Forwards Response to NRC 810608 Safety Evaluation for Environ Qualification of Electrical Equipment.Qualification Testing & Equipment Replacement Should Be Completed by 820630
ML18086A934
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/10/1981
From: Mittl R
Public Service Enterprise Group
To: Varga S
Office of Nuclear Reactor Regulation
References
IEB-79-01B, IEB-79-1B, NUDOCS 8109220508
Download: ML18086A934 (118)


Text

{{#Wiki_filter:' -. Public Service Electric and Gas Company 80 Park Plaza, T16D Newark, N.J. 07101 201/430-8217 Robert L. Mittl General Manager - Licensing and Environment September 10, 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20014 Attention: Mr. Steven A. Varga, Chief Operating Reactors Branch 1 Division of Licensing Gentlemen: ENVIRONMENTAL QUALIFICATION PROGRAM NO. 1 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 PSE&G hereby submits, in the enclosure to this letter, its response to the NRC Staff's Safety Evaluation for the envi-ronmental qualification of safety-related electrical equip-ment, transmitted to us by your letter dated June 8, 1981. This report responds to the action items identified in the safety evaluation. Our Environmental Qualification Review Report, its subsequent revisions, in-house documentation, and this report provide the needed information to support the safe operation of Salem 1. Immediate corrective action has been taken where necessary. The staff concerns have been resolved through procedure changes, design changes, and clarification information in this report. Final resolution of some items will occur when equipment replacement is com-plete. We believe that Salem 1 can continue to operate in a safe manner pending equipment replacement where necessary. While there is some environmental testing now in progress, we anticipate completion of the qualification testing and installation of replacement equipment by June 30, 1982 sub-ject to the availability of a plant outage of sufficient duration. ,---8109220508 810910 -. PDR ADOCK 05000272 p PDR The Energy People

Director of Nuclear Reactor Regulation

  • 9/10/81 Should you have any questions in this regard, do not hesi-tate to contact us.

CC: Mr. Leif Norrholm Senior Resident Inspector Mr. Gary Meyer - Licensing Project Manager ER03 1/2

SEPTEMBER 1981 he Energy People SALEM GENERA TING ST A TION UNIT NO. 1 ENVIRONMENT AL QUALIFICATION OF SAFETY - RELATED ELECTRICAL EQUIPMENT PSE&G RESPONSE. TO NRC SAFETY. EVALUATION REPORT OF JUNE 8,1981

SALEM GENERATING STATION UNIT NO. 1 ENVIRONMENTAL QUALIFICATION OF SAFETY-RELATED ELECTRICAL EQUIPMENT PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT OF JUNE 8, 1981 September 1981

I. I I. TABLE OF CONTENTS

SUMMARY

/CONCLUSIONS ITEMS FROM SECTION 3 OF NRC SAFETY EVALUATION III. ITEMS FROM SECTION 4 OF NRC SAFETY EVALUATION A. NRC Noted Deficiencies of Appendix B B. NRC Noted Deficiencies of Appendix C REFERENCES i -

I.

SUMMARY

/CONCLUSIONS The Nuclear Regulatory Commission Safety Evaluation Report (June 8, 1981) on Environmental Qualification of Safety-Related Electrical Equipment at Salem Generating Station Unit 1 requires that the licensee provide additional information to respond to general concerns regarding the Salem environmental qualification review program and noted deficiencies for specific pieces of equipment. Their Safety Evaluation Report is based on a review of the Salem Environmental Qualification Review Report - Revision 1 dated December 1, 1980. Two revisions (January 16, 1981 and February 9, 1981) have been issued which update the Salem report with results of the Aging Evaluation Review, the TM! Action Items and Cold Shutdown Equipment. The Staff did not have the benefit of this material, which does address some of the deficiencies cited, in their review. Public Service Electric and Gas Company has reviewed the Safety Evalua-tion Report and has provided the requested additional information in the following pages. Responses have been made to the action items of the Staff and evaluations prepared of identified deficiencies for specific equipment. Our Environmental Qualification Review Report, subsequent revisions, in-house documentation and this report provides the needed information to support the safe operation of Salem Unit 1. Immediate corrective action has been taken where deemed necessary for plant safety. The Staff concerns have been resolved through procedure changes, design changes and clarifying information in this report. Final resolution of some items will occur when equipment replacement is complete. We believe that Salem Unit 1 can continue to operate in a safe manner pending equipment replacement.

II.

  • ITEMS FReJ.1 SECTION 3 OF NRC SAFETY EVALUATION Section 3 of the NRC Safety Evaluation Report presents a general over-view of the Staff's review of the Salem Generating Station Environ-mental Qualification Review Report {Rev. 1 - 12/1/80). Major topics such as equii:ment identification, test profiles, submergence. aging.

etc., are discussed along with Staff conclusions. In addition seven (7) itens were singled out to be specifically addressed by the licensee. A. Section 3.1, page 3 - Completeness of Safety-Related Eguii:xnent "Display instrumentation which provides information for the reactor operators to aid them in the safe handling of the plant was not specifically identified by the licensee. A complete list of all display instrumentation mentioned in the LOCA and HELB emergency procedures must be provided *** (1) justifica-tion should be provided for not considering the instrument safety-related and (2) assu~ance should be provided that its subsequent failure will not mislead the operator or adversely affect the mitigation of the consequences of the accident." Display instrumentation mentioned in the Emergency Operating Pro-cedures was included as part of the Salem environmental qualifi-cation review effort. This instrumentation was included in the master list and evaluation fonns under the applicable systens. For example, steam generator level is included under Main Steam. A separate listing of all the primary instruments and attendant cables, panels, tenninal blocks, etc., was not deemed necessary since all the devices were included in the systen perfonning the function. Other devices which do not perform a system safety function were included under "Contai!'llllent Parameters" or 11Mis-cellaneous11 in Section IV of the report. In the next revision to the Salem Envirol'JTlental Qualification Report, a cross-indexing of display instrumentation will be provided. Those instrumentation items which were included in the Emergency Operating Procedures but are not required for any operator action do not require environmental qualification. The operating pro-cedures-have been revised to reflect potential inaccuracy of the devices. The operators will be aware of their potential failure. A discussion of these items was provided in the following Bases of Section VII of the report: 188,~21, 23, 29, 33 and 37. 3

B. Section 3.3, page 4 - Temperature, Pressure and Humidity Conditions Inside Containment 11 *** the licensee has used a lower temperature profile for some components based on a Wyle Laboratory Report (44439-2 Revision A). The licensee should submit this report or a summary of the report for staff review. The summary should describe the basis for accepting the lower temperature profile. 11 Wyle Labs Report 44439-2 for Salem Generating Station instrument panel testing has already been submitted to the NRC Staff. Ten (10) copies of the original issue of 44439-2 were sent by letter, Mr. R. L. Mittl, PSE&G to Mr. Olan D. Parr, NRC on Ap.Fil 12, 1979 and ten (10) copies of Revision A of 44439-2 were sent by letter, Mr. R. L. Mittl, PSE&G to Mr. Olan D. Parr, NRC on October 23, 1979. A lower temperature profile for some items was established due to their location within instrument panel enclosures inside the con-tainment. The peak containment temperature for exposed equipment is 350°F. The instrument panel testing demonstrates that when the containment temperature is 350°F, equipment within the panels see temperatures less than 300°F. This is due to the thermal protec-tion afforded by the instrument panel during the initial tempera-ture rise transient. C. Section 3.5, page 5 - Submergence 11The licensee proposes procedural modifications for some cases and indicates that the functional requirements of the poten-tially submerged components will be completed prior to submer-gence. The licensee should provide an assessment of the failure modes associated with the submergence of components. Assurance should also be provided that the subsequent failure of these components will not adversely affect any other safety functions or mislead an operator. Additionally, the licensee should discuss operating time, across the spectrum of events, in rela-tion to the time of submergence. 11

An evaluation of submerged components and their effect on other equipment and safety functions was performed with the results pre-sented in the response to FSAR Question 6.28. The safety of the plant would not be jeopardized by the submerged components. As part of the environmental qualification review effort, submerged components were reevaluated to assure the safety function was per-fonned prior to submergence. In all cases this would be accom-plished in a timely fashion prior to submergence. Bases 28 and 29 provide the discussion of this topic in our report. Supporting documentation is included with our environmental qualification files in the corporate home office. D. Section 3.5, page 5 - Submergence 11It is not clear from the information submitted that submergence of safety-related electrical equipment outside of containment was addressed. The licensee should address this area... and upgrade the CES (component evaluation sheet) as appropriate. 11 A high energy line break analysis was performed for equipment out-side the containment at Salem. This analysis did not identify flooding outside the containment as a safety concern. This was due to the use of drains outside the containment to take care of leakage, encapsulation of piping to limit mass release from breaks and direct it to acceptable areas and that major pipe breaks are in areas which are provided with relief panels to direct the mass release to the atmosphere. The high energy line break analysis is described in FSAR Section 14.5. Therefore, submergence of safety-related equipment outside the containment was not specifically addressed in the previous report. E. Section 3.6, page 5 - Chemical Spray 11The exact volume percent used by the vendors for qualification testing should be verified by the licensee.a'

The environmental qualification review of the acceptability of chemical spray testing of equipment was based on the use of boric acid and sodium hydroxide in a solution creating a pH of greater than 8.5 for a duration greater than 22.5 hours. F. Section 3.7, page 6 - Aging 11 *** the staff requires that the licensee submit supplemental information to verify and identify the degree of conformance to the above requirements. (establishment of an ongoing program to review surveillance and maintenance records and component maintenance and replacement schedules). The response should in-clude all the equipment identified as required to maintain func-tional operability in harsh environments. 11 The Salem Aging Evaluation Program is described in Section X of the report. This information was included in Revision 2 update issued* 1/16/81. Maintenance or replacement schedules were established for selected equipment based on this review. This information has been included in revised Qualification Evaluation Data Forms where appropriate in Section V of the report. In our discussion we in-dicated that aging evaluation is an ongoing effort as part of the surveillance programs for safety-related equipment and activities of the industry by the PWR ~nd BWR owners groups, EPRI, licensee event reports, new testing and NRC Bulletins and Circulars. This information will be factored into an overall aging program. G. Section 3.8, page 6 - Radiation (Inside and Outside Containment) 11 *** the minimum value for inside containment has not been pro-vided. The minimum value m~y not envelope the minimum require-ments of NUREG-0588. Therefore, the licensee is requested to either provide justification for using the lower value or pro-vide values established using the methodology of NUREG-0588. 11

We are unaware of any m1n1mum radiation value used to establish adequate environmental qualification. The maximum value of 5 x 107R has been used as the benchmark for qualification review. The Staff has established a different method for radiation exposure calculation for the Reactor Coolant System Temperature Monitors (RTD 1s). We have indicated that these will be replaced each refuel-ing outage pending installation of qualified devices meeting Staff requirements. This item was established in NRC Safety Evaluation for Salem Supplement 4 dated April, 1980. After reviewing the items contained in this section, PSE&G reaffirms its statements made in our March 6, 1981 letter, Mr. F. W. Schneider, PSE&G to Mr. T. M. Novak, NRC. The necessary immediate corrective actions for plant safety have been made assuring that Salem Unit 1 can continue to operate in a safe manner pending equipment replacement. z

III. ITEMS FROM SECTION 4 OF NRC SAFETY EVALUATION Section 4 of the NRC Safety Evaluation Report presents details of the Staff 1s review of specific equipment included in the Salem Generating Station Environmental Qualification Review Report. Based on the Staff 1s review of Equipment Qualification Evaluation Data Forms, three categories of equipment deficiencies were established. - Equipment Requiring Immediate Corrective Action no Salem Unit 2 equipment is in this category - Equipment Requiring Additional Information and/or Corrective Action a list of equipment with specific deficiencies for Salem Unit 2 was included as Appendix B of the Safety Evaluation Report - Equipment Considered Acceptable or Conditionally Acceptable ~ list of equipment for Salem was included as Appendix C of the Safety Evaluation Report The categorization of equipment was based on deficiencies cited by the NRC in their review of Revision 1 to the Salem Environmental Qualifica-tion Review Report (12/1/80). Two revisions have been issued to update the report which, in many instances, address the items identified in the Staff review. The deficiencies resulted fr001 a screening criteria established for the NRC review and do not imply an unsafe condition but rather a need for additional information and/or clarification of the data provided. The following sections provide an evaluation of the specific deficiencies identified by the Staff. After reviewing the NRC identified deficiencies for equipment in this section, PSE&G reaffirms its statements made in our March 6, 1981 letter, Mr. F. W. Schneider, PSE&G to Mr. T.. M. Novak, NRC. The necessary immediate corrective actions for plant safety have been made assuring that Salem Unit l can continue to operate in a safe manner pending equipment replacement.

III.A. NRC Noted Deficiencies of Appendix B The attached information provides an evaluation of each NRC identified deficiency for specific components/equipment. Cross referencing to existing information in the Salem Environmental Qualification Review Report is provided where appropriate due to the two revisions issued since the NRC review effort. Clarifying statements and reference to documentation contained in the Qualification Documentation Files in the corporate home office is also provided. Replacement schedules for equipment are provided where this method is employed for final re so 1 u ti on.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT RTD (Rosemount, Inc.) MODEL: 176 KS COMPONENT NO.: TA0043, TA0053, TA0063, TA0073, TA2757, TA2758, TA2759, TA2760 NRC IDENTIFIED DEFICIENCIES: RT, QT, CS, RPS E&G EVALUATION OF DEFICIENCIES: Our submittal, Volume 1, Section V, page :Z.addresses all the above NRC noted deficiencies. Supporting data referenced is available in our file EQ-10. RTD 1s at Salem are being replaced every outage pending requalification by the manufacturer to more conservative guidelines dictated by NRC in letter dated 1 10/13/79. f>~f'f-{'. P..l~.s. i-o in::rf-""'!l -9"'-lly '1."'~liPic.c;{ RT"i:>':S by G/3o/g2._ cilectol 1'""e.. pe.r- \\ i c.£1\\ ":5 lt'\\el r-e.. "'"cA. ~,..~e..r'\\ 1-: PSE&G 1s evaluation of NRC noted deficiencies has reaffirmed that plant safety is not jeopardized pending a permanent solution to the problem

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT MODEL:

COMPONENT NO.: NRC IDENTIFIED-DEFICIENCIES: E&G EVALUATION OF DEFICIENCIES: .Tn le" /,*o" a I fy. 1.~lt B /"'"I< I/, --

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Solenoid Valves (ASCO) MODEL: FT8321A2 COMPONENT NO.: (SV0269, SV0279, SV0278, SV0288, SV0578, SV0581, SV0585, SV0583) (Unit I Only) NRC IDENTIFIED *oEFICIEtKIES: RPN E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Data Form page 18A. These solenoid valves will be replaced with qualified valves prior to 6/30/82, as they become available. Our submittal, Volume I, Section VII, basis BA and BC gives this schedule and our justification for continued operation. Further supporting data is* in our file EQ-12. PSE&G's evaluation of this NRC noted deficiency has reaffirmed that plant safety is not jeopardized pending replacement. 12 -

.IPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO N~C SAFETY EVALUATION REPORT Solenoid Valves (ASCO) MODEL: FT8321A4 COMPONENT NO.: SV0274, SV0275, SV0280, SV0281, SV0270, SV0271, SV0284, SV0285 NRC IDErHIFIED DEFICirnCIES: RPN E&G EVALUATIOfi OF DEFICIUJCIES: Ref. Qualification Data Evaluation Form, page 41. These solenoid valves will be replaced with qualified valves prior to 6/30/82, Our submittal, Volume 1, Section VII, basis BB gives this schedule ana our-justification for continued operation. PSE&G's evaluation of this NRC noted deficiency has reaffirmed that plant safety is not jeopardized pending replacement. /3

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .UIPMENT: Solenoid Valves {ASCO) MODEL: X8342B22 COMPONENT NO. : SV1120 SV1121 SV1122 SV1123 SV1124 SV1115 SV1116 SV1117 SV1118 SV1119 NRC IDENTIFIED-DEFICIENCIES: RT, RPS E&G EVALUATION OF DEFICIENCIES: SV0621 SV0624 SV0627 SV0630 SV0633 Ref. Qualification Data EYaluation Form, page 92. J_h_e~e _s_oJ~no}9__y~l_y_~s ~i.11 be replaced with qualified valves prior to 6/30/82.

  • Our submittal, Volume 1, Section VII, basis 19 give-$ thfs _s_ctie.Ciuie.. and our justification for continued operation.

PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Solenoid Valves (ASCO) MODEL: NP. Series COMPONENT NO.: SV0491, SV0492, SV0493, SV0427, SV0518, SV0519, SV0520, SV0521, SV0399, SV0397, SV0401 NRC IDEtHIFIED "DEFICIENCIES: RT, A, CS, S E&G EVALUATION OF DEFICIEtlCIES: Ref. Qualification Data Evaluation Form, Page 60. RT, CS - All NP series valves are fully qualified for adverse environmental ~ conditions. All NRC noted deficiencies are addressed in our sub-mittal. All supporting information for these valves is contain in our file EQ12. A - These valves are qualifi~d for a 40 year life provided coils and elastomers are replaced every 4.4 years. S - These valves perform their function.prior to being submerged. Basis 28 in Volume 1, Section VII states our position. PSE&G 1s evaluation of NRC noted deficiencies has reaffirmed that ASCO NP series valves are capable of performing safety functions in a harsh environment * /?

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT EQUIPMENT: Limit Switches (Namco) MODEL: EA-180 COMPONENT NO.: 1CV3, 1CV4, lCVS, 1SJ123, 1WL98 NRC IDENTIFIED DEFICIENCIES: A, S, T, CS PSE&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 61. A - The aging evaluation review was completed with maintenance schedules established. This information was added to the Evaluation Form in Revision 2. S - The submergence issue was addressed in our submittal Procedure changes were made to correct this problem. precludes installation of switch above flood level. of these switches does not affect plant safety. Section VII, basis 29. Physical location The potential flooding T - The actual test resulted in a peak temperature of 349°f, for 3-hours. The Salem required profile is 3S0°F for one minute. This is more than adequate to assure operability at Salem. CS - This item was addressed in our submittal..

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Limit Switch (Masoneilan) MODEL: 496-2 COMPONENT NO.: ~' ~' 13MS7, 13MS7 NRC IDENTIFIED* DEFICIENCIES: EXN, RPS E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Fonn page 20. These limit switches will be replaced with qualified switches prior to 6/30/82.


Our submittal, Volume I, Section VII, basis lOA states 1

-_~gu*r-:: f nten-tj Ciri.$ *in9-f~_as9-n1 ng __ fQr continued operation. -~:-_-- --~-- ---~~ :~---~- ---~-----~-~--~~--~~-- PSE&G's evaluation of these NRC noted defi"ciencies has reaffirmed that plant safety is not jeopardized pending replacement

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT:

Limit Switch (Masoneilan) MODEL: 496-2 COMPONENT NO.: 11GB4, 12GB4, l3GB4, 14GB4 NRC IDENTIFIED-DEFICIENCIES: EXN, RPS ~E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 44 These limit swi~ch~~ will be replaced with qualified switches prior to 6/30/82. Our submittal, Volume I; Section VII, basis 18A states -~u-fJ~te:n:~l~~~~-a-n~ __ !ea_san} ng _f_Qr continued operation. -__ -: _- _- ---_ ~--~-~--- -~ ~--:-~~-~--= PSE&G's evaluation of these, NRC noted, deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT e!PMENT: Limit Switches (Namco) MODEL: D-2400X COMPONENT NO.: 1CC215, 1CC113, 1SJ53, 1SJ60, 1NT32, 1SS49, 1SS64, 1SS33, 1SS27, 1VC8, lVClO, 1VC12, 1VC14 NRC IDENTIFIED *DEFICIENCIES: A, RPN .&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 45. These limit switches will be replaced with qualified switches prior to 6/30/82. Our submittal, Volume I, Section VII, basis 18A stat~s our intentipns and reasoning for continued operation. PSE&G's evaluation of these. NRC Noted deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .UIPMENT: Limit Switches (Namco) MODEL: EA-170, D2400X COMPONENT NO.: SJ78, SJ79, SJ108 . NRC* IDENTIFIED-OEFICIENCIES: RT, RPS E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form pages 56 and 90.

  • rhese limit switches will be replaced with qualified switches prior to 6/30/82.

., Our submittal, Volume I, Section VII, basis 26 sta_tes.. qu~j-~tji!-nJ1_qijs_-__ ~ri~- l'.'~Ci~on_if)9 f~r_continued operation. --* __ -:* -- PSE&G' s evaluation of these NRC noted deficiencies has reaffirmed that pl_ant safety is not jeopardized pending replacement.

.IPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NR~ SAFETY EVALUATION REPORT Pressure Transmitter (Barton) MODEL: 332/351 COMPONEtff NO.: PA2344, PA2345, PA2346, PA2568 NRC IDENTIFIED D_EFICIENCIES: RT, R, RPS G EVALUATION OF DEFICIENCIES: . Qualification Data Evaluation Form page 52. The subject transmitter will be replaced with a qualified unit prior to 6/30/82. Our submittal, Volume I, Section VII, basis 22 details our intensions and gives our reasons for continued operation.. PSE&G's evaluation of these NRC noted deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. 20

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT 1PMENT: Pressure Transmitter (Rosemount) MODEL: 1153AGA COM?ONENT NO.: PA0667, PA0671, PA0734, PA0670, PA0674, PA0736, PA0668, PA0672, PA0738, PA0669, PA0673, PA0740 NRC IDEtHIFIED DEFICIENCIES: QT, RT, A G EVALUATION OF DEF1CIENCIES: Ref. Qualification Data Evaluation Form page 16. .QI, RT - The data in our submittal states a time of ( 10 days). This doesn't meet the 14 days requirement. This value is based on a MSLB in the inboard/outboard penetration. The break will affect transmitters in that area alone (inboard or outboard). Therefore, two steam generator pressures will always be available. Furthermore, after 10 days, any failures can be repaired. A - Regarding aging; these items are considered to have little safety significance for the time frame in question until replacement or evaluation. PSE&G will either determine the qualified life of these transmitters or replace them with qualified ones prior to 6/30/82. Further supporting data is available in our file EQ-11. Our evaluation of the NRC noted deficiencies_ has reaffirmed that plant safety is not jeopardized pending completion of the aging review. Underlined item is a* correction to NRC SER

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT QUIPMENT: Limitorque Motor Operated Valves ODEL: SMB - Class B Insulation (Inside Containment) COMPONENT NO.: 1PR6, 1PR71 11-11' S:T5W. NRC IDENTIFIED DEFICIENCIES: QT, RT, CS, QM, SEN, A PSE&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 63-2 * .QI. - These valves are only required to be operable in the initial stages of the accident (<.1 hour). They have been qualified for 4 hours operation. . RT - The next revision of the EQ submittal will indicate need for short term ~ operability. Additional information regarding these valves for cold shut down purposes was provided in Revision 3, Section XII. CS - In the Franklin Institute Research Laboratories Final Report F-C2232-0l, the chemical environment was obtained by spraying 1.5% wt. boric acid buffered with sodium hydroxide to a pH of 7.67 at a rate of 10 gallons per hour for four hours. At the conclusion of the test a sample of con-densate was drawn and found to have a pH of 8.2. After 144 hours of environmental testing, the geared limit switch failed. The geared limit switch aluminum frame had been attacked by the chemicals in the steam atmosphere. This caused the gear frame to.corrode and resulted in the binding of the shaft. Since the results of this test were known, the geared limit switch and the limit switch housing material at Salem Generat-ing Station has been changed to bronze. An operator equipped with a bronze limit switch housing was retested and passed. The bronze geared limit switch showed no signs of deterioration due to the chemical spray. QM,SEN - During the various environmental tests that were performed on the Limiterque motor operators, certain deficiencies have come to light. Any material or component that has experienced a failure in any of the tests has been replaced with the latest qualified material or component that has success-fully passed. This should preclude any failure due to any identified environmental parameter-in the accident environment condition that was present in the various test environments. A - An aging test was performed by baking the motors at a temperature of 1ao0c for a total of 100 hours to simulate aging the motor. An aging analysis was also performed (results will be included in next revision to EQ submittal). There has not been any tests that have taken the operator to its ultimate failure, but our calculations show that a minimum life of 3.67 years can be expected. Further supporting data is included in our file EQ-29. PSE&G's evaluation has determined that Limitorque motor operators should perform their safety function. We wi11 be pursuing our review effort to further clarify ~the Limitorque testing results.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT: Limitorque Motor Operated Valves MODEL: SMB, Class B Insulation (Outside Containment) COMPONENT NO.: lSJl, 1SJ2, 1SJ4, lSJS, 1SJ12, 1SJ13, 12SJ45, 1CV68, 1CV69,

  • 1CV139, 1CV140, 1CV175, 1CV40, 1CV141, 11SJ113, 12SJ113, 1SJ30, 12SJ40, 11SJ134, 12SJ134, lS 135, 11RH4, 12RH4, 11SJ49,

. 12SJ49, 11RH29, 12RH29, 11RH19, 12RH19, 11CS36, 12CS36, 11CS2, 1CS14, 1CS16, 1CS17, 11CC16, 11CC117, 11CC118, 1CC136, 1CC131, lCV116,liSJ44, 12SJ441 1'SJ"lfS"1 /ISJ"fO NRC IDENTIFIED-DEFICIENCIES: QT, RT, CS, QM, SEN, A E&G EVALUATION'OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 63-2 * .QI. - These valves are only required to be operable in the initial stages of the accident. They have been qualified for 8 hours operation. RT - The next revision of the EQ submittal *will indicate need for short term op er ab il i ty.

  • I t!S - These vctl,,es A,.e lo~ded ootsJe tAe eo"tA'""'e*t '"J not subject to QM,SEN - During the various environmental tests that were performed on the Limitorque motor operators, certain deficiencies have come to light.

Any material or component that has experienced a failure in any of the tests has been replaced with the latest qualified material or component that has success-fully passed. This should preclude any failure due to any identified environmental parameter in the accident environment condition that was present in the various test environments. 2.1 B

A - An aging test was perfonned by baking the motors at a temperature of 1ao0c for a total of 100 hours to simulate aging the motor. An aging analysis was also performed (results will be included in next revision to EQ submittal). There has not been any tests that have taken the operator to its ultimate failure, but our calculations show that a minimum life of 3.67 years can be expected. Further supporting data is included in our file EQ-29. PSE&G 1 s evaluation has determined that Limitorque motor operators should perfonn their safety function. We will be pursuing our review effort to further clarify the Limitorque testing results.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT ~IPMENT: Limitorque Motor Operated Valves MODEL: SMB - Class H Insulation (Inside Containment) COMPONENT NO.: . _.

  • lRHl, 1RH2, 1RH26, NRC IDENTIFIED-DEFICIENCIES:

QT, RT, CS, QM, SEN, A,_ E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 63-1. QI. - These valves are only required to be operable i~ the initial stages of the accident. They have been qualified (, RT - The next revision of the EQ submittal will indicate need for short term operability. CS - In the Franklin Institute Research Laboratories Final Report F-C2232-0l, the chemical environment was obtained by spraying 1.5% wt. boric acid buffered with sodium hydroxide to a pH of 7.67 at a rate of 10 gallons per hour for four hours. At the conclusion of the test a sample of con-densate was drawn and found to have a pH of 8.2. After 144 hours of environmental testing, the geared limit switch failed. The geared limit switch aluminum frame had been attacked by the chemicals in the steam atmosphere. This caused the gear frame to corrode and resulted in the binding of the shaft. Since the results of this test were known, the geared limit switch and the limit switch housing material at Salem Generat-ing Station has been changed to bronze. An operator equipped with a bronze limit switch housing was retested and passed. The bronze geared limit switch showed no signs of deterioration due to the chemical spray. ,?I Z>

- During the various environmental tests that were performed on the Li~itorque motor operators, certain deficiencies have come to light. Any material or component that has experienced a failure in any of the tests has been replaced with the latest qualified material or component that has success-fully passed. This should preclude any failure due to any identified environmental parameter "in the accident environment condition that was present in the various test environments. A - An aging test was performed by baking the motor at a temperature of 155°c for a total of 100 hours. This test simulated aging the motor to a 40 year life expectancy. An aging analysis was also performed (results \\oJill be in-cluded in next revision to EQ submittal). There has not been any tests that have taken the operator to its ultimate failure, ~ut our calculations show that a minimum life of 17.96 years. Further supporting data is included in our file EQ-1~. PSE&G's evaluation has determined that Limitorque motor operators should perform their safety function. We will be pursuing our review effort to further clarify the Limitorque testing results.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO-NRC SAFETY EVALUATION REPORT EQUIPMENT: Limitorque Motor Operated Valves MODEL: SMB - Class H Insulation (inside containment) COMPONENT NO.: CC187, CC190, CV284 NRC IDENTIFIED DEFICIENCIES: QT, RT, CS, QM, SEN, A, S PSE&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 63-t QI. - These valves are only required to be operable in the initial stages of the accident They have been qualified *. RT - The next revision of the EQ submittal will indicate need for short term ~perabi l i ty. / CS - In the Franklin Institute Research Laboratories Final Report F-C2232-0l, the chemical environment was obtained by spraying 1.5% wt. boric acid buffered with sodium hydroxide to a pH of 7.67 at a rate of 10 gallons per hour for four hours. At the conclusion of the test a sample of con-densate was drawn and found to have a pH of 8.2. After 144 hours of environmental testing, the geared limit switch failed. The geared limit switch aluminum frame had been attacked by the chemicals in the steam atmosphere. This caused the gear frame to corrode and resulted in the binding of the shaft. Since the results of this test were known, the geared limit switch and the limit switch housing material at Salem Generat-ing Station has been changed to bronze. An operator equipped with a bronze limit switch housing was retested and passed. The bronze geared limit switch showed no signs of deterioration due to the chemical spray. 21 F

QM,SEN - During the various environmental tests that were performed on the Limitorque motor operators, certain deficiencies have come to light. Any material or component that has experienced a failure in any of the tests has been replaced with the latest qualified material or component that has success-fully passed. This should preclude any failure due to any identified environmental parameter in the accident environment condition that was present in the various test environments. A - An aging test was performed by baking the motor at a temperature of 155°c for a total of 100 hours. This test simulated aging the motor to a 40 year life expectancy. An aging analysis was also performed (results will be in-cluded in next revision to EQ submittal). There has not been any tests that have taken the operator to its ultimate failure, but our calculations show that a minimum life of 17.96 years. S - Flooding of these valves does not occur until they have performed their safety function. Subsequent failures were analyzed and found to be acceptable. Results provided in FSAR Question 6.28. Basis 28 of Section VII addresses this item. Further supporting data is included in our file EQ-JZ. &G's evaluation has determined that Limitorque motor operators should perfonn ir safety function. We will be pursuing our review effort to further clarify Limitorque testing results. 2/G

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Electrical Cables MODEL: American Insulated Wire Co. COMPONENT NO.: NRC IDENTIFIED-DEFICIENCIES: T, CS, QT, A, S - .E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tern-perature of 340°F as shown in the qualification data evaluation form. This evaluation is contained in our file EQ04.04. A - Rev. 2 of the Environmental Qualification submittal contains aging data specifying an 11 year life for this type cable. Supporting data is available in our file EQ-04.05. CS,.QI,~ - These items are addressed in our submittal. Supporting data is contained in our file EQ-04. PSE&G 1 s evaluation of NRG noted deficiencies has reaffirmed that American Insulated Wire Co. cable is capable of performing safety functions in a harsh environment at Salem.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT eU!PMENT: Electrical Cable MODEL: Samuel Moore COMPONENT NO.: NRC IDENTIFIED-DEFICIENCIES: T, CS, QT, A, S .E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tern-perature of 340°F as shown on the qualification data evaluation form. This evaluation is contained in our file EQ-21.01. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 40 year life for this type cable. Supporting data is available in our file EQ-21.02. ~~ Q[_, ~ - These items are addressed in our submittal. Supporting data is contained in our equipment qualification file EQ-21. PSE&G's evaluation of NRC noted deficiencies has reaffirmed that Samuel Moore cable is capable of performing safety functions in a harsh environment at Salem.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT: Electrical Cables MODEL: Boston Insulated Wire Co. COMPONENT NO.: NRC IDENTIFIED-DEFICIENCIES: T, CS, QT, A, S E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tern-perature of 340°F as shown on the qualification data evaluation form *. This evaluation is contained in our file EQ-05.02. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 20 year life for this type cable. Supporting data is available in our file EQ-0504. CS,.QI_, i-These items.are addressed in our submittal. Supporting data is contained in our equipment qualification file EQ-05. PSE&G's evaluation of NRC noted deficiencies has reaffirmed that Boston In-sulated Wire Co. cable is capable of perfonning safety functions in a harsh environment at Salem

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRG SAFETY EVALUATION.REPORT UIPMENT:

Electrical Cable MODEL: Boston Insulated Wire Co. Coaxial - XLPE Insulation COMPONENT NO.: NRG IDENTIFIED-DEFICIENCIES: T, CS, QT, A, S E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tem-perature of 340°F as shown on the qualification data evaluation form. This evaluation is contained in our file EQ-27.02. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 40 year life for this type cable. Supporting data is available in our file EQ-27.04. CS,.QI_, ~ - These items are addressed in our submittal. Supporting data is contained in our equipment qualification file EQ-27. PSE&G's evaluation-of NRC noted deficiencies has reaffirmed that Boston In-sulated Wire Co. cable is capable of performing safety functions in a harsh environment at Salem.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Electrical Cable MODEL: Boston Insulated Wire Co. Coaxial - Tefzel EFTE Insulation COMPONENT NO.: NRC IDENTIFIED.DEFICIENCIES: . T, CS, QT, A, S E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tem-perature of 340°F as shown on the qualification data evaluation form. This evaluation is contained in our file EQ-24.01. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 40 year life for this type cable. Supporting data is available in our file EQ-24.03. CS,.QI_, ~ - These items are addressed in our submittal. Supporting data is contained in-,our* equipment qualification file EQ-24. PSE&G 1s evaluation of NRC noted deficiencies has reaffirmed that Boston In-sulated Wire Co. cable is capable of performing safety functions in a harsh environment at Salem

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT

-UIPMENT: Electrical Cable MODEL: Triangle - PWC, Inc. COMPONENT NO.: NRC IDENTIFIED-DEFICIENCIES: T, CS, QT, A, S E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tern-perature of 346°F as shown on the qualification data evaluation form. This evaluation is contained in our file EQ-06.04. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 40 year life for this type cable. Supporting data is available in our file EQ-06'.05. CS,.QI,~ - These items are addressed in our submittal. Supporting data is contained in our equipment qualification file EQ-06. PSE&G's evaluation of NRC noted deficiencies has reaffirmed that Triangle - PWC, Inc., cable is capable of performing safety functions in a harsh environ-ment at Salem. 27

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .UIPMENT: Electrical Cables MODEL: Anaconda COMPONENT NO.: NRC IDENTIFIED-DEFICIENCIES: T, CS, A, S .E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tern-. perature of 346°F as shown in the qualification data evaluation form. This evaluation is contained in our file EQ-03.04. A - Rev. 2 of the Environmental Qualification submittal contains aging data specifying a 40 year life for this cable. Supporting data is contained in our file EQ-03.05. CS - These items have been addressed in our submittal. Supporting data is contained in our file EQ-03. PSE&G's evaluation of NRC noted deficiencies has reaffirmed that Anaconda cable is capable of performing safety functions in a harsh environment at Salem.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT: Electrical Cable MODEL: Rockbestos/Cerro COMPONENT NO.: NRC IDENTIFIED-DEFICIENCIES: T, CS, A, S, E&G EVALUATION OF DEFICIENCIES: T - PSE&G has performed a thermal analysis to justify the qualification tern-perature of 340°F as shown on the qualification data evaluation form. This evaluation is contained in our file EQ-08.01. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 40 year life for this type cable. Supporting data is available in our file EQ-08.02. CS, S - These items are addressed in our submittal. Supporting data is con-tained in our equipment qualification file EQ-08. PSE&G's evaluation of NRC noted deficiencies has reaffirmed that Rockbestos/ Cerro cable is capable of performing safety functions in a harsh environment at Salem

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRG SAFETY EVALUATION REPORT IPMENT:

Electrical Cable MODEL: Rockbestos/Silicone COMPONENT NO.: NRC IDENTIFIED "DEFICIENCIES: T, CS, QT, A, S -&G EVALUATION OF DEFICIENCIES:

  • r - PSE&G has performed a thermal analysis to justify the qualification tern-perature of 340°F as shown on the qualification data evaluation form.

This evaluation is contained in our file EQ-07.01. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 40 year life for this type cable. Supporting da.ta is available in our file EQ-07.02. CS,.QI,~ - These items are addressed in our submittal. Supporting data is contained in our equipment qualification file EQ-07. PSE&G's evaluation of NRC noted deficiencies has reaffirmed that Rockbestos/ Silicone cable is capable of performing safety functions in a harsh environ-ment at Salem.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRt SAFETY EVALUATION REPORT PMENT: Electrical Cable MODEL: Okonite COMPONENT NO.: NRC IDENTIFIED QEFICIENCIES: T, CS, A, S &G EVALUATION OF DEFICIENCIES: - PSE&G has *performed a thermal analysis to justify the qualification tempera-ture of 345°F as shown on the qualification data evaluation form.* This evaluation is contained in our file EQ-09.03. A - Rev. 2 of the E.Q. submittal contains aging data specifying a 40 year life for this type cable. Supporting data is available in our file EQ-09.04. CS, S - These items are addressed in our submittal. Supporting data is contained in our equipment qualification file EQ-09. PSE&G 1s evaluation of NRC noted deficiencies has reaffirmed that Okonite cable is capable of performing safety functions in a harsh environment at Salem

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRE SAFETY EVALUATION REPORT IPMENT:

Hydrogen Recombiners (Westinghouse/Sturtevant) MODEL: None COMPONEfff NO.: 11, 12 . NRC ID~NTIFIED D.EFICIENCIES: QT, T, CS, A

  • G EVALUATION OF DEFICIENCIES:

Qualification Data Evaluation Form page 76. The above referenced page located in Section V of our submittal address the above noted deficiencies.* The aging deficiency is supported by basis 1 of the submittal. PSE&G is still awaiting results from Westinghouse on aging specs. of this equipment. Qualification prior to 6/30/82 is expected. PSE&G's evaluation of the noted deficiencies has reaffirmed that plant safety is not jeopardized pending qualification.for a~in~ *

-IPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Motor Control Centers - 230V (General Electric Co.. ) MODEL: 7700 Line COMPONENT NO. : lA East lB East lC East lA West lB West lC West NRC IDENTIFIED-DEFICIENCIES: RT, R, QI ~&G EVALUATION OF DEFICIENCIES: These units will only see a radiation environment. We were confident that the units were capable of withstanding radiation and we did not see any problems in the short term. Our confidence was based on the fact that these type MCC's had been tested to 1 x 106 rads and had passed. However, the manufacturer could not guarantee that the units tested were*composed of the same identical materials in the Salem Units. Since our previous submittal, actual componegts from the Salem Motor Control Centers were subjected to a radiation test of 1 x 10 rads by Isomedix, Inc. and passed. This dosage is equivalent to accident dosage at the end of 40 years. Detailed test data will be included in our file EQ-14 when received from Isomedix, Inc. The EQ submittal will be updated with the new test information.. Therefore, NRC's identified deficiencies RT, R, QI have been addressed. NOTE: Underlined items are correction to NRC SER.

SALEM UNITS 1 A~n 2 PSE&G RESPONSE TO NRC SAFETY EVALUA110tl REPOP."'." I PMEtiT: H2 Analyzers MODEL: Bacha rack C01*'.?0~~E:~;T i;J,: XA8650, XA8651 r~='C 10::*;:1rE::: DSFICIE'.;CIES: RT, QI, QT, T, P, H, CS, R, A Ref. Qualification Data Evaluation Form page 98. This equipment is not qualified and it is the intention of PSE&G to replace with qualified units in accordance with* the TMI requirements time frame. At this time the H2 Analyzers are not being used as a guide for actuating the hydrogen recombiners. They will be operated during the recirculation phase, independent of H2 Analyzer readings. This position is stated in our submittal, Volume I Section VII, basis 30.

IPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT E/P Converter (F15c.he.r ?or-te.rJ MODEL: 546 COMPONENT NO.: 11RH20, 11RH18, 12RH18 NRC IDENTIFIED DEFICIENCIES: EXN &G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form_page 30. By procedural changes these units are rendered incapable of affecting accident conditions and no

  • operator action is required during an accident.

This position is detailed in our submittal, Volume I, Section VII, basis 15. PSE&G is confident that plant safety is maintained with this resolution. 0

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .PMENT: Flow Transmitter (Barton) MODEL: 289A COMPONENT NO.: FA2569, FA2481 NRC IDENTIFIED DEFICIENCIES: EXN ~G EVALUATION OF DEFICIENCIES: ~Ref. Qualification Data Evaluation Form page 31. These devices do not see a harsh environment during normal plant operation. During the recirculation phase and post accident recovery phase of the accident they will be subject to high integrated radiation exposure. The operator. has manual control capability of the RH29 valves associated with these flow trans-mitters. Procedural changes will assure that these valves are correctly position during an accident. Our position is detailed in our submittal, Volume r~ Section VII, basis 16. PSE&G is confident that plant safety is maintained with this resolution *

.IPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Square Root Extractor (Fischer & Porter) 50ES3212 COMPONENT NO.: FA3165Z-2, FA3169Z-2, FA3172Z-2, FA3176Z-2, FA3160Z*Z NRC IDENTIFIED-DEFICIENCIES: RPN E&G EVALUATION OF DEFICIENCIES: .Ref. Qualification Data Evaluation Form page 47.

  • These devices are not exposed to an adverse environment for initial stages of accident, therefore, actuation of fan cooler units can be accomplished.

During long term recovery high radiation could cause failures. As an interim measure the operator will procedurally be required to de-energize control power to the flow control devices to assure service water flow. Prior to 6/30/82 design changes will be incorporated to eliminate the need for any operator action. PSE&G's position is detailed in our submittal, Volume 1, Section VII, basis 20. PSE&G is confident that plant safety will not be jeopardized pending final resolution of this problem.

57 -

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT: Flow Controller (Fischer & Porter) MODEL: 53EG3000 COMPONENT NO.: FA3160C-l, FA3160C-2~ FA3165C-l, FA3165C-2, FA3165C-3, FA3169C-l, FA3169C-2, FA3169C-3, FA3172-1, FA3172-2, FA3172-3, FA3176-l, FA3176-2, FA3176-3,.FA3f GOC-3 NRC IDENTIFIED.DEFICIENCIES: RPN E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 48. These devices are not exposed to an adverse environment for the initial stages of the accident, therefore, actuation of fan cooler units can be accomplished. During long term recovery high radiation could cause failures. As an interim measure, the operator will procedurally be required to de-energize control power to the flow control devices to assure service water flow. Prior to 6/30/82 design changes will be incorporated to eliminate the need for operator action. PSE&G's position is detailed in our submittal, Volume 1, Section VII, basis 20. PSE&G is confident that plant safety will not be jeopardized pending final resolution of this problem

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRG SAFETY EVALUATION REPORT IPMENT:

E/P Converter (Fischer & Porter) MODEL: 53EI3000 COMPONENT NO.: FA3160 FA3165 FA3169 FA3172 FA3176 SW223 Flow Control NRC IDENTIFIED DEFICIENCIES: RPN G EVALUATION OF DEFICIENCIES: Qualification Data Evaluation Form page 49.. The safety function of containment fan coolers 'can be accomplished regardless of flow control operability. The safety function of the fan coolers will be accomplished without need for operator action. Long term recovery may require operator action to compensate for potential failures. As an interim measure procedural charges will suffice to assure long term flow to fan coolers. The final resolution will be to redesign flow control system so that operator action is not requfred to accomplish long term flow. Our submittal, Volume I, Section VII, basis 20 details our schedule and justification for continued operation. PSE&G's* evaluation of.noted deficiency has reaffirmed that plant safety is not jeopardized pending final resolution.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .IIPMENT: Limit Switch (Namco) MODEL:, EA-180 r COMPONENT NO.: 1PR3, 1PR4, 1PR5, 1WL12, 1WL96, 1VC7, 1VC9, lVCll, 1VC13 NRC IDENTIFIED DEFICIENCIES: A, T, CS PSE&G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page 61.

- The aging evaluation review was completed with main.tenance schedules established. This information was added to the Evaluation Form in Revision 2. T - Tile actual test resulted in a peak temperature of 349°F for 3 hours. The Salem required profile is 3S0°F for one minute. This is more than adequate to assure operability at Salem. CS - This item was addressed in our submittal. Further supporting data is available in our file EQ-13. PSE&G's evaluation of the NRC noted deficiencies was reaffirmed that Namco, EA-180 limit switches, are capable of performing safety functions in a harsh environment at Salem

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Thermocouples (Tern Tex Co.)

MODEL: 304-250-T-G-12-SA2-1H-CC-TC COMPONENT NO.: TA4312, TA4313, TA4314, TA4315, TA4316, TA4317, TA4318, TA4319, TA4320, TA4321, TA4348 NRC IDENTIFIED DEFICIENCIES: EXN &G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 80. These particular instruments provide backup foformation for* the operator on containment accident conditions. Since there are other parameters which provide the required information for diagnosis, the operators can maintain plant safety. A procedural change has been made to alert the operators of potential inaccuracy

  • of tempera tu re ind i ca ti on.

This issue 'is addressed in our submittal, Volume I, Section VII, basis 32. PSE&G's evaluation of this* NRC noted deficiency has reaffirmed that plant safety is not jeopardized by the potential loss of this temperature indication

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NR~ SAFETY EVALUATION REPORT PMENT:

Containment Humidity Detectors (Foxboro)

  • MODEL:

2711 AG COMPONEfff NO.: TA357-Z, TA358-Z, TA359-Z, TA360-Z, TA 356-Z NRC IDENTIFIED DEFICIENCIES: EXN G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Form page 83.

These devices are not required for any safety function. Accident diagnosis is based on containment pressure, reactor coolant system pressure, steamflow, steamline pressure and narrow range steam generator level. Therefore, these devices do not require qualification. Our submittal, Volume I, Section VII, basis 37.details our position. PSE&G's evaluation of the noted deficiency has reaffirmed that plant safety is not jeopardized upon failure of detectors *

.IPMENT: MODEL: SALEM UNITS 1 AND 2.: PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Instrument Enclosures {PSE&G) COMPONENT NO.: 241, 245, 238 NRC IDENTIFIED PEFICIENCIES: S E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 62. r Submergence is not a problem. Panels will fill with water and cause instru-ments to be flooded. Flooding of instruments in these panels has been previously addressed and poses no problem since they perform their functions prior to flooding. This item is addressed in our submittal, Volume I, Section VII, basis 28. Further supporting data is available in our file EQ-20. PSE&G 1 s evaluation of the NRC noted deficiency has reaffirmed that these Instrument Enclosures will perform their safety function in a harsh environment

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT:

Limit Switch MODEL: D-2400X-ST COMPONENT NO.: WL108, WL13, WL97, WL99, Nt25, WRBO NRC IDENTIFIED-DEFICIENCIES: EXN, RPS E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 42 These limit switches will be replaced with qualified switches prior to 6/30/82.

        • --***--*~Our submittal, Volume I, Section VII, basis BA

-sfii"tes-oifr--fntentioiis-ancCreasoning for continued operation. PSE&G 1s evaluation of these NRC noted deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRG SAFETY EVALUATION REPORT -UIPMENT: Limit Switch (Microswitch) MODEL: LSQ051 COMPONENT NO.: 1PR18 .NRG IDENTIFIED.OEFICIENCIES: EXN, RPS E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 102 This limit switch will be replaced with a qualified switch prior to 6/30/82. '.Our submittal, Volume I, Section VII, basis TSA states our in~entions *an-d reasoning for c_ontinued operation. Further sup-PSE&G's evaluation of these NRC noted deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. ~,--

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Limit Switch (Masoneilan) MODEL: 496-2 COMPONENT NO.: llMSlO, 12MS10, 13MS10, 14MS10 (21MS18, 22MS18, 23MS18, 24MS18)-(Unit 2 only) NRC IDENTIFIED.DEFICIENCIES: EXN, RPS E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Eyaluation Form page 20. These switches are for position indication only. The switches will be replaced with qualified switches prior to 6/30/82.---------- _-*---- - ----- - --- ----

  • Our submittal, Volume I, Section VII, basis 108 states--oiir-1n-.:.

tentfons"arid -reasoning for continued opera ti-On. ------- ------ ------ ----------." ---****--* ----- -- ------ -*-*--- -. -**----- \\ PSE&G's evaluation of these.. NRC noted* deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT: Limit Switch (Masoneilan) MODEL: 496-2 COMPONENT NO.: (11MS18, 12MS18, 13MS18, 14MS18) (Unit I only) NRC IDENTIFIED.DEFICIENCIES: EXN, RPS .E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 20. These limit switches will be replaced with qualified switches prior to 6/30/82. Our submittal, Volume I, Section VII, basis lOA states our intentions and reasoning for continued operation. Further supporting data is available in our file EQ-13. PSE&G 1s evaluation of these, NRC noted, deficiencies has reaffirmed that plant safety is not jeopardized pending replacement

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT:

Limit Switch (Namco) MODEL: D-2400X-2 COMPONENT NO.. : 11MS167, 12MS167, 13MS167_,'" 14MS167 NRC IDENTIFIED*DEFICIENCIES: EXN, RPS &G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 20A. These limit switches are.used for position indication only. Verification of steamline isolation can be made using information such as steamline pressure and flow measurements. Our submittal. Volume I, Section VII, basis 108 details our reasoning for continued operation and our intensions to replace these switches with qualified ones prior to 6/30/82. PSE&G's evaluation of the NRC noted deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT: Limit Switch (Namco) MODEL: D-2400X COMPONENT NO.: SSllO, SS107, SS104, SS103 NRC IDENTIFIED.DEFICIENCIES: EXN, S &G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 99 These switches do not require qualification. This situation was resolved in our response to FSAR Question 7.35 and 6.28. Our submittal, Volume I, Section VII, basis 188 states our position. PSE&G is confident that plant safety will not be jeopardized by failure of these sw.itches,.Jw.c.cDcve.t-1 to ~k4"'c..e. r-e.liab;lif"y we will r-e..plau tke.:se. fi>"WiRAe..s WI fh lf_rAtif 1 ~ie.J 011(~9

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT:

Limit Switch (Masonei lan) MODEL: 496-2 COMPONENT NO.: WL16 NRC IDENTIFIED.DEFICIENCIES: EXN, S E&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 77. These switches do not require qualification. This situation was resolved in our response to FSAR Question 7.35 and 6.28. Our submittal, Volume I, *section VII, basis 188 states our position. PSE&G is confident that plant safety will not be jeopardized by failure of these switches, howevu-1 t"o en.ha~c.L r-~liab;lify c.cJ~ wJi// r-e.place these.

swi'fc..~es with 'lcAGtl;f2,*e.c!

Dttes.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT ~QUIPMENT: Limit Switch MODEL: Masoneilan 496-2 COMPONENT NO.: 1VC2, 1VC3, 1VC6 NRC IDENTIFIED DEFICIENCIES: EXN, S PSE&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 77. S - The limit switches for the VC2, VC3 and VC6 are not below the flood level as noted in the Evaluation Form. This will be corrected in the next revision to the report. EXN - The limit switches for these valves are inside the containment. VC2 and VC3 valves are the containment isolation valves for the Contain-ment Purge System. These valves by license requirements (Tech Specs) are required to be closed and under administrative control during power operation. The valve is known by the operator to be closed by procedure and it cannot reopen due to the effects of the accident or failure of the limit switch. Therefore, the limit switches do not perform a safety function for the operator during accideot conditions and do not require environmental qualification. The replacement of these switches does not result in any direct increase in safety. The VC6 valve is the containment isolation valve for the Containment Pressure - Vacuum Relief System. This system is used minimally during power operation. The limit switches do not perform a control function but only provide position indication to the operator. Upon an accident, the VCb valves will close. A redundant outside isolation valve will also " close. A redundant outside isolation valve will also close. The potential failure of the limit switch will not result in the operator taking action contrary to safety. This limit switch will be replaced with a fully qualified limit switch as available by 6/30/82. Our evaluation of this item indicates that plant safety is not jeopardized pending installation of the new limit switch. The SER indicates NAMCO limit switches for these valves although they are Masoneilan 496-2 as indicated in the Salem EQ Report

  • ro

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Limit Switch (Mi croswi tc h) MODEL: LSQ-051 COMPONENT NO.: 1PR17 NRC IDENTIFIED _DEFICIENCIES: EXN, S &G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Fann page 101.

These switches do not require qualification. This situation was resolved in our response to FSAR Question 7.35 and 6.28. Our submittal, Volume I, Section VII, basis 188 states our position. PSE&G is cpnficl.e_nt_tba.t_tlan_t __ safety __ wiU __ n_g:Lb.~ j~9_p_ar._gj~ed_~ failure of these sw~tches1 h~w~V'C.-r-1.to Cl\\~>\\~. r.-e.._\\_i~bil;ty we will ,..*c.plac.~-- -tke-$4'!- -:.1'~ifc..1.e9 we tk i<Aot{1 f, eJ eries

  • S-1

PMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Sensing Bellows (Barton) MODEL: 351 COMPONENT NO.: PA2344, PA2345, PA2346, PA2568 NRC IDENTIFIED DEFICIENCIES: T, A, CS, R, RT G EVALUATION OF DEFICIENCIES: Qualification Data Evaluation Form page 54. "RT - The next update of our submittal will indicate a required time of 120 days. A,R-The material composing this instrument is metalic and is insensitive to the effects of Aging and Radiation. T - The next revision to our submittal will indicate a qualified temp of 3S0°F. This temperature is arrived at based on Westinghouse test data which envelopes out plant profile. CS - This item is addressed in our submittal. The EQ submittal will be revised to include information on the oil filled system. Other supporting data is available in our file EQ-28. PSE&G's evaluation ofthese instrument has reaffirmed that they can perform their safety related function in a harsh environment *

.IPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRe SAFETY EVALUATION REPORT Level Switch (GEM) COMPONErn NO.: LA0223' LA0224 ( Re.p lac.e.°' l T-Cf3~ Cl n ol LT* 93'=t) NRC IDENTIFIED DEF~CIENCIES: EXN, RPS G EVALUATION OF DEFICIENCIES: . Qualification Data Evaluation Form page 81, 109, 110 A new level indication system has been installed. As of date it is not environmentally qual.ified. The manufacturer is in the process of qualification. This new system is listed on pages 109 and 110 of our submittal, Rev. 3. Our basis for continued opera-tion is detailed in Volume I, Section VII, basis 31 and in Section XI. PSE&G is confident that plant safety will not be jeopardized pending qualification * ~3

.IPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitters (Fischer & Porter) 10B2495 COMPONENT NO.: FA1087, FA1091, FA1097 NRC IDENTIFIED.DEFICIENCIES: EXN, RPS &G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Fenn page 23.

These pressure transmitters will be replaced with qualified units prior to 6/30/82, , Our submittal, Volume I, Section VII, basis 12 gives - this schedule ~~d our justification for continued operation. PSE&G's evaluation of this. NRC noted deficiency has reaffirmed that plant safety is not jeopardized pending replacement.

>-.,y -

.IPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitters (Fischer & Porter) 1082495 COMPONENT NO.: FA1095 NRC IDENTIFIED *DEFICIENCIES: EXN, RPS &G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page
24.

Jhese pressure transmitt~rs will be replaced with qualified units prior to 6/30/82, i Our submittal, Volume I, Section VII, basis 12 gives this scheduie and-our justification for continued operation. PSE&G's evaluation of this NRC noted defici~ncy has reaffirmed that plant safety is not jeopardized pending replacement *

.IPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitters (Fischer & Porter) MODEL: 1082496 COMPONENT NO.: FA7464, FA0226, FA1422, FA1423, FA7462 NRC IDENTIFIED.DEFICIENCIES: EXN,.RPS E&G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page 59.

These pressure transmitters will be replaced with qualified units prior to 6/30/82, as they become available. Our submittal, Volume I, Section VII, basis 27 gives this schedule and our justification for continued operation. PSE&G's evaluation of this* NRC noted defic;iency has reaffirmed that plant safety is not jeopardized pending replacement.

.UIPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitters (Fischer & Porter) 1082495 COMPONENT NO.: FA3160Z-l, FA3165Z-1, FA3169Z-l, FA3172Z-1, FA3176Z-1, FA1416, FA1419, FA0218, FA0432 NRC IDENTIFIED DEFICIENCIES: EXN, RPS SE&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 58. These pressure transmitters will be replaced with qualified units prior to 6/30/82. )Our submittal, Volume I, Section VII, basis ZO~ZT*.*~lves this schedule and our justification for continued operation. PSE&G's evaluation of this, NRC noted, deficiency has reaffirmed that plant safety is not jeopardiied pending replacement. Note: <AnJerli11e.J i fem~ are. correction to NftC sER ~7

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Square Root Extractor MODEL: 50ES3212 COMPONENT NO.: FA3969, FA3970, FA3972 NRC IDENTIFIED-DEFICIENCIES: EXN, RPS E&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 25. These

  • insti-i.cmirii$
  • \\will be-*-*-,.eloC.Q~c:r
    • -*----**-,:prior to 6/30/82, as they.. become avaflable-. -Our submittal~ Volume--!~- Section**vu, basis 12 gives this schedule and our justification for continued operation.

PSE&G's evaluation of this NRC noted deficiency has reaffirmed that plant safety is not jeopardized pending **e:4"ipm~t.,..e.loucTiol'\\.

IPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Square Root Extractor (Fischer & Porter) MODEL: 50ES3212 COMPONENT NO.: FA3971 NRC IDENTIFIED.DEFICIENCIES: EXN, RPS E&G EVALUATION OF DEFICIENCIES:

f. Qua1ification Data Evaluation Form page 26.

These insirCAme.nr~ will be* __. _ _ret<<Lit~cl __ ----~*-: :- - -- ~--=~- prior to 6/30/82, as they become available. Our submittal, Volume I, Section VII, basis 12 gives this schedule and our justification for continued operation. PSE&G 1 s evaluation of this NRC notE;.d.. deficiency has reaffirmed that plant safety is not jeopardized pending *e.(Ju_ip_men:t_ t"e /oC-Olt'icn..

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT PMENT: Pump Motor - Charging/Safety Injection (Hes ti nghouse) MODEL: W Spin #PNGCSAPCH (Unit 2)

  1. PSECSAPCH (Unit 1)

COMPONENT NO.: llC/L, 12C/L NRC IDENTIFIED DEFICIENCIES: A, RT JjjfG EVALUATION OF DEFICIENCIES: ~ Qualification Data Evaluation Form page 27. Environmental Qualification of these motors has been demonstrated. Our submittal addresses the NRC noted deficiencies. The Required Time and Aging data was arrived at based on Westinghouse test data which envelopes our plant profile. The aging information was added in Revision 2. Supporting data is available in our file EQ-16-. PSE&G's evaluation of these NRC noted deficiencies has reaffirmed that these motors are capable of performing their safety function in a harsh environment.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT I PMENT: Pump Motor - Safety Injection (Westinghouse) MODEL: W Spin #PNJ SIAPSI (Unit 2) PSE SIAPSI (Unit 1) COMPONENT NO.: llSI, 1251 NRC IDENTIFIED DEFICIENCIES: A, RT ~&G EVALUATION OF DEFICIENCIES: ~- Qualification Data Evaluation Fonn page 28 Environmental Qualification of these motors has been demonstrated. Our submittal addresses the NRC noted deficiencies. The Required Time and Aging data was arrived at based on Westinghouse test data which envelopes our plant profile. The aging information was added in Revision 2. Supporting data is available in our file EQ-1£. PSE&G's evaluation of these NRC noted deficiencies has reaffirmed that these motors are capable of performing their safety function in a harsh environment. ~'?B

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT I PMENT: Pump Motor - RHR (Westinghouse) MODEL: \\*1 - Spin #PSEACAPRN (Unit 1)

  1. PJNACAPRN (Unit 2)

COMPONENT NO.: llRHR, 12RHR NRC IDENTIFIED DEFICIENCIES: A, RT &G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Fann page 29.

Envlronmental Qualification of these motors has been demonstrated. Our submittal addresses the NRC noted deficiencies.. The Required Time and Aging data was arrived at based on Westinghouse test data which envelopes our plant ~rofile. The aging in-formation was added in Revision 2. A required time of 120 days will be added in the next EQ submittal revision. Supporting data is available in our file EQ-16. PSE&G's evaluation of these NRC noted deficiencies has reaffirmed that these motors are capable of performing their safety function in a harsh environment.

I SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .UIPMENT: Pump Motor - Chemical Spray (Wes ti nghou se) MODEL: W Spin #PSESIAPCS (Unit 1)

  1. PNISIAPCS (Unit 2)

COMPONENT NO.: llCS, 12CS NRC IDEfffIFIED. DEFICIENCIES: A, RT E&G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page 79.

Enviro1111ental Qualification of these motors has been demonstrated. Our submittal addresses the NRC noted deficiencies. The Required Time and Aging data was arrived at based on Westinghouse test data which envelopes our plant profile. The aging information was added in Revision 2. A required time of 120 days will be added in the next EQ submittal revision. \\ Supporting data is available in our file EQ-16. PSE&G 1s evaluation of these NRC noted deficiencies has reaffinned that these motors are capable of performing their safety function in a harsh environment.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT UIPMENT: Electrical Penetrations (Conax) MODEL: Canister Type - LVP, MVP COMPONENT NO.: 1-1, 1-7, 1-8, 1-14, 1-15, 1-16, 1-17, 1-19, 1-21, 1-23, 1-29, 1-34, 1-35, 1-37, 1-38, 1-39, 1-41, 1-43, 1-46, 1-q1, 1-48, 1-49, 1-50, 1-53, 1-57, 1-59, 1-60, 1-61, 1-62, 1-63, 1-64, 1-65, 2-63, 1-El, l-E2 NRC IDENTIFIED-DEFICIENCIES: A, CS E&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 66. These, NRC noted, deficiencies are addressed in our submittal on the above referenced page. Tke. "~'"~ i"t'or-l'Y\\Alion. wia.s ac:folec:( ii<\\. r-evi~iof"\\,. t.. Documentation is available in our file EQ-02. PSE&G's evaluation of. NRC noted, deficiencies has reaffirmed that Conax Penetra-tions are capable of performing safety functions in a harsh environment * ~I

PMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRG SAFETY EVALUATION REPORT Solenoid Valves {ASCO) MODEL: NP Series I COMPONENT NO.: SV0802, SV0803, SV0927, s,vo75Gf I svo7,o NRC IDENTIFIED DEFICIENCIES: A, RT, CS ~ EVALUATION OF DEFICIENCIES:

  • *.Qualification Data Evaluation Form page 60.

~ All NP series valves are fully qualified for. adverse environmental conditions. All NRC noted deficiencies are addressed in our submittal. All supporting information 1 for th~s~ valves is contained in our file EQ-12. The.. a~i"!) i"'.Por-""~t-;o"' '-"Cl:S it\\c.lc.tcifca 1n re.vis 1 on t. PSE&G's evaluation of NRC noted deficiencies, has reaffirmed that ASCO NP Series valves are capable of performing sfaety functfons in a harsh environment *

.PMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRe SAFETY EVALUATION REPORT Solenoid Valves (ASCO) LB831654 (Unit 1) X 834283 (Unit 2) COMPONEfff NO.: SV1078, SV1080, SV1082, SV1084 NRC I DENT I FI ED DEFI CI ENCI ES: RPS, RT G EVALUATION OF DEFICIENCIES: .<Qualification Data Evaluation Fenn page 32, 89 These solenoids will be replaced with qualified valves prior to 6/30/82. ____ ----**-- ~~~~~~--** --*--

      • -*****Our submittal, Volume I, Section VII, basis 17, gives this schedule and----;--

our--ju*s-tiTi cation for continued opera ti on. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPME,NT:

Solenoid Valves (ASCO) MODEL: 83165/f COMPONENT NO.: SV0249, SV0164 [ rA11.1'tt.1 0.. 1, NRC IDENTIFIED.DEFICIENCIES: RPS &G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 91. These solenoids will be replaced with qualified valves prior to 6/30/82.


*- --------- ----------.,Our submittal, Volume I, Section VII, basis 17, gives this ___ _

sche-dl.iie_a.nd-our justification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement * '~

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Solenoid Valves (ASCO) MODEL: HTX 8344A75 (Unit 1) HT8344A77 (Unit 2) COMPONENT NO.: SV1023 NRC IDENTIFIED DEFICIENCIES: RPS G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Form page 34A, 93 Itie~~---~-ole.noi9s ___ wj_ll be replaced with qualified valves. prior to 6/30/82. -~----~ -*----
  • our submittal, Volume I, Section VII, basis 17, gives this __ _

-schedule.. aria***aur -.)ustification for continued operation. PSE&G' s evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement

  • MODEL:

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC-SAFETY EVALUATION REPORT ENT: Solenoid Valves (ASCO) HT834475 COMPGNE!ff NQ.: SV1025 (Unit 1) N;{C IDC:NTIF!ED DE-F:CIEllCIES: RPS EVALUATION OF DEFICIE~CIES: . Qualification Data Evaluation Form page 35A. These solenoids will be replaced with qualified valves prior to 6/30/82. Our submittal, Volume I, Section VII, basis 17, gives this schedule and our justification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

PMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRG SAFETY EVALUATION REPORT Solenoid Valves (ASCO) MODEL: HT834477 COMPONENT NO.: SV0804 (Unit 1) NRC IDENTIFIED DEFICIENCIES: RPS G EVALU.A.TION OF DEFICIENCIES:

  • Qualification Data Evaluation Form page 358.

These solenoids will be replaced with qualified valves prior to 6/30/82. Our submittal, Volume I, Section VII, basis 17, gives this schedule and our justification for continued operation. PSE&G's evaluation of these deficiencies has reaffinned that plant safety is not jeopardized pending replacement..

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NR( SAFETY EVALUATION REPORT ENT: Solenoid Valves (ASCO) MODEL: NP Series C0!*1?0NE!ff NO.: SV0924 N~C IDENTIFIED DEf!CIENCIES: RPS EVALU.l:.TION OF DEFICIEr:cIES: R Qualification Data Evaluation Form page 60. All NP series valves are fully qualified for adverse environmental conditions. All NRC noted deficiencies are addressed in our submittal. All supporting information for these valves is contained in our file EQ-12. T"-i.s cr-ole"o'c;o{ v<<Lve.. oloe:s... ot- ~"""t.. ....e..p lctee.m.e.t\\~* PSE&G's evaluation of NRC noted deficiencies, has reaffirmed that ASCO NP Series valves are capable of performing sfaety functions in a harsh environment

  • eUIPMENT:

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Instrument Enclosures {PSE&G) MODEL: 1, 2, 3, 4 Bay Vertical & NEMA 12 Enclosures COMPONENT NO.: 335, 445A-H, 444A-M, 684A-D, 685A-B, 686A-D, 6831A-D, 6681A-D, 6891A-D, 687A-D, 691A-C, 215, 219, 202, 101, 102, 743, 311, 233, 234, 235, 236, 208, 325, 318, 713, 714, 317, 440A-F, 224A-C, 316A, 3168, RPI RACK,6~0, Unit 2 only - 797A, 7978 Unit 1 only - 241, 237 NRC IDENTIFIED-DEFICIENCIES: RT E&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 62. Instrument enclosures must only be able to survive the initial pressure and tempera-ture transients. The time duration is approximately 24 hours. After 24 hours our plant profile shows a steady state condition, and these steelenclosures will not be affected. A 24-hour LOCA test was conducted by PSE&G to prove these instrument enclosures. Results of tests are available in our file EQ-20. PSE&G's evaluation of the noted deficiencies has reaffirmed that PSE&G instrument enclosures can perform . safety functions in a harsh environment.

.UIPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Terminal Blocks (Buchanan) 2Bll2N COMPONENT NO.: See attachment. NRC IDENTIFIED* DEFICIENCIES: T, CS, A ~E&G EVALUATION OF DEFICIENCIES: ~f. Qualification Data Evaluation Form page 64. Subject equipment has been environmentally qualified. The above referenced page addresses all noted deficiencies. A~il\\~,*".Po..-""'"~+io.... ""'a..-s i"d"'-ol~c:t i",...<v<~io"' Z.. Supporting data on testing and analysis is available in our file EQ-19. PSE&G's evaluation of the NRC noted deficiencies has reaffirmed that Buchanan Terminal Block can perform safety functions in a harsh environment * ,9 -

~

  • I ATTACHMENT COMPONENT NO.:

JN628, JN629, JN630, JN631, JN632, JN633, JN634, JN635, JN661, JN662, JN663, JN664, JN665, JN667, JN668, JT7, JS168, JS170, JS682, JT57, JT525, JT578, JT582, JT579, JT583, JN145, JN148, JN149, JN107, JN109, JN345, JN346, JN347, JN348, JN349, JX94, JX95, JT9, JTlO, JN89, JN90, JN91, JN92, JN94, JN95, JN96, JN97, JT376, JT377, JT350, JS618, JS619, JN673, JN674, JN610, JN613, JS620, JT480, lVCl, 1VC2, 1VC3, 1VC4, JT528, JT529, 1VC5, 1VC6, 448A, 448B, 448C, 4480, 684A, 684B, 684C, 6840, 685A, 685B, 685C, 6850, 686A, 686B, 686C, 6860, JN666, JT631, 6831A, 68318, 6831C, 68310, 6891A, 68918, 6891C, 68910, 6881A, 6881B, 6881C, 68810, 691A, 6918, 691C, 690, 215, 219, 713, 714, 317, 101, 102, 211, 224A, 2248, 224C, 216A, 216B, 241, 743, 311, 208, 233, 234, 235, 236, 325, 218, JT558, JT559, JT560, JT561, #11 Ref. Jct. Box,

  1. 12 Ref. Jct. Box UNIT 1 ONLY JN120, JN139, JT536, JT362, JT534, JT455, JT456, JT457, JT458, JT459 UNIT 2 ONLY JN146, JN147, JN839, JN840, JX39, JT363, JT535, JT460, JT461, JT462, JT463, JT464

.UIPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Cable Splices (Raychem) WCSF-N COMPONENT NO.: j35, 440A, 4408, 440C, 440D, 445A, 4458, 445C, 445D, 445E, 445F, 445G, 445H, 444A, 4448, 444C, 444D, 444E, 444F, 444G, 444H, 4441, 444J, 444K, 444L, 444M, 245, 238, 341, JN-148, lVCl, 1VC2, 1VC3, 1VC4 Unit 1 only - 241, 237 Unit 2 only - 797A, 7978 NRC IDENTIFIED.DEFICIENCIES: A, CS E&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 65.* The subject splices are fully qualified and are addressed in our submittal, Volume I, Section V, page 65. All noted deficiencies have been addressed and supporting, infQnm;1tjon js available in our file EQ-01. Tkc. c:i~i"'"~ *,"-.ror"""ert:o°I"\\. <<.A.'~s 1n c. lCA o\\ecA l"' ~e.v 1s10 t'\\. :l. PSE&G's evaluation of noted deficiencies has reaffirmed that Raychem Cable Splices can perform safety functions in a harsh envfronment. 71 -

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Motor (Westinghouse) MODEL: Spin #PSE-RCADCF (Unit 1) PNJ-RCADCF (Unit 2) COMPONENT NO.: 11, 12, 13, 14, 15 NRC IDENTIFIED-DEFICIENCIES: A, CS &G EVALUATION OF DEFICIENCIES: .Ref. Qualification Data Evaluation Form page 75. Environmental Qualification of these motors has been demonstrated. Our submittal addres$eS the noted deficiencies. The Aging and Chemical Spray data was arrived at based on Westing*housea test data which envelopes our plant profile. Tke. <<~in~ '".Poi-rt'\\G'\\ ti o... ""'" 'S at:A e.cl i"' r-~'f i ~ i o"' ~. Supporting data is available in our file EQ-15. PSE&G 1s evaluation of these noted deficiencies has reaffirmed that these motors are capable of performing their safety function in a harsh environment.

72.

MODEL: 763 SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitter (Barton) Prod. Lot 2 COMPONENT NO.: (PA0039, PA8088) (Unit 1) NRC IDENTIFIED.DEFICIENCIES: RT, A, S &G EVALUATION OF DEFICIENCIES: ef. Qualifi~ation Data Evaluation Form page 3. These pressure transmitters will be replaced with qualified units prior to 6/30/82, Our submittal, Volume I, Section VII, basis 2, gives this schedule and our justi,ficatioriJor continued operation. n~::re. "fl..~l')'\\;'ftc:r-.s no"t 'ctbmc'I"'~~* Tkc. """ c..(c;r.tio"' ~~,*.,o(;e.ate-:: ~&y Al-~ "'boy-e ~ f>loec:f le~(. PSE&G 1s evaluation of these deficiencies has. reaffirmed that plant safety is not jeopardized pending replacement

  • 73 -

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Pressure Transmitter (Barton) MODEL: 764 Prod. Lot 2 COMPONENT NO.: (LA0086, LA0087, LA0088) (Unit 1) NRC IDENTIFIED DEFICIENCIES: RT, A &G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 5. These pressure transmitters will be replaced with qualified units prior to 6/30/82. Our submittal, Volume I, Section VII, basis 2, gives this schedule and our justification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. 71--

eUIPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitter (Fischer & Porter) MODEL: 50EP1031 COMPONENT NO.: PA0230, PA0231, PA0236 NRC IDENTIFIED.DEFICIENCIES: RPS E&G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 14B. These devices will be replaced by 6/30/82, in order to comply with NUREG 1.97

  • Our submittal Volume I, Section VII, basis 24 details our position and justification for continued operation.

PSE&G Evaluation of noted deficiency has reaffirmed that plant safety is not jeopardized pending replacement. 7-S--

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Pressure Transmitters (Fischer & Porter) MODEL: 50 EP1041 COMPONENT NO.: PA0227, PA7461, PT0942 NRC IDENTIFIED "DEFICIENCIES: RPS &G EVALUATION OF DEFICIENCIES: Ref. Qualification Data Evaluation Form page 51. Replacement of these transmitters is not anticipated. Inoperability of these n t devices would not r~sult in termination of safety injection,(),.. a~t p\\""t"' ":S"~t'~ '(* Our justification for accepting these devices as they now exist is detailed in our submittal, Volume I, Section VII, basis 21. PSE&G 1s evaluation of noted deficiences has reaffirmed that these transmitters will perform their function. 7C

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Solenoid Valves (ASCO) MODEL: LB831654 COMPONENT NO.:

SV0114, NRC IDENTIFIED DEFICIENCIES:. RPS

&G EVALUATION OF DEFICIENCIES: _

  • Qualification Data Evaluation Form page 32.

These solenoids will be replaced with qualified valves prior to 6/30/82.

  • - -** -*---*:.Our submittal, Volume I, Section VII, basis 17, gives flifs ______ _
  • sch~d~le arid-6~i-justification for continued operation.

PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. 77

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .IPMENT: Solenoid Valves (ASCO) MODEL: X8342B22 COMPONENT NO.: SV0558, SV0559 NRC IDENTIFIED.DEFICIENCIES: RPS E&G EVALUATION OF DEFICIENCIES: . f. Qualification Data Evaluation Form page 33. These solenoids will be replaced with qualified valves prior to 6/30/82. ** --- -----** ---**-*.:Our submittal, Volume I, Section VII, basis 17, gives this schedule-ancrour justification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT EQUIPMENT:

MODEL: COMPONENT NO.: NRC IDENTIFIED DEFICIENCIES: SE&G EVALUATION OF DEFICIENCIES:

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .IPMENT: Solenoid Valves (ASCO) MODEL: HT834477 COMPONENT NO.: SV1024 NRC IDENTIFIED.DEFICIENCIES: RPS &G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page 35.

These solenoids will be replaced with qualified valves prior to 6/30/82, ~---:*------,

  • Our submittal, Volume I, Section VII, basis 17, gives ttffs ____ _

"schedule" arid" our-Justification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Solenoid Valves (ASC)) MODEL: HT834475 COMPONENT NO.: SV0805 NRC IDENTIFIED DEFICIENCIES: RPS E&G EVALUATION OF DEFICIENCIES: f.. Qualification Data Evaluation Form page 35. _Jl}f?~~---?_9)e_l'!_Qjds __ w_ill be replaced with qualified valves prior to 6/30/82. _____________ _


*~- Our submittal, Volume I, Section VI I, basis 17, gives this schedule and our justification for continued operation.

PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. 1'!

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .UIPMENT: Solenoid Valves (ASCO) MODEL: LBX83146 COMPONENT NO.: SV0514, SVOS15, SV0516, SV0517, SV0505 rul\\\\t 11 L~L~ NRC IDENTIFIED DEFICIENCIES: RPS SE&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 37. These solenoids will be replaced with qualified valves prior to 6/30/82. --- ---- -- *-- ***** **- -----*-----*-°'Our sutxnittal, Volume I, Section VII, basis 17, gives tfi1s ________ _

  • si:hedule-anc:four-justification for continued operation.

PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. YZ -

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Solenoid Valves (ASCO) MODEL: FT8320Al01 COMPONENT NO.: SV0510, SVOSlL, SV0512, SV0513 NRC IDENTIFIED _DEFICIENCIES: RPS &G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Form page 38.

These solenoids will be replaced with qualified valves prior to 6/30/82, :--****--*--*---

  • - * * **** *-*-**:*-*,**,our submittal, Volume I, Section VII, basis 17, gives -thfs _________ _

schedule and* "Oiir-*Justification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

.IPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Solenoid Valves (ASCO) MODEL: FT8321A2 COMPONENT NO.: SV0706, SV0707, SV0708, SV0709, SV0402, SV0398, SV0396 [ u~:t t] e" \\~ NRC IDENTIFIED DEFICIENCIES: RPS 1///11//JiJ.E&G EVALUATION OF DEFICIENCIES: WJf

  • Qualification Data Evaluation Form page 39.

These solenoids will be replaced with qualified valves prior to 6/30/82,*:_=----------- - -- ------- -- - ---,Our sul:mittal, Volume I, Section VII, basis 17, gives this-- schedu-1 e--aricrour--justifi ca ti on for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. t1

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Level Transmitter MODEL: Barton 332/352 COMPONENT NO.: LA-0217 NRC IDENTIFIED-DEFICIENCIES: RPS E&G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Data Form page 53.

Basis 23 of Section VII indicates that this instrument does not perform a safety function needed by the operator. Plant safety is not affected whether the device fails or not. Replacement is not required. PSE&G's evaluation of this NRC noted deficie_ncy has reaffirmed that plant safety is not dependent on this instrument *

.UIPMENT: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Solenoid Valves (ASCO) MODEL: FT831654 COMPONENT NO.: SV0117, SV0118, SV0119,.SV0164,.SV0575 --g ofk ~ [""it t.] fL4.-.:t t]

  • ,, *t o,d'a Lo"I~

\\,U\\I :;$ NRC IDENTIFIED.DEFICIENCIES: RPS E&G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 57. Jhese so}ei:tQi_ds_ will be replaced with qualified valves prior to 6/30/82. -~.~---------- __. -*-* ________, Our submittal, Volume I, Section VII, basis 25, gives thfs ____ _ schedule and our justification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT ttUIPMENT:

MODEL: COMPONENT NO.: NRC IDENTIFIED DEFICIENCIES: .PSE&G EVALUATION OF DEFICIENCIES: Lt;-,, li"f)/IQ 17

  • fe,Rf I

Ela/I. k..

PMENT: MODEL: TA-63A SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Radiation Monitors (Trapelo) COMPONEHT NO.: (RA-4314, 1R21) (Unit 1) NRC IDENTIFIED DEFICIENCIES: RPS G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Fonn page 84.

Per our submittal this device was to be replaced in Spring, 1981. Due to qualification and delivery probleins insta-lation at that time was not accomplished. At this time qualification has been established and* the units will be installed once delivered. Our submittal, Volume I, Section VII, basis 35 details our intent 1iol'!s and jus,tification for continued operation.

r"~t"oclbt;o"' "'ill be. etC.C..Dr'>"\\pli:::she&t ctc.c.01""C1t<<nc..e_ cJirk TM I I"~ i'.t--c.M.<l\\1-
sc.ke.c&-tle..

PSE&G's evaluation of noted deficiencies has reaffirmed that plant safety is not jeopardized pending replacement of these units

  • 8'1 -

.IPMENT_: MODEL: 384 SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitter (Barton} COMPONENT NO.: LA0009, LA0015, LA0021, LA0027 NRC IDENTIFIED DEFICIENCIES: RT, A -&G EVALUATION OF DEFICIENCIES: ~f. Qualification Data Evaluation Form page 14. These pressure transmitters will be replaced with qualified units prior to 6/30/82,

  • * * * --** * **** ----- *Our submittal, Volume I, Section VII, basis 5, gives tfds -schedule.. and our*-.fi.is-tification for continued operation.

PSE&G's evaluation of these deficiencies has. reaffirmed that plant safety is not jeopardized pending replacement.

elPMENT.: MODEL: 384 SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitter (Barton) COMPONENT NO.: LA0228, LA0229, LA0233, LA0237, LA0238, LA0241, LA0242, LA0234 NRC IDENTIFIED.DEFICIENCIES: RT, A &G EVALUATION OF DEFICIENCIES: ef. Qualification Data Evaluation Form page 14A. These pressure transmitters will be replaced with qualified units prior to 6/30/82.

  • -*-*-* ** *-* - -***- *- - *----\\Our submittal, Volume I, Section VII, basis 24, gives

""this""s"C:hedule-and our.)u-stification for continued operation. PSE&G 1s evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement. 'ii '1

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Pressure Transmitter (Fischer & Porter) MODEL: 50EP1031BCXA-NS COMPONENT NO.: PA0244, PA0243, PA0239, PA0240, PA0235 NRC IDENTIFIED bEFICIENCIES: RPS &G EVALUATION OF DEFICIENCIES: ef.. Qualification Data E_valuation Form page 148. These pressure transmitters will be replaced with qualified units prior to 6/30/82.

    • ------ -* ** -\\Our submittal, Volume I, Section VII, basis 24, gives

-tfi1~i *schedu-ie--incr"ciLir--.)ustification for continued operation. PSE&G 1 s evaluation of these deficiencies has. reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EV ALUAT.ION REPORT EQUIPMENT: MODEL: COMPONENT NO.: NRC IDENTIFIED DEFICIENCIES: .SE&G EVALUATION OF DEFICIENCIES: '11 -

.UIPMENT: MODEL: SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Solenoid Valves (ASCO) FT831654 COMPONENT NO.: SV0688 NRC IDENTIFIED.DEFICIENCIES: RPS E&G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page 96.

These solenoids will be replaced with qualified valves prior to 6/30/82. ~~:-~---.

    • -\\Our submittal, Volume I, Section VII, basis 17, gives thrs-*-----

. schedule--a:na**-aur--3ustifi ca ti on for continued opera ti on. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT .UIPMENT: Solenoid Valves (ASCO) MODEL: FT8314B6 COMPONENT NO.: SV0400, SV0423 NRC IDENTIFIED. DEFICIENCIES: RPS E&G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page 97.
T_~~s.e _s.ol~r:i9jq~_.\\'t_ill be replaced with qualified valves prior to 6/3.0/82. ________ _
  • Our submittal, Volume I, Section VII, basis 17, gives this

-*s-Cli-ed°ule and-- our--JUStification for continued operation. PSE&G's evaluation of these deficiencies has reaffirmed that plant safety is not jeopardized pending replacement

  • 93

.PMENT: MODEL: TBFC SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT Fan Motor (Westinghouse) COMPONENT NO.: None NRC IDENTIFIED DEFICIENCIES: S G EVALUATION OF DEFICIENCIES: Qualification Data Evaluation Form page 88. Subject motors do not require environmental qualification. They do not perfonn a safety function. Failure of these motors does not affect the course of action in response to a design basis accident. Therefore, submergence is not a consideration. This item is addressed in our submittal, volu"""e.1., 'S'e.e.ti 0"-"llL, basis 3G. PSE&G 1 s evaluation of the noted deficiency has reaffirmed that plant safety is not jeopardized due to motor failures

  • 9~

III.B. NRC Noted Deficiencies of Appendix C The attached information provides an evaluation of the specific com-ponents/equipment identified by the NRC. Only those items with a cited deficiency are included. Items in Appendix C without a cited deficiency were assumed to have been acceptable to the Staff. The major concern in this section is the aging evaluation program at Salem. The Staff review was based on Revision 1 of the Salem Environ-mental Qualification Review Report. Revision 2 of the report in-cluded the results of the Salem aging review which was described in Section X of the report. Maintenance schedules for selected equip~ ment were provided in the Qualification Evaluation Data Forms of Section V in Revision 2 of the report

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT PMENT:

RTD (Rosemount) MODEL: 176KF A,C COMPONElff NO.: TA0040, TA0041, TA0050, TA0051, TA0060, TA0061, TA0070, TA0071, TA2437, TA2438, TA2440, TA2441, TA2443, TA2444, TA2446, TA2447. NRC IDENTIFIED DEFICIENCIES: A G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Form page 1.

An aging review is being conducted for these devices. As of date a qualified life has not been established. Qualification is expected prior to 6/30/82. Our submittal, Volume I, Section VII, basis 1 details our position and justification for continued operation. PSE&G's evaluation of noted deficiency has reaffirmed that plant safety is not jeopardized pending qualification

  • SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT PMENT:

Pressure Transmitters (Rosemount) MODEL:

11. 53 AG-A COMPONENT NO.:

PA0082, PA0083, PA0084, PA0097 NRC IDENTIFIED DEFICIENCIES: A G EVALUATION OF DEFICIENCIES:

  • Qualification Data Evaluation Form page 7.

An aging review is.being conducted for these devices. As of date a qualified life has not been established. These transmitters will either be qualified or replaced prior to 6/30/82. Our submittal, Volume I, Section VII, basis 1 details our position and justification for continued operation. PSE&G's evaluation of noted deficiency has reaffirmed that plant safety is not jeopardized pending qualification. f 7

SALEM UNITS 1 AND.2 PSE&G RESPONSE TO NRC S.AFETY EVALUATION REPORT IPMENT: Solenoid Valves {ASCO) MODEL: NP Series COMPONENT NO.: SV0920, SV0921, SY0922, SV0923, SV0924, SV1022, SV1026, SV1077, SV1079, SV1081, SV1083, SV0506 NRC IDENTIFIED -DEFICIENCIES: A &G EVALUATION OF DEFICIENCIES: .,ef. Qualification Data Evaluation Form page 60. All NP series val~e~ ar~ fullrqualified f~r adverse ~nvironmental condi~ion~. All NRC noted deficiencies are addressed 1n our submittal. All supporting in-formation for these valves is contained in our file EQ-12. This solenoid valve does not require replacement. These valves are qualified for a 40 year life provided coils and elastomers are replaced every 4.4 years. PSE&G 1s evaluation of NRC noted deficiencies, has reaffirmed that ASCO NP series valves are capable of performing safety functions in a harsh environment.

SALEM UNITS 1 AND 2 PSE&G RESPONSE TO NRC SAFETY EVALUATION REPORT IPMENT: Pressure Transmitters (Rosemount) MODEL: 1153AHA COMPONENT NO.: FAlOl, FA102, FA103, FA104, FA0688, FA0689, FA0690 NRC IDENTIFIED *DEFICIENCIES: A &G EVALUATION OF DEFICIENCIES:

f. Qualification Data Evaluation Form page 11.

An aging review is being conducted for these devices. As of date, a qualified life has not been established. These transmitters will either be qualified *or replaced p~ior to 6/30/82. Our submittal, Volume I, Section VII, basis 2 details our position and Justifi-. cation for continued operation. PSE&G's evaluation of noted deficiency has reaffirmed that plant safety is not jeopardized pending qualification

  • 978

REFERENCES Salem Environmental Qualification Review Report - Revision 1 dated 12/1/80.

2.

Salem Environmental Qualification Review Report - Revision 2 dated 1/16/81.

3.

Salem Environmental Qualification Review Report - Revision 3 dated 2/9/81.

4.

Letter Mr. T. M. Novak, NRC to Mr. F. W. Schneider, PSE&G dated 2/26/81 transmitting preliminary Staff Equipment Evaluation Report for Unit 1.

5.

Letter, Mr. S. A. Varga, NRC to Mr. F. W. Schneider, PSE&G dated 6/8/81 transmitting Staff Environmental Qualification Safety Evaluation Report for Unit 1.

6.

Letter, Mr. F. W. Schneider, PSE&G to Mr. T. M. Novak, NRC dated 3/6/81 transmitting PSE&G response to Staff preliminary evaluation.

7.

Environmental Qualification Documentation Files of PSE&G Corporate Home Office, EQ-1 through EQ-30.

8.

NRC Trip Report (issued 4/28/81) of December 9-10, 1980 Audit of PSE&G's Qualification Documentation in Newark, New Jersey.

9.

NRC Exit Interview Report (preliminary) of January 7-9, 1981 Audit of PSE&G's Qualification Documentation in Newark, New Jersey.}}