclosure:

Request for Additional Infonnation cc w/enclosure:

See next page

-~8301260272 830121 PDR ADOCK 05000272 p

PDR OR&Jt.l :-Pk?

L Sincerely~

l(k!gfoal fSignoo eyg L~Q A.. V'a.rga Steven Ai Varga, Chief Operating Reacto~s Branch #1 Division nf Licensing

\\ \\

i '.

\\

"\\' \\

\\\\

(

OFFICE.,.********~~*

SURNAME ***** P.f.J.?.~h~r..:.~

DATE *

  • *** a J. /..f1.'/. a 1....... Q.11 NRG FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-335-960

/..

  • -~

Mr. R. A. Uderitz Public Service Electric and Gas Company cc:

Mark J. Wetterhahn, Esqufre

-Conner and Wetterhahn Suite 1050 1747 Pennsylvania Avenue, NW Washington, D. C.

20006 Richard Fryling, Jr., Esquire Assistant General Solicitor Public Service Electrjc and Gas Company Mail Code TSE - P.O. Box 570 Newark*, New Jersey 07101 Gene Fisher, Bureau of Chief Bureau of Radiation Protection 380 Scotch Road Trenton', New Jersey 08628 Mr. R. L. Mittl, General Manager Corporate Quality Assurance Public Service Electric and Gas Company Mail Code Tl6D - P.O. Box 570 Newark, New Jersey 07101 Mr. Henry J. Midura, Manager Salem Operations Public Service Electric and Gas Company P. O. Box 168 Hancocks Bridge, New Jersey 08038 Leif J. Norrholm, Resident Inspector Salem Nuclear Generating Station

u. S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, New Jersey 08038 Mr. Edwin A. liden, Manager -

Nuclear Licensing Public Service Electric and Gas Company Mail Code Tl6D - P.O. Box 570 Newa*rk; New Jersey 07101 Ronald c. Haynes Regional Administrator - Region I

u. s. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. Charles P. Johnson Assistant to Vice President - Nuclear Public Service.Electric and Gas Company P. 0. Box 570 80 Park Plaza - 15A Newark, New Jersey 07101

/.*

r.

REQUEST FOR ADDITIONAL INFORMATION MODIFICATION OF FUEL ENRICHMENT

. ENCLOSURE

1.

The enrichment of the 17xl7 Westinghouse fuel assemblies in the new fuel storage rack is stated as 4.5 w/o U-235 in Section 2.a of although the Technical Specifications limit the reload fuel enrichment to 4.05 w/o.

Please correct this discrepancy.

2.

With respect to the optimum moderation event in the new fuel storage racks, what procedures and/or des.ign features preclude lower densities (e.g., 1%-10% of full density) which may result in higher reactivities? Provide any available calculational results or *references which support your conclusion that physically achieva-ble water densities are considerably too low to yield keff values higher than full density water.

3.

Technical Specification 5.6.l refers to a conservative allowance of 2.2% t,k/k for uncertainties in predicting keff' However, an allowance of 1.5% ilk/k is used in the new fuel rack analysis.

Please correct this discrepancy.