ML18086A820
| ML18086A820 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 07/21/1981 |
| From: | Mittl R Public Service Enterprise Group |
| To: | Miraglia F, Varga S Office of Nuclear Reactor Regulation |
| References | |
| RTR-NUREG-0578, RTR-NUREG-578 NUDOCS 8107290171 | |
| Download: ML18086A820 (2) | |
Text
- '
.r...
0 PS~G Public Service Electric and Gas Company 80 Park Plaza, T160 Newark, N.J. 07101 201/430-8217 Robert L. Mittl General Manager - Licensing and Environment July 21, 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Attention:
Mr. Steven A. Varga, Chief Operating Reactors Branch 1 Division of Licensing Gentlemen:
Mr. Frank J. Miraglia; Chief Licensing Branch 3 Division of Licensing SAFETY VALVE POSITION SWITCHES UNIT NO. 1 AND 2 SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-272 AND 50-311 In our March 28; 1980 response to Item 2.1.3.a of NUREG 0578; we committed to install by June 1, 1980 improved switches on the safety valves for Units 1 and 2.
Although purchased~ these switches have not been installed yet; due to lack of appropriate documentation concerning their seis-mic and environmental qualifications.
The manufacturer of these improved switches is in the proc-ess of performing the seismic and environmental qualif ica-tion tests; and the estimated completion date is January 1982.
As soon as this process is completed and an outage of sufficient duration occurs; we will install the improved switches on the safety valves.
We wish to emphasize that the switches presently installed are fully qualified for both seismic and environmental conditions.
8107290171 810721 PDR ADOCK 05000272 P
PDR The Energy People 7/21/81 Should you have any questions in this regard~ do not hesi-tate to contact us.
CC:
Mr. Leif Norrholm Senior Resident Inspector HA7 1/2