Forwards IE Insp Repts 50-272/80-19 & 50-311/80-14 on 800728-0808 & Notice of Violation
ML18085A480
Person / Time
Site: Salem  
Issue date: 09/29/1980
From: Brunner E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Schneider F
Public Service Enterprise Group
Shared Package
ML18085A478 List:
References
NUDOCS 8101090858
Download: ML18085A480 (2)


See also: IR 05000272/1980019

Text

Docket Nos. 50-272

50-311

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION I

631 PARK AVENUE

KING OF PRUSSIA, PENNSYLVANIA 19406

SEP 2 9 1980

Public Service Electric and Gas Company

ATTN:

Mr. F. W. Schneider

Vice President - Production

80 Park Plaza - lSA

Newark, New Jersey 07101

Gentlemen:

Subject:

Combined Inspection 50-272/80-19 and 50-311/80-14

This refers to the routine inspection conducted by Messrs. G. Napuda and G.

Simonetti of this office on July 28-31, August 1, and 4-8, 1980 at Salem Nuclear

Generating Station Units 1 and 2, Hancocks Bridge, New Jersey and Newark, New

Jersey corporate offices .of activities authorized by NRC License Nos. DPR-70 and

DPR-75 and to the discussions of our findings held by Mr. Napuda with Messrs. E.

Schwalje, F. Omohundro and other members of your staff on August 5, 1980; Mr .

. Midura and other members of your staff on August 8, 1980.

Areas examined during this inspection are described in the 0.ffice of Inspection

and Enforcement Inspection Report which is enclosed with this letter. Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observations by the

inspector.

Our inspector also verified the steps ~u have taken to correct the items of

noncompliance brought to your attention.in the enclosure to our letter dated May

6, 1980.

We have no further questions regarding your action at this time.

.

.

Based on the results of this inspection, it appears that certain of your activi-

ties were not conducted in full compliance with .NRC requirements, as set forth

in the Notice of Violation, enclosed herewith as Appendix A.

These items of

noncompliance have been categorized into the levels as described in our corres-

pondence to you dated December 31~ 1974. This notice is sent to you pursuant to

the provisions of Section 2.201 of the NRC 1s

11 Rules of Practice,

11 Part 2, Title

10, Code of Federal Regulations. Section 2.201 requires you to submit to this

office, within twenty (20) days of your receipt of thi$ notice, a written state-

ment or explanation in reply including:

(1) corrective steps which have been

taken by you and the results achieved; (2) corrective steps which will be taken

to avoid further items of noncompliance; and (3) the date when full compliance

will be achieved.

...

Public Service Electric

and Gas Company

SEP 2 9 1980*

2

In accordance with Section 2.790 of the NRC's "Rules of Practice," Part 2, Title

10, Code of Federal Regulations, a copy of this letter and the enclosed inspection

report will be placed in the NRC's Public Document Room.

If this report contains

any information that you (or your contractor) believe 'to be propri.etary, it is

necessary that you make a written application within 20 days to this office to

withhold such information from public disclosure.

Any such application must be

accompanied by an affidavit executed by the owner of the information, which

identifies the document or part sought to be withheld, and which contains a

statement of reasons which addresses with specificity the items which will be

considered by the Commission as listed in subparagraph (b) (4) of Section

.

2.790.

The information sought to be withheld shall be incorporated as far as

possible into a separate part of the affidavit. If we do not hear from you in

. this regard within the specified period, .the report will be placed in the Public

Document Room.

Should you have any questions concerning this inspection, we will be pleased to

discuss them with you.

Sincerely,

Enclosures:

1.

Appendix A, Notice of Violation

2.

Combined Office of Inspection and Enforcment Inspection

Report Number 50-272/80-19; 50-311/80-14

cc w/encl:

F. P. Librizzi, General Manager - Electric Production

E. N. Schwalje, Manager - Quality Assurance

R. L. Mittl, General Manager - Licensing and Environment

H. J. Midura, Manager - Salem Generating Station

R. A. Uderitz, General Manager - Fuel Supply Department