PS~G Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 June 17, 1981 Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Attention:
Mr. S. A. Varga, Chief Operating Reactors Branch 1 Division of Licensing Gentlemen:
SAFETY EVALUATION LOST TELEVISION CAMERA LENS HOUSING NO. 1 UNIT SALEM GENERATING STATION DOCKET NO. 50-272 As requested by NRC's Office of Inspection and Enforcement, attached for your review is our Evaluation of Safety Conse-quences associated with a lost television camera lens housing in the reactor coolant system for No. 1 Unit.
Based upon our review, we believe that continued operat~on of the unit prior to material recovery does not constitute an Unreviewed Safety Question, as defined in 10Cp~50.59.
Your prompt and favorable consideration of this matter to permit startup and operation of Unit No. 1 will be appreciated.
JMZ:to'g Attachment The Energy Pe... oBle "8106 2 30 ~'fS-Sincerely,
/~~
Richard A. Uderitz General Manager -
Nuclear Production 95-2001 (350M) 4-80